• Title/Summary/Keyword: wearable robot

Search Result 130, Processing Time 0.026 seconds

Clinical Feasibility of Wearable Robot Orthosis on Gait and Balance Ability for Stroke Rehabilitation: A Case Study

  • Shin, Young-Il;Yang, Seong-Hwa;Kim, Jin-Young
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.2
    • /
    • pp.124-127
    • /
    • 2015
  • Purpose: The emphasis on gait rehabilitation after stroke depends on training support through the lower limbs, balance of body mass over the changing base of support. However, muscle weakness, lack of control of lower limb, and poor balance can interfere with training after stroke. For this case study report, a wearable robot orthosis was applied to stroke patients in order to verify its actual applicability on balance and gait ability in the clinical field. Methods: Two stroke patients participated in the training using the wearable robot orthosis. Wearable robot orthosis provides patient-initiated active assistance contraction during training. Training includes weight shift training, standing up and sitting down, ground walking, and stair up and down Training was applied a total of 20 times, five times a week for 4 weeks, for 30 minutes a day. Gait ability was determined by Stance phase symmetry profile, Swing phase symmetry profile, and velocity using the GAITRite system. Balance ability was measured using the Biodex balance system. Results: Subjects 1, 2 showed improved gait and balance ability with mean individual improvement of 72.4% for velocity, 19.4% for stance phase symmetry profile, 9.6% for swing phase symmetry profile, and 13.6% for balance ability. Conclusion: Training utilizing a wearable robot orthosis can be useful for improvement of the gait and balance ability of stroke patients.

Design and Control of a Wearable Robot (Wearable Robot Arm의 제작 및 제어)

  • Jeong, Youn-Koo;Kim, Yoon-Kyong;Kim, Kyung-Hwan;Park, Jong-Oh
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.277-282
    • /
    • 2001
  • As human-friendly robot techniques improve, the concept of the wearability of robotic arms becomes important. A master arm that detects human arm motion and provides virtual forces to the operator is an embodied concept of a wearable robotic arm. In this study, we design a 7 DOF wearable robotic arm with high joint torques. An operator wearing this robotic arm can move around freely because this robotic arm was designed to have its fixed point at the shoulder part of the operator. The proposed robotic arm uses parallel mechanisms at the shoulder part and the wrist part on the model of the human muscular structure of an upper limb. To reduce the computational load in solving the forward kinematics and to prevent singularity motions of the parallel mechanism, yawing motion of the parallel mechanisms was separated using a slip ling mechanism. The total weight of the proposed robotic arm is about 4 kg. An experimental result of force tracking test for the pneumatic control system and an application example for VR robot are described to show the validity of the robot.

  • PDF

Research on Technology Status and Development Direction of Wearable Robot (웨어러블 로봇의 기술 현황 조사 및 개발 방향 제안 연구)

  • Kim, Hye Suk;Koo, Da Som;Nam, Yun Ja;Cho, Kyu-Jin;Kim, Seonyoung
    • Fashion & Textile Research Journal
    • /
    • v.21 no.5
    • /
    • pp.640-655
    • /
    • 2019
  • Technology status was investigated by analyzing patents and development cases of wearable robots. Development direction of wearable robot for wearability was also suggested by understanding the problems of wearability from development cases through the FGI technique. The number of patents per technical field was the most in the field of strength support, but AI in the technology field was different in each country; Korea was found to be poor in the category of daily living assistance. The number of patents by technology category was the most in the category of muscular strength assistance. However, the values of AI in the technology category were different in each country; Korea was found to be poor in the category of daily living assistance. Development cases were focused on rehabilitation, so development is not fulfilled uniformly by use purpose. By wearing body parts, robots with single function type were mainly developed. Rigid material robots were mainly developed. It was confirmed that wearable robot technology is not developed evenly in the category of application because it is in the early stage of the technical proposal and centered on main performance improvement. We derived twelve wearable conditions for wearable robots: Shape and Size Appropriateness, Movement Appropriateness, Composition Appropriateness, Physiological Appropriateness, Performance Satisfaction, Ease of Operation, Safety, Durability, Ease of Dressing, Ease of Cleaning, Portability and Ease of Storage and Appearance Satisfaction. Finally, the development direction of a wearable robot for each wearable condition was suggested.

Development of Soft Wearable Robot for Assisting Supination and Pronation of Forearm (전완의 회외 및 회내를 보조하는 유연한 착용형 로봇 개발)

  • Kyu Bum Kim;Jihun Park;Kyu-Jin Cho
    • The Journal of Korea Robotics Society
    • /
    • v.18 no.4
    • /
    • pp.359-366
    • /
    • 2023
  • In order to fully utilize the functions of the hand which is the end effector of the upper limb, other parts of the upper limb have to perform their own roles. Among them, the pronation and supination of the forearm, which allows the hand to rotate along the longitudinal direction of the forearm, play an important role in activities of daily living. In this paper, a soft wearable robot that assists the pronation and supination of the forearm for individuals with weakened or lost upper limb function is proposed. The wearable robot consists of an anchoring part with polymer (wrist strap, elbow strap), a tendon with a belt and wire, and an actuation module. It was developed based on the requirements with respect to friction of anchoring part, forearm compression, and friction of the tendon. It was confirmed that these requirements were satisfied through literature review and experiments. Since all components exist within the forearm when worn, it is expected to be easy to combine with the already developed soft wearable robots for the hand, wrist, elbow, and shoulder.

A Study of wearable robot styling for the support a industrial work force assistance (산업용 착용식 근력 증강 로봇 스타일링 연구)

  • Stone, Daniel;Kim, Hyung Joo;Bae, Hyunki
    • The Journal of Korea Robotics Society
    • /
    • v.9 no.2
    • /
    • pp.79-95
    • /
    • 2014
  • We are at the dawn of a new era in which the importance of robots will be evaluated on the basis of not only their functions but also their appearance. Therefore, those manufacturers who continue to develop robots that only offer convenience and do not keep up with the emerging trends might be weeded out from the robot market in the future. This study empirically tested and verified the ways in which the commercial value of wearable robots is enhanced when they are stylishly attired, using user and work environment analysis. For the purpose of this study, a styling development project for wearable robots was undertaken and applied to the actual development of these robots. Based on the results of the study, a new styling process for such robots was established. Those manufacturers who will realize the importance of styling of robots and develop robots using this process shall become the trendsetters in designing stylized robots and lead the robot industry in the future.

Analysis of the Gait Characteristics and Usability after Wearable Exoskeleton Robot Gait Training in Incomplete Spinal Cord Injury Patients with Industrial Accidents: A Preliminary Study

  • Bae, Young-Hyeon;Kim, Sung-Shin;Lee, Anna;Fong, Shirley S.M.
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.2
    • /
    • pp.235-244
    • /
    • 2022
  • Objective: The aim of this study was to investigate of the foot plantar pressure and usability after gait training using the ExoAtlet wearable exoskeleton robot in an incomplete spinal cord injury (SCI) patient. Design: A case study Methods: Six participants with an asymmetry in motor and sensory function completed the gait training using ExoAtlet wearable exoskeleton robot for 15 sessions, five per weeks, 3weeks. They were divided into two groups (low and high strength group) and group differences were evaluated about session at stating of gait, gait distance at final session and foot plantar pressures and useability after training. Results: Low strength group was faster than high strength group on adaptation of robot gait. And high strength group increased faster than low strength group on the gait distance during training. In standing and gait, weaker leg was higher than stronger leg on mean foot plantar pressure in low strength group. And stronger leg was higher than weaker leg on foot plantar pressure in high strength group. The length of the anterior-posterior trajectory of the center of pressure during gait was similar in low strength group, but different in high strength group. useability was positive about ExoAtlet wearable exoskeleton gait after training. Conclusions: ExoAtlet wearable exoskeleton robot gait training was positive about improving gait in all participants regardless of differences in severity of symptoms and gait abnormalities.