• Title/Summary/Keyword: water phantom

Search Result 371, Processing Time 0.028 seconds

Evaluation of Renal Uptake Rate in 99mTc-DMSA Scan on Pediatrics (소아 99mTc-DMSA 검사에서 신장 섭취율의 평가)

  • Baek, Seungju;Lee, Hyoyeong;Gil, Sanghyeong;Jo, Kyoungnam
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.235-238
    • /
    • 2015
  • The aims of this study were to evaluate the difference of renal uptake rate in $^{99m}Tc-DMSA$ scan on pediatrics by including the bladder. Phantom and Clinical studies were performed. In the phantom study, we put $^{99m}TcO_4{^-}$ (300uCi, 11 MBq) in 3cups filled with distilled water at the rate 1:1:0, 1:1:0.5, 1:1:1, 1:1:2 and were placed Lt kidney, Rt kidney and bladder position on the table. To acquire the image, we used Symbia-E gamma camera from Siemens with preset count method(400,000 counts). In quantitative analysis, the counts of drawing ROIs on the phantom were analyzed. In clinical studies, we analyzed the 20 pediatrics who were examined by $^{99m}Tc-DMSA$ scan. At first, the images were acquired with both kidney and bladder. Secondly we acquired images after shielding the bladder. And the data were compared using a pared t-test by SPSS(ver.22.0). As a result of renal phantom's experiment, we compared with average of uptake rate(%), 1:1:0 was Lt 43.32%, Rt 45.97%, 1:1:0.5 was Lt 35.79%, Rt 36.89%, 1:1:1 was Lt 29.68%, Rt 31.45% and 1:1:2 was Lt 22.89%, Rt 24.32%. There was no correlation between the zoom and uptake rate. The results of patient were that excluded bladder was $29.83{\pm}8.81%$(Lt), $24.29{\pm}6.66%$(Rt) and included bladder was $26.65{\pm}8.03%$(Lt, $21.78{\pm}6.24%$(Rt). This is deemed statistically significant (p<0.05). Renal uptake rate was undervalued because the counts of bladder were included in the total counts.

Determination of Phantom Scatter Factors for Small Photon Fields (소조사면 광자선의 팬톰산란인수 결정)

  • Oh, Young-Kee;Choi, Tae-Jin;Kim, Jin-Hee;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.106-111
    • /
    • 2009
  • Total scatter factor ($S_{cp}$), head scatter factor ($S_c$) and phantom scatter factor ($S_p$) are very important for accurate radiation therapy at stereotactic radiosurgery (SRS) with irregular field shape using micro-MLC and intensity modulated radiation therapy (IMRT) including many small field sizes. In this study we measured and compared $S_{cp}$ with reference ion chamber, pinpoint chamber and diode detector and adapted the resuls form diode detector. Head scatter factors for small field sizes were also measured with diode detector covered 1.5 cm-thick solid water build-up cap. Some errors like as electron contamination of 1~3% were included in the values of Sc but trend of total results of $S_c$ was coincided with basic theory. Phantom scatter factors for small field sizes were calculated form $S_{cp}$ and $S_c$. The results of $S_p$ were compared and were well-agreed with those of other authors.

  • PDF

Study on the Characteristics of Response Correction Factor of Ionization Chamber in RW3 Solid Phantom for High Energy X-rays (RW3 고체팬텀에서 고에너지 X-선에 대한 전리함 반응보정인자의 특성에 관한 연구)

  • Lee, Jeong-Ok;Jeong, Dong-Hyeok;Kim, Bu-Gil
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.205-212
    • /
    • 2009
  • The response correction factor ( h) is a factor to convert the response of the chamber in solid phantom to the response in water. In RW3 solid phantom, the dependency of beam quality and depth for high energy X-rays are known characteristics, however the dependency of field size, SSD, and chamber type are unknown. In this work we have studied the unknown characteristics on the dependency of response correction factor. The farmer type chamber (FC65G) and small chamber (CC13) were used and two beam qualities of 6 and 15 MV were evaluated. The measured response correction factors at the depth of 5 cm and 10 cm were h = 1.015 and 1.021 for 6 MV X-rays, and h = 1.024 and 1.029 for 15 MV X-rays. In conclusion the response correction factor did not depend on the field size and SSD while depending on the beam quality and depth. In the chambers, there are small differences between the two chambers used in this study but we think additional study for more chambers should be required. The results in this study can be used for analyzing the measured values from ionization chamber dosimetry in RW3.

  • PDF

A Preliminary Study on Measuring Void Fraction in a Fuel Rod Assembly by using an X-ray Imaging System (X선 영상 장치를 이용한 핵연료 집합체 내 기포율 측정을 위한 선행 연구)

  • Lee, Sun-Young;Oh, Oh-Sung;Lee, Se-Ho;Lee, Seung-Wook
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.571-578
    • /
    • 2017
  • Bubbles are generated by the boiling of the cooling water when an accident occurs in the reactor and then in order to measure the void fraction, the Optical Fiber Probe(OFP) and optical camera are used in thermal hydraulic safety research. However, such an optical method is not suitable for measuring the void fraction in a $17{\times}17$ array of fuel rods due to the geometrical limitations. This study was conducted as a preliminary study using x-ray system and various phantoms before applying to rod bundles. Through radiographic and tomographic experiments, the tube voltage of the x-ray generator was 130 kVp and the tube current was 1 mA. In addition, it is possible to measure the hole of 1mm in size visually through the bubble resolution phantom, and it is confirmed that the contrast is relatively decreased in the inside of the freon in the case of the contrast evaluation using the road phantom. However, we could obtain good image without distortion when reconstructing the image. Bubble generation phantom experiments were used to confirm the flow direction of the bubbles and to acquire tomography images. The image J tool was used to measure the void fraction of 18 % for a single tomography image. This study has carried out previous researches for the measurement of the bubble rate around the nuclear fuel and could be used as a basic research for continuous research.

Patient-Specific Quality Assurance in a Multileaf Collimator-Based CyberKnife System Using the Planar Ion Chamber Array

  • Yoon, Jeongmin;Lee, Eungman;Park, Kwangwoo;Kim, Jin Sung;Kim, Yong Bae;Lee, Ho
    • Progress in Medical Physics
    • /
    • v.29 no.2
    • /
    • pp.59-65
    • /
    • 2018
  • This paper describes the clinical use of the dose verification of multileaf collimator (MLC)-based CyberKnife plans by combining the Octavius 1000SRS detector and water-equivalent RW3 slab phantom. The slab phantom consists of 14 plates, each with a thickness of 10 mm. One plate was modified to support tracking by inserting 14 custom-made fiducials on surface holes positioned at the outer region of $10{\times}10cm^2$. The fiducial-inserted plate was placed on the 1000SRS detector and three plates were additionally stacked up to build the reference depth. Below the detector, 10 plates were placed to avoid longer delivery times caused by proximity detection program alerts. The cross-calibration factor prior to phantom delivery was obtained by performing with 200 monitor units (MU) on the field size of $95{\times}92.5mm^2$. After irradiation, the measured dose distribution of the coronal plane was compared with the dose distribution calculated by the MultiPlan treatment planning system. The results were assessed by comparing the absolute dose at the center point of 1000SRS and the 3-D Gamma (${\gamma}$) index using 220 patient-specific quality assurance (QA). The discrepancy between measured and calculated doses at the center point of 1000SRS detector ranged from -3.9% to 8.2%. In the dosimetric comparison using 3-D ${\gamma}$-function (3%/3 mm criteria), the mean passing rates with ${\gamma}$-parameter ${\leq}1$ were $97.4%{\pm}2.4%$. The combination of the 1000SRS detector and RW3 slab phantom can be utilized for dosimetry validation of patient-specific QA in the CyberKnife MLC system, which made it possible to measure absolute dose distributions regardless of tracking mode.

A study on the dose distribution for total-body & hemibody irradiation using clinical photon beams (광자선을 이용한 전신 및 반신조사의 선량분포에 관한 고찰)

  • 김진기;권형철;김정수;오영기;김기환;신교철;김정홍;박충기;정동혁
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.147-153
    • /
    • 2001
  • We have discussed that the total body irradiation(TBI) dose distribution of 6 and 10 MV photon beams, also differences between calculation dose use of compensator sheet and measurements in humanoid phantom. Total body irradiation and hemi-body irradiation(HBI) can be effectively performed when uniformity of dose distribution is estabilished. The method of TBI and HBI dosimatry requires special considerations related to technique, long distance and very large field, machine parameter, patient positioning. TBI and HBI with megavoltage photon beams requires basic dosimatric data which have to be measured directly or derived from the standard beam data. The semiconductor detector and ion chamber were positioned at a dmax depth, mid depth, and its specific ratio was determined using a scanning data by RFA-7 3-dimensional water phantom and solid phantom. The effective source axis distance 380 cm, the field size from 120 cm to 152 cm, isodose distributions were analyzed as a function of the thickness in phantom. Also, have discussed that the measurement of basic data for clinical photon beams for dosage calculations, data calculation sheet and the use of tissue compensation to improve dose uniformity. We have improved a dose uniformity in the TBI and HBI method.

  • PDF

Dose Distribution in Solid Phantom by TLD with a Metal Plate of Various Thicknesses (다양한 두께의 금속판을 얹은 TLD를 이용하여 구한, 고체 팬텀 내에서의 선량분포)

  • Kim, Sookil
    • Progress in Medical Physics
    • /
    • v.10 no.2
    • /
    • pp.83-88
    • /
    • 1999
  • Purpose: TLD experiments were set up to measure the dose distribution and to analyze the influence on dose measurement of thin metal plate and solid water phantom. The aim of the present study was to investigate the build-up effect of metal plate loaded on TLD chip and depth dose in the controlled environment of phantom measurements. Materials and Methods: Measurements were done by using LiF TLD-100 loaded by a thin metal plate with the same surface area (3.2$\times$3.2 $\textrm{mm}^2$) as TLD chip. TLD chips loaded with one metal plate from three different metal plate (Tin, Copper, Gold) of different thicknesses (0.1, 0.15, 0.2, 0.3 mm) were used respectively to measure radiation dose. Using the TLD loaded with one metal plate, surface dose and the depth dose at the build-up maximum region were investigated. Results: Using a metal plate on TLD chip increased the surface dose. Surface dose curve shows the dose build-up against equivalent thickness of metal to water. The values of TL reading obtained by using metal plate at depth of build-up maximum are about 8% to 13% lower than those obtained by normal TLD chip. Conclusion: The metal technique used for TLD dosimetry could provide clinicals information about the build-up of dose up to 4.2mm depth in addition to a depth dose distribution. The results of TLD with a metal plate measurements may help with decisions to boost or bolus certain areas of the skin.

  • PDF

The Effects of the CT Voltages on the Dose Calculated by a Commercial RTP System (CT 관전압이 상용 전산화치료계획장치의 선량계산에 미치는 영향)

  • 강세권;조병철;박희철;배훈식
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.23-29
    • /
    • 2004
  • The relationship between the dose calculated with a radiotherapy treatment planning system (RTPS) and CT number verses the relative electron density curve was investigated for various CT voltages and beam qualifies. We obtained the relationship between the CT numbers and electron densities of the tissue equivalent materials for various CT voltages and beam qualifies. At lower CT voltages, the higher density materials, like cortical bone, showed larger CT numbers and the soft tissues showed no variations. We peformed a phantom study in a RTPS, where a phantom consisted of lung and bone legions in water. We calculated the dose received behind the lung and bone regions for 6 MV photon beams, in which the regions below the lung, water and bone received higher doses in this listed order. The result was the same for 10 MV photon beams. For the clinical application, the doses were calculated for the lung and pelvis. No difference was observed when using different electron density conversion tables with various CT voltages from a same CT. A relative dose difference of 1.5% was obtained when the CT machine for the density conversion table was different from that for the CT image for planning.

  • PDF

Characterization of Radiation Field in the Steam Generator Water Chambers and Effective Doses to the Workers (증기발생기 수실의 방사선장 특성 및 작업자 유효선량의 평가)

  • Lee, Choon-Sik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.4
    • /
    • pp.215-223
    • /
    • 1999
  • Characteristics of radiation field in the steam generator(S/G) water chamber of a PWR were investigated and the anticipated effective dose rates to the worker in the S/G chamber were evaluated by Monte Carlo simulation. The results of crud analysis in the S/G of the Kori nuclear power plant unit 1 were adopted for the source term. The MCNP4A code was used with the MIRD type anthropomorphic sex-specific mathematical phantoms for the calculation of effective doses. The radiation field intensity is dominated by downward rays, from the U-tube region, having approximate cosine distribution with respect to the polar angle. The effective dose rates to adults of nominal body size and of small body size(The phantom for a 15 year-old person was applied for this purpose) appeared to be 36.22 and 37.06 $mSvh^{-1}$) respectively, which implies that the body size effect is negligible. Meanwhile, the equivalent dose rates at three representative positions corresponding to head, chest and lower abdomen of the phantom, calculated using the estimated exposure rates, the energy spectrum and the conversion coefficients given in ICRU47, were 118, 71 and 57 $mSvh^{-1}$, respectively. This implies that the deep dose equivalent or the effective dose obtained from the personal dosimeter reading would be the over-estimate the effective dose by about two times. This justifies, with possible under- or over- response of the dosimeters to radiation of slant incidence, necessity of very careful planning and interpretation for the dosimetry of workers exposed to a non-regular radiation field of high intensity.

  • PDF

Algorithm for the design of a Virtual Compensator Using the Multileaf Collimator and 3D RTP System (다엽콜리메터와 삼차원 방사선치료계획장치를 이용한 가상 선량보상체 설계 알고리듬)

  • 송주영;이병용;최태진
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.185-191
    • /
    • 2001
  • The virtual compensator which are realized using a multileaf collimator(MLC) and three-dimensional radiation therapy Planning(3D RTP) system was designed. And the feasibility study of the virtual compensator was done to verify that it can do the function of the conventional compensator properly. As a model for the design of compensator, styrofoam phantom and mini water phantom were prepared to simulate the missing tissue area and the calculated dose distribution was produced through the 3D RTP system. The fluence maps which are basic materials for the design of virtual compensator were produced based on the dose distribution and the MLC leaf sequence file was made for the realization of the produced fluence map. Ma's algorithm were applied to design the MLC leaf sequence and all the design tools were programmed with IDL5.4. To verify the feasibility of the designed virtual compensator, the results of irradiation with or without a virtual compensator were analyzed by comparing the irradiated films inserted into the mini water phantom. The higher dose area produced due to the missing tissue was removed and intended regular dose distribution was achieved when the virtual compensator was applied.

  • PDF