A Study for the Selection Method of Control Area of Nonpoint Pollution Source

비점오염원 관리지역의 선정 기법에 관한 연구

  • Park, Sanghyun (Chungcheongnamdo Watershed Management Research Center) ;
  • Jeong, Woohyeok (Chungcheongnamdo Watershed Management Research Center) ;
  • Yi, Sangjin (Chungcheongnamdo Watershed Management Research Center) ;
  • Lim, Bongsu (Department of Environmental Engineering, Daejeon University)
  • 박상현 (충남발전연구원 수질총량관리센터) ;
  • 정우혁 (충남발전연구원 수질총량관리센터) ;
  • 이상진 (충남발전연구원 수질총량관리센터) ;
  • 임봉수 (대전대학교 환경공학과)
  • Received : 2010.04.06
  • Accepted : 2010.07.30
  • Published : 2010.09.30

Abstract

This study introduces a model of territorial analysis on Chungcheongnam-do Nonsan-chun valley area, which gives an example of a method of selecting the management area for non-point pollution source from land use to help eliminate its source. High discharge load per unit area signify high level of land ratio with high level of basic unit of development load (including factory sites, school sites, roadways), which mean that there are a significant level of urbanization. It is these areas with the examination of the water quality of the nearby river that should be considered as the management area for non-point pollution source. Thus, the management area for non-point pollution source should be sought in areas with high discharge load per unit area and high density of water pollution area. When level of drainage is high the pollution density level is relatively lower, and when the level of drainage is low the density level is relatively higher. The level of pollution from non-point pollution source is much lower with more water flowing through. The possible non-point pollution source areas that were selected with these standards were then examined with the distance from the river, the slope angle, land usage, elevation, BOD discharge density load, T-N discharge density load, T-P discharge density load, and were given a level one through five. Out of the possible areas Nonsan-si Yeonmu-eup Anshim-li was the densest area, and it was given level one. The level one area should be examined further with the field analysis to be selected as the actual management area for non-point pollution source.

Keywords

References

  1. 강용태, 한상용, 전종규, 양희천, 송근관, 조용현(2007). 도시하천유역내의 비점오염원 발생특성에 관한 연구. 공동춘계학술발표회 논문집, 한국물환경학회.대한상하수도학회, pp. 826-834.
  2. 국립환경과학원(2008). 제 2단계 수계요염총량관리기술지침.
  3. 박상현(2010). 비점요염원 관리지역의 선정기법에 관한 연구. 석사학위논문, 대전대학교.
  4. 이상진, 김건하, 이상득, 정우혁(2009). 충청남도 비점오염저감시설의 운영실태 및 관리방안 - 유기물질($BOD_{5}$)을 중심으로. 충남발전연구원.
  5. 이영수(2008). 비점오염원처리시설의 적지분석방법-진잠천 유역을 중심으로. 석사학위논문, 한밭대학교.
  6. 최지용, 신창민(2002). 비점오염원 유출저감을 위한 우수 유출수관리방안, 한국환경정책 평가연구원.
  7. 환경부(2002). 토지피복지도 제작지침안.
  8. 환경부(2005). 주요 비점오염원에 대한 효과적인 관리방안.
  9. 환경부(2008). 수질 및 수생태계 보전에 관한 법률[법률 제 8976호].
  10. 환경부(2009). 수질 오염공정시험법.
  11. 환경부 물환경정보시스템(2009). 수질측정망, http://water.nier.go.kr/potal/weis/all.htm/.