References
- Blomgren H, Lax I, Naslund I, Svanstrom R. Stereotactic high dose fraction radiation therapy of extracranial tumors using an accelerator. Clinical experience of the first thirty-one patients. Acta Oncol. 1995;34(6):861-70. https://doi.org/10.3109/02841869509127197
-
Yoon J, Park K, Kim JS, Kim YB, Lee H. Acceptance Testing and Commissioning of Robotic Intensity-Modulated Radiation Therapy M6 System Equipped with
$InCise^{TM}$ 2 Multileaf Collimator. Prog Med Phys. 2018;29(1):8-15. https://doi.org/10.14316/pmp.2018.29.1.8 - Murai T, Hattori Y, Sugie C, Iwata H, Iwabuchi M, Shibamoto Y. Comparison of multileaf collimator and conventional circular collimator systems in Cyberknife stereotactic radiotherapy. J Radiat Res. 2017;58(5):693-700. https://doi.org/10.1093/jrr/rrw130
- Mcguinness CM, Gottschalk AR, Lessard E, et al. Investigating the clinical advantages of a robotic linac equipped with a multileaf collimator in the treatment of brain and prostate cancer patients. J Appl Clin Med Phys. 2015;16(5):284-95. https://doi.org/10.1120/jacmp.v16i5.5502
- Dieterich S, Cavedon C, Chuang CF, et al. Report of AAPM TG 135: quality assurance for robotic radiosurgery. Med Phys. 2011;38(6):2914-36. https://doi.org/10.1118/1.3579139
- Chong NS, Lee JJS, Kung WH, et al. Patient delivery quality assurance for linac-based IMRT and helical tomotherapy using solid state detectors. Radiat Meas. 2011;46(12):1993-95. https://doi.org/10.1016/j.radmeas.2011.08.004
- Markovic M, Stathakis S, Mavroidis P, Jurkovic IA, Papanikolaou N. Characterization of a two-dimensional liquidfilled ion chamber detector array used for verification of the treatments in radiotherapy. Med Phys. 2014;41(5).
- Seppenwoolde Y, Berbeco RI, Nishioka S, Shirato H, Heijmen B. Accuracy of tumor motion compensation algorithm from a robotic respiratory tracking system: A simulation study. Med Phys. 2007;34(7):2774-84. https://doi.org/10.1118/1.2739811
- Pepin EW, Wu H, Zhang Y, Lord B. Correlation and prediction uncertainties in the cyberknife synchrony respiratory tracking system. Med Phys. 2011;38(7):4036-44. https://doi.org/10.1118/1.3596527
- Ezzell GA, Burmeister JW, Dogan N, et al. IMRT commissioning: multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119. Med Phys. 2009;36(11):5359-73. https://doi.org/10.1118/1.3238104
- Blanck O, Masi L, Damme MC, et al. Film-based delivery quality assurance for robotic radiosurgery: Commissioning and validation. Phys Med. 2015;31(5):476-83. https://doi.org/10.1016/j.ejmp.2015.05.001
- Lin MH, Veltchev I, Koren S, Ma C, Li J. Robotic radiosurgery system patient-specific QA for extracranial treatments using the planar ion chamber array and the cylindrical diode array. J Appl Clin Med Phys. 2015;16(4):290-305. https://doi.org/10.1120/jacmp.v16i4.5486
- Kim J, Park K, Yoon J, et al. Feasibility Study of a Custommade Film for End-to-End Quality Assurance Test of Robotic Intensity Modulated Radiation Therapy System. Prog Med Phys. 2016;27(4):189-95. https://doi.org/10.14316/pmp.2016.27.4.189
Cited by
- Skin Dose Comparison of CyberKnife and Helical Tomotherapy for Head-and-Neck Stereotactic Body Radiotherapy vol.30, pp.1, 2019, https://doi.org/10.14316/pmp.2019.30.1.1
- Development of an x-ray-opaque-marker system for quantitative phantom positioning in patient-specific quality assurance vol.91, pp.None, 2018, https://doi.org/10.1016/j.ejmp.2021.10.017