• Title/Summary/Keyword: well diffusion methods

Search Result 160, Processing Time 0.026 seconds

A Parameter Estimation of Bass Diffusion Model by the Hybrid of NLS and OLS (NLS와 OLS의 하이브리드 방법에 의한 Bass 확산모형의 모수추정)

  • Hong, Jung-Sik;Kim, Tae-Gu;Koo, Hoon-Young
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.37 no.1
    • /
    • pp.74-82
    • /
    • 2011
  • The Bass model is a cornerstone in diffusion theory which is used for forecasting demand of durables or new services. Three well-known estimation methods for parameters of the Bass model are Ordinary Least Square (OLS), Maximum Likelihood Estimator (MLE), Nonlinear Least Square (NLS). In this paper, a hybrid method incorporating OLS and NLS is presented and it's performance is analyzed and compared with OLS and NLS by using simulation data and empirical data. The results show that NLS has the best performance in terms of accuracy and our hybrid method has the best performance in terms of stability. Specifically, hybrid method has better performance with less data. This result means much in practical aspect because the avaliable data is little when a diffusion model is used for forecasting demand of a new product.

Membrane Diffusion through Flexible-Wall Permeameter for Soil Flushing Tests (연성벽체 투수기를 이용한 흙세척 실험시 벽막을 통한 확산량 산정)

  • Junboum Park;Jee-Sang Kim
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.2
    • /
    • pp.95-103
    • /
    • 1997
  • Solvent extraction using aqueous solutions is presumed as one of the most effective methods applicable to in situ conditions without excavation of contaminated soils. Laboratory permeameter soil flushing test is performed to describe the process of solvent extraction of contaminants absorbed on soil particles. When the permeameter tests conducted, diffusion of contaminants through the permeameter flexible-wall was considered for adjusting the remediation percentage. Input and output balance for concentration was well matched in the permeameter tests. Nitrobenzene diffused so excessively (approximately 75%) that it was not suitable for the permeameter desorption tests. No biodegradation was detected in the soil samples.

  • PDF

Thin-layer Drying Characteristics of Rapeseed

  • Lee, Hyo-Jai;Lee, Seung-Kee;Kim, Hoon;Kim, Woong;Han, Jae-Woong
    • Journal of Biosystems Engineering
    • /
    • v.41 no.3
    • /
    • pp.232-239
    • /
    • 2016
  • Purpose: The aims of this study were to define the drying characteristics of rapeseed and to determine the optimum thin-layer drying model for rapeseed by considering the effects of drying temperature and relative humidity. Methods: The thin-layer drying experiments were conducted at different combinations of drying air temperature levels of 40, 50, and $60^{\circ}C$ and relative humidity levels of 30, 45, and 60%, on both of which drying rate depends. The drying rate increased with increasing air temperature as well as decreasing relative humidity. The 13 models were fitted to the experimental data. Results: From the results of the regression analysis for empirical constants of the Page model, the values of $R^2$ were the highest (ranging from 0.9924 to 0.9966) and the values of RMSE were the lowest (ranging from 0.0169 to 0.0296). Conclusions: For all drying conditions considered, the Page model was determined to be the most suitable model for describing the thin-layer drying of rapeseed (P-value < 0.01). The moisture diffusion coefficients were calculated using the moisture diffusion equation for a spherical shape, based on Fick's second law.

A study on wear damage of SKD11 steel material for a cutting mold jig (SKD11 절단금형치구용 소재의 마모손상에 관한 연구)

  • Nam, Ki-Woo;Kim, Cheol-Su;Ahn, Seok-Hwan
    • Journal of Power System Engineering
    • /
    • v.20 no.5
    • /
    • pp.5-13
    • /
    • 2016
  • This study is on wear damage of the material for a molding machine that be used at finally cutting of metal beam made in roll forming process of vehicle bump beam process line. SKD11 steel was used with the material for cutting mold jig. In the cutting mold jig, Ti diffusion heat treatment after vacuum heat treatment was carried out for upgrade of surface hardness and anti-wear. Also, the heat treatments by various methods were performed to compare the wear damage degree against above the existing heat treatment. Wear loss and friction coefficient were obtained from wear test. And, micro Vickers hardness values were compared with damaged parts or not of cutting mold jig. Micro Vickers hardness value appeared higher at the undamaged part by Ti diffusion heat treatment. The micro Vickers hardness well followed a two-parameter Weibull probability distribution.

In Vivo Measurement of Site-Specific Peritoneal Solute Transport Using a Fiber-Optic-based Fluorescence Photobleaching Technique

  • Lee, Donghee;Kim, Jeong Chul;Shin, Eunkyoung;Ju, Kyung Don;Oh, Kook-Hwan;Kim, Hee Chan;Kang, Eungtaek;Kim, Jung Kyung
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.3
    • /
    • pp.228-236
    • /
    • 2015
  • Fluorescence recovery after photobleaching (FRAP) is a well-established method commonly used to measure the diffusion of fluorescent solutes and biomolecules in living cells or tissues. Here a fiber-optic-based FRAP (f-FRAP) system was developed, and validated using macromolecules in water and agarose gels of different concentrations. We applied f-FRAP to measure the site-specific diffusion of fluorescein (NaFluo) in peritoneal membranes (PMs) on the liver, cecum, and kidney of a living rat during peritoneal dialysis. Diffusion of fluorescein in PM varied in a time-dependent manner according to the type of organ ($D_{PM\;on\;Liver}/D_{NaFluo}=0.199{\pm}0.085$, $D_{PM\;on\;Cecum}/D_{NaFluo}=0.292{\pm}0.151$, $D_{PM\;on\;Kidney}/D_{NaFluo}=0.218{\pm}0.110$). The proposed method allows direct quantitative measurement of the three-dimensional diffusion in local PM in vivo, which was previously inaccessible by peritoneal function test methods such as peritoneal equilibration test (PET) and standardized PM assessment (SPA). f-FRAP is promising for local and dynamic assessments of peritoneal pathophysiology and the mass transport properties of PMs, presumed to be affected by variation of tissue structures over different organs and functional changes of the PM with years of peritoneal dialysis.

Vision and Developmental Tasks for Korea Agricultural Extension Services for the 21 st Century (21 세기 한국 농촌지도사업의 비전과 발전과제)

  • Lee, Soo-Chul;Lee, Chae-Shik
    • Journal of Agricultural Extension & Community Development
    • /
    • v.7 no.1
    • /
    • pp.101-119
    • /
    • 2000
  • Agricultural Extension Services in Korea have accomplished a significant role in self- sufficiency of rice, a national staple food, through green revolution in 1970's; supplying green vegetables even during the winter season through white revolution in 1980's; and establishing technical agriculture by organizing rural leaders and 4-H members. In 1990s changes were made in international situations under the Uruguay Round multilateral trade negotiations and inauguration of the World Trade Organization. This was followed by localization of the extension staffs and the functions of extension services in Korea changed dramatically from national government to local governments. Thus, a weakened national function resulted in loosening of the linkages of research and extension in central government and local extension offices. Difficulties were reported in diffusion of new agricultural technology and efficient management of extension personnel. Developmental tasks for better extension services for the 21st century in Korea would include recovering national functions of agricultural extension, and developing a new paradigm for extension service. This should include the following measures; 1) Cooperative extension service should be adapted to involve national as well as local governments and non-government organization. 2) The target groups for extension services should be expanded to include farmers, noel residents as well as urban consumers. 3) The role of the extension service should cover agricultural technological diffusion of innovations as well as managerial skills and leadership development for rural organizations. 4) Extension services should be introduced to small farmers as well as consultation services for advanced farms. Diversified approaches should be employed for mama effective services. 5) Pre-service as well as in-service education should be offered to secure better extension educators equipped with knowledge, understanding and abilities on agricultural technology, information, agricultural philosophy, instructional methods and communication skills.

  • PDF

comparison of Numercal Methods for Obtaining 2-D Impurity Profile in Semiconductor (반도체 내에서의 2차원 불순물 분포를 얻기 위한 수치해법의 비교)

  • Yang, Yeong-Il;Gyeong, Jong-Min;O, Hyeong-Cheol
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.3
    • /
    • pp.95-102
    • /
    • 1985
  • An efficient numerical scheme for assessing the two-dimensional diffusion problem for modelling impurity profile in semiconductor is described. 4 unique combination of ADI (Al-ternating Direction Bmplicit) method and Gauss Elimination has resulted in a reduction of CPU time for most diffusion processes by a factor of 3, compared to other iteration schemes such as SOR (Successive Over-Relaxation) or Stone's iterative method without additional storage re-quirement. Various numerical schemes were compared for 2-D as well as 1-0 diffusion profile in terms of their CPU time while retaining the magnitude of relative error within 0.001%. good agree-ment between 1-D and 2-D simulation profile as well as between 1-D simulation profile and experiment has been obtained.

  • PDF

Effect of Time-dependent Diffusion and Exterior Conditions on Service Life Considering Deterministic and Probabilistic Method (결정론 및 확률론적 방법에 따라 시간의존성 염화물 확산계수 및 외부 영향인자가 내구수명에 미치는 영향)

  • Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.6
    • /
    • pp.65-72
    • /
    • 2016
  • Service life evaluation for RC Structures exposed to chloride attack is very important, however the previous two methods(deterministic and probabilistic method) show a big difference. The paper presents a service life simulation using deterministic and probabilistic method with time-dependent diffusion coefficient. Three different cases are considered for diffusion coefficient, concrete cover depth, and surface chloride content respectively, and then the PDF(probability of durability failure) and the related service life are obtained. Through adopting time-dependent diffusion, the discrepancy between the two methods can be reduced, which yields reasonable service life. When diffusion coefficient increases from $2.5{\times}10^{-12}m^2/sec$ to $7.5{\times}10^{-12}m^2/sec$, the service life decreases to 25.5~35.6% level, and cover depth does from 75 mm to 125 mm, it increases to 267~311% level as well. In the case of surface chloride content from $5.0kg/m^3$ to $15.0kg/m^3$, it changes to 40.9~54.5%. The effect of cover depth is higher than the others by 8~10 times and also implies it is a key parameter to service life extension.

A Study on Design and Manufacturing Methods of Dual-Polarization Monopulse Feed Structure in Millimeter-wave(W band) (밀리미터파(W대역) 이중편파 모노펄스 급전 구조 설계 및 제작 방안 연구)

  • Jong-Gyun Baek;Hyeong-Ki Lee;Young-Wan Kim;Hee-Duck Chae;Ji-Han Joo;Jaesik Kim
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.6
    • /
    • pp.47-53
    • /
    • 2023
  • In this paper, We designed a waveguide-type feed structure that converts millimeter wave dual-polarized signals into monopulse signals and presented a manufacturing method. At millimeter-wave such as the W band, the size of the waveguide is very small, making it very difficult to manufacture complex structures. Therefore, because manufacturability is important for the waveguide-type feed structure in the millimeter-wave, electro forming and diffusion bonding were proposed and verified in this study. The designed monopulse feed structure consists of eight 180° hybrids that combine 90° hybrids and self-compensating phase shifters, and four OMTs to separate dual polarization. The designed feed structure was designed to facilitate electro forming and diffusion bonding, and the manufactured feed structure was verified through a network analyzer. It was confirmed that the two proposed production methods produce a monopulse signal well through the measured magnitude and phase of the port.

Diffusion tensor imaging of the C1-C3 dorsal root ganglia and greater occipital nerve for cervicogenic headache

  • Wang, Lang;Shen, Jiang;Das, Sushant;Yang, Hanfeng
    • The Korean Journal of Pain
    • /
    • v.33 no.3
    • /
    • pp.275-283
    • /
    • 2020
  • Background: Previous studies showed neurography and tractography of the greater occipital nerve (GON). The purpose of this study was determining diffusion tensor imaging (DTI) parameters of bilateral GONs and dorsal root ganglia (DRG) in unilateral cervicogenic headache as well as the grading value of DTI for severe headache. The correlation between DTI parameters and clinical characteristics was evaluated. Methods: The fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values in bilateral GONs and cervical DRG (C2 and C3) were measured. Grading values for headache severity was calculated using a receiver operating characteristics curve. The correlation was analyzed with Pearson's coefficient. Results: The FA values of the symptomatic side of GON and cervical DRG (C2 and C3) were significantly lower than that of the asymptomatic side (all the P < 0.001), while the ADC values were significantly higher (P = 0.003, P < 0.001, and P = 0.003, respectively). The FA value of 0.205 in C2 DRG was considered the grading parameter for headache severity with sensitivity of 0.743 and specificity of 0.999 (P < 0.001). A negative correlation and a positive correlation between the FA and ADC value of the GON and headache index (HI; r = -0.420, P = 0.037 and r = 0.531, P = 0.006, respectively) was found. Conclusions: DTI parameters in the symptomatic side of the C2 and C3 DRG and GON were significantly changed. The FA value of the C2 DRG can grade headache severity. DTI parameters of the GON significantly correlated with HI.