• 제목/요약/키워드: water power

검색결과 5,391건 처리시간 0.035초

Effect of water content on near-pile silt deformation during pile driving using PIV technology

  • Jiang, Tong;Wang, Lijin;Zhang, Junran;Jia, Hang;Pan, Jishun
    • Geomechanics and Engineering
    • /
    • 제23권2호
    • /
    • pp.139-149
    • /
    • 2020
  • Piles are widely used in structural foundations of engineering projects. However, the deformation of the soil around the pile caused by driving process has an adverse effect on adjacent existing underground buildings. Many previous studies have addressed related problems in sand and saturated clay. Nevertheless, the failure mechanism of pile driving in unsaturated soil remains scarcely reported, and this issue needs to be studied. In this study, a modeling test system based on particle image velocimetry (PIV) was developed for studying deformation characteristics of pile driving in unsaturated silt with different water contents. Meanwhile, a series of direct shear tests and soil-water characteristic curve (SWCC) tests also were conducted. The test results show that the displacement field shows an apparent squeezing effect under the pile end. The installation pressure and displacement field characteristics are sensitive to the water content. The installation pressure is the largest and the total displacement field is the smallest, for specimens compacted at water content of 11.5%. These observations can be reasonably interpreted according to the relevant unsaturated silt theory derived from SWCC tests and direct shear tests. The variation characteristics of the soil displacement field reflect the macroscopic mechanical properties of the soil around the pile.

방파제 부착형 파력발전시스템의 터빈설치 방법에 따른 출력특성에 관한 연구 (Study of Power Output Characteristics of Wave Energy Conversion System According to Turbine Installation Method Combined with Breakwater)

  • 이헌석;오진석
    • 한국해양공학회지
    • /
    • 제29권4호
    • /
    • pp.317-321
    • /
    • 2015
  • Many kinds of generation systems have been developed to use ocean energy. Among these, with the use of an oscillating water column (OWC) for power generation is attracting attention. The OWC-type wave power generation system converts wave energy into electricity by operating a generator turbine with the oscillating water level in a column of water. There are two ways to convert wave power into electricity using an OWC. One uses a cross-flow turbine using the water level inside the OWC. The other method uses the flow of air in a Wells turbine, which depends on the water level. An experiment was carried out using a 2-D wave tank in order to minimize the number of empirical tests. The design factors were taken from Koo et al. (2012) and the experimental environment assumed by free surface motion. This paper deals with characteristics of two types of wave energy conversion systems combine with a breakwater. One model uses an air-driven Wells turbine and a cross-flow water turbine. The other type uses a cross-flow water turbine. Wave energy converters with OWCs have mostly been studied using air-driven Wells turbines. The efficiency of the cross-flow turbine was about 15% higher than that of the other model, and the water level of the OWC internal chamber for the cross-flow water turbine and air-driven Wells turbine was less than about 40% lower than the one using only the cross-flow water turbine.

결정질 실리콘 태양광시스템의 물 발자국 산정에 대한 연구 (Analysis on the Water Footprint of Crystalline Silicon PV System)

  • 나원철;김영환;김경남;이관영
    • 청정기술
    • /
    • 제20권4호
    • /
    • pp.449-456
    • /
    • 2014
  • 기후변화로 인한 국지적인 이상가뭄 빈발 및 물수지 관련 불확실성 증가 등으로 각국에서는 사용가능한 담수량 확보, 즉 물안보 문제가 크게 대두되고 있다. 사용가능한 담수량 중 상당부분이 전력을 생산하는 발전 분야에도 사용되기 때문에 그 중요성이 점차 증대하고 있다. 신재생에너지원인 태양광발전은 설비제조, 설치 및 운전의 전 과정(life cycle)에서 수자원을 소비하지만 전통적인 에너지원인 화력발전이나 원자력발전에 비하면 상대적으로 수자원을 적게 사용한다는 장점이 있다. 본 연구에서는 태양광시스템의 원료채취부터 운영발전까지 물 사용량을 알아보기 위해 전 과정의 물 발자국을 측정하여 그 결과를 분석했다. 물 발자국 산정결과 태양광시스템의 전체 물 발자국은 $0.989m^3/MWh$이며, 폴리실리콘과 태양전지 공정에서 물 발자국이 높게 나타났다. 폴리실리콘 공정은 에너지 다소비 공정이기 때문에 냉각수 사용량이 많았고 태양전지 공정에서는 고효율 결정질 실리콘 세척을 위한 탈 이온수(deionized water) 사용량이 많았기 때문에 물 발자국이 높은 것으로 보인다. 태양광발전은 기존 에너지원보다 물 사용량이 적은 발전원임을 확인할 수 있었으며, 에너지 분야의 물 사용량을 절감할 수 있는 가치를 가지고 있음을 알 수 있다. 향후 에너지정책 결정에 있어서 신재생에너지의 부가적인 가치로서 물 발자국 개념의 도입이 중요하다.

전력계통안정화장치(PSS) 수력발전소 적용분석 (The Application Analysis of Power System Stabilizer in Hydraulic power plant)

  • 옥연호;임재일;박지군;곽원구;이광연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.63-65
    • /
    • 2007
  • Recently with increase consumption of electric power, the scale of the electric system becomes bigger and complex. Then, it is increasing the hardship in the operation of electric system and the continuance of stability. Especially, as the differences between demand and supply in electric power keeping low frequency oscillating attenuation from electric power have been very important in the continuance part of stability. The more control time of electricity system is getting faster with digitalization the more stability of electricity system is getting worse. As solutions of these problems, by establishing Power System Stabilizing Controller putting PSS output signal and putting damping to vibration of the rotor at generators's AVR in area where is oscillated, We are willing to contribute the electricity system by holding in generator output vibration.

  • PDF

침수 상용전원에 의한 감전위험성 검토 (A Study on the Electric Shock due to Submerged Power Source)

  • 정종욱;정진수
    • 조명전기설비학회논문지
    • /
    • 제21권6호
    • /
    • pp.71-76
    • /
    • 2007
  • 본 논문에서는 상용전원이 침수되었을 경우, 이에 의한 인체 감전의 위험성을 실증실험을 통해 검토하였다. 실험을 위해 한쪽 벽면에 노출된 충전부가 설치된 모의수조를 구축하고 내부에 도전성 수용액을 채운 후, 전원으로부터의 거리, 방향, 도전성 수용액의 전도율 및 수위에 따른 전위를 측정하였다. 실험 결과 수중에 설치된 전원장치로 인한 전위분포는 거리에 따라 달라지지만, 침수 수용액의 도전율, 노출된 충전부로부터의 각도 및 측정높이는 전기적으로 미치는 영향이 거의 없음이 확인되었다.

CORROSION BEHAVIOR OF AUSTENITIC AND FERRITIC STEELS IN SUPERCRITICAL WATER

  • Luo, Xin;Tang, Rui;Long, Chongsheng;Miao, Zhi;Peng, Qian;Li, Cong
    • Nuclear Engineering and Technology
    • /
    • 제40권2호
    • /
    • pp.147-154
    • /
    • 2008
  • The general corrosion behavior of austenitic and ferritic steels(316L, 304, N controlled 304L, and 410) in supercritical water is investigated in this paper. After exposure to deaerated supercritical water at $480^{\circ}C$/25 MPa for up to 500 h, the four steels studied were characterized using gravimetry, scanning electron microscopy/energy dispersive X-ray spectroscopy(SEM/EDS), X-ray photoelectron spectroscopy(XPS), and X-ray diffraction(XRD). The results show that the 316L steel with a higher Cr and Ni content has the best corrosion-resistance performance among the steels tested. In addition to the oxide layer mixed with $Fe_{3}O_{4}$ and $(Fe,Cr)_{3}O_{4}$ that formed on all the samples, a $Fe_{3}O_{4}$ loose outer layer was observed on the 410 steel. The corrosion mechanism of stainless steels in supercritical water is discussed based on the above results.

단류식 창조발전의 조력발전소 최적화 운영 Model 개발에 관한 연구 (A Study on Developement of Optimization Model for Single Action Tidal Power Station)

  • 김현한;김만기;김준규;옥연호;김광호;정종찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1144_1145
    • /
    • 2009
  • Tidal power station is using the difference of the ebb and flow and the single action tidal power is dependent on tide amplitude and basin volume. Therefore the inflow of basin in rainy season has also effect on the daily power. Also if operating units are changed then starting head too changed. Therefore the number of units are very important for the optimization model. According to our study the primary point when we make a determination of optimization is starting head and governorl control mode. On this study optimization model for tidal power station is considered all of this conditions.

  • PDF

원전 복수계통 열교환기의 이음 원인 분석 (Abnormal Sound from Heat Exchanger of Condensate Water System at Nuclear Power Plant)

  • 이준신;이욱륜;김태룡
    • 한국소음진동공학회논문집
    • /
    • 제26권4호
    • /
    • pp.469-474
    • /
    • 2016
  • Abnormal sound was heard from a heat exchanger of condensate water system in a nuclear power plant, which was identified as impact sound of a loose part later. Nuclear power plants are normally equipped with loose part monitoring system for primary water system, but not for secondary water system. The abnormal sound was analyzed by using the impact signal-processing methodology based on the Hertz theory. The predicted results for impact location and size of the loose part showed good agreement with those of the actual loose part found during the overhaul period in the plant. So, this analysis methodology for the impact signal will be widely utilized for the primary and secondary side of the nuclear power plant.

발전소 급수계통 부식생성물 농도 측정에 관한 연구 (Study on The Measurement of Corrosion Product Concentration in The Feed Water System of A Power Plant)

  • 문전수;이재근
    • Corrosion Science and Technology
    • /
    • 제10권4호
    • /
    • pp.151-155
    • /
    • 2011
  • The iron oxide particles could be resulted from the corrosion of the circulating water system of a power plant. Because it may be one of the trouble materials which affect the power generation efficiency due to the deposition on steam generator tube and turbine blade, the continuous observation of its concentration is very important. The laser induced break-down detection (LIBD) technology was applied to monitor continuously the concentration of corrosion products with the detection limit of ppb level. The measurement system consists of a Nd:YAG pulsed laser, a polarizing beam splitter, a flow-type sample cell, an acoustic emission sensor, a high speed data acquisition board, a personal computer, etc.. The performance test results confirmed that this technology can be effective to monitor the corrosion product concentration of the circulating water system of a power plant.

500MW급 석탄화력발전소 보일러 급수펌프 유량 제어기 개발 (The Development of Feed-Water Flow Controller of Boiler Feed-Water Pump in 500MW Class Coal-Fired Power Plant)

  • 임건표;최인규;박두용;정태원;김건중
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1663-1672
    • /
    • 2010
  • The boiler feed-water pump controllers which can be applied to 500MW class coal fired power plants was developed. The validity of the developed controllers was shown via the applied test result in a power plant. It is expected that the developed controllers are used to retrofit the existing controllers that have surpassed their expected service life and have limited spare parts, and contributes to the stable operation of plants. Based on the collected data and analysis, new control schemes were developed and implemented during the overhaul period in the new control systems. During normal operation, feed water could be supplied to the boiler with the capability of the 1600t/h flow without any problems in automatic mode of controllers. In this study, the feed-water pump controllers were developed successfully. In addition, it is expected that the developed controllers can make the plant operation more stable and can be applied to a lot of power plants.