• Title/Summary/Keyword: waterproofing spray

Search Result 32, Processing Time 0.033 seconds

An Experimental Study on Fundamental Properties of a Sprayable Waterproofing Membrane (뿜칠 방수 멤브레인 시작품의 기초 물성평가)

  • Chang, Soo-Ho;Kang, Tae-Ho;Choi, Soon-Wook;Lee, Chulho;Hwang, Gwi-Sung;Choi, Myung-Sik
    • Tunnel and Underground Space
    • /
    • v.26 no.3
    • /
    • pp.220-234
    • /
    • 2016
  • Sprayable waterproofing membrane has been considered as a substitute for a sheet waterproofing membrane in a variety of underground excavation works. However, fundamental properties of sprayble waterproofing membrane have not been fully given yet. In this study, a new two-component sprayable waterproofing membrane prototype was developed. In addition, its physico-mechanical properties were measured and compared with those of two kinds of thin spray-on liners where constitutive materials and construction methods are very close to each other. From direct tensile tests, the sprayable waterproofing membrane with elongations at break between 250% and 300% showed much higher ductility than TSLs. However, the sprayable waterproofing membrane had a limitation as a support member since its bond strength and loading capacity was lower than those of TSLs. From three-dimensional X-ray CT images, the porosity of the sprayable waterproofing membrane was estimated to be 26.13%. However, most of pores which might have been generated during membrane curing were not observed to be interconnected but isolated.

A Study on Examination of Application in Waste Filled Land and Performance Evaluation as Waterproofing Material by the Spray Water-Soluble Rubber Asphalt (뿜칠형 수용성 고무화 아스팔트 차수재의 성능평가 및 폐기물 매립지 적용성 검토에 관한 연구)

  • 오상근;김형무;정문정;최은수
    • Journal of the Korea Institute of Building Construction
    • /
    • v.1 no.2
    • /
    • pp.165-173
    • /
    • 2001
  • This study examinated the application in construction field and the development of waterproofing material system by the spray water-soluble rubber asphalt to solve the problems of synthetic polymer sheet and gio membrane(A mat sheet of Bentonite) that had been used domestic waterproofing material in advance. As the result of study, characters of study water-soluble rudder asphalt are the follows: 1) The amount of water absorption was '0.06'g and the seepage quality was '0'g in result. 2) The tensile strength was about 30.7kgf/$\textrm{cm}^2 and the elongation was about 72.4% in result. 3) After reliance of temperature test had been ended, the tensile strength was about 72.4kgf/$\textrm{cm}^2 in low temperature and about 30.7kgf/$\textrm{cm}^2 in normal temperature. 4) After acid and alkaline treatment had been ended, the tensile strength was about 19.7kgf/$\textrm{cm}^2$ and about 21.9kgf/$\textrm{cm}^2 in result. 5) After chlorine ion treatment had been ended, the tensile strength was 28.5kgf/$\textrm{cm}^2$ and the elongation was 250% in result. 6) The impact performance was subsided at 1.5m height. 7) After promotion weathering had been ended, the tensile and elongation was about 26.0kgf/$\textrm{cm}^2, 214% in result. So, this study can propose the spray water-soluble rubber asphalt to satisfy the and durability of waste filled land.

  • PDF

An Experimental Study on the Permeability Evaluation of Metal Spray System by Metal Spray Coating Surface Treatment (콘크리트 표면처리방법에 따른 금속용사 피막의 투수성 평가에 관한 실험적 연구)

  • Park, Jin-Ho;Jang, Hyun-O;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.50-51
    • /
    • 2016
  • Ozone is a strong oxidizing materials in the advanced water treatment facilities. However, due to such a strong oxidation, Ozone eroded waterproofing/corrosion on the concrete surface and caused performance degradation. Therefore, in this study, permeability experiment of metal spraying system by concrete surface treatment was conducted.

  • PDF

A Study on the Field Application Analysis for High Adhesive Spray Type of Degenerated and Rubberized Asphalt Membrane Material (스프레이식 고점착 변성 고무 아스팔트 도막 방수재의 현장 적용성 평가에 관한 실험적 연구)

  • Oh, Sang-Keun;Kwak, Kyu-Sung;Choi, Sung-Min;Song, Je-Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.6 no.4 s.22
    • /
    • pp.85-92
    • /
    • 2006
  • Urethane, epoxy, acrylic have common property to adhere on the concrete dried surface in the waterproofing materials at present. In the wet condition, however, the materials such as urethane, epoxy, acrylic need a long hardening time and it become a reason of water leakage as the materials breaking down. it is one of the problem to adhere to the substrate. Therefore, in this thesis, I focused to assure the structural safety and durability and quality for waterproofing and safe of construction cost by cut down the cost of labor and reduce the term of works as searching the application of field condition for high adhesive spray type of degenerated and rubberized asphalt membrane material.

Analysis of Water Penetration through Pores in Spray-applied Waterproofing Membrane Using X-ray CT Images (X-ray CT를 이용한 분무식 방수 멤브레인의 공극 내 물 침투 분석)

  • Choi, Soon-Wook;Kang, Tae-Ho;Chang, Soo-Ho;Lee, Chulho;Choi, Myung-Sik;Kim, Kwang Yeom
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.4
    • /
    • pp.211-219
    • /
    • 2017
  • The spray-applied waterproofing membrane is installed on shotcrete or concrete surface to make impermeable layer with 3-5 mm thick for the purpose of waterproofing. This study aims to determine the internal structure of a spray-applied waterproofing membrane including pores by using X-ray CT technique. Before obtaining X-ray images of the membrane specimens, a waterproof performance test was performed on the membrane specimens with a water pressure of 500 kPa for 28 days. Results show that the movement of moisture is made through micropores. This is based on the fact that the large pores inside the membrane are not saturated and the degrees of saturation of the micropores are high. X-ray image is effective for determining the pore size distribution and whether the membrane with pores contains the water However, it is necessary to pay attention to the determination of water content, since water content may vary depending on the threshold value of X-ray image analysis applied to calculate the water content.

A study on the Reduction of Scattering of Polyurea Coating for Waterproofing and Anti-Corrosion by Installing Air Jet Nozzle (에어분사구 설치에 따른 폴리우레아 도막 방수·방식재의 비산 발생 저감에 관한 연구)

  • Kim, Sun-Do;Park, Wan-Goo;Park, Jin-Sang;Cho, Il-Kyu;Kim, Byoung-Il;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.236-237
    • /
    • 2017
  • This study discusses the development of waterproofing layer jet-spray nozzle that forms a three-dimensional air cell. This nozzle has an air flow generation mechanism in the air groove of the attachment cell part located at the end of the injection nozzle. Since the air grooves also function as an air curtain, the airborne particles generated when the waterproof material is sprayed is effectively blocked. In the past, spraying of the waterproof material through the high pressure was possible, but this technology allows stable injection due to the static agitation method, and various problems caused by particle generation has been (damages to neighboring areas, economic loss, etc.) minimized.

  • PDF

Chemically Resistant Characteristic Analysis of the Liquid-Applied Membrane Waterproofing Materials of Rapid Hardening Spray Type Applied on the Concrete Structure (콘크리트 구조물에 적용되는 초속경 분사시공 도막 방수재료의 내화학 특성 분석 -폴리우레아, 폴리우레탄·우레아, 폴리우레탄 수지계 방수재료를 중심으로-)

  • Kim, Yun-Ho;Choi, Eun-Kyu;Park, Jin-Sang;Kim, Su-Ryun;Song, Je-Young;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.168-169
    • /
    • 2013
  • In this study, the chemical resistance of polyurea resin waterproofing and anti-corrosion materials that is applied to the social infrastructure was analyzed. The result in this study will be utilizing as a basic data for establishing the quality standards which are able to judge the chemically resistant characteristic of polyurea resin waterproofing and anti-corrosion materials.

  • PDF

An Experimental Study on the Permeability Evaluation of Metal Spray System by Concrete Surface Treatment (콘크리트 표면처리방법에 따른 금속용사 피막의 투수성 평가에 관한 실험적 연구)

  • Park, Jin-Ho;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.34-35
    • /
    • 2015
  • Recently, introduction of Advanced water treatment facilities has been increasing due to serious domestic water pollution. Ozone is a strong oxidizing materials in the advanced water treatment facilities. However, due to such a strong oxidation, Ozone eroded waterproofing/corrosion on the concrete surface and caused performance degradation. Therefore, in this study, permeability experiment of metal spraying system by concrete surface treatment was conducted.

  • PDF

Interfacial properties of composite shotcrete containing sprayed waterproofing membrane

  • Park, Byungkwan;Lee, Chulho;Choi, Soon-Wook;Kang, Tae-Ho;Kim, Jintae;Choi, Myung-Sik;Jeon, Seokwon;Chang, Soo-Ho
    • Geomechanics and Engineering
    • /
    • v.16 no.4
    • /
    • pp.385-397
    • /
    • 2018
  • This study evaluates the interfacial properties of composite specimens consisting of shotcrete and sprayed waterproofing membrane. Two different membrane prototypes were first produced and tested for their waterproofing ability. Then composite specimens were prepared and their interfacial properties assessed in direct shear and uniaxial compression tests. The direct shear test showed the peak shear strength and shear stiffness of the composites' interface decreased as the membrane layer became thicker. The shear stiffness, a key input parameter for numerical analysis, was estimated to be 0.32-1.74 GPa/m. Shear stress transfer at the interface between the shotcrete and membrane clearly emerged when measuring peak shear strengths (1-3 MPa) under given normal stress conditions of 0.3-1.5 MPa. The failure mechanism was predominantly shear failure at the interface in most composite specimens, and shear failure in the membranes. The uniaxial compression test yielded normal stiffness values for the composite specimens of 5-24 GPa/m. The composite specimens appeared to fail by the compressive force forming transverse tension cracks, mainly around the shotcrete surface perpendicular to the membrane layer. Even though the composite specimens had strength and stiffness values sufficient for shear stress transfer at the interfaces of the two shotcrete layers and the membrane, the sprayed waterproofing membrane should be as thin as possible whilst ensuring waterproofing so as to obtain higher strength and stiffness at the interface.

Evaluation of Bisphenol A-Epichlorohydrin Exposure Workers in Apartment Building Construction: Pilot Study (아파트 건축 작업장에서 사용되는 에피클로로하이드린-비스페놀A의 노출 평가: 파일럿 연구)

  • Shin, Wonho;Moon, Chan-Seok
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.4
    • /
    • pp.396-403
    • /
    • 2016
  • Objectives: The study is to evaluate biological monitoring and risk assessment for epichlorohydrin-bisphenol A resin exposed from waterproofing or finishing work in the apartment building construction. Methods: Subjected workers were working on spray-painting and waterproofing work for 8 hours per day every 20 days. The urine samples were collected at the end of 20 days working period. For urinary bisphenol A as metabolite from epichlorohydrin-bisphenol A exposure, urine samples were analyzed with liquid chromatography mass-mass spectrometry(HPLC-MS/MS). Results: Geometric means of urinary bisphenol A(BPA) with no hydrolysis and with enzymic hydrolysis(BPA-EH) in the workers were $1.10{\mu}g/L$ and $2.90{\mu}g/L$. BPA-EH was 4 times higher than that of control group. The factors for working period and ages did not affect the variation of BPA and BPA-EH. The levels for BPA and BPA-EH were not higher than 95th percentile for exposure on human-life environment. Conclusions: The BPA and BPA-EH were therefore effective biological markers for epichlorohydrin-bisphenol A exposure workers, but not seem to hazardous exposure level. Waterproofing work in construction workshop is required to measuring work environment and health care management for the workers.