• 제목/요약/키워드: water pollution control center

검색결과 66건 처리시간 0.029초

Application of nanofiltration membrane for the River Nile water treatment in Egypt: Case study

  • Jamil, Tarek S.;Shaban, Ahmad M.;Mansor, Eman S.;Karim, Ahmed A.;El-Aty, Azza M. Abd
    • Membrane and Water Treatment
    • /
    • 제9권4호
    • /
    • pp.233-243
    • /
    • 2018
  • In this manuscript, $35m^3/d$ NF unit was designed and applied for surface water treatment of the River Nile water. Intake of Embaba drinking water treatment plant was selected to install that unit at since; it has the lowest water quality index value through the examined 6 sites in greater Cairo area. The optimized operating conditions were feed and permeate flow, 40 and $7m^3/d$, feed pressure 2.68 bar and flux rate $37.7l/m^2h$. The permeate water was drinkable according to Egyptian Ministerial decree 458/2007 for the tested parameters (physic-chemical, heavy metals, organic, algal, bacteriological and parasitological). Single and double sand filters were used as pretreatment for NF membranes but continuous clogging for sand filters moved us to use UF membrane as pretreatment for NF membrane.

Status, Trend and Strategy on Municipal Wastewater Management in China

  • Wang, Baozhen;Wang, Lin;Liu, Shuo;Wang, Li;Wang, Zheng
    • 한국습지학회지
    • /
    • 제9권1호
    • /
    • pp.47-60
    • /
    • 2007
  • The rapid development of economy in China at the expense of consuming huge amount of energy and resources, water resource in particular, which has resulted in the production and discharge of increasing amount of wastewater to the water environment. In order to effectively control the increasing water pollution trend, the State Council has stipulated that all the cities with population over 500,000 should reach wastewater treatment rate of 60% by 2005, and all the cities should reach the rate of 60% by 2010, of which Capital Beijing and all the province capital cities and important tourism cities should reach 70% then. By the end of 2005, of the 661 cities in China, 393 have built and operated municipal wastewater treatments with a total number of 790 sets, total treatment capacity of $80.91{\times}106m^3/d$ and total treatment rate of > 48%. Other 73 cities have started the construction of municipal wastewater treatment plants, and other 168 cities have started to prepare, planning and design of wastewater treatment plants. Most of municipal wastewater treatment plants in big cities in China operate normally and perform well with good quality of effluent in terms of wastewater treatment train, but the sewage sludge treatment is usually poor with big problems. It has been found that the small scale WWTPs using activated sludge process in the towns are usually operated and maintained abnormally because of lack of fund, skilled operators and energy. It is therefore suggested that the small scale MWWTPs in small cities and towns adopt appropriate technologies, of which the most available ones are multi-stage ponds, constructed wetlands and the combination of them for further purification and reuse of treated wastewater.

  • PDF

Inhibition of Microcystis aeruginosa by the Extracellular Substances from an Aeromonas sp.

  • Liu, Yu-Mei;Chen, Ming-Jun;Wang, Meng-Hui;Jia, Rui-Bao;Li, Li
    • Journal of Microbiology and Biotechnology
    • /
    • 제23권9호
    • /
    • pp.1304-1307
    • /
    • 2013
  • Growth of Microcystis aeruginosa could be inhibited significantly within 24 h by the extracellular substances prepared from Aeromonas sp. strain FM. During the treatment, the concentration of extracellular soluble carbohydrates increased significantly in algal culture. Morphological and ultrastructural changes in M. aeruginosa cells, including breakage of the cell surface, secretion of mucilage, and intracellular disorganization of thylakoids, were observed. HPLC-MS analysis showed that the extracellular substances of Aeromonas sp. strain FM were a mixture of free amino acids, tripeptides, and clavulanate. Among these, the algaelysis effects of lysine and clavulanate were confirmed.

Algicidal Activity of a Dibenzofuran-Degrader Rhodococcus sp.

  • Wang, Meng-Hui;Peng, Peng;Liu, Yu-Mei;Jia, Rui-Bao;Li, Li
    • Journal of Microbiology and Biotechnology
    • /
    • 제23권2호
    • /
    • pp.260-266
    • /
    • 2013
  • Rhodococcus sp. strain p52, a previously isolated dibenzofuran degrader, could effectively inhibit the growth of cyanobacteria, including species of Microcystis, Anabaena, and Nodularia. When strain p52 was inoculated at the concentration of $7.7{\times}10^7$ CFU/ml, 93.5% of exponentially growing Microcystis aeruginosa ($7.3{\times}10^6$ cells/ml initially) was inhibited after 4 day. The threshold concentration for its algicidal activity against M. aeruginosa was $7.7{\times}10^6$ CFU/ml. Strain p52 exerted algicidal effect by synthesizing extracellular substances, which were identified as trans-3-indoleacrylic acid, DL-pipecolic acid, and L-pyroglutamic acid. The effective concentrations of trans-3-indoleacrylic acid and DL-pipecolic acid against M. aeruginosa were tested to be 0.5 mg/l and 5 mg/l, respectively.

비점오염원 관리지역의 선정 기법에 관한 연구 (A Study for the Selection Method of Control Area of Nonpoint Pollution Source)

  • 박상현;정우혁;이상진;임봉수
    • 한국물환경학회지
    • /
    • 제26권5호
    • /
    • pp.761-767
    • /
    • 2010
  • This study introduces a model of territorial analysis on Chungcheongnam-do Nonsan-chun valley area, which gives an example of a method of selecting the management area for non-point pollution source from land use to help eliminate its source. High discharge load per unit area signify high level of land ratio with high level of basic unit of development load (including factory sites, school sites, roadways), which mean that there are a significant level of urbanization. It is these areas with the examination of the water quality of the nearby river that should be considered as the management area for non-point pollution source. Thus, the management area for non-point pollution source should be sought in areas with high discharge load per unit area and high density of water pollution area. When level of drainage is high the pollution density level is relatively lower, and when the level of drainage is low the density level is relatively higher. The level of pollution from non-point pollution source is much lower with more water flowing through. The possible non-point pollution source areas that were selected with these standards were then examined with the distance from the river, the slope angle, land usage, elevation, BOD discharge density load, T-N discharge density load, T-P discharge density load, and were given a level one through five. Out of the possible areas Nonsan-si Yeonmu-eup Anshim-li was the densest area, and it was given level one. The level one area should be examined further with the field analysis to be selected as the actual management area for non-point pollution source.

호소 퇴적물 내부생산성 오염도 영향 평가 및 용출특성에 관한 연구 (The evaluation of pollution level and release characteristics by inner productivity in the sediment of lake)

  • 이상은;최이송;이상근;이인호;오종민
    • 환경영향평가
    • /
    • 제21권1호
    • /
    • pp.81-91
    • /
    • 2012
  • In this study, it is grasped the status of nutrients through an investigation of release characteristics and physicochemical properties of sediments on reservoir. And then the effect of sediments is evaluated on the water quality in reservoir. In the results of physicochemical analysis, the pollution level of midstream is the highest, which shows the traits that the water is more deeper and takes place a deposition consistently. Then, the pollution level of upstream is higher than downstream's because inflow has influence on the upstream directly. The downstream is located near tidal gate so that the soil particles can be moved easily and are difficult to be deposited due to the distribution of seawater by control of tidal gate. Therefore, the downstream is showed the lowest pollution level than the others. Also, the concentration of SOD(Sediment Oxygen Demand) in the upstream which is influenced on the effect of inflow is highest than the others. When it analyzes under anaerobic and aerobic condition to understand the release characteristic of sediment, it shows that the release rate is low or negative under the aerobic condition. Whereas the release rate is usually positive under the unaerobic condition relatively. According to these results, it is necessary to maintain the proper environmental factors of water body for decreasing the release rate of sediment. Because the release rate is changeable under the different condition of water body. Therefore, proper strategies are required for increasing the self-purification of water as well as keeping the aerobic condition of sediment and managing a sediment layer directly to control the inner-pollution by the sediment of reservoir.

계절예측 정보 기반 APEX-Paddy 모형 적용성 평가 (Evaluation of Applicability of APEX-Paddy Model based on Seasonal Forecast)

  • 조재필;최순군;황세운;박지훈
    • 농촌계획
    • /
    • 제24권4호
    • /
    • pp.99-119
    • /
    • 2018
  • Unit load factor, which is used for the quantification of non-point pollution in watersheds, has the limitation that it does not reflect spatial characteristics of soil, topography and temporal change due to the interannual or seasonal variability of precipitation. Therefore, we developed the method to estimate a watershed-scale non-point pollutant load using seasonal forecast data that forecast changes of precipitation up to 6 months from present time for watershed-scale water quality management. To establish a preemptive countermeasure against non-point pollution sources, it is possible to consider the unstructured management plan which is possible over several months timescale. Notably, it is possible to apply various management methods such as control of sowing and irrigation timing, control of irrigation through water management, and control of fertilizer through fertilization management. In this study, APEX-Paddy model, which can consider the farming method in field scale, was applied to evaluate the applicability of seasonal forecast data. It was confirmed that the rainfall amount during the growing season is an essential factor in the non-point pollution pollutant load. The APEX-Paddy model for quantifying non-point pollution according to various farming methods in paddy fields simulated similarly the annual variation tendency of TN and TP pollutant loads in rice paddies but showed a tendency to underestimate load quantitatively.

Insights into the Gut Microbiota of Freshwater Shrimp and Its Associations with the Surrounding Microbiota and Environmental Factors

  • Zhao, Yanting;Duan, Cuilan;Zhang, Xu-xiang;Chen, Huangen;Ren, Hongqiang;Yin, Ying;Ye, Lin
    • Journal of Microbiology and Biotechnology
    • /
    • 제28권6호
    • /
    • pp.946-956
    • /
    • 2018
  • The gut microbiota of aquatic animals plays a crucial role in host health through nutrient acquisition and outcompetition of pathogens. In this study, on the basis of the high-throughput sequencing of 16S rRNA gene amplicons, we examined the bacterial communities in the gut of freshwater shrimp (Macrobrachium nipponense) and in their living environments (sediment and pond water) and analyzed the effects of abiotic and biotic factors on the shrimp gut bacterial communities. High bacterial heterogeneity was observed in the freshwater shrimp gut samples, and the result indicated that both the surrounding bacterial community and water quality factors (particularly dissolved oxygen and temperature) could affect the shrimp gut bacterial community. Despite the observed heterogeneity, 57 genera, constituting 38-99% of the total genera in each of the 40 shrimp gut samples, were identified as the main bacterial population in the gut of M. nipponense. In addition, a high diversity and abundance of lactic acid bacteria (26 genera), which could play significant roles in the digestion process in shrimp, were observed in the shrimp gut samples. Overall, this study provides insights into the gut bacterial communities of freshwater shrimp and basic information for shrimp farming regarding the application of probiotics and disease prevention.

영산강수계 비점오염원 중점관리지역 선정에 관한 연구 (A Study on the Selection of Non-point Pollution Management Regions with High Priority Order in the Yeongsan River Basin)

  • 이재춘;박혜린;임병진;이창희;이수웅;이용운
    • 생태와환경
    • /
    • 제45권4호
    • /
    • pp.347-355
    • /
    • 2012
  • In this study, non-point pollution sources in the Yeongsan river basin are analyzed; then, the priority regions (areas divided on a small scale) of management are selected for efficient water management of the Seungcheon and Jooksan reservoirs, which were constructed as one of the 4 major rivers restoration projects. The priority regions are decided by using the criteria of the excessive rate of target water quality, non-point pollution load per unit area, total TP load and down flow distance. The results of this study are as follows. The upper 10% of the priority regions for non-point pollution management includes YB15, YB05, YB10, YB24, YB14 and YB11 for the Seungcheon reservoir watershed, and YC24, YC25, YC30, YC34, YC22 and YC17 for the Jooksan reservoir watershed. However, a few regions in each of the Seungcheon and Jooksan reservoirs need to be selected in higher order, and the non-point pollution removal facilities in the regions need to be installed with respect to budget, urgent matter, and so on.

새만금 유역에서 논 최적관리기법의 수질개선 효과와 정책고려사항 (Effect of Paddy BMPs on Water Quality and Policy Consideration in Saemangeum Watershed)

  • 김종건;이수인;신재영;임정하;나영광;주소희;신민환;최중대
    • 한국습지학회지
    • /
    • 제20권4호
    • /
    • pp.304-313
    • /
    • 2018
  • 새만금 간척지의 농지 간척 사업은 대부분 2020 년까지 완공 될 예정이며, 그 시기 토지의 관개용수 활용에 대한 대비가 필요한 실정이다. 그러나 관개수의 수질은 드물게 목표 농도를 충족하고 있다. 이에 본 연구에서는 논에서의 최적관리기법(BMPs)인 토양검정시비(SO#1), SO#1과 SO#3의 복합처리(SO#2), 배수물꼬(SO#3), 완효성 비료시비 (SO#4) 방법을 관행재배(CT: Control)와 비교하여 논 비점오염원 저감효과 및 정책개발 시의 고려사항을 기술하였다. 논에서의 유출 저감은 SO#3(25%)와 SO#1(27%)에서 관행재배와 비교하였을 때 상대적으로 높았으나, SO#4(9%)와 SO#2(7%)에서 낮게 나타났다. 논 유출량의 NPS 오염물질 농도와 부하는 변화의 폭이 높게 나타났으며 BMPs 중에 유의한 차이는 나타나지 않았다. 또한 농민들의 인식조사 결과, 농민들은 실제 BMP 구현의 한계로 기존 관행적인 영농활동을 유지하고 있는 것으로 나타났다. 따라서 NPS 오염물질 관리와 관개수 절약을 위해서 농민 교육 및 지원과 함께 관개물꼬 및 논의 담수심을 자동 조절할 수 있는 관리방안이 필요할 것으로 판단된다.