• Title/Summary/Keyword: wide width effect

Search Result 127, Processing Time 0.024 seconds

A Study on the Visual Effects According to the Lines in Cloth Designing (의복 디자인 선에 따른 시각적 효과에 관한 연구)

  • 이경희
    • Journal of the Korean Home Economics Association
    • /
    • v.28 no.4
    • /
    • pp.1.1-13
    • /
    • 1990
  • Authors have performed the sensory evaluation tests according to each given items after selecting various lines in order to assess the visual effects by the lines in cloth designing. The evaluations were done by means of ranking tests followed by paired comparison tests. The results obtained were as follows : 1. In the item in than "Shoulder width looks wide", the design C3 showed the best visual effect, and then B1, F8, and A5 comes in order. In "Shoulder width looks narrow", they were A2, F5, F7, and B2 in order. 2. In "Bust looks big", the effect was best in F9, and then B1, F5, C3, and A5 and order. "Bust looks small" item showed A3, C1, and F1 in order. 3. In "Waist looks thick", they were B2, D1, and F7 while in "Waist looks thin", they were B3, F8, and D6 in order. 4. In the item in that "Hip looks big", the best effect was in F9, and then E3, C2, and B4 in order. In "Hip looks small", the best one was C1, and then comes. E1, F6, and F8. 5. In "Upper body looks thick", they were D2, D4, F8, C3 and A5 in order whild in "Upper body looks thin", they were A1, F5, and D7 in order. 6. In the item "Lower body lookds thick", they were F9, C2, E3, B3, and D3 in order. In "Lower body looks thin", the best one was C1, and then D1, E2, F6, and F8 comes in order. 7. In "whole body looks thick", they were F9, F3, D3, and A5, and in "Whole body looks thin", they were F5, A1, C1, and D6 in order. 8. In "Height looks tall", the effects were in order of A4, D6, E1, and F7 while in "Height looks short", they were E3, F9, B4, D2, and D1. 8. In "Height looks tall", the effects were in order of A4, D6, E1, and F7 while in "Height looks short", they were E3, F9, B4, D2, and D1. F9, B4, D2, and D1.

  • PDF

Utility of Wide Beam Reconstruction in Whole Body Bone Scan (전신 뼈 검사에서 Wide Beam Reconstruction 기법의 유용성)

  • Kim, Jung-Yul;Kang, Chung-Koo;Park, Min-Soo;Park, Hoon-Hee;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.83-89
    • /
    • 2010
  • Purpose: The Wide Beam Reconstruction (WBR) algorithms that UltraSPECT, Ltd. (U.S) has provides solutions which improved image resolution by eliminating the effect of the line spread function by collimator and suppression of the noise. It controls the resolution and noise level automatically and yields unsurpassed image quality. The aim of this study is WBR of whole body bone scan in usefulness of clinical application. Materials and Methods: The standard line source and single photon emission computed tomography (SPECT) reconstructed spatial resolution measurements were performed on an INFINA (GE, Milwaukee, WI) gamma camera, equipped with low energy high resolution (LEHR) collimators. The total counts of line source measurements with 200 kcps and 300 kcps. The SPECT phantoms analyzed spatial resolution by the changing matrix size. Also a clinical evaluation study was performed with forty three patients, referred for bone scans. First group altered scan speed with 20 and 30 cm/min and dosage of 740 MBq (20 mCi) of $^{99m}Tc$-HDP administered but second group altered dosage of $^{99m}Tc$-HDP with 740 and 1,110 MBq (20 mCi and 30 mCi) in same scan speed. The acquired data was reconstructed using the typical clinical protocol in use and the WBR protocol. The patient's information was removed and a blind reading was done on each reconstruction method. For each reading, a questionnaire was completed in which the reader was asked to evaluate, on a scale of 1-5 point. Results: The result of planar WBR data improved resolution more than 10%. The Full-Width at Half-Maximum (FWHM) of WBR data improved about 16% (Standard: 8.45, WBR: 7.09). SPECT WBR data improved resolution more than about 50% and evaluate FWHM of WBR data (Standard: 3.52, WBR: 1.65). A clinical evaluation study, there was no statistically significant difference between the two method, which includes improvement of the bone to soft tissue ratio and the image resolution (first group p=0.07, second group p=0.458). Conclusion: The WBR method allows to shorten the acquisition time of bone scans while simultaneously providing improved image quality and to reduce the dosage of radiopharmaceuticals reducing radiation dose. Therefore, the WBR method can be applied to a wide range of clinical applications to provide clinical values as well as image quality.

  • PDF

Effects of Vegetative Buffers on Reducing Soil Erosion and Nutrient Loss of Highland Field in Korea (고랭지밭의 토양침식 저감을 위한 완충식생대의 효과)

  • Jin, Yong-Ik;Lee, Jeong-Tae;Lee, Gye-Jun;Hwang, Seon-Woong;Zhang, Yong-Seon;Park, Chang-Young;Seo, Myung-Chul;Ryu, Jong-Soo;Jeong, Jin-Cheol;Chung, Ill-Min
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.4
    • /
    • pp.231-238
    • /
    • 2009
  • This study was carried out to investigate the effect of vegetative buffer to reduce runoff and soil and nutrient loss at highland agricultural area. The soil of experimental field was classified as Ungyo series (Fine, Humic Hapludults). An area of each field with lysimeter was $50m^2(width\;2.5m{\times}length\;20m)$ and was a gradient of 17%. Chinese cabbage (Brassica campestris L.) was cultivated by general management in each field. For establishing vegetative buffer, rye (Secalecereale L.), tall fescue (Festucaarundinacea Schreb) and orchard grass (Dactylis glomerata L.) were planted at the edge of field. Rye buffers were 1m, 2m and 4m wide. Both orchard grass and tall fescue buffers were 2m wide. Vegetative buffers were set up in September 2005 and chinese cabbage was planted in June 2006. Soil loss, runoff and nutrient loss were measured from June to August in 2006. Since the precipitation amount was heavy in July, amounts of runoff, soil erosion and nutrient loss were the highest in July during this study period. In comparison with control, vegetative buffers of rye 2m, orchard grass 2m and tall fescue 2m reduced runoff by 3%, 1% and 2%, respectively. In comparison among width of rye buffer, rye 1m, rye 2m, and rye 4m reduced by 1%, 4% and 13%, respectively. Vegetative buffers of rye 2m, orchard grass 2m and tall fescue 2m showed the reducing of soil loss by 59%, 46% and 28%, respectively. In comparison among width of rye buffer, the highest reducing effect of 88% was observed in 4m treatment. Additionally, vegetative buffer reduced N, P and K losses in runoff and eroded soil which were 10 to 54%, 7 to 24% and 11 to 21%, respectively. In different widths, wider vegetative buffer showed lower loss of N, P and K in runoff and eroded soil. As a result of this study, the vegetative buffer of rye was most effective for reducing runoff and soil loss in comparisons with other plants. In addition, wider range of buffers recommended for reducing runoff and soil loss, if possible.

Longitudinal Pattern of Large Wood Distribution in Mountain Streams (산지계류에 있어서 유목의 종단적 분포특성)

  • Seo, Jung Il;Chun, Kun Woo;Kim, Min Sik;Yeom, Kyu Jin;Lee, Jin Ho;Kimura, Masanobu
    • Journal of Korean Society of Forest Science
    • /
    • v.100 no.1
    • /
    • pp.52-61
    • /
    • 2011
  • Whereas recent researches have elucidated the positive ecological roles of large wood (LW) in fishbearing channels, LW is also recognized as a negative factor of log-laden debris flows and floods in densely populated areas. However in Republic of Korea, no study has investigated longitudinal variations of LW distribution and dynamic along the stream corridor. Hence to elucidate 1) physical factors controlling longitudinal distribution of LW and 2) their effect on variation in LW load amount, we surveyed the amount of LW with respect to channel morphology in a mountain stream, originated from Mt. Ki-ryong in Inje, Gangwondo. Model selection in the Generalized Linear Model procedure revealed that number of boulder (greater than or equal to 1.0 m in diameter), bankfull channel width and their interaction were the best predictors explaining LW load volume per unit channel segment area (unit LW load). In general, boulders scattered within small mountain streams influence LW retention as flow obstructions. However, in this study, we found that the effect of the boulders vary with the channel width; that is, whereas the unit LW load in the segment with narrow channel width increased continuously with increasing boulder number, it in the segment with wide channel width did not depend on the boulder number. This should be because that, in two channels having different widths, the rates of channel widths reduced by boulders are different although boulder numbers are same. Our findings on LW load varying with physical factors (i.e., interaction of boulder number and channel width) along the stream corridor suggest understanding for longitudinal continuum of hydrogeomorphic and ecologic characteristics in stream environments, and these should be carefully applied into the erosion control works for systematic watershed management and subsequent disaster prevention.

Condition Assessment of Various Types of Road Cavities Using DEM (개별요소법을 활용한 도로하부 동공 상태 평가)

  • Kim, Yeonho;Park, Hyunsu;Kim, Byeongsu;Park, Seong-Wan
    • International Journal of Highway Engineering
    • /
    • v.18 no.5
    • /
    • pp.39-47
    • /
    • 2016
  • PURPOSES : Road subsidence occurs owing to road cavities, which cause many social and environmental problems, especially in cities. Recently, road cavities were detected by various ground radars and repair works were carried out against the detected cavities. The condition assessments related to the road cavities are necessary to understand the potential risk of the cavities. Therefore, in this study, a numerical study was performed to assess the various conditions of road cavities. METHODS : The numerical method adopted in this study is the discrete element approach, and it is suitable for analyzing the condition because it can consider the movement of the soil particles in the surrounded cavity areas. In addition, the triaxial test was modeled and performed under various cavity conditions inside the specimens. RESULTS : The conditions of different cavity locations and shapes were analyzed to identify the effect of cavity state. Three general cases of particle size distributions were formulated to identify the effect of surrounding ground conditions. As a result, the degree of decrement and volumetric strain were varied depending on the locations and shapes of the cavity. Only minor changes were observed when the particle size distributions were altered. CONCLUSIONS : The strength reduction was higher when the cavity formed was larger and located in the upper zone. Similar to the cavity shape, strength reduction and volume deformation are more influenced by the width than the length of the cavities. There is an influence from ground conditions such as the particle size distribution, especially on the wide cavity.

Effect of Agitation on the in vitro Permeability of Xenobiotics across Caco-2 Cell Monolayers (Caco-2 세포 단층막 투과 실험시 교반이 약물의 투과계수에 미치는 염향)

  • Hong, Soon-Sun;Yoo, Ho-Jung;Li, Hong;Chung, Suk-Jae;Kim, Dae-Duk;Shim, Chang-Koo
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.2
    • /
    • pp.111-116
    • /
    • 2005
  • The unstirred water layer (UWL), which has been known to exist in the boundary of the intestinal lumen and intestinal wall, often behaves as an absorption barrier especially for lipophilic drugs. The intestinal absorption of drugs is often characterized using Caco-2 cell monolayers grown on Transwell polycarbonate membranes. The permeability $(P_{app})$ of drugs across the cell monolayer might be influenced by the agitation of the donor compartment, since the width of UWL on the surface of the cell monolayer would be reduced by the agitation. In this study, the effect of agitation of the donor compartment with 60 rpm on the permeability was measured for 12 drugs with a wide range of lipophilicity and permeability. The $P_{app}$ of mannitol, tributylmethyl ammonium, cimetidine, ranitidine, hydrocortisone, benzylpenicillin and loxoprofen was not influenced by the agitation, while the $P_{app}$ of theophylline, propranolol, YH439, phenylpropanolamine and testosterone was increased by the agitation. There was a significant correlation between the increase of $P_{app}$ by agitation and the lipophilicity for the compounds having $P_{app}>2{\times}10^{-5}$ cm/sec. No correlation was observed for the difference in $P_{app}$ by agitation and the molecular weight, or lipophilicity of the drugs. Therefore, the agitation rate of the donor compartment in the Caco-2 cell monolayer study should be carefully controlled in order to estimate $P_{app}$ reproducibly especially for lipophilic drugs.

A Study on Determining the Design Parameter ($N_c$, $T_i$) of the Surface Reinforcement Method for Soft Ground (연약지반 표층처리공법 설계정수(지지력계수$N_c$, 인장력$T_i$) 산정방법에 관한 고찰)

  • Ham, Tae-Gew;Seo, Se-Gwan;Cho, Sam-Deok;Yang, Kee-Sok;You, Seung-Kyong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.750-758
    • /
    • 2009
  • This study, as basic research which was intended to develope the surface reinforcement method using reinforcement material which is applicable to very soft ground in Korea, was aimed at proposing the design parameter for the surface ground improvement method. To that end, a wide width tensile test using geotextile, geogrid and steel bar (substitute for bamboo) and 25 kinds of the laboratory model tests with the end restraint conditions of the reinforcement that comprises the constrained and partially constrained (3 types) conditions were conducted. And the result indicated that the modulus of subgrade reaction or $N_c$ value (5.3) apparently overestimated the bearing capacity of very soft ground such as dredged ground. Moreover, as a result of model test by partially constraining the preload of 23.0kgf using geotextile, the effect of bearing capacity($q_1$) appeared to be the largest till the loading stress was $0.4tf/m^2$ due to cohesion, while it reached 75% of the maximum bearing force after $0.4tf/m^2$ due to increase in the effect of bearing capacity($q_2$) caused by the tensile force of the reinforcement. Such results tended to have appeared constantly or very similarly with each other, irrespective of the type of reinforcement (geogrid, steel bar) and constraint conditions.

  • PDF

Effect of etched microgrooves on hydrophilicity of titanium and osteoblast responses: A pilot study

  • Park, Jung-Ae;Lee, Sung-Bok Richard;Ahn, Su-Jin;Lee, Suk-Won
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.1
    • /
    • pp.18-24
    • /
    • 2010
  • PURPOSE. The aim of this pilot study was to investigate the effect of etched microgrooves on the hydrophilicity of Ti and osteoblast responses. MATERIAL AND METHODS. Microgrooves were applied on Ti to have 15 and $60{\mu}m$ width, and 3.5 and $10{\mu}m$ depth by photolithography, respectively. Further acid etching was applied to create Ti surfaces with etched microgrooves. Both smooth- and acid-etched Ti were used as the controls. The hydrophilicity of Ti was analyzed by determining contact angles. Cell proliferation and osteogenic activity of MC3T3 mouse preosteoblasts were analyzed by bromodeoxyuridine assay and alkaline phosphatase (ALP) activity test, respectively. One-way ANOVA, Pearson's correlation analysis and multiple regression analysis were used for statistics. RESULTS. Etched microgrooves significantly increased the hydrophilicity of Ti compared to the smooth Ti. $60{\mu}m$-wide etched microgrooves significantly enhanced cell proliferation, whereas the osteogenic activity showed statistically non-significant differences between groups. Result of the osteogenic activity significantly correlated with those of hydrophilicity and cell proliferation. Hydrophilicity was determined to be an influential factor on osteogenic activity. CONCLUSION. This study indicates that increase in hydrophilicity of Ti caused by etched microgrooves acts as an influential factor on osteogenic activity. However, statistically non-significant increase in the ALP activity suggests further investigation.

Correction of Beam Direction Error caused by Frequency Scan Effect in Active Phased Array Antenna for Satellite Communications (위성통신 능동 위상배열 안테나에서 주파수 스캔 효과로 발생하는 빔 지향 오차의 보상)

  • 전순익;오승엽
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.4
    • /
    • pp.413-420
    • /
    • 2003
  • In this paper, the correction method of antenna beam direction errors is introduced which caused by frequency scan effect in active Phased may antenna for satellite communications. The antenna makes the beam directional error from frequency scan effect when it has dual beam may structure with asymmetrical series connection, their frequencies are different and for from each other, their 3dB beamwidth is narrow, and scan range is wide. By proposed equations, estimated beam direction error angles can be calculated and active phase shifter control values also can be calculated to compensate them. In this paper, the active phased array antenna system was fabricated to measure beam direction errors both before and after correction, which has dual beam from 32${\times}$4 main level array and 4${\times}$2 second level array, frequency deviation 500 MHz max.(6.7 %) at 7.25 GHz∼7.75 GHz ranges, 0$^{\circ}$${\pm}$35$^{\circ}$nm ranges, and 35.6 dBi gain with 2.2$^{\circ}$3 dB beam width. Its beam direction error by frequency san effect which was 2.5$^{\circ}$max., was reduced to 0.2$^{\circ}$max. after correction. This was 7 dB improvement of signal loss. The active phased array antenna can accurately track the target satellite for communications by this proposed correction method.

The Comparison of Image Quality and Quantitative Indices by Wide Beam Reconstruction Method and Filtered Back Projection Method in Tl-201 Myocardial Perfusion SPECT (Tl-201 심근관류 SPECT 검사에서 광대역 재구성(Wide Beam Reconstruction: WBR) 방법과 여과 후 역투영법에 따른 영상의 질 및 정량적 지표 값 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Shim, Dong-Oh;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.122-127
    • /
    • 2010
  • Purpose: The Xpress3.$cardiac^{TM}$ which is a kind of wide beam reconstruction (WBR) method developed by UltraSPECT (Haifa, Israel) enables the acquisition of at quarter time while maintaining image quality. The purpose of this study is to investigate the usefulness of WBR method for decreasing scan times and to compare to it with filtered back projection (FBP), which is the method routinely used. Materials and Methods: Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on an equality with counts from patient's body. The Tl-201 concentrations in the compartments were 74 kBq (2 ${\mu}Ci$)/cc in myocardium, 11.1 kBq (0.3 ${\mu}Ci$)/cc in soft tissue, and 2.59 kBq (0.07 ${\mu}Ci$)/cc in lung. The non-gated Tl-201 myocardial perfusion SPECT data were acquired with the phantom. The former study was scanned for 50 seconds per frame with FBP method, and the latter study was acquired for 13 seconds per frame with WBR method. Using the Xeleris ver. 2.0551, full width at half maximum (FWHM) and average image contrast were compared. In clinical studies, we analyzed the 30 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center from January to April 2010. The patients were imaged at full time (50 second per frame) with FBP algorithm and again quarter-time (13 second per frame) with the WBR algorithm. Using the 4D MSPECT (4DM), Quantitative Perfusion SPECT (QPS), and Quantitative Gated SPECT (QGS) software, the summed stress score (SSS), summed rest score (SRS), summed difference score, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were analyzed for their correlations and statistical comparison by paired t-test. Results: As a result of the phantom study, the WBR method improved FWHM more than about 30% compared with FBP method (WBR data 5.47 mm, FBP data 7.07 mm). And the WBR method's average image contrast was also higher than FBP method's. However, in result of quantitative indices, SSS, SDS, SRS, EDV, ESV, EF, there were statistically significant differences from WBR and FBP(p<0.01). In the correlation of SSS, SDS, SRS, there were significant differences for WBR and FBP (0.18, 0.34, 0.08). But EDV, ESV, EF showed good correlation with WBR and FBP (0.88, 0.89, 0.71). Conclusion: From phantom study results, we confirmed that the WBR method reduces an acquisition time while improving an image quality compared with FBP method. However, we should consider significant differences in quantitative indices. And it needs to take an evaluation test to apply clinical study to find a cause of differences out between phantom and clinical results.

  • PDF