• 제목/요약/키워드: water distribution system analysis

검색결과 561건 처리시간 0.033초

지리정보체계를 이용한 국부경사의 공간적 변동성 해석 (Analysis of Spatial Variability of Local Slope by Means of Geographic Information System)

  • 김주철;최용준;윤여진
    • 한국환경과학회지
    • /
    • 제21권3호
    • /
    • pp.297-303
    • /
    • 2012
  • Slope is the geographic factor reflecting the 3-dimensional features of basin and it can be considered as the important geomorphological factor which governs the morphology of basin and the dynamics of water movement. In this study the approach to the 3-dimensional structures of basin is attempted with statistical analysis of local slope which can be defined and measured in easy and objective manner by means of DEM. As a result local slope is confirmed to be a highly variable spatial factor in basin. And distribution map of local slope based on spatial autocorrelation length in this study would be a useful tool in the further research of hydrology and geomorphology.

유효유량 개념을 도입한 상수관망 Subsystem 별 중요도 산정 (Evaluation of Subsystem Importance Index considering Effective Supply in Water Distribution Systems)

  • 서민열;유도근;김중훈;전환돈;정건희
    • 한국방재학회 논문집
    • /
    • 제9권6호
    • /
    • pp.133-141
    • /
    • 2009
  • 상수관망의 용수는 수용가가 사용하기에 불편함이 없는 적절한 유량과 압력으로 사용성이 충분히 만족된 상태에서 공급되어야 한다. 상수도 시스템의 수리학적 해석 방법으로 사용되는 Demand Driven Analysis (DDA) 방법은 관망의 수리학적 상태가 변화했을 때 부압이 발생하는 등 비현실적인 결과를 발생시킬 수 있다. Pressure Driven Analysis (PDA) 방법은 비정상상태에서의 압력 및 공급량의 변화를 알기 위하여, 절점수두-용수공급량 관계 (Head-Outflow Relationship, HOR)를 이용하는데, 이는 실측자료의 부족으로 인하여 대부분의 연구에서는 HOR이 가정되어 사용되었다. 본 연구에서는 PDA 분석에서 단점을 가진 HOR 대신, 절점에서 실제 사용성을 만족시키면서 공급이 가능한 용수량인 유효유량을 제안하였다. 그리고 Subsystem이 격리되었을 때 유효유량의 변화를 산정함으로써 격리된 부분의 관망에 대한 영향을 평가하여 이를 Subsystem 중요도 지수(Subsystem Importance Index, SII)로 정의하였다. 이를 위해 최적화 기법 중 하나인 Harmony Search와 상수관망 해석 프로그램인 EPANET을 결합하여 모형을 구축하였다. 제안된 모형을 대규모 상수관망에 적용하였으며, 본 모형은 상수관망의 유지, 보수 시에 관거 혹은 밸브 등의 처리 우선순위 산정 및 상수관망 신뢰도 평가로 활용 가능할 것으로 판단된다. 또한 유효유량산정을 통하여 상수관망이 실제로 사용함에 불편함이 없을 정도로 용수공급이 얼마나 가능한가를 종전에 비하여 보다 정량적으로 산정 가능하다.

1차원수리모형-분포형 연계모형을 이용한 수질오염사고 분석 (Pollution accident analysis using a hybrid hydrologic-hydraulic model(K-River & K-DRUM))

  • 이용현;안현욱;안정민;허영택
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2023년도 학술발표회
    • /
    • pp.472-472
    • /
    • 2023
  • 본 연구에서는 낙동강 수계에서 발생한 수질오염사고에 대해 K-River와 K-DRUM 결합모형을 이용하여 오염물질의 이동을 분석하였다. 국내에서는 수질오염총량제 도입 이후 수질관리에서 물순환과정을 수용한 배분모델의 필요성과 비점오염원의 중요성이 강조되었다. 따라서 비점오염원의 유출특성을 반영하기 위해 유역의 오염도를 분석할 수 있는 K-DRUM 분포모형을 사용하였다. 그리고 낙동강 수계에서 운영되는 댐 운영규칙을 적용하여 모델의 재현성을 높였다. 또한 하천 내 오염물질의 이동을 분석하기 위해 대류-분산 방정식의 대류 부분만을 1차원 수리모델 K-River에 적용하여 오염물질 추적을 수행하였다. 수질오염 분석 결과 오염물질의 최고농도는 과소평가 되었으나 도착시간과 전체 오염물질 농도의 추이는 잘 재현되었다.

  • PDF

대면적 마그네트론 스퍼터링 증착장비의 수냉시스템 방열성능 해석 (Cooling Performance Analysis of Water-Cooled Large Area Magnetron Sputtering System)

  • 김경진
    • 반도체디스플레이기술학회지
    • /
    • 제9권2호
    • /
    • pp.111-116
    • /
    • 2010
  • In a large area magnetron sputtering system, which is under the influence of high heat load from the plasma, it is necessary to use the effective water cooling in order to maintain the proper deposition performance and the economic use of target materials. A series of three-dimensional numerical simulations are carried out on the simplified model of the large area magnetron sputtering system with the cooling plate that includes the U-shaped water channel. The analysis is focused on the effects of water channel geometry, cooling water flowrate, thermal conductivity of target material, and the degree of target erosion on the cooling performance of cooling plate, which is represented by the temperature distribution of target material.

상수도관망에서 입자성 물질의 특성분석 및 영향조사 (Characteristic Analysis and Effect of Particulate Material in Drinking Water Distribution Networks)

  • 김도환;이두진;황진수;최두용
    • 대한환경공학회지
    • /
    • 제35권5호
    • /
    • pp.312-320
    • /
    • 2013
  • 상수도관망에서의 입자성 물질들은 대부분 금속관로의 내부부식 및 퇴적물에 의한 영향으로 이를 해결할 수 있는 방법은 제한적이라 할 수 있다. 수중의 입자성 물질들은 입자크기, 화합물 성분 및 성상들이 다르며, 이들 특성은 시설별 종류, 관 상태, 외부적 요인 및 공급과정 등에 의해서 차이가 발생하게 된다. 본 연구에서는 상수도관망의 수질조사를 수행하면서 수중의 입자성 물질들에 대한 조사를 실시하고자 하였으며, 정수를 공급하는 각 계통들의 배수지 및 관말지역을 대상으로 실시하였다. 각 조사지점에서 입자성 물질을 포집하기 위해 $47{\phi}$ 의 유리섬유여지(GF/C)를 이용하여 여과를 수행하였다. 수중의 탁도에 영향을 미치는 물질들이 입자성 부유물질과 무기물질들에 의한 것으로 관말지역으로 갈수록 입자성 물질이 증가하는 것으로 조사되었다. XRD를 이용한 입자성 물질의 화합물 성분분석결과 상수도관망의 관말지역에서 가장 많은 화합물은 Goethite (${\alpha}$-FeOOH), Magnetite ($Fe_3O_4$) 등이고 정수와 각 배수지 유출수에서는 Quartz ($SiO_2$)와 Yeelimite ($Ca_4Al_6O_{12}SO_4$) 등도 있는 것으로 조사되어 각 상수도 시설별 용출되거나 잔존하고 있는 화합물 성분이 다르며, 침적물들에도 차이가 있었다.

상수도 1일 급수량 예측을 위한 ANFIS적용 (Application of ANFIS for Prediction of Daily Water Supply)

  • 이경훈;강일환;문병석
    • 상하수도학회지
    • /
    • 제14권3호
    • /
    • pp.281-290
    • /
    • 2000
  • This study investigates the prediction of daily water supply, which is a necessary for the efficient management of water distribution system. ANFIS, namely artificial intelligence, is a neural network into which fuzzy information is inputted and then processed. In this study, daily water supply was predicted through an application of network-based fuzzy inference system(ANFIS) for daily water supply prediction. This study was investigated methods for predicting water supply based on data about the amount of water which supplied in Kwangju city. For variables choice, four analyses of input data were conducted: correlation analysis, autocorrelation analysis, partial autocorrelation analysis, and cross-correlation analysis. Input variables were (a) the amount of water supply, (b) the mean temperature, and (c) the population of the area supplied with water. Variables were combined in an integrated model. Data of the amount of daily water supply only was modelled and its validity was verified in the case that the meteorological office of weather forecast is not always reliable. Proposed models include accidental cases such as a suspension of water supply. The maximum error rate between the estimation of the model and the actual measurement was 18.46% and the average error was lower than 2.36%. The model is expected to be a real-time estimation of the operational control of water works and water/drain pipes.

  • PDF

복합배수관망에 있어서 선형 및 비선형 해석기법의 적용 (Application of Linear and Nonlinear Analysis Technique on the Complex Water Distributing System)

  • 고수현;최윤영;안승섭
    • 한국농공학회지
    • /
    • 제43권4호
    • /
    • pp.69-78
    • /
    • 2001
  • In this study optimal analysis of pipe network was performed using linear and non linear analysis method for complex real pipe network system of Mungyeong water purification field system which consists of 70 nodes and 86 elements. From the examination result of total flow which is distributed to each pipe, it is found that KYPIPE2 Model supplies less amount than NLAM. It is known that dynamic water level and pressure head of KYPIPE2 Model and NLAM are nearly in accordance with each other from each method of the pipe network analyses, and appeared that both methods of analysis shows high reliable result since the distribution of dynamic water level for every node is the short range of EL. 205.0m~EL. 210.0m besides the pressed dynamic water level. The analysis results of pressure in the methods of pipe network analysis for KYPIPE2 Model and NLAM are similar and it is satisfactory result that the pressure distributions of the tab water design criterion of 5.0kgf/cm$^2$ besides the small part of highland.

  • PDF

지하 유류비축기지 수벽공의 효율에 관한 현장계측 및 수치 해석 연구 (Field Measurements and Numerical Analysis on the Efficiency of Water Curtain Boreholes in Underground Oil Storages)

  • 이경주;이희근
    • 터널과지하공간
    • /
    • 제8권2호
    • /
    • pp.79-86
    • /
    • 1998
  • This study was performed to suggest to suggest suitable design conditions of water curtain system through analysis on pressure down in boreholes by hydraulic tests carried out I construction fields for underground oil storages. The influence by hydraulic conductivities of rock mass around boreholes on pressure down in boreholes was analysed. The relationship between array of boreholes and their pressure down was also analysed. Groundwater flow analysis on crude oil and LPG storages was carried out to evaluate results of field tests and to investigate distribution of hydraulic gradient in rock mass around cavern using finite difference method. As the results, hydraulic tests showed that pressure down in boreholes was inverse proportional to the hydraulic conductivity of surrounding rock mass. The rate of pressure down of boreholes was not influenced by water curtain system more than 20m over cavern and was proportional to installation interval of boreholes. The hydraulic gradient in rock mass around cavern was proportional to distance and interval of boreholes and its value was not satisfactory to oil tightness condition in case of no water curtain system.

  • PDF

공급과정 수질개선을 위한 잔류염소 균등화 효과분석 (Analysing the Effect of Residual Chlorine Equalization for Water Quality Improvement in Water Distribution System)

  • 최태호;이두진;배철호;문지영
    • 상하수도학회지
    • /
    • 제30권5호
    • /
    • pp.587-596
    • /
    • 2016
  • This study attempts to draw factors for an analysis of the operation effect of a rechlorination facility and autodrain equipment for residual chlorine equalization by installing and operating a rechlorination facility and autodrain equipment in P City and analyzing the practical evaluation method and operation effect. For this purpose, this study selected three indicators for an analysis of the effectiveness of residual chlorine equalization and conducted a comparative analysis before and after the implementation of the residual chlorine equalization. As a result of estimation, (1) the reduction of the residual chlorine concentration range from a water treatment plant to the pipe end was 16.0%; (2) the total reduction of chlorination input was 18.0%; and (3) the reduction of the generation of disinfection by-products was 19.5%. In addition, this achieved enough residual chlorine equalization in the supply process and shows that it could successfully achieve the economic feasibility of investment in equipment and the reduction of the generation of disinfection by-products. Like this, it is judged that the three indicators suggested in this study will be used sufficiently as indicators of an analysis of the effectiveness of residual chlorine equalization according to the operations of the rechlorination facility and autodrain equipment.

금강수계의 토지이용 및 수질구배에 따른 돌부착 돌말류의 분포특성 (Distribution of Epilithic Diatom Communities in Relation to Land-Use and Water Quality in the Geum River System, South Korea)

  • 조인환;황순진;김백호;김용재
    • 한국물환경학회지
    • /
    • 제30권3호
    • /
    • pp.283-291
    • /
    • 2014
  • To study the distribution characteristics of diatom communities in relation to the gradient of water quality and land-use, water samples and epilithic diatoms were collected from 90 sites including mainstream and tributaries, in the Geum River System (GRS) during no rainfall, May 2011. Of 239 taxa identified, Achnanthes convergens and Cymbella minuta were dominated over all the sites. Cluster analysis on the GRS divided into three groups. Group 1 (G1) is the mountainous upstream, a relatively good water quality, and mainly consisted of saproxenous species. Group 2 (G2) is the urban sites, polluted (high in electric conductivity, total phosphate and soluble reactive phosphorus), and saproxenous and common species. Group 3 (G3) is the agriculture sites, and polluted (turbidity, total nitrogen, nitrate), and saprophilous species. There were some discrepancies between abiotic and biotic variables in GRS; biologically similar between G1 and G2, but abiotically similar between G2 and G3. These differences may attribute to not only physiological characteristics of diatom cells, but complicate relationships between microhabitat and water quality. Thus, an urgent development of generalized or standardized methods to diminish the differences between epilithic diatom community and environments is advent.