• Title/Summary/Keyword: water purifier

Search Result 89, Processing Time 0.027 seconds

Development of Portable Hybrid Water Purifier System (재난·재해용 포터블 하이브리드 정수시스템 개발)

  • Ryu, Ji-Hyeob;Choi, Rang-Kyu;Park, Hun
    • Journal of Korean Society of societal Security
    • /
    • v.3 no.2
    • /
    • pp.47-55
    • /
    • 2010
  • It was developing of portable hybrid water purification system for clean water production in the disaster area. because there are no way to supply a drinking water to the victims of calamity. currently, the government has been supplying bottled water to victims. but it is a limit to the reserves. It is composed of a filter, a feed pump, a solar-cell, a controller, and a case and is possible supplying a drinking water not to limit time and a place. Field test was carried out to developed portable water purification system and the purified water was satisfied a criterion for a drinking water.

  • PDF

Convergence Study on Organic Sludge Treatment System (유기성 슬러지 처리 시스템에 관한 융합연구)

  • Han, Doo-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.10
    • /
    • pp.213-217
    • /
    • 2020
  • An eco-friendly water purifier was developed using natural minerals, plants, and sludge from water purification plants. A wastewater complex treatment system using this water purification agent was developed. The wastewater complex treatment system goes through the process of inflow of contaminated water, input of water purification agent, operation of a pressurized flotation device, sludge flotation, sludge collection and treatment water discharge. This device was applied to the removal of green algae in livestock desorption liquid, broiler washing water, factory wastewater, sewage treatment plant and pond to obtain excellent removal rate. The use of natural water purification agents for organic waste purification has not been investigated.

The Foul Smelling from Sewer Pipe near Large Apartment Complexes and its Countermeasures I: Characteristics of the Foul-Smelling Sewer Pipe in Residential Areas (대규모 아파트 단지주변 하수관로의 악취 발생과 대책 1: 주거지역 하수관로의 악취 발생 특성)

  • Lee, Jang-Hown;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.621-629
    • /
    • 2007
  • This study intends to investigate the characteristics of the foul smell of sewer pipes near large apartment complexes as complaints about offensive odors have drastically increased in urban residential areas. Targeting apartments where people actually complained about foul orders, the study result revealed that components in the smell of the water-purifier tank of the target apartment were very similar to those of sewage treatment plants and night soil treatment plants. Measuring components of odors inside the management layer of tank showed that the concentration of hydrogen sulfide was 10ppm, which is approximately 160 times the safety standard of 0.06ppm; the concentration of mercaptan was 0.9ppm, which is about 220 times the safety standard of 0.004ppm. The source materials of foul odors were discharged outside through ducts, and those households living near outlets producing bad smell complain that it gets worse depending on the air pressure or wind direction and strength, and they could not even open windows. As well, these source materials were transferred by discharge pumps to public sewer pipes outside the apartment complex. While discharge pumps starts operating, they remain on the sewer pipe and then begin to spread over to roads through small openings of manholes on the road. Then, the smell offends passers-by and residents near the road, leading to a lot of complaints. The study results suggest that, among the sources of foul odors in sewer pipes of residential areas, especially those from the water-purifier tank of large apartments, hydrogen sulfide should be the main target for follow-up treatment.

Cleaning of the Waste Reverse Osmosis Membrane Filters for the Household Water Purifier and Their Performance Enhancement Study (정수기용 역삼투 폐분리막 필터의 세정 및 성능 향상 연구)

  • Cho, Young Ju;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.27 no.3
    • /
    • pp.232-239
    • /
    • 2017
  • In this study, the regeneration investigation for waste reverse osmosis membrane filters which were discarded after use for the household water purifiers has been carried out. Sodium hydroxide, sodium bisulfate, and ethylenediamine tetra acetic acid(EDTA). as the chemical cleaning agents were used. And they were in-situ cleaned with the micro-bubble generator as well. The best result was obtained when both 0.1% EDTA and micro-bubbles were used for 30 min cleaning. Thus, when the performance of the brand new RO membrane and restorated RO membrane were compared, the flux, 19.9%, the recovery ratio 45% were enhanced while the salt rejection was reduced for NaCl 100 mg/L solution, in other words, it has been recovered to the original brand new RO membrane filter. Also the removal of pollutants on membrane surface was confirmed in a naked eye through the scanning electron microscopy. Finally, this research has provided the possibility of the re-use of the waste RO membrane filters of household water purifier which were reclaimed or incinerated after use.

The Strategic Model for the Late Mover: Evidence from the Defiance Case of LG Electronics (후발기업의 전략 모델에 대한 탐색적 연구 : LG전자의 사례를 중심으로)

  • Choi, Kyu-Seong;Shin, Ho-Sang
    • Journal of Distribution Science
    • /
    • v.14 no.10
    • /
    • pp.81-91
    • /
    • 2016
  • Purpose - This study proposes a strategic model for the late mover to effectively penetrate an industry that is dominated by a leading company. Thus, this study presents strategic implications for several late movers in overcoming the advantages of the leading company. Research design, data, and methodology - This study begins with a literature review followed by the formation of a strategic model that consists of: Repositioning, Utilization of Competence, Strategic Leadership, and Innovation. Specifically, this research analyzes LG Electronics (LG) as an example and investigates how LG infiltrates and grows in the water purifier market, overcoming the advantages of the powerful leading company. Results - The major steps taken by LG are summarized into four. First, LG studied the market, which had been conventionally treated as a single market. To penetrate the market, LG founded a new, special market segment. Subsequently, LG further segmented the market, executing a marketing strategy for each segment. Second, the unbending will of top managers was a key factor that addressed the challenge persistently. Third, even though LG was the late mover in the water purifier market, it had several technology competences such as compressor, refrigeration cycles, and algorithms. LG had profound knowledge in technology and used it effectively. Fourth, LG created a premium market through three innovative and distinguished factors such as the stainless water tank, sterilization service, and luxury design. Conclusions - This research draws four key findings from the example of the late mover in the water purifier industry: the reestablishment of a strategic position based on environmental change is an effective strategy for the late mover; strategic leadership is an important motive to generate late mover performance; and the late mover can utilize its existing knowledge and resources to overcome the first mover, such as presenting new added value compared to existing products as an effective catch-up strategy. Consequentially, through the study of performance determinants and the market penetration strategy of the late mover, this research has significance in providing basic material for companies trying to penetrate the market.

Bacteria on Granular Activated Carbon for Tap Water Purifier (정수용 입상활성탄상의 세균)

  • 이동근;하종명;이재화
    • Journal of Life Science
    • /
    • v.14 no.1
    • /
    • pp.163-166
    • /
    • 2004
  • To investigate the bacterial growth on granular activated carbon (GAC) for the purification of tap water, fixed bed columns with GAC were installed and operated at an empty bed contact time (EBCT) of 1 min$\pm$0.08 min. There was no bacterial breakthrough in the spring. However, the bacterial concentrations of effluent (($10^3$ CFU/ml) were higher than that of the influent ($10^2$ CFU/ml) after 10 day operation in summer. More bacteria were enumerated near the entering point of the tap water, while the bacterial activities were similar throughout the columns. Different bacterial species were detected on coal- and plant-based GAC, although the dominant genus was the same as Acinetobacter.

A Study on the Analysis of Fire Mechanisms in Electronic Products due to Failure and Malfunction of Thermostats Through Fire Cases and Reproduction Experiments (화재사례 및 재현실험을 통한 온도조절장치 고장 및 오동작으로 인한 전자제품 화재 메커니즘 분석)

  • Jeong-il Lee;Jong-Hwa Im
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.1
    • /
    • pp.31-38
    • /
    • 2024
  • In this paper, as there are many cases of fires occurring due to the failure or inoperability of the thermostat of electronic products, the purpose is to test and analyze the risks and probabilities through fire cases and reproduction experiments, and suggest countermeasures. Among electronic products, water purifiers are composed of a refrigerant system with a compressor to make cold water, a heating device to make hot water, and an electric device used as an energy source. Due to the nature of the water purifier manufacturing, these devices are subject to a lot of moisture and dust. etc. exist in large quantities and use electrical energy, so there is a possibility of fire due to short circuit in the wire, electrical abnormal overheating (tracking phenomenon) in the thermostat, electronic board, starting relay, etc., and overheating of the heating device (Band Heater). there is. Therefore, in order to prevent fires from these devices, a system to remove foreign substances inside the water purifier is necessary, the use of heat-resistant (fire-resistant) wires for electrical devices is essential, and the use of non-combustible materials (semi-combustible materials) for each part is necessary to prevent fire. The risk must be eliminated through prevention and combustion expansion prevention devices.

The Protective Countermeasure of Water Purifier PCB according to Abnormal Voltage (이상전압에 따른 정수기 PCB의 보호대책)

  • Kim, Dong-Ook;Moon, Hyun-Wook;Lee, Ki-Yeon;Kim, Hyang-Kon;Choi, Chung-Seog
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.64-70
    • /
    • 2007
  • The electrical accident results from an insulation blackdown by over-voltage, an overheating by the excess of allowable current, a deterioration performance by the passage of time, and so on. This paper discusses how to improve the power control system of PCB in water purifier. The protecting device of present power supply control system in water purifier is composed of the varistor device which acts only for impulse-type surges. So the present system can not be protected others except the surge of impulse-type. The newly-suggested power control system in this paper is designed to protect the system by disconnecting power supply through SSR(Solid State Relay) if the value of input voltage is exceeded the setting value.

Research on Improvement of Power Control System of Cold & Hot Water Purifier (냉온정수기의 전원 제어 시스템 개선에 관한 연구)

  • Lee, Ki-Yeon;Choi, Chung-Seog;Kim, Dong-Ook;Kim, Hyang-Kon;Kim, Dong-Woo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.1
    • /
    • pp.45-50
    • /
    • 2007
  • In this paper, this paper discusses how to improve the power control system of cold and hot water purifiers, in particular, system protecting device against abnormal voltage. The existing power supply control system came with a protecting device composed of varistor device only for impulse-type surges. Even though the existing system senses surge other than impulse-type, the system can not be protected. Accordingly, a new type of power control system was designed to protect the system from surge and ultimately prevent electricity accidents. The power control system suggested in this paper will be designed to protect the system by sensing input voltage and discontinuing power supply by means of SSR if voltage exceeding set value is sensed. To test the designed system, surge was imposed on the existing system and processes of system failure were experimented before safety of the designed power control system was simulated via P-spice program developed by Orcad in order to examine safety and reliability of the system.