• Title/Summary/Keyword: wavelength monitoring

Search Result 209, Processing Time 0.035 seconds

KaVA and EAVN large program on two Supermassive Black Holes, Sgr A∗ and M87

  • Sohn, Bong Won;Kino, Motoki
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.52.1-52.1
    • /
    • 2019
  • Exploring the vicinity of super-massive black holes (SMBHs) is one of the frontiers in astrophysics. KaVA AGN Science WG has launched its Large Program in 2014 focusing on two SMBHs, Sgr A∗ and M87. They are selected based on their large apparent size. Sgr A∗ is the excellent laboratory for studying gas accretion process onto SMBH and M87 is well known as the best case for investigating plasma outflow ultimately driven by SMBH. For Sgr A∗, KaVA and EAVN provides superb UV-coverage on its emitting region and its scattering medium. In the case of M87, we have conducted high cadence dual-frequency (22and 43GHz )VLBI monitoring to clarify the global profile of the M87 jet velocity field and the spectral index map, which should reflect global structure of magnetic fields in the jet. From 2017, the AGN LP is recognized as multi-wavelength EHT project, conducting quasi-simultaneous coherent observations of M87 and Sgr A∗ with the Event Horizon Telescope (EHT) during its campaign observation periods. AGN WG is reviewing and revising its LP to convert it to EAVN LP. We will briefly report our scientific results and future plan which includes even broader international collaboration, namely East-Asia to Italy Nearly Global (EATING) VLBI to reach higher angular resolution.

  • PDF

Standard Calibration for Broadband and Narrowband Filters of KHAO 0.4 m Telescope

  • Ahn, Hojae;Jeong, Inhwan;Paek, Gregory S.H.;Lee, Sumin;Kim, Changgon;Pak, Soojong;Shim, Hyunjin;Im, Myungshin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.76.1-76.1
    • /
    • 2021
  • Maemi Dual Field Telescope System (MDFTS) is a dual telescope system located at Kyung Hee University. The system consists of 0.4 m telescope and 0.1 m telescope for wide-field observation. The 0.4 m telescope provides photometric observation which covers a field of view of 21'×16'. It has been used for various purposes with Johnson-Cousins UBVRI broadband filter system, e.g., SomangNet and Intensive Monitoring Survey of Nearby Galaxies. In this poster, we present the standard calibration result for our broadband filter system. Also, we suggest a new usage of the KHAO 0.4m telescope which is narrowband photometry by demonstrating the standard calibration of H-alpha filter. For flux calibration, not only R filter but also V filter is used for compensating the central wavelength discrepancy between R filter and H-alpha filter.

  • PDF

Evaluation of Signal Stability of Fiber Optic Sensors with respect to Sensor Packaging Methods in Long-Term Monitoring (장기 모니터링 환경에서 센서 패키징 방법에 따른 광섬유 센서의 신호 안정성 평가)

  • Kang, Donghoon;Kim, Heon-Young;Kim, Dae-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.4
    • /
    • pp.281-287
    • /
    • 2016
  • Fiber Bragg grating (FBG) sensors are applied in structural health monitoring (SHM) in various application fields because of their ease of multiplexing and capability of performing absolute measurements. Moreover, the packaging methods of FBG sensors accelerate their commercialization rapidly. However, long-term SHM exposes the FBG sensors to cyclic thermal loads, and a investigation is required because it finally leads to the signal instability of the FBG sensors. In this study, the effects of sensor packaging methods two methods are generally used for the FBGs: (bonding both sides of the FBG or bonding the FBG directly on signal stability of FBG sensors are investigated. Tests are conducted on specimens in a thermal chamber, over a temperature range from $-20^{\circ}C$ to $60^{\circ}C$ for 300 cycles. Signal characteristics such as Bragg wavelength, light intensity and full width at half maximum are examined and are compared with those of the FBG sensors, obtained in a previous study under direct bonding conditions. From the comparison, it is observed that the FBG sensors with bonding on both sides of the FBG demonstrate higher signal stabilities when exposed to cyclic thermal loads during long-term SHM. Consequently, it guarantees more effectiveness when packaging the FBG sensors.

Miniaturized λ/4 Folded Microstrip Antenna for Parking Monitoring Base Station System (주차장관리 시스템 기지국용 소형 λ/4 폴디드 마이크로스트립 안테나)

  • Keum, Jae-Min;Ko, Dong-Ok;Jeong, Jae-Yeop;Woo, Jong-Myung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.2
    • /
    • pp.95-101
    • /
    • 2016
  • In this paper, miniaturized ${\lambda}/4$ folded microstrip antennas is presented for parking monitoring base station system. The proposed antenna reduced a width of the radiating element for miniaturizing a size and we changed an aperture such as folded shape for reducing a length of the antenna by the pertubation effect by reducing a width of the antenna. Finally, the ${\lambda}/2$ length of the folded microstrip antenna to ${\lambda}/4$ folded microstrip antenna was miniaturized by reducing the length. The proposed antenna was designed to receive 425 MHz of center frequency that can be used without permission. Dimensions are $134mm{\times}143.85mm{\times}20.1mm$($0.19{\lambda}{\times}0.2{\lambda}{\times}0.028{\lambda}$, ${\lambda}$ is wavelength at 425 MHz) that are compared with basic microstrip patch antenna miniaturized 97.2%. Also, Measured -10 dB bandwidth was 2.44 MHz(0.57%). On the other hand, measured radiation patterns was 1.82 dBi at E-plane $15^{\circ}$.

Characterization of New Avalanche Photodiode Arrays for Positron Emission Tomography

  • Song, Tae-Yong;Park, Yong;Chung, Yong-Hyun;Jung, Jin-Ho;Jeong, Myung-Hwan;Min, Byung-Jun;Hong, Key-Jo;Choe, Yearn-Seong;Lee, Kyung-Han
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.45-45
    • /
    • 2003
  • The aim of this study was the characterization and performance validation of new prototype avalanche photodiode (APD) arrays for positron emission tomography (PET). Two different APD array prototypes (noted A and B) developed by Radiation Monitoring Device (RMD) have been investigated. Principal characteristics of the two APD array were measured and compared. In order to characterize and evaluate the APD performance, capacitance, doping concentration, quantum efficiency, gain and dark current were measured. The doping concentration that shows the impurity distribution within an APD pixel as a function of depth was derived from the relationship between capacitance and bias voltage. Quantum efficiency was measured using a mercury vapor light source and a monochromator used to select a wavelength within the range of 300 to 700 nm. Quantum efficiency measurements were done at 500 V, for which the APD gain is equal to one. For the gain measurements, a pencil beam with 450 nm in wavelength was illuminating the center of each pixel. The APD dark currents were measured as a function of gain and bias. A linear fitting method was used to determine the value of surface and bulk leakage currents. Mean quantum efficiencies measured at 400 and 450 nm were 0.41 and 0.54, for array A, and 0.50 and 0.65 for array B. Mean gain at a bias voltage of 1700 V, was 617.6 for array A and 515.7 for type B. The values based on linear fitting were 0.08${\pm}$0.02 nA 38.40${\pm}$6.26 nA, 0.08${\pm}$0.0l nA 36.87${\pm}$5.19 nA, and 0.05${\pm}$0.00 nA, 21.80${\pm}$1.30 nA in bulk surface leakage current for array A and B respectively. Results of characterization demonstrate the importance of performance measurement validating the capability of APD array as the detector for PET imaging.

  • PDF

Reflection Signal Analysis for Time Division Multiplexing of Fiber Optic FBG Sensors (광섬유 FBG 센서의 시간 분할 다중화를 위한 반사 신호의 분석)

  • Kim, Geun-Jin;Kwon, Il-Bum;Yoon, Dong-Jin;Hwang, Du-Sun;Chung, Young-Joo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.1
    • /
    • pp.6-12
    • /
    • 2010
  • Fiber optic sensor using fiber Bragg grating(FBG) probes is used for monitoring strain and temperature distributed on the wide surfaces of large structures. In this paper, in order to use many FBG probes in one optical fiber line, we propose a complex multiplexing technology which is composed of two techniques, one is time division multiplexing and another is wavelength division multiplexing. However, we only investigate the characteristics of time division multiplexing because FBG sensors basically can be operated by wavelength division multiplexing. We calculate the optimal reflectivities and the lengthwise location of five FBG probes in serial connection in order to obtain the unique reflected intensities from the FBG probes. We fabricate five FBG probes with the reflectivities of 13%, 16%, 25%, 40% and 80%, which are determined by the theoretical calculation, and observe the signal reflected from each FBG in the time domain from the experiment. There are differences between experimental and theoretical results caused by the signal noise and the differences of reflectivities of FBG probes. But the experimental results shows the reflected signals of five FBG probes which prove the availability of complex multiplexing.

Development of suspended solid concentration measurement technique based on multi-spectral satellite imagery in Nakdong River using machine learning model (기계학습모형을 이용한 다분광 위성 영상 기반 낙동강 부유 물질 농도 계측 기법 개발)

  • Kwon, Siyoon;Seo, Il Won;Beak, Donghae
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.2
    • /
    • pp.121-133
    • /
    • 2021
  • Suspended Solids (SS) generated in rivers are mainly introduced from non-point pollutants or appear naturally in the water body, and are an important water quality factor that may cause long-term water pollution by being deposited. However, the conventional method of measuring the concentration of suspended solids is labor-intensive, and it is difficult to obtain a vast amount of data via point measurement. Therefore, in this study, a model for measuring the concentration of suspended solids based on remote sensing in the Nakdong River was developed using Sentinel-2 data that provides high-resolution multi-spectral satellite images. The proposed model considers the spectral bands and band ratios of various wavelength bands using a machine learning model, Support Vector Regression (SVR), to overcome the limitation of the existing remote sensing-based regression equations. The optimal combination of variables was derived using the Recursive Feature Elimination (RFE) and weight coefficients for each variable of SVR. The results show that the 705nm band belonging to the red-edge wavelength band was estimated as the most important spectral band, and the proposed SVR model produced the most accurate measurement compared with the previous regression equations. By using the RFE, the SVR model developed in this study reduces the variable dependence compared to the existing regression equations based on the single spectral band or band ratio and provides more accurate prediction of spatial distribution of suspended solids concentration.

Rapid Detection of Radioactive Strontium in Water Samples Using Laser-Induced Breakdown Spectroscopy (LIBS) (Laser-Induced Breakdown Spectroscopy (LIBS)를 이용한 방사성 스트론튬 오염물질에 대한 신속한 모니터링 기술)

  • Park, Jin-young;Kim, Hyun-a;Park, Kihong;Kim, Kyoung-woong
    • Economic and Environmental Geology
    • /
    • v.50 no.5
    • /
    • pp.341-352
    • /
    • 2017
  • Along with Cs-137 (half-life: 30.17 years), Sr-90 (half-life: 28.8 years) is one of the most important environmental monitoring radioactive elements. Rapid and easy monitoring method for Sr-90 using Laser-Induced Breakdown Spectroscopy (LIBS) has been studied. Strontium belongs to a bivalent alkaline earth metal such as calcium and has similar electron arrangement and size. Due to these similar chemical properties, it can easily enter into the human body through the food chain via water, soil, and crops when leaked into the environment. In addition, it is immersed into the bone at the case of human influx and causes the toxicity for a long time (biological half-life: about 50 years). It is a very reductive and related with the specific reaction that makes wet analysis difficult. In particular, radioactive strontium should be monitored by nuclear power plants but it is very difficult to be analysed from high-cost problems as well as low accuracy of analysis due to complicated analysis procedures, expensive analysis equipment, and a pretreatment process of using massive chemicals. Therefore, we introduce the Laser-Induced Breakdown Spectroscopy (LIBS) analysis method that analyzes the elements in the sample using the inherent spectrum by generating plasma on the sample using pulse energy, and it can be analyzed in a few seconds without preprocessing. A variety of analytical plates for samples were developed to improve the analytical sensitivity by optimizing the laser, wavelength, and time resolution. This can be effectively applied to real-time monitoring of radioactive wastewater discharged from a nuclear power plant, and furthermore, it can be applied as an emergency monitoring means such as possible future accidents at a nuclear power plants.

Data Convergence of circular Array Correlative Interferometer Direction Finding with 7-Antenna (7-안테나로 구성된 원형배열 상관형 위상비교 방향탐지의 데이터 융합)

  • Lim, Joong-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • In this paper, we propose a new method for a correlative phase comparison direction finding(DF) which detects the arrival direction of radio waves by data fusing the calculated phase difference and the measured phase difference between the antennas when the radio waves are incident on the circular array antenna composed of 7 antennas respectively. The correlation type phase comparison method uses a uniform circular array(UCA) and a linear array method. The phase difference data calculated formally and the phase difference data measured in the test environment are fused with a correlation function, therefore, it is superior to the currently used phase comparison direction detection method. When the signal-to-noise ratio (SNR) of the received signal is 20dB and the inter-antenna distance to the wavelength of the received signal($L/{\lambda}$) is 0.5, the accuracy of the correlative DF is $1.7^{\circ}$ while measurement phase comparison's is larger than $2.5^{\circ}$, It can be used for electromagnetic signal monitoring and military direction detection.

BLR Density Variations of the Seyfert 1 Galaxies NGC 4151 and NGC 5548 (Seyfert 1 은하 NGC 4151, NGC 5548의 BLR 밀도 변화)

  • Son, Dong-Hoon;Hyung, Siek
    • Journal of the Korean earth science society
    • /
    • v.25 no.6
    • /
    • pp.495-501
    • /
    • 2004
  • Using numerous ground-based or space-based telescopes by many astronomers, AGN spectroscopic monitoring campaigns have been carried out over many years to study the variability of continua and emission lines. We investigate the SWP IUE spectra of a large aperture configuration for the Seyfert 1 galaxies NGC 4151 and NGC 5548. We estimate the BLR electron number densities and their variation from the line ratios of C III] 1909 to Si III] 1892. With the ratios of C IV 1550 to C III] 1909 which give us the information on the ionization parameter of BLR, we try to find the physical conditions of the BLR and activities of he super massive black hole surroundings. The BLR density variations scale as 4 and 8 for NGC 4151 and NGC 5548, respectively. Based on the BLR size and C III] line profiles, we found both black hole masses as about $10^7$ $M_{\odot}$.