• Title/Summary/Keyword: water gate

검색결과 419건 처리시간 0.028초

휴대용제어단말기를 이용한 원격조정수문개발 (Remote Operation Water-gate Development using Portable Control Terminal)

  • 성백섭;박창언;김일수;차용훈;이진구
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 춘계학술대회 논문집
    • /
    • pp.515-520
    • /
    • 2002
  • This paper begin a new approach in the water-gate controller using radio communication. The dissertation is on the controllable device development of water-gate in the remote distance from water-gate trough the transceiver by radio communication. The proposed water-gate control device is simple in structure, an suitable for implementation of water-gate control in the remote distance. The remote controller water-gate device inspected the up and down motion of water-gate through the LCD displayer, so that it was very safety driving about the surroundings information, over loading and position of water-gate, and so on.

  • PDF

무선통신을 이용한 수문제어장치 개발에 관한 연구 (A Study on the Worter-gate Control Device Development using Radio Communication)

  • 이진구;김인주;정영재;손준식;성백섭;김일수;박창언
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.612-615
    • /
    • 2002
  • This paper begin a new approach in the water-gate control using radio communication. The dissertation is on the controllable device development of water-gate in the remote distance from water-gate trough the transceiver by radio communication. The proposed water-gate control device is simpe in structure, an suitable for implementation of water-gate control in the remote distance. The remote controller water-gate device inspected the up and down motion of water-gate through the LCD displayer, so that it was very safety driving about the surroundings imformation, over loading and position of water-gate, and so on.

  • PDF

취수문비의 안정성에 관한 연구 (A Study on the Stability of Intake gate in a Dam)

  • 곽영균;고성호;강민구
    • 한국유체기계학회 논문집
    • /
    • 제11권1호
    • /
    • pp.46-51
    • /
    • 2008
  • A stability analysis has been made for a newly designed gate of intake tower of reservoir. The analysis is composed of finding the natural frequency of the gate and the frequency induced by water flowing over and through the gate. ANSYS is employed to calculate the natural frequency of the gate and SC/Tetra is utilized for calculating flow field around the gate, which in turn gives the frequency of pressure force fluctuation on the gate. In addition to the safety analysis, the present study presents how the gate selectively intakes a muddy water layer located in the middle depth of reservoir.

친환경성을 고려한 무동력 자동수문 개발 (Development of Eco-Friendly Self-Controlled Gate)

  • 정광근;이광야;김해도
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.546-551
    • /
    • 2006
  • It considered the population decrease and becoming older in age of the Rural area and operates by unmaned-non power which self-controlled gate developed. The operational principal used a buoyancy and when water level in the canal arrived to the set water level, in order for gate to be opened. The plate in order to fix to the shape in the canal which begs, it did in the quadrilateral and the rainfall it is sour intensively, canal bank comfort plate in order to ascend completely, it designed. The result which establishes Self-controlled gate, the gate upstream 1km until degree there was water level synergistic effect. It developed 4 as the research project and it established in Ah San city, and it establishes the Self-controlled gate of $B3.2m{\times}H2.4m$ size in Damyang and 100ha it does water supply in the rice field.

  • PDF

수문을 위한 원격제어장치 개발에 관한 연구 (A Study on Development of Remote Control Device for the Water Gate)

  • 이진구;김인주;정영재;손준식;김일수;박창언;성백섭
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1668-1671
    • /
    • 2003
  • Today, remote monitoring and control systems are becoming the cost-effetive management tools for almost all water user groups, including irrigators, water districts, municipal water suppliers, and wildlife management groups. This paper represents a new approach in the water-gate control using radio communication. The proposed device is simple in structure and suitable for implementation of water-gate control through the transceiver by radio communication. It was confirmed that the developed device was very efficient to control water-gate and to prove the up and down motion of water-gate through the LCD displayer

  • PDF

무선데이터 통신(2.4GHz대)을 이용한 수문 원격제어장치 개발에 관한 연구 (A Study on Development of Remote Control System for Watergate by Used Wireless Transfer Method)

  • 이진구;김일수;박창언
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 추계학술대회
    • /
    • pp.237-241
    • /
    • 2003
  • The world's supply of water in all forms is enormous. However, only a tiny fraction of the planet's supply is available to us as fresh water, and that is distributed very unevenly. About 97% of oater volume is found in the oceans and is too salty for drinking, growing crops, and most industrial uses except cooling. In addition water supply crises in already-water-short-regions will intensify because population and industrialization increase. Today, remote monitoring and control systems are becoming the cost-effective management tools for almost all water user groups, including irrigators, water districts, municipal water suppliers, and wildlife management groups. This paper represents a new approach in the water-gate control using radio communication. The proposed device is simple in structure and suitable for implementation of water-gate control through the transceiver by radio communication. It was confirmed that the developed device was very efficient to control level of water-gate and to prove the up and down motion of water-gate through the LCD displayer.

  • PDF

표층수의 월류를 통한 소수력빌전소 수차터빈측의 유동안정화 연구 (Studies on the flow stabilization around the turbine suction with utilizing the surface water overflow at small-hydraulic power plant)

  • 이성명;김철환;유근종;김원석
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.165.2-165.2
    • /
    • 2011
  • Flow with suction to water turbine must be in stable state at small hydraulic power plant. But because of water level fluctuation and water gate effect according to irregular supply of cooling water, it would happen to produce bubble and vortex and finally lead to problems in power-plant system. With utilizing the concept design of double size gate, surface water overflowed the overhead of gate for stable flow at suction. We developed the overflow condition and analyzed the design factor with existed one such as water level(overflow amount) and overhead of water gate(overflow figure). Flow test and CFD simulation say that flow have stable state around suction and 20% of wave reduction effect at surface layer after surface water overflow.

  • PDF

배수갑문 테인터 게이트(Tainter Gate)의 진동현상에 관한 모형실험(Ⅱ)- 문비 안에서 밖으로의 흐름 - (Model Tests Study on Flow-induced Vibrationof Tainter Gate in Estuary Sulices(Ⅱ)- Flow from the Gate Inside to the Gate Outside -)

  • 이성행;우상익
    • 한국농공학회논문집
    • /
    • 제46권2호
    • /
    • pp.41-47
    • /
    • 2004
  • A model test is carried out to investigate flow-induced vibration of a Tainter gate in estuary sulices. The gate model scaled with the ratio of 1:25 is made of acryl panel dimensioned 0.66 m in width, 0.5 m in height in the concrete test flume. Firstly, natural frequencies of the model gate are measured and the results are compared with the numerical results in order to verify the model. In the flow from the gate inside to the gate outside, the amplitudes of the vibration are measured under the different gate opening and downstream water level conditions. Also revised gate models with 20 mm bottom width are tested under the different gate openings and water levels. The results are analyzed to study the characteristics of the Tainter gate vibration in the sea ward flow. These test results are assessed in comparison with the results in the lake ward flow, as a result, presents the dynamic characteristics of the Tainter gate and a basic data for the guide manuals of gate management.

배수갑문 방류시점 및 방류량에 따른 담수호의 수질변화 (Water Quality Behavior by the Sluice Gate Operation of Freshwater Lake)

  • 김선주;김성준;김필식;이창형
    • 한국농공학회지
    • /
    • 제45권1호
    • /
    • pp.91-101
    • /
    • 2003
  • Boryeong Seadike located at southwestern seashore of Korean peninsula completed in 1997. Sluice gate operation can be an important factor to maintain lake water quality and reduce retaining time of pollutants within lake. The lake water quality simulation model, WASPS was adopted and tested to find out proper gate operation timing and discharge amount. From the simulation of sluice gate operation, the results showed that the later the time of discharge for loosing 1 day successively to 6 days, the better the quality of water. Discharge amount showed relatively minor changes of water quality. This means that pollutants flowed into lake from watershed do not have enough time to mix up with deep water when the gate opened at early time. About 3 days delay of discharge caused the dilution effect to stabilize the lake water quality in case of Boryeong freshwater lake.

금강하구둑 배수갑문 조작에 의한 상류수역의 수위변동 (Variation of Water Level on the Upstream Gauging Station by Operation of the Drainage Sluice Gate of Geumgang Estuary Dam)

  • 박승기
    • 한국농공학회논문집
    • /
    • 제47권6호
    • /
    • pp.15-24
    • /
    • 2005
  • The normalization on the characteristics of water level change at the upstream gauging station was attempted according to the operation of drainage sluice gate of the Geumgang estuary dam. The characteristics were normalized by the analysis of water level change and by the linear-regression of the water level data measured at the inner station of Geumgang estuary dam and upstream gauging station. The results of normalization may be referred to the management of Geumgang estuary lake, the operation of pumping and drainage stations in the shore of the lake. The mean response time of water level change on Ibpo, Ganggyeong and Gyuam water level station were 39,81 and 160 minutes, when sluice gate was opened respectively. The mean velocity of surface wave, the mean displacement of water level change, the mean time of water level change and the mean rate of water level change varied largely depending on the location of gauging station and the characteristics of stream section of the water level gauging station.