• 제목/요약/키워드: water spray head

검색결과 27건 처리시간 0.032초

소화용 스프링클러 헤드의 살수분포 및 수적 특성에 대한 연구 (The Study on Characteristics of Water Spray and Droplet from Fire Sprinkler Head)

  • 추병길;최종욱;차경세
    • 한국안전학회지
    • /
    • 제16권2호
    • /
    • pp.13-21
    • /
    • 2001
  • The effect of water spray for the fire sprinkler depends on droples distribution over maximum possible floor area. The present study are carried out for the characteristics of water spray and droplets experimentally and numerically km two fire sprinkler heads which are CHM head and CHl heal CHl head is self-production and CHl head is widely used up to date. As the result of using CHM head, water spray and droplets are distributed over large area because CHM head has smooth surface and non-flamed shape. When the pressure of fire sprinkler head is low, SMD(sauter mean diameter) is large and when the pressure of fire sprinkler head is high, SMD is small.

  • PDF

화재 진압용 스프링클러 헤드 유형에 따른 살수 균일도 분석 (Analysis of Water Flux Uniformity for Various Fire Sprinkler Head Type)

  • 방새미;안찬섭;김태훈
    • 한국분무공학회지
    • /
    • 제28권2호
    • /
    • pp.97-104
    • /
    • 2023
  • A sprinkler is a fire suppression system that extinguishes combustible materials in the early stages of a fire, creating a spray. However, spray formation method of the sprinkler can result in an uneven distribution of water spray on the surface of combustible materials. It is necessary to ensure a consistent water flux density regardless of the spray direction and angle. In this study, the water flux distribution was analyzed for the various types of sprinkler head: circular, flush, pendent, and upright types. All sprinkler heads have a K-factor of 80 LPM/(0.1MPa)0.5. In this study, water collection cubes were used to examine the water flux distribution. The upright type sprinkler head showed a low standard deviation in total sprayed area, indicating a high level of uniformity. The upright type head showed the lowest standard deviation in the radial direction, and also showed the lowest standard deviation in the azimuthal direction. Upright sprinkler head has no obstructing structure along the path of droplets after they are generated. For this reason, upright sprinkler head showed the most uniform water flux distribution on the floor.

인랙스프링클러 헤드의 살수 특성 (Spray Characteristics of In-Rack Sprinkler Heads)

  • 김종훈;정우인;명상엽;정기신;김운형
    • 한국화재소방학회논문지
    • /
    • 제31권3호
    • /
    • pp.54-62
    • /
    • 2017
  • 본 연구는 랙크식 창고에 적용되고 있는 인랙스프링클러의 살수특성을 알아보기 위해 수행되었다. 국내산 헤드와 미국산 헤드를 대상으로 흐름성능실험, 방사각도 측정, 각도별 밀도측정 등이 수행되었다. 국내산 헤드의 경우 넓은 방사범위를 가지고 있으며, 미국산 헤드의 경우 국내산 헤드에 비하여 좁은 각도를 가지고 있다. 동일한 K80헤드로 비교해보면 국내산 헤드는 직접 살수가 어려운 부분으로 물을 보낼 수는 있으나, 각도별 살수밀도는 낮은 수준이었다. 미국산 헤드는 상대적으로 좁은 각도 내에 국내산에 비하여 많은 량의 물을 보낼 수 있는 것으로 나타났다. 결론적으로 랙크식 창고의 평면적으로 2열 이상으로 배치된 가연물에 대해서는 화재확산을 억제하거나 진압 효과를 가지기 위해서는 페이스 스프링클러의 도입과 함께 지그재그 형태로의 배치를 통해 살수장애지역을 최소화 해야 할 것으로 보인다.

스프링클러 헤드의 방향성 살수 특성 비교 연구 (Directional Water Spray Characteristics of Sprinkler Heads)

  • 박용환
    • 한국화재소방학회논문지
    • /
    • 제18권4호
    • /
    • pp.35-41
    • /
    • 2004
  • 스프링클러 헤드의 살수 특성은 화재의 초기 진화 성능을 결정짓는 매우 중요한 요소이며, 이는 헤드노즐의 형상에 크게 좌우된다. 본 연구에서는 국내 시장점유율이 가장 높은 4개 제조사의 헤드 제품군에 대하여 방수계수 값과 방향성 살수 분포 특성을 규명하였다. 방수계수는 모두 기준 값을 상회하였지만, 헤드 종류별로 동일한 설계 값을 가짐에도 불구하고 큰 차이를 보이는 것으로 나타나 제품 간 품질차이가 큰 것으로 나타났다. 다만, 방수계수는 압력변화에 관계없이 비교적 일정하게 나타났다. 방향별 살수 분포 특성은 일부 헤드 샘플의 경우 매우 심각한 편향 분포를 나타냄으로써 성능개선 연구가 시급한 것으로 판단되었다

터널 물분무소화설비의 살수밀도분포에 대한 실험연구 (Experimental study on the spray density distribution of water spray system in road tunnel)

  • 소수현;박경환
    • 한국터널지하공간학회 논문집
    • /
    • 제13권1호
    • /
    • pp.1-8
    • /
    • 2011
  • 장대 도로터널 및 위험도가 높은 도로터널에 설치되고 있는 물분무소화설비는 성능과 관계된 단위면적당 방수밀도에 대한 검증과정이 없이 사용되어 왔다. 본 연구는 도로터널에 물분무소화설비에 노즐을 설치하여 기준압력에서 방수시험을 실시하여 기준을 만족하는지 여부를 확인하였다. 결론적으로 모든 노즐이 기준을 만족하지 못하였다. 이런 결과는 도로터널용 물분무노즐을 검증하는 시험기준이 없고, 실제 시험을 통한 검증 과정이 존재하지 않았기 때문이라고 판단된다. 따라서 물분무노즐의 성능을 시험할 수 있는 기준의 마련과 설치된 시설을 검증하는 제도적인 보완이 필요하다.

드렌처 헤드의 형상에 따른 수막특성에 관한 실험적 연구 (An Experimental Study on the Effects of the Shape of a Drencher Head on the Characteristics of a Water Curtain)

  • 이승철;김봉준;이재오;박충화;황철홍
    • 한국화재소방학회논문지
    • /
    • 제30권3호
    • /
    • pp.86-93
    • /
    • 2016
  • 드렌처 헤드의 형상이 화재확산 차단을 위한 수막의 유동특성 및 복사 감쇠에 미치는 영향에 관한 실험적 연구가 수행되었다. 헤드의 형상인자로서 오리피스 출구와 반사판의 거리(h) 그리고 반사판의 직경(D)이 변화되었으며, 오리피스의 직경(d)은 고정되었다. 주요 결과로서, h의 증가는 방수량과 분사각의 증가를 가져오지만, D의 증가에 따라 분사각의 변화는 감소한다. D의 증가는 방수량 증가에 매우 작은 영향을 미치며, 분사각의 큰 감소를 초래한다. 또한 D의 증가는 보다 편평한 수막 패턴을 생성시킬 수 있지만, 분사각 내의 더 낮은 액적 균일도를 가져온다. 작동압력의 증가에 따라 평균 액적직경은 크게 감소하지만, 일정한 압력 조건 하에서 헤드 형상변화는 액적직경 변화에 큰 영향을 주지 않는다. 마지막으로 일정한 작동압력의 조건에서 드렌처 헤드의 복사 감쇠효과는 h 및 D의 변화에 따른 방수량과 액적 균일도에 의해 각각 영향을 받는 것으로 확인되었다.

2-유체 분무에서 액체미립화에 대한 초음파의 영향에 관한 연구 (A Study on Ultrasonic Effects for the Atomization in a Twin-Fluid Spray)

  • 주은선;정진도;송민근
    • 한국분무공학회지
    • /
    • 제3권4호
    • /
    • pp.50-57
    • /
    • 1998
  • The utilization of resonance should be considered to get the maximum effect of ultrasonic to atomize liquid. The ultrasonic generator, transducer, horn, and all attached parts are used to produce the resonance, and specially the characteristics of liquids such as liquid load, property, and etc., for the liquid atomization affinity are considered. In this study, the variable device of liquid load was made and distilled water and city water selected as experimental liquids were sprayed by a twin-fluid spray method and their diameters, distributions, and spray quantum of spray droplets were measured by the light scattering system. And all data were observed, compared and considered relatively. In results, a lot of phenomena of liquid atomization affinity by ultrasonic appeared in accordance with liquid loads, namely head h.

  • PDF

자율형 소화모니터 노즐의 분사 성능에 대한 실험 연구 (Experimental Study on Spray Performance of Nozzles for Autonomous Fire Fighting Monitor)

  • 유성선;김형태;서정화
    • 대한조선학회논문집
    • /
    • 제59권2호
    • /
    • pp.80-88
    • /
    • 2022
  • A systematic experimental study is carried out for the fire fighting monitor nozzle of 65A diameter to design and manufacture a new nozzle with better water spray performance than available domestic nozzles. The nozzle inlet pressure, flow rate and reach for the discharged water from the nozzle are measured by utilizing the experimental facility consisting of two pumps and piping system with a flow meter and pressure gauges. It was found that the baffle position and baffle head chamfering were the most sensitive design factors to be remarkably changed in the flow rate of the discharged water. Also, It was confirmed that the baffle position and the water exit area had the significant effect on the change in reach distance. The results obtained from this study are expected to be used effectively to design new nozzles with excellent spray performances and also to validate numerical analysis results for evaluating the water spray performance of fire fighting monitor nozzles.

요소수 인젝터의 작동 변수에 따른 분무미립화 성능에 관한 연구 (Study on Spray Atomization Characteristics Depending on the Operating Parameters of Urea Injector)

  • 김동환;박준규;박성욱
    • 한국분무공학회지
    • /
    • 제24권1호
    • /
    • pp.1-7
    • /
    • 2019
  • This study was carried out to analyze the spray characteristics as a function of the operating parameters of urea injector used in Urea-SCR system of passenger diesel vehicle. Spray visualization and PDPA experiment were performed to analyze the macroscopic spray development and atomization performance of urea-water-solution. For the urea injector, the deformation of the spray head does not appear to be significant because it operates at a low pressure conditions, and the liquid core and primary droplet are observed throughout the operating conditions. No increase in atomization is seen when the operating pressure is increased, and the spray develops linearly due to poor atomization characteristics. The macroscopic spray behavior of the low-pressure urea injector is predictable through the modification of the Hiroyasu equation.

재래시장의 화재확산 방지를 위한 수막설비 설치 지침 (The Water Curtain Installation Guideline for Fire Spread Prevention in Market)

  • 최정욱;조성우
    • 설비공학논문집
    • /
    • 제28권7호
    • /
    • pp.269-274
    • /
    • 2016
  • This paper aims to suggest the water curtain installation guideline for prevention of fire spread. The water curtain systems play a role in preventing fire spread which is caused by fire flames and radiation heat release from a fire source. The radiation attenuation ratio is affected by the water droplet size, vertical distance from the nozzle and flow rate. This study suggests the water curtain installation guideline as follows : (1) Investigation of a reference store array (2) Calculation of the number of drencher heads (3) Review of the relationship between droplet size and attenuation factor depending on the height of the drencher head (4) Review of a drencher head array and spray overlapping. The reference traditional market in which a fire compartment is installed using a water curtain can be predicted to have a radiation attenuation ratio of 50%.