• 제목/요약/키워드: water supply system

검색결과 1,483건 처리시간 0.033초

광역상수도용 펌프의 전양정 결정에 관한 연구 (A Study on the Total Head Decision of Pump for Regional Water Supply Facilities)

  • 김경엽;서상호;이정우;노형운;김상균
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.165-170
    • /
    • 2001
  • An extensive range of pumping facilities are employed in the regional water supply system in metropolitan areas, and optimization and the systematic combination of the Pump facilities have direct bearing on the stability and economy of the water supply system concerned. These systems must be able to guarantee stability, efficiency and offer high reliability. Preparation of metropolitan area regional water supply system construction project must include a basic plan which takes into account the suitability of pumping facilities to be used, the environment in which facilities will be installed, man-power requirements and basic operational and management policies. This paper contains over-all analysis of the management of metropolitan area regional water supply systems as like Jayang, Paldang 1st pump station. In the study, it aims to prepare counterplan which will be operated and managed the pump upon the operational conditions and to suggest the proposal for water facilities codes to decides total head of pump in Korea.

  • PDF

상하수도시설에 대한 전과정관리(LCM)시스템 구축방안 연구 (Establishment of Life Cycle Management(LCM) System for Water Supply and Sewerage Systems)

  • 박지형;황용우;김영운;박광호
    • 상하수도학회지
    • /
    • 제26권2호
    • /
    • pp.303-312
    • /
    • 2012
  • Water supply and sewerage systems are the large-scale urban infrastructure ejecting large amount of environmental load over the life-cycle. Therefore, it is important not only to optimize in the aspect of economical superiority and process efficiency but also to consider earth scale environmental impact. This study aimed to suggest the establishment of life cycle management(LCM) system as an integrated management solution in urban water supply and sewerage systems. As a result, the methodology for LCM system consisting of life cycle assessment(LCA), life cycle cost(LCC), life cycle $CO_{2}(LCCO_{2})$ and life cycle energy(LCE) was developed. Also, several case studies using the latest statistics data of water supply and sewerage systems were carried out to investigate the field applicability of LCM.

MIP에 의한 댐군연계운영 최적화모형 개발과 개발 모형에 의한 낙동강수계 용수공급능력 재평가 (Development of Optimal Reservoir System Operation Model for Water Supply by Applying MIP Technique and Reappraisal of Water Supply Capability of Nakdong River Basin)

  • 최영송;안경수;박명기
    • 한국수자원학회논문집
    • /
    • 제33권4호
    • /
    • pp.447-459
    • /
    • 2000
  • 수자원 개발이 인문 사회적 여건으로 날로 어려워짐에 따라 공급위주의 물 관리 정책이 한계에 달하고 이어 수요관리개념에 따른 적용 가능한 수자원관리 기법의 개발이 필요해지고 있다. 무효방류량을 최소화하여 한정된 물 자원 배분을 합리적으로 이룰 수 있는 실제 적용 가능한 수요관리기법은 수자원의 효율적 이용과 유역물관리 시스템의 방법론적 완성을 위해 반드시 필요하다. 본 연구는 기존의 물수지분석 기법을 댐 연계운영 모형과 조합하여 MIP 기법에 의해 이수목적 다목적댐 최적연계운영모형을 개발하고 낙동강 수계를 대상으로 모형의 적용성에 대한 검증을 실시하였으며 낙동강 수계의 용수공급능력을 재평가하였다. 이 결과를 계획 당시 자료 및 다른 모형에 의한 운영결과와 비교한 바 개발된 모형은 훌륭히 물 부족량 공급방식으로 수계의 물 공급을 보장할 수 있고 기존 모형등에 의한 방식보다 물배분과 관리에 효율적으로 활용 될 수 있음이 평가되었다.

  • PDF

NYC-Space Allocation Rule을 이용한 병렬저수지 연계운영 (Parallel reservoirs system operation using NYC-Space Allocation-Rule)

  • 박기범;이순탁
    • 한국환경과학회지
    • /
    • 제14권6호
    • /
    • pp.533-542
    • /
    • 2005
  • In this study, an optimization technique was developed from the application of Allocation Rule. Average Allocation coefficients of the Andong and Imha dam compare constant water supply condition with vary water supply condition that are above the contribute ratio $67\%\~50\%$ the Andong dam in Rule(A)-Rule(C). In the Refill Season, Andong dam water supply contribution is higher than Imha dam at the Control point water supply. In the Allocation analysis results, Rule(A) is calculated storage ratio because Andong dam contribute to Control point larger than Imha dam which Andong dam storage is larger than Imha dam storage. Rule(B) calculated sum of the storage and inflow ratio for Andong dam and Imha dam, as Andong dam contribution is higher than Imha dam. Rule(C) calculated that sum of storage, inflow and water supply is divided average storage ratio, as the best results of the Allocation coefficients and water supply capacity. The results of storage analysis is larger vary water supply condition than constant water supply condition and the results of water supply analysis is larger vary water supply condition than constant water supply condition. Water supply deficit is decrease $30\%$ for vary water supply condition.

농촌지역 간이상수도시설 개발 및 개선에 관한 연구 (A Study on the Development and Improvement of Simple Piped Water Supply System in Rural Area of Korea)

  • 정용;구자건;김명호;윤석우;김인숙
    • 농촌의학ㆍ지역보건
    • /
    • 제13권1호
    • /
    • pp.19-25
    • /
    • 1988
  • It is very important to supply safe drinking water for rural area not only a prevention of entric diseases but also a promotion of health life. It is estimated that 6,981,000 rural inhabitants were covered by the simple piped water supply system at the end of 1987 in Korea. The programme for improvement of water supply system in rural villages was initiated by the government since 1967. But most of these systems have been operated carelessly by the hands of villagers who have no proper knowledge and experience. Since most of water sources were located nearby farmland, there might be a possibility that the sources could be contaminated by pesticides and fertilizers. For this reason, it is recommended to take underground water as a water source rather than surface water such as a pond or streamwater in rural areas. However, the system is supplied from the surface water, its water quality can be improved by using of simple sand filter and simple chlorinator inexpensively. On the basis of an on-site study, conducted during 1986-87, in San-Buk Village, Keum-Sa-Myon, Yeju-Gun, Kyong-Gi-Do, the new simple piped water supply system was designed by the Institute for Environmental Research, Yonsei University, and constructed by the villagers themselves in September 1987. This simple system which is protected by metal fences consists of three main parts, pump house, vertical sand filter and water tank. The pumped water from underground flows into the upper part of the sand filter, through the sand, and out the water tank which is connected to the bottom of vertical filter. And the simple plastic-bottle chlorinator was installed in the water tank for chlorination. The water quality was remarkably improved after completion of construction. The total bacterial count was not detected from the tap water in households distributed by this simple piped water supply system. The construction cost of this system which was connected 34 households in San-Buk Village, was 4,851,000 won (approximately 6,020 U.S. dollars : 1$=805.8 won) in 1987,77% of expenses was supported by the Community Development Foundation in Korea. This case study for simple piped water supply projects will be applicable to other programme for improvement of water supply system in rural areas of Korea, and other developing countries.

  • PDF

간이상수도에서 물과 약품의 혼합방법 (Mixing Method of Water and Chemicals in a Small-Scale Water Supply System)

  • 유영현;기현;최종욱;김성초;김정수;김용선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3128-3133
    • /
    • 2007
  • The mixing method of water and chemicals is significant in a small-scale water supply system because drinking water should be supplied with a certain quantity of remaining chemicals maintained. In the present study, the concentration distribution and the mixing index were obtained from four models, which were to find out the optimal mixing method of water and chemicals. The two models brought the good mixing effects out of the four, one for providing chemicals from the center of water supply pipe and the other for setting up the semicircle block at the downstream of the chemicals-providing pipe. As a result, the mixing effect was found out to be increased due to the diffusion and the disturbance of flows. In conclusion, these results are expected to contribute to designing the optimal mixing system.

  • PDF

낙동강하류 유황을 고려한 안동댐의 효율적인 용수공급방안에 관한 연구 (A Study on the Effective Operating System for Water Supply of Andong Dam Considering the Flow of Nak-dong River)

  • 이제찬;장석환;이창해
    • 한국방재학회 논문집
    • /
    • 제8권6호
    • /
    • pp.129-136
    • /
    • 2008
  • 본 연구는 낙동강유역 안동댐을 대상으로 기존댐의 효율적 이용 및 증대방안을 연구하는데 목적이 있다. 본 연구에서는 낙동강하류를 대표하는 진동지점의 유황특성을 파악하고 안동댐 실측운영자료를 기준으로 HEC-5 모형을 이용하여 안동댐 용수공급 신뢰도를 평가하였으며, 비홍수기에 추가 용수공급량에 대하여 방안별 용수공급능력을 평가하였다. 연구결과, 낙동강 유량이 풍부한 홍수기에 댐하류 공급량을 안동댐에 저장했다가 비홍수기에 추가 공급가능량은 방안별로 $1.35m^3/s{\sim}2.12m^3/s$정도로 평가하였으며, 이를 바탕으로 현시점에서 여타 기존댐에 대해 댐건설 당시 적용된 농업용수 사용량을 재조사하여 최적의 필요량을 공급하고 비홍수기에 공급할 수 있는 방안 등의 효율적인 용수공급증대 방안에 대하여 발전적인 연구와 실효성있는 댐운영을 기대한다.

BYG형 급수기의 MINI PC 제어 시스템 (Mini PC control system for BYG type water supply units)

  • 박용규;강영모
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국내학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.1167-1171
    • /
    • 1993
  • A highly efficient hydropneumatic water supply system type BGY is designed and built in accordance with ISO standard. The technical features of BYG type pump unit can be summarized as follows: - reduce hydropneumatic tank capacity at the ratio of 1/10 - 1/30 compared with conventional method. - ISO standard pumps can be used. - the development of highly efficient water supply system type BYG is based on long-term experiences with the proven constant pressure water supply technique which minimize pressure fluctuation, rapid pilsation, etc. The text contains the operation principle of BYG type water supply system, introduction of closed cycle control process focused on Mini PC and experimental results of type BYG-IVS-90x45.

  • PDF

제로카본 그린홈 구현을 위한 하이브리드 열공급 시스템의 열성능 분석 (Thermal Performance Analysis of Hybrid heat Supply System for Zero Carbon Green Home)

  • 주홍진;이경호;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제32권6호
    • /
    • pp.53-59
    • /
    • 2012
  • This study was carried out to evaluate thermal performance of the renewable hybrid heat supply system with solar thermal system and wood pellet boiler for Zero Carbon Green home of apartment houses. The hybrid heat supply system was set up at Korea Institute Energy Research in 2011. The system was comprised of the wood pellet boiler unit with heat capacity designed as 20,000kcal/hr, a $0.15m^3$ hot water storage tank for space heating, a evacuated tubular solar collector $3.74m^2$ of aperture area at the $20^{\circ}$ install angle, a $0.3m^3$ hot water storage tank. Thermal performance tests for one-house of apartment house were carried out by hot water load and heating load in winter season through the hybrid heat supply system. As a result, hot water energy supplied by the hybrid heat supply system was 11kWh in a day. Solar thermal energy portion was 2.99kWh which is 27% of the total hot water energy supply. wood pellet boiler supply portion was 8.017kWh which is 73% of the total hot water energy supply.

농업용 저수지 용수공급 모의 시스템의 개발 (Development of agricultural reservoir water supply simulation system)

  • 전상민;강문성;송인홍;송정헌;박지훈;기우석
    • 농촌계획
    • /
    • 제20권2호
    • /
    • pp.103-114
    • /
    • 2014
  • The objective of this study was to develop agricultural reservoir water supply simulation system to assess water cycle of agricultural water district. Developed system was named as ARWS (Agricultural Reservoir Water supply simulation System). ARWS consists of platform and independent modules. In ARWS, reservoir inflow was calculated using Tank model, and agricultural water supply was calculated considering current farming period and mid-summer drainage. ARWS was applied to simulate water level of Gopung and Tapjung reservoir in 2011 - 2012. The results were compared to simulation results of HOMWRS and observed data. Average $R^2$, EI, RMSE of ARWS were 0.76, 0.46, 1.78 (m), average $R^2$, EI, RMSE of HOMRWS were 0.88, -0.14, 2.37 (m) respectively. Considering statistical variances, water level simulation results of ARWS were more similar to observed data than HOMWRS. ARWS can be useful to estimate reservoir water supply and assess hydrological processes of agricultural water district.