• Title/Summary/Keyword: water surface velocity meter

Search Result 31, Processing Time 0.023 seconds

Physical Oceanographic Characteristics in Hupo Coastal area during Summer and Autumn, 2007 (2007년 하계 및 추계 경상북도 후포연악역 물리적 해황특성)

  • Hwang, Jae-Dong;Lee, Yong-Hwa;Shim, Jeong-Min;Young, Seok-Hyun;Jin, Hyun-Gook;Kim, Young-Suk;Kwon, Kee-Young;Yoon, Sang-Chol
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.41 no.6
    • /
    • pp.505-510
    • /
    • 2008
  • To understand the oceanographic characteristics of Hupo coastal waters as regards the East Korean Warm Current and the North Korean Cold Current, current direction and velocity were investigated by deploying a current meter in Hupo coastal waters during the summer and fall of 2007. Wind data were obtained from the homepage of the Korea Meteorological Administration. Water temperature was measured using a temperature meter attached to the current meter and a mini log. During summer, a south wind prevailed, while during the fall the wind blew from the north. Cold surface waters occurred on a large scale in summer, while in the fall, warm bottom water occurred frequently. After mid-November, when the surface water was cooler than $15^{\circ}C$, there was no difference in water temperature between the surface and bottom layers.

On the Cold Water Mass Around the Southeast Coast of Korean Peninsula

  • An, Hui Soo
    • 한국해양학회지
    • /
    • v.9 no.2
    • /
    • pp.10-18
    • /
    • 1974
  • The cold water mass around the southeast coast of the Korean Peninsula is analyzed by using CSK data from 1966 through 1970. It is shown that this water mass flows down from the region offshore of Jukbyun to the area of Youngil Bay along the 100meter contour line of bottom topography. In ordinary summer conditions when the current velocity in the Korea Strait is usually above about 50cm/sec and the wind direction is southwest, the cold water ascends to the surface and makes the surface temperature gradient large, unless disturbed by a tropical cyclon. The bottom water of the Korea Strait is formed by the stratification after the Tsushima intermediate water and the Japan Sea intermediate water have been mixed. In winter the Tsushima intermediate water with high salinity sinks rapidly around the inlet of the Japan Sea and prevents the Japan Sea intemediate water from entering the Korea Strait.

  • PDF

Accuracy evaluation of microwave water surface current meter for measurement angles in middle flow condition (전자파표면유속계의 측정 각도에 따른 평수기 유속 측정 정확도 분석)

  • Son, Geunsoo;Kim, Dongsu;Kim, Kyungdong;Kim, Jongmin
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.1
    • /
    • pp.15-27
    • /
    • 2020
  • Streamflow discharge as a fundamental riverine quantity plays a crucial role in water resources management, thereby requiring accurate in-situ measurement. Recent advances in instrumentations for the streamflow discharge measurement has complemented or substituted classical devices and methods. Among various potential methods, surface current meter using microwave has increasingly begun to be applied not only for flood but also normal flow discharge measurement, remotely and safely enabling practitioners to measure flow velocity postulating indirect contact. With minimized field preparedness, this method facilitated and eased flood discharge measurement in the difficult in-situ conditions such as extreme flood in active ways emitting 24.125 GHz microwave without relying on natural lights. In South Korea, a rectangular shaped instrument named with Microwave Water Surface Current Meter (MWSCM) has been developed and commercially released around 2010, in which domestic agencies charging on streamflow observation shed lights on this approach regarding it as a potential substitute. Considering this brand-new device highlighted for efficient flow measurement, however, there has been few noticeable efforts in systematic and comprehensive evaluation of its performance in various measurement and riverine conditions that lead to lack in imminent and widely spreading usages in practices. This study attempted to evaluate the MWSCM in terms of instrumen's monitoring configuration particularly regarding tilt and yaw angle. In the middle of pointing the measurement spot in a given cross-section, the observation campaign inevitably poses accuracy issues related with different tilt and yaw angles of the instrument, which can be a conventionally major source of errors for this type of instrument. Focusing on the perspective of instrument configuration, the instrument was tested in a controlled outdoor river channel located in KICT River Experiment Center with a fixed flow condition of around 1 m/s flow speed with steady flow supply, 6 m of channel width, and less than 1 m of shallow flow depth, where the detailed velocity measurements with SonTek micro-ADV was used for validation. As results, less than 15 degree in tilting angle generated much higher deviation, and higher yawing angle proportionally increased coefficient of variance. Yaw angles affected accuracy in terms of measurement area.

Development of High-performance Microwave Water Surface Current Meter for General Use to Extend the Applicable Velocity Range of Microwave Water Surface Current Meter on River Discharge Measurements (전자파표면유속계를 이용한 하천유량측정의 적용범위 확장을 위한 고성능 범용 전자파표면유속계의 개발)

  • Kim, Youngsung;Won, Nam-Il;Noh, Joonwoo;Park, Won-Cheol
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.8
    • /
    • pp.613-623
    • /
    • 2015
  • To overcome the difficulties of discharge measurements during flood season, MWSCM(micowave water surface current meter) which measures river surface velocities without contacting water has been applied in field work since its development. The existing version of MWSCM is for floods so that its applicability is low due to the short periods of floods. Therefore the renovative redesign of MWSCM to increase the applicability was conducted so that it can be applied to the discharge measurements during normal flows as well as flood ones by extending the measurable range of velocity. A newly developed high-performance MWSCM for general use can measure the velocity range of 0.03-20.0 m/s from flood flows to normal flows, whereas MWSCM for floods can measure the velocity range of 0.5-10.0 m/s. The improvement of antenna isolation between transmitter and receiver to block the inflow of transmitted singals to receiver and the improvement of phase noise of oscillator are necessary for detecting low velocity with MWSCM technology. Separate type antenna of transmitting and receiving signals is developed for isolation enhancement and phase locked loop synthesizer as an oscillator is applied to high-performance MWSCM for general use. Microwave frequency of 24 GHz is applied to the new MWSCM rather than 10 GHz to make the new MWSCM small and light for convenient use of it at fields. Improvement requests on MWSCM for floods-stable velocity measurement, self test, low power consumtion, and waterproof and dampproof-from the users of it has been reflected on the development of the new version of MWSCM.

Experimental Comparison and Analysis of Measurement Results Using Various Flow Meters (유량측정 기기별 측정성과에 대한 실험적 비교분석)

  • Lee, Jae-Hyug;Lee, Suk-Ho;Jung, Sung-Won;Kim, Tae-Woong
    • Journal of Wetlands Research
    • /
    • v.12 no.1
    • /
    • pp.95-103
    • /
    • 2010
  • Discharge data examine the process of hydrologic cycle and used significantly in water resource planning and irrigation and flood control planning. However, it needs lots of time and money to get the discharge data. So discharge rating curve is usually used in converting discharge data. Therefore reliability of discharge rating curve absolutely depends on quality of discharge data. Many engineers who study hydrologic engineering make high quality discharge data to develop reliable discharge rating curve. And they carry out research on standard and method of discharge measurement, and equipment improvement. Now various flow meters are utilized to make discharge data in Korea. However, accuracy of equipment and experimental research data from measurement are not enough. In this paper, constant discharge flowed through standard concrete channel, and the velocity is measured using various flow meters. Also Discharge is calculated by measured data to compare and analyze. The equipment for the experiment is Price AA(USGS Type AA Current meter), flow meter, ADC, C2 small current meter, flow tracker, Electromagnetic current meter. The discharge got form various flow meters which are widely used for discharge measurement. The various depths of water were examined and compared such as 0.30 m, 0.35 m, 0.40 m, 0.45 m, 0.50 m, 0.55 m. The experiment progresses a round-measurement on 6-case. Wading measurement(one point method : the 60 % height in surface of the water) was applied to improve creditability and accuracy among measurement methods. USGS Type AA current Meter, Flow Meter, ADC, C2 Small Current meter got the certificate of quality guaranteed. So the results of experiment were used to compare discharge. The Results showed the difference based on USGS Type AA current Meter at average discharge and velocity. Electromagnetic current meter made differences over $\pm$ 10 % and Flow Meter made differences under $\pm$ 10 %. Also ADC, Flow Meter, C2 Small Current meter made differences under $\pm$ 5 %.

Comparison of the Accuracy of Velocity Measurement Using LSPIV (LSPIV를 이용한 유속측정 정확도 비교)

  • Hwang Eui-Ho;Yang Jae-Rheen;Koh Deuk-Koo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1512-1517
    • /
    • 2005
  • Soil particles from rainfall flow into reservoir and give lots of influence in water quality because the Even though techniques related with computer and communications are growing rapidly, it is true that efforts for hydrological survey and the management of its results have not been made enough to make use of the state-of-the-art technologies. Among the water-related techniques, measurement of river discharge is the most important one because these data are basic to almost every field of the hydrological science. In this research, a large-scale particle image velocimetry (LSPIV) unit has been designed and constructed to measure river discharge effectively In field conditions. Measured data using this unit is compared with the results recorded by the microwave water surface current meter (MWSCM) at the same location. The purpose of this research is to propagate the feasibility of using the MWSCM for river discharge velocimetry.

  • PDF

Real-time Discharge Measurement of the River Using Fixed-type Surface Image Velocimetry (고정식 표면영상유속계 (FSIV)를 이용한 실시간 하천 유량 산정)

  • Kim, Seo-Jun;Yu, Kwon-Kyu;Yoon, Byung-Man
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.5
    • /
    • pp.377-388
    • /
    • 2011
  • Surface Image Velocimetry (SIV) is a recently-developed discharge measurement instrument. It uses image processing techniques to measure the water surface velocity and estimate water discharge with given cross section. The present study aims to implement a FSIV (Fixed-type Surface Image Velocimetry) at Soojeon Bridge in the Dalcheon. The hardware system consists of two digital cameras, a computer, and a pressure-type water stage gauge. The images taken with the hardware system are sent to a server computer via a wireless internet, and analyzed with a image processing software (SIV software). The estimated discharges were compared with the observed discharges through Goesan dam spillway and index velocity method using ADVM. The computed results showed a good agreement with the observed one, except for the night time. The results compared with discharges through Goesan dam spillway reached around 5~10% in the case of discharge over 30 m3/s, and the results compared with discharges through index velocity method using ADVM reached around 5% in the case of discharge over 200 $m^3/s$. Considering the low cost of the system and the visual inspection of the site situation with the images, the SIV would be fairly good way to measure water discharge in real time.

Design of FMCW radar waveform for flow measurement (유량 측정을 위한 FMCW 레이다 파형 설계)

  • Lee, Changki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.1
    • /
    • pp.83-90
    • /
    • 2020
  • A commercial flow measurement radar sensor estimates a quantity of flowed water using surface flow rate. In this way, the amount of water flowing per unit time cannot be measured accurately because of using an estimation result and it can't response environmental changes. For more accurate flow measurements we need width of waterway, water level and distance that water moved per unit time. Commonly two sensors are used to measure water level and flow rate. In this paper, we propose a method to simultaneously measure the water level and surface flow velocity using a single FMCW radar sensor and design the transmission waveform. In order to verify the waveform design, received signal is modelled based on transmission waveform. In addition, we consider phenomenons and problems that may occur in signal processing.

Accuracy Analysis for Velocity Measurement of Microwave Water Surface Current Meter Considering Yaw Angle and Illuminated Area (편각과 측정영역을 고려한 전자파표면유속계의 유속 측정 정확도 분석)

  • Son, Geunsoo;Kim, Dongsu;Kim, Kyungdong;Kim, Seojun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.100-100
    • /
    • 2016
  • 전자파표면유속계는 대표적인 비접촉식 계측기기로 최근 유량조사를 위해 활발하게 활용되고 있다. 국내에서 사용되고 있는 전자파표면유속계는 평수기 저유속에서도 측정이 가능하고 편각 측정이 가능하도록 개발되어 한 측정 지점에서 다 지점의 유속이 측정이 가능해 평수기 홍수기에 비교적 적은 인원으로 빠른 시간에 유량측정이 가능하다. 하지만 국내의 경우 전자파표면유속계가 과연 얼마만큼의 정확한 유속을 측정하는지에 대한 분석이 다소 부족한 실정으로 특히, 실제 하천에서 정확한 분석은 수행되지 않은 상태에서 유량 측정에 사용되고 있다. 전자파표면유속계를 실제 하천에서 사용할 경우 발생 할 수 있는 오차의 요인으로는 교량과 같이 높은 지점에서 측정을 수행할 경우 측정영역(Footprint or Illuminated area)에 따른 오차가 발생할 수 있는 가능성이 있고, 동일 측정 지점에 대해 수직각과 편각에 변화에 따른 유속 측정 오차가 발생할 수 있다. 이에 본 연구에서는 국내에서 개발된 Mutronics사의 전자파표면유속계(MWSCM; Microwave Water Surface Current Meter)에 레이저포인터를 부착하여 표면유속 약 0.5m/s ~ 1m/s의 자연 하천과 매우 유사한 실제 소하천 규모의 한국건설기술연구원 안동실험센터 직선하천에서 수직각(Tilt angle) 및 편각(Yaw angle)을 변화시켜가며 유속를 측정하였다. 그리고 측정된 결과를 활용하여 수직각과 편각의 변화에 따른 전자파표면유속계의 측정영역을 검토하였고, 동일한 측정 지점에 micro-ADV를 이용해 측정된 연직유속분포를 외삽하여 산정된 표면유속과 비교하여 전자파표면유속계의 측정 정확도를 분석하였다. 분석결과, 수직각(Tilt angle) 15도 이하에서는 유속 측정의 정확도가 떨어지는 것으로 나타났고, 편각(Yaw angle)이 커질수록 측정영역이 커지게 되어 변동 계수가 증가하는 것으로 나타났다. 그리고 전자파표면유속계의 측정 오차는 측정영역에 민감하게 반응하는 것으로 나타나 실제 전자파표면유속계를 이용한 유량측정 시 측정영역을 고려한 측정이 수행되어야 할 것으로 판단된다.

  • PDF

Estimation of Mean velocity conversion coefficient for measuring Microwave water surface current meter using Drone (드론을 이용한 전자파표면유속계 측정의 평균유속환산계수 산정)

  • Lee, Tae Hee;Kang, Jong Wan;Lee, Ki Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.16-16
    • /
    • 2021
  • 전자파표면유속계(Microwave Water Surface Current Meter)를 이용한 홍수기 유량측정은 교량과 같은 구조물을 이용하여 안전 및 측정위치의 흐름조건 등의 이유로 측정의 한계가 발생한다. 이런 문제점을 개선하기 위해 전자파표면유속계를 드론(Drone)과 결합하여 하천에서의 유량측정에 이용하였다. 전자파표면유속계는 비접촉식 유속측정 장비로 하천의 표면유속을 측정하고 유량산정을 위해 환산계수 0.85를 적용하여 평균유속을 산정하고 있다. 환산계수 0.85는 하천의 각 횡측선 수심-유속분포를 일반적인 분포로 가정하고 표면유속에 0.85를 곱하여 평균유속을 산정한다(Rantz, 1982). 그러나 하천의 측정위치 및 흐름특성에 따라 유속분포가 변화하기 때문에 국외 많은 연구에서 환산계수의 범위를 0.72에서 1.72까지 제시한 바 있다(Johnson and Cowen, 2017). 따라서 환산계수 0.85의 일률적인 적용은 부정확한 유량산정을 초래할 수 있어 측정위치에 적절한 환산계수 산정이 필요하다. 본 연구에서는 2020년 금강의 지류인 봉황천에 위치한 금산군(황풍교) 관측소에서 드론과 전자파표면유속계를 이용해 측정한 표면유속과 ADCP를 이용하여 동시 측정한 평균유속의 비교를 통해 환산계수를 산정하여 평균유속 산정의 정확도를 높이고자 하였다. 전자파표면유속계로 측정한 6개 성과 중 ADCP와 동시 측정한 4개의 성과를 분석하여 환산계수를 산정하였다. 측정성과별 측선수는 16~17개로 홍수터로 월류하여 비정상흐름이 발생한 측선은 제외하고 측선별 환산계수는 0.66에서 1.09의 범위로 나타났고, 성과별 환산계수의 평균치는 0.90에서 0.93 범위로 산정되었다. 환산계수가 일반적인 수치보다 높게 산정된 것은 측정위치 하류 약 600m에 위치한 콘크리트 고정보의 영향이 홍수 시 흐름의 수위-유속분포에 영향을 미쳐 높게 산정된 것으로 판단된다. 따라서 유량산정에 있어 환산계수는 4개 성과에서 산정된 환산계수의 평균치인 0.92를 적용하여 산정하였다.

  • PDF