• Title/Summary/Keyword: water vapor transport

Search Result 84, Processing Time 0.032 seconds

Subjective Evaluation of Wear Comfort and Related Physical Variables under Warm and Humid Condition (고온 다습한 환경에서의 주관적 착용 쾌적감과 관련 물성 변인)

  • Kim, Jeong-Hwa;Hong, Gyeong-Hui;Jo, Seung-Sik
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.21 no.6
    • /
    • pp.1021-1030
    • /
    • 1997
  • Physical variables related to the subjective evaluation of wear comfort were explored. Experimental fabrics was those used in the previous paper where subjective sensations of women's thin shirts were reported. Fabrics include 100% cotton (unfinished), 100% cotton (water repellent finished), cotton/polyester 35/65 (unfinished), cotton/polyester 35/65 (peach skin finished), 100% polyester fabric(plain), 100% polyester crepe. Among various physical properties of the experimental fabrics, heat 8E moisture transport properties and surface properties were chosen as important variables based on the regression coefficient. Especially, humidity at the microclimate in dynamic mode was highly correlated to the subjective evaluation and appeared to be a sensitive physical predictor, compared to dry thermal transmission rate or water vapor transmission rate. Surface characteristic parameters, however, did not show consistant trend in the prediction of the human's subjective sensation. Interaction between surface properties and humidity measurement was also observed.

  • PDF

Fundamental study on performance characteristics of a micro heat pipe with triangular cross section (삼각단면 극소히트파이프의 작동특성에 관한 기초 연구)

  • 문석환;김종오;김철주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.2
    • /
    • pp.176-184
    • /
    • 1999
  • Numerical and experimental studies were performed to examine the characteristics of heat and mass transfer processes for a Micro Heat Pipe(MHP) with a triangular cross-section. Solutions on mass flow rate, pressure variation, and radius of meniscus were obtained using the mathematical model developed by Faghri and Khrustalev. To obtain an increase in capillary limitation, a triangular tube with curved walls was designed and fabricated. The measurement by microscope showed that the radius at corners of the tube was ranging between 0.03-0.05mm. Performance test for MHPs using the triangular tube with curved walls proved a substantial increasement in heat transport limitation, with 4.5W and 2.0W in case of using water and ethanol as a working fluid, respectively. In the previous study by Faghri a limitation of 0.5W was reported for a water MHP with a regular triangular tube.

  • PDF

A Simple Condensation Model on the Vapor Jets in Subcooled Water (과냉각수로 방출되는 증기제트의 응축모델)

  • Kim, Hwan-Yeol;Ha, Kwang-Soon;Bae, Yoon-Yeong;Park, Jong-Kyun;Choi, Sang-Min
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.240-245
    • /
    • 2001
  • Phenomena of direct contact condensation (DCC) heat transfer between steam and water are characterized by the transport of heat and mass through a moving steam/water interface. Application of the phenomena of DCC heat transfer to the engineering industries provides some advantageous features in the viewpoint of enhanced heat transfer. This study proposes a simple condensation model on the steam jets discharging into subcooled water from a single horizontal pipe for the prediction of the steam jet shapes. The analysis model was derived from the mass, momentum and energy equations as well as a thermal balance equation with condensing characteristics at the steam/water interface for the axi-symmetric coordinates. The extremely large heat transfer rate at the steam/water interface was reflected in the effective thermal conductivity estimated from the previous experimental results. The analysis results were compared with the experimental ones. The analysis model predicted that the steam jet shape (i. e. radius and length) was increasing as the steam mass flux and the pool temperature were increasing, which was similar in trend to that observed in the experiment.

  • PDF

MTSAT Satellite Image Features on the Sever Storm Events in Yeongdong Region (영동지역 악기상 사례에 대한 MTSAT 위성 영상의 특징)

  • Kim, In-Hye;Kwon, Tae-Yong;Kim, Deok-Rae
    • Atmosphere
    • /
    • v.22 no.1
    • /
    • pp.29-45
    • /
    • 2012
  • An unusual autumn storm developed rapidly in the western part of the East sea on the early morning of 23 October 2006. This storm produced a record-breaking heavy rain and strong wind in the northern and middle part of the Yeong-dong region; 24-h rainfall of 304 mm over Gangneung and wind speed exceeding 63.7 m $s^{-1}$ over Sokcho. In this study, MTSAT-1R (Multi-fuctional Transport Satellite) water vapor and infrared channel imagery are examined to find out some features which are dynamically associated with the development of the storm. These features may be the precursor signals of the rapidly developing storm and can be employed for very short range forecast and nowcasting of severe storm. The satellite features are summarized: 1) MTSAT-1R Water Vapor imagery exhibited that distinct dark region develops over the Yellow sea at about 12 hours before the occurrence of maximum rainfall about 1100 KST on 23 October 2006. After then, it changes gradually into dry intrusion. This dark region in the water vapor image is closely related with the positive anomaly in 500 hPa Potential Vorticity field. 2) In the Infrared imagery, low stratus (brightness temperature: $0{\sim}5^{\circ}C$) develops from near Bo-Hai bay and Shanfung peninsula and then dissipates partially on the western coast of Korean peninsula. These features are found at 10~12 hours before the maximum rainfall occurrence, which are associated with the cold and warm advection in the lower troposphere. 3) The IR imagery reveals that two convective cloud cells (brightness temperature below $-50^{\circ}C$) merge each other and after merging it grows up rapidly over the western part of East sea at about 5 hours before the maximum rainfall occurrence. These features remind that there must be the upward flow in the upper troposphere and the low-layer convergence over the same region of East sea. The time of maximum growth of the convective cloud agrees well with the time of the maximum rainfall.

Analysis of Flow through High Pressure Bypass Valve in Power Plant (발전소용 고압 바이패스 밸브 내부 유동해석)

  • Cho, An-Tae;Kim, Kwang-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.6
    • /
    • pp.17-23
    • /
    • 2007
  • In the present work, flow analysis has been performed in the steam turbine bypass control valve (single-path type) for two different cases i.e., case with steam only and case with both steam and water. The numerical analysis is performed by solving three-dimensional Reynolds-averaged Navier-Stokes (RANS) equations. The shear stress transport (SST) model and $k-{\varepsilon}$ model are used to each different case as turbulence closure. Symmetry condition is applied at the mid plane of the valve while adiabatic condition is used at the outer wall of the cage. Grid independency test is performed to find the optimal number of grid points. The pressure and temperature distributions on the outer wall of the cage are analyzed. The mass flow rate at maximum plug opening condition is compared with the designed mass flow rate. The numerical analysis of multiphase mixing flow(liquid and vapor) is also performed to inspect liquid-vapor volume fraction of bypass valve. The result of volume fraction is useful to estimate both the safety and confidence of valve design.

Cavitating Flow Analysis of Multistage Centrifugal Pump (다단 원심펌프의 공동현상 유동해석)

  • Rakibuzzaman, Rakibuzzaman;Suh, Sang-Ho;Kim, Hyoung-Ho;Cho, Min-Tae;Shin, Byeong-Rog
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.1
    • /
    • pp.65-71
    • /
    • 2015
  • The purpose of this study is to investigate cavitating flow of the multistage centrifugal pump. Cavitation is observed in the impeller leading edge and trailing edge of the suction area. Head coefficients are measured under different flow operating conditions. The Rayleigh-Plesset cavitation model is adapted to predict the occurrence of cavitation in the pump. The two-phase gas-liquid homogeneous CFD method is used to analyze the centrifugal pump performances with two equation transport turbulence model. The simulations are carried out with three different flow coefficients such as 0.103, 0.128 and 0.154. The occurrence of cavitation described according to water vapor volume fraction. The head versus NPSH (Net Positive Suction Head) also measured using different flow coefficients. Development of cavitation in the centrifugal pump impellerI is discussed. It is showed that the simulation represents the head drop about 3%.

A Study on the Miniature Loop Heat Pipe with Non-inverted Meniscus type Capillary Structure (Non-inverted Meniscus식 모세관 구조물을 이용한 소형 루프히트파이프에 관한 실험적 연구)

  • Chung, Won-Bok;Park, Soo-Yong;Doctarau, Viachaslau-V.
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2142-2147
    • /
    • 2007
  • Experimental study was conducted to evaluate the performance of a miniature loop heat pipe (MLHP) with non-inverted meniscus type capillary structure. All parts of MLHP in this study were made of copper including the capillary structure and the distilled water was used as a working fluid of MLHP. The outer diameter of evaporator was 9 mm and its length was 119 mm. The effective pore size of the capillary structure was 30 micron and its porosity was 60%. The vapor transport line, the liquid transport line and the condenser were consisted of single 4.0 mm copper tube. The distance between the evaporator and the condenser region was 200 mm and the length of the loop was 969 mm. This MLHP was operated successfully at any orientation but the gravity highly influenced the thermal performance of the MLHP. The maximum thermal load was 130 watts at the bottom heat mode and the 20 watts at the top heat mode.

  • PDF

New MOD solution for the preparation of high $J_c$ REBCO superconducting films (고특성 REBCO 초전도 박막 제조를 위한 새로운 MOD 전구 용액 제조)

  • Kim, Byeong-Joo;Hong, Gye-Won;Lee, Hee-Gyoun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2001-2003
    • /
    • 2005
  • Various organic acid were used in order to prepare new metalorganic deposition solution for high quality $REBa_2Cu_3O_{7-{\delta}}$ (RE=Y, Eu, Gd) films. Prepared fluorine free MO precursor solution was coated on single crystal (001) $LaAlO_3$ (LAO) by dip coating method. Processing parameters such as oxygen partial pressure, water vapor, ramping rate and pyrolysis temperature etc havebeen controlled in order to make high $J_c$ films with a good epitaxial relationship with substrate. 0.5 micron-thick film was obtained by single coating and no crack appeared after calcination. Oxygen partial pressure was varied in the range of $100{\sim}1,000 ppm$ and conversion heat treatment was carried out at the temperature of $725{\sim}765^{\circ}C$. A critical transition temperature $(T_{c0})$ of 90K and a critical transport current density $(J_c)$ of $>0.5MA/cm^2$ (77K and self-field) were demonstrated for the YBCO film on (001) oriented LAO substrates with a thickness of 0.5 micron. $I_c$ was determined by utilizing a transport measurement. SEM and XRD investigations confirmed that films were grown epitaxially onto the LAO single crystal substrate. It is thought that fluorine free new MOD solutionis promising for high quality REBCO films.

  • PDF

A Study of Sports Socks Varying Knitted Fabrics on Hygienic and stability Properties (각종 편성소재에 따른 스포츠양말의 위생성과 형태안정성에 관한 연구)

  • 이명자;김칠순
    • The Research Journal of the Costume Culture
    • /
    • v.7 no.5
    • /
    • pp.165-176
    • /
    • 1999
  • The purpose of this study was to evaluate the effect of various knitted fabrics of sports socks on their properties of hygiene and stability. Seventeen men\`s sports socks to represent five groups with different fiber content, knit structure, yarn fineness, and finishing were used. Properties of hygiene and stability of socks were determined. The results were as follows ; 1. Evaluation of Water, vapor and heat transport properties in socks with varing fiber content showed that cotton 100% socks had the highest drop absorbency, wickability, water absorbency and water retention. Polypropylene 100% socks had an excellent wickability and moisture permeability. Acrylic blend socks had the highest thermal resistance. 2. The greatest knit stretch and knit growth of socks having lower power were found to be with cotton 100% socks had the lowest stretch. Acrylic blend socks had a excellent stretch but low fabric growth, which could give a good fir sensation during wear. 3. The commerical antimicrobial finished socks showed excellent durability after repeated cycles of laundering. 4. Length and width shrinkages were found in all laundered samples during initial cycles due to rearrangement by mechanical relaxation. Shrinkages showed no further changes and reached equilibriums after 5 cycles. Cotton 100% or cotton blend socks showed lower dimensional stability than other socks during fabric care.

  • PDF

THE USE OF QUICKS CAT WIND TO ESTIMATE THE VERTICAL VELOCITY IN TYPHOON AND SNOWSTORM

  • Heol Ki-young;Ha Kyung-Ja;Lee Dong-Kyu;Jeong Jin-Yong
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.54-57
    • /
    • 2005
  • This study examines moisture supplement from the warm ocean in snowfalls of two cases and heavy rainfall of Typhoon case. The QuickSCAT wind is used to evaluate the convergence of moisture fluxes in the storms from the sea in estimation of the amount of heavy snowstorm and rainfall. The results show that enough water vapor transport from ocean to atmosphere induced the severe storms, because strong QuickSCAT -derived vertical velocity nearly concurred with heavy snowfall and rainfall. In the present study, we attempted to show that QuickSCAT wind can be used to forecast the severe weather events, such as heavy snowfall and rainfalls.

  • PDF