• Title/Summary/Keyword: wearing experiment

Search Result 223, Processing Time 0.03 seconds

Use of an Electric Muscle Stimulation Thigh Band and High-intensity Circuit Training to Activate the Thigh Muscle (무릎 밴드를 이용한 EMS와 High-intensity Circuit Training의 대퇴근육 활성화 효과)

  • Hanna Park;Jinhee Park;Jooyong Kim
    • Journal of Fashion Business
    • /
    • v.27 no.2
    • /
    • pp.39-51
    • /
    • 2023
  • The purpose of this study was to effectively improve the thigh muscles of adult women working from home due to COVID-19. In this study, ten adult women working from home performed 1) an electromyography test, 2) a static balance test on a balance board, and a 3) dynamic balance test by squatting on a Bosu ball four times: before electric muscle stimulation (EMS), after EMS, after high-intensity circuit training (HICT), and after EMS plus HICT. For this test, EMS was attached to a medical knee support to manufacture an EMS knee band that could be easily worn regardless of the location. For the experiment, EMS(electric muscle stimulation) was attached to the medical knee protector to manufacture an EMS knee band that can be easily worn regardless of location, and was measured based on the right foot. The study results confirmed that in all tests (electromyography test, static balance test on the balance board, and dynamic balance test by squatting on a Bosu ball), thigh strength improved in the order of treatment before EMS, after EMS, after HICT, and after EMS plus HICT. The study showed that people working from home or with activity restrictions due to COVID-19 had better exercise effects when wearing the EMS knee band and performing HICT, even in a small space.

Microbe Pollution Condition on Soft Contact Lenses (소프트 콘택트렌즈에서의 미생물 오염양상)

  • Han, Sun-Hee;Park, Sung-Min;Yu, Tae-Shick
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.313-321
    • /
    • 2005
  • To know the pollution level concerning the microbes contamination condition in soft contact lenses, 2 experiments were operated with different methods. Firs experiment, we observed lenses surfaces through a scanning electronic microscope after pollution sort contact lenses with the suspensions of Staphylococcus aureus, Pseudomonas aeruginosa and Entrobacter aerogenes which can be major bacteria causing keratitis as wearing on soft contact lenses. As 1 hour after pollution with the soft contact lenses, we observed that many bacteria adhered to the lenses, and the pollution condition got worse with passing time increase(2, 4, 6, 12, and 24 hours, respectively). At 12 hours lapse of polluting soft contact lenses with P. aeruginosa, some bacteria adhered to the lenses. And as 24 hours lapsed after pollution soft lenses with E. aerogenes, bacteria adhered to them, and atypical substance was observed some of the surface of lenses. Second experiment, we observed the microbe pollution condition in soft contact lenses by let 21 people in twenties(men & women), who doesn't eye disorders, wear soft contact lenses during 4 hours. As the result, many kinds of bacterium and fungus were observed, and especially, the bacteria could be identified with their colors and the shapes of colony, so we found that single type, two types, and three types of bacteria adhered to their lenses.

  • PDF

Effect of the Shape and Attached Position of Fabric Sensors on the Sensing Performance of Limb-motion Sensing Clothes (직물 센서의 모양과 부착 위치가 사지 동작 센싱 의류의 센싱 성능에 미치는 영향)

  • Cho, Hyun-Seung;Yang, Jin-Hee;Jeon, Dong-Jin;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.20 no.3
    • /
    • pp.141-150
    • /
    • 2017
  • The purpose of this study was to analyze the effect of the shape and attached position of E-textile-based stretchable sensors on motion-sensing performance and to investigate the requirements for the optimal structure of clothes for sensing limb motions. An experimental garment was prepared with different sensor shapes, and attachment positions. A child subject, wearing the experimental garment, performed arm and leg bending and extension motions at $60^{\circ}$, $90^{\circ}$ and $120^{\circ}$ motion angles, at a rate of 60 deg/sec. The changes in voltage triggered by the stretching and contracting of the fabric-sensor were measured, and an acceleration sensor was utilized to verify that the experimental motions were correctly performed. Dummy arms and legs of a child were manufactured to perform an identical test, in order to compare the dummy results with the actual human body experiment results. The analysis showed that the reproducibility and reliability of the rectangular sensor, showing uniform and stable were higher than those of the boat-shaped sensor, in both the dummy and the human body experiments. The attachment position of the sensor was more reproducible and reliable when placed on 4 cm below the elbow and knee joints in the dummy test, when placed in the joints of the elbow and knee, in children experiment. The appropriate shapes and attached positions of the sensor for sensing the motions were analyzed, and the results proved that motion-sensing of the human body is possible by utilizing flexible fabric-sensors integrated into clothes.

The Study of Plate Powder Coated Nano Sized ZnO Synthesis and Effect of Sensory Texture Improvement (나노 ZnO 입자가 코팅된 판상 분체의 합성과 사용감 증진 효과에 대한 연구)

  • Jin-Hwa , Lee;Ju-Yeol, Han;Sang-Gil, Lee;Hyeong-Bae, Pyo;Dong-Kyu, Lee
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.30 no.2
    • /
    • pp.173-180
    • /
    • 2004
  • Nano sized ZnO particle as 20-30nm applies for material, pigments, rubber additives, gas sensors, varistors, fluorescent substance as well as new material such as photo-catalyst, sensitizer, fluorescent material. ZnO with a particle size in the range 20-30nm has provided to be an excellent UV blocking material in the cosmetics industry, which can be used in sunscreen product to enhance the sun protection factor and natural makeup effect. But pure ZnO particles application limits for getting worse wearing feeling. We make high-functional inorganic-composite that coated with nano-ZnO on the plate-type particle such as sericite, boron nitride and bismuthoxychloride. In this experiment, we synthesized composite powder using hydrothermal precipitation method. The starting material was ZnCl$_2$ Precipitation materials were used hexamethylenetetramine(HMT) and urea. We make an experiment with changing as synthesis factors that are concentrations of starting material, precipitation materials, nuclear formation material, reaction time, and reaction temperature. We analyzed composite powder's shape, crystallization and UV-blocking ability with FE-SEM, XRD, FT-IR, TGA-DTA, In vitro SPF test. The user test was conducted by product's formulator. In the results of this study, nanometer sized ZnD was coated regardless of the type of plate-powder at fixed condition range. When the coated plate-powders were applied in pressed powder product, the glaze of powder itself decreased, but natural make-up effect, spreadability, and adhesionability were increased.

Development of New Hanbok Cheollik One Piece Prototype

  • Cha, Su-Joung;An, Myung-Sook;Heo, Seung-Yeun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.10
    • /
    • pp.125-137
    • /
    • 2021
  • This study was intended to develop a prototype of new Hanbok Cheollik one-piece based on design extracted through a preference survey on new Hanbok Cheollik one-piece. Through this, it was intended to provide information on patterns that are fundamental to the production of new Hanbok Cheollik one piece. The pattern of the experiment was produced by modifying D pattern, which was selected as excellent in the comparison of commercial Cheollik one-piece patterns. The SPSS 26.0 program was used to analyze the appearance evaluation of patterns. As a result of the 1st evaluation of appearance and garment pressure, the shoulder, sleeve length, skirt length and sleeve width required modification, reducing the sleeve length by 8.0cm and the sleeve width by 1.0cm in total. The length of the skirt was reduced by 5.0cm and the shoulder end point was reduced by 0.5cm on both sides to modify the shoulder width. As a result of the 2nd evaluation, the waist area, sleeve width, and skirt wrinkles were required to be corrected, reducing 2.0 cm waist width and 1.0 cm sleeve width and removing wrinkles on the front center and side area. The final pattern was highly appreciated. In future studies, it is thought that research should be conducted through study of Cheollik one-piece pattern according to material and age and the actual wearing experiment according to fabric and age.

Utility Estimation of the Manufactured Stereotactic Body Radiotherapy Immobilization (자체 제작한 정위적체부방사선치료(Stereotactic Body Radiotherapy) 고정용구의 유용성 평가)

  • Lee, Dong-Hoon;Ahn, Jong-Ho;Seo, Jeong-Min;Shin, Eun-Hyeok;Choi, Byeong-Gi;Song, Gi-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • Purpose: Immobilizations used in order to maintain the reproducibility of a patient set-up and the stable posture for a long period are important more than anything else for the accurate treatment when the stereotactic body radiotherapy is underway. So the purpose of this study is to adapt the optimum immobilizations for the stereotactic body radiotherapy by comparing two commercial immobilizations with the self-manufactured immobilizations. Materials and Methods: Five people were selected for the experiment and three different immobilizations (A: Wing-board, B: BodyFix system, C: Arm up holder with vac-lock) were used to each target. After deciding on the target's most stable respiratory cycles, the targets were asked to wear a goggle monitor and maintain their respiration regularly for thirty minutes to obtain the respiratory signals. To analyze the respiratory signal, the standard deviation and the variation value of the peak value and the valley value of the respiratory signal were separated by time zone with the self-developed program at the hospital and each tie-downs were compared for the estimation by calculating a comparative index using the above. Results: The stability of each immobilizations were measured in consideration of deviation changes studied in each respiratory time lapse. Comparative indexes of each immobilizations of each experimenter are shown to be A: 11.20, B: 4.87, C: 1.63 / A: 3.94, B: 0.67, C: 0.13 / A: 2.41, B: 0.29, C: 0.04 / A: 0.16, B: 0.19, C: 0.007 / A: 35.70, B: 2.37, C: 1.86. And when all five experimenters wore the immobilizations C, the test proved the most stable value while four people wearing A and one man wearing D expressed relatively the most unstable respiratory outcomes. Conclusion: The self-developed immobilizations, so called the arm up holder vac-lock for the stereotactic body radiotherapy is expected to improve the effect of the treatment by decreasing the intra-fraction organ motions because it keeps the respiration more stable than other two immobilizations. Particularly in case of the stereotactic body therapy which requires the maintenance of set-up state for a long time, the self-developed immobilizations is thought to more useful for stereotactic body radiotherapy rather than the rest two immobilizations with instable respiratory cycle as time passes.

  • PDF

The Effect of the Optical Points Difference between Finished-Reading Glasses and Dispensing Reading Glasses (완성품 돋보기와 조제가공된 돋보기가 광학적 요소에 미치는 영향)

  • Shim, Young-Cheol;Yoo, Gun-Chang;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.65-71
    • /
    • 2008
  • Purpose: This paper studied the effect of eyes on the comparison between the distance optical centers problem of dispensing reading glasses made by optician and finished reading glasses in the current market. Methods: The method of this study has been measured by eleven different categories from +1.00D to +4.00D. This study also separated into three groups by their optical frame size and measured optical center point (O.C) and optical center height (O.H) with 200 peoples of man and females over 40 years old without ocular disease living in Gwang-san gu, Gwang-Ju city. Results: As a result, optical center point ranged from 57 mm to 80 mm and it turned to be most common range is from 61 mm to 65 mm (64.6%). Moreover, the optical center height ranged from 1 mm to 8mm and most common ranged (23%) were 4 mm. In other words, finished reading glasses have irregular optical ranges. After observing 200 people who are over 40 years old men and women, result shows that more than 75.5% (151 people) currently use finished reading glasses. Survey of 151 people, most common error between the finished reading glasses's O.C and the wearers P.D were 4 mm (45%). Furthermore, the most common error between the finished reading glassses's O.H and the wearers O.H ranged from 3 mm to 4 mm. Astonishingly, the entire 151 people who wear finished reading glasses appeal that they feel tiredness on their eyes when they wear finished reading glasses. 53 people (35%) claimed that they feel tiredness on their eyes after 10 to 20 minutes wearing finished reading glasses. Base on the research, We conducted more experiment to find the value of prism of optical centers err because it will tell us whether the finished reading glasses are good enough to wear or not. We multiplied diopter by the difference between finished reading glasses's O.C. and wearer's P.D. Consequently, We found out that the finished reading glasses counter to the German RAL-RG 915 policy. And We also found that it is relative to the diopter of lenses. In conclusion, based on the researched that wearing finished reading glasses have a dangerous factor for our vision. Therefore optician must need to recommend correctly made dispensing reading glasses based on the optical center point.

  • PDF

Thermo-physiological Responses of the Lower Grade Elementary School Children -A Comparison Between Japanese and Korean Children- (초등학교 저학년 아동의 체온조절반응 -일본아동과 한국아동의 비교-)

  • Kim Seong-Hee;Lee Uk-Ja;Tamura Teruko
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.12 s.148
    • /
    • pp.1527-1534
    • /
    • 2005
  • In order to clarify the characteristics of the thermo-physiological responses of the child and to understand the influence of the country where the child has grown up on the responses, the thermo-physiological responses of the Japanese children(J group) and the Korean children(K group) were examined. The subject wearing shorts was exposed first to a thermo neutral room$(Ta=28.5^{\circ}C)$ for 1 hour, then transferred to a cold$(Ta=22^{\circ}C)$ or a hot$(Ta=37^{\circ}C)$ room for 1 hour. The experiment was done in the climate chamber of Bunka Women's University in the summer of 1997 for Japan, and in the climate chamber in the Keimyung University in the summer of 1998 for Korea. The subjects consisted of 5 boys and 5 girls aged 7-9 years in Japan and 4 boys and 4 girls aged 7-9 years in Korea. As a result: 1) The rectal temperature increased slightly with a rise in air temperature. K group showed a slightly higher rectal temperature. 2) The skin temperature of the hand and foot decreased conspicuously during cold exposure. It was more in the K group than in the J group. 3) Relative local sweat rates were similar in the two groups at $22^{\circ}C\;and\;28.5^{\circ}C$, while they were considerably different at $37^{\circ}C$. Even perspiration was observed over the whole body in the J group but the perspiration was large in the trunk and low in the extremity in the K group. 4) The heart rate was higher in the J group than in the K group but it increased with the rise of the air temperature in both groups.

Effects of Induced Microcurrent Shoes on Change of Blood Circulation to patients with Chronic Plantar (미세전류발생 신발 착용이 만성 족저근막염 환자의 혈류량 변화에 미치는 영향)

  • Lee, Yoon-Mi;Choi, Sang-Joon;Cheng, Goh Ah;Cho, Mi-Suk;Cho, Jeong-Sun;Cho, Yong-Ho;Park, So-Hyun;Park, Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.3
    • /
    • pp.71-78
    • /
    • 2006
  • Purpose: The purpose of this study was to investigate how induced microcurrent shoes influenced changes of the blood circulation in patients with Plantar Fasciitis. Methods: Initially, the subjects were comprised of 5 males and 5 females, who agreed with this research and are more than fifty years old, but 4 of those were dropped during the experiment. They all have plantar fasciitis and pain on their feet. Subjects wore the induced microcurrent shoes for more than 4 hours everyday during 4 weeks. When they wore those shoes, they also wore the specially produced shocks made of silver-mixed thread and they were asked to avoid intense exercise. Assessments were carried out before and after walking on a treadmill and we measured changes between the test before and after 4 weeks. In the examination of the before test, general shoes were used, and in the examination of the after test, induced microcurrent shoes were used. Temperature difference was measured by thermograpy DOREX spectrum 9000MB(USA). Subjects walked total 20 minutes and during gait, the walking rate on a treadmill was increased from 2Km/h to 3Km/h after 10 minutes. We measured plantar temperature by thermograpy especially both heel, 1st, and 5th metatarsal areas. Results: Firstly, in comparison of the blood circulation on the left and right foot at 0 week and 4 weeks, it tended toward increasing blood circulation but there was. no statistically significant difference (p>0.05). Secondly, in comparison of the blood circulation before and after treadmill with the induced microcurrent shoes, the blood circulation of the heel and the 5th area on the right foot was increased to all subjects(p<0.05). Conclusion: The results of this study revealed that subjects showed tendency to increase blood circulation in both right and left feet after wearing microcurrent shoes and specially after walking treadmill at 4 weeks. Therefore induced microcurrent shoes are useful to improve blood circulation for patients with plantar fasciitis.

  • PDF

Development of Wearable Sensing and Feedback Product Design for Movement Monitoring (동작 모니터링을 위한 웨어러블 센싱 및 피드백 제품 디자인 개발)

  • Cho, Hyun-Seung;Yang, Jin-Hee;Lee, Kang-Hwi;Lee, Jeong-Hwan;Park, Su-Youn;Choi, Hyeong-Ik;Jeon, Hak-Su;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.3
    • /
    • pp.165-176
    • /
    • 2018
  • The objective of this study was to develop clothing-type wearable motion sensing and feedback systems to enhance children's sports by promoting visual and audio feedback. In this study, several applications, such as fabric sensors, sportswear integrated with various types of fabric sensors, and fabric-based motion sensing module design, as well as a visual and audio feedback system for gaining a better understanding of a child's interest in a type of exercise, were developed. An SWCNT-based stretchable fabric sensor was developed for motion sensing, and sportswear was designed using the fabric sensor that was integrated into the limbs of the garment. The sensing module was developed, and sensory performance was evaluated through a joint motion experiment for children. In addition, using the feedback system that was developed in the form of an accessory, the responses of light and sound were also examined based on the movement of the child who was wearing the sportswear prototypes. This study focused on the development and assessment of prototype designs for children's sportswear and accessory products that can help to ascertain a child's interest in a particular exercise.