• 제목/요약/키워드: water cooling tube

검색결과 196건 처리시간 0.031초

수냉식변압기 냉각튜브의 부식특성 평가에 관한 연구 (A Study on Evalution of Corrosion Properties in cooling tube of water cooling transformers)

  • 정년호;민병연;박현주
    • Corrosion Science and Technology
    • /
    • 제9권5호
    • /
    • pp.216-222
    • /
    • 2010
  • Most of the thirteen substations in operation in the metropolitan area were installed around the year 2000, and since water cooling methods are used to directly withdraw heat from transformer oils, a stable supply of electric power is required through optimal maintenance of facilities. The water cooling tower installed outdoors, which uses the water supply as sprinkler water, experiences the most problems. Since more than 90% of the cooling water is reused, the dissolved composition in the water becomes concentrated due to long operating hours, and impurities dissolve in the water due to air flowing in from the outside, forming hard scales on the outer surface of the cooling tube, and in extreme cases, reacting with the tube material composition, leading to corrosion. As a result, not only is cooling efficiency lowered, but in extreme cases the cooling tube must be replaced. In this study, the characteristics and composition of the scales formed on the cooling tube were analyzed and corrosion characteristics of material types were identified in order to find an efficient maintenance method for cooling tubes. In addition, the degree of dissolution of various chemicals were investigated during the removal of scales that have been formed.

중수로 기기냉각수 열교환기 내부 유동 해석 (Analysis of Internal Flow for Component Cooling Water Heat Exchanger in CANDU Nuclear Power Plants)

  • 송석윤
    • 한국압력기기공학회 논문집
    • /
    • 제8권2호
    • /
    • pp.33-41
    • /
    • 2012
  • The component cooling water heat exchangers are critical components in a nuclear power plant. As the operation years of the heat exchanger go by, the maintenance costs required for continuous operation also increase. Most heat exchangers have carbon steel shells, tube support plates and flow baffles. The titanium tube is susceptible to flow induced vibration. The damage on carbon steel tube support rod and titanium tube around cooling water entrance area is inevitable. Therefore, analysis of internal flow around the component cooling water entrance and tube channel is a good opportunity to seek for failure prevention practice and maintenance method. The numerical study was carried out by FLUENT code to find out the causes of tube failure and its location.

냉각된 복사천장패널의 열전달 특성에 관한 연구 (A Study on the Heat Transfer Characteristics of the Radiant Chilled Ceiling Panel for Space Cooling)

  • 이태원;황인주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.164-169
    • /
    • 2001
  • There is a chilled ceiling panel which carries out the air conditioning by radiation and convection between the room and cold ceiling panel surface. In order to verify heat transfer characteristics between them in cooling system with radiant chilled ceiling panel, analytical and experimental studies were performed for various design and operating parameters such as tube space and diameter, inlet water temperature, mass flow rate, cooling load, and so on. In this study, we found that the tube space and inlet water temperature were more important elements than the tube diameter and water flow rate for the performance of radiant chilled ceiling panel. The cooling capacity of the radiant chilled ceiling panel had the maximum value of $65W/m^{2}$ because the highest cooling capacity was limited by the condensation on the panel surface. The results of comparison between numerical analysis and experiment showed a resonable agreement qualitatively, especially for low cooling capacity.

  • PDF

베어관을 이용한 30RT급 하이브리드 밀폐형 냉각탑의 성능특성에 관한 실험적 연구 (An Experimental Study on Performance Characteristic of 30RT Closed-Type Hybrid Cooling Tower using Bare Tube)

  • 전철호;이호생;문춘근;김재돌;윤정인
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.1096-1101
    • /
    • 2005
  • In this study, the experiment of thermal performance about closed-type hybrid cooling tower was conducted. A closed type cooling tower is a device similar to a general cooling tower, but with cooling tower replaced by a heat exchanger. The test section for this experiment has the process that the cooling water flows from top part of heat exchanger to bottom side in the inner side of tube, and spray water flows gravitational direction in the outer side of it. Air contacts of tube outer side are counterflow. The heat transfer pipe used in this experiment is a bare type tube having an outside diameter of 15.88mm. In this experiment, heat performances of the cooling tower are calculated such as overall heat transfer coefficient of between the process fluid and air, cooing capacity and pressure drop.

  • PDF

무결정결함영역을 유지하면서 에너지를 절감하는 초크랄스키 실리콘 단결정 성장로 수냉관 최적 설계 (Optimal Water-cooling Tube Design for both Defect Free Process Operation and Energy Minimization in Czochralski Process)

  • 채강호;조나영;조민제;정현준;정재학;성수환;육영진
    • Current Photovoltaic Research
    • /
    • 제6권2호
    • /
    • pp.49-55
    • /
    • 2018
  • Recently solar cell industry needs the optimal design of Czochralski process for low cost high quality silicon mono crystalline ingot. Because market needs both high efficient solar cell and similar cost with multi-crystalline Si ingot. For cost reduction in Czochralski process, first of all energy reduction should be completed because Czochralski process is high energy consumption process. For this purpose we studied optimal water-cooling tube design and simultaneously we also check the quality of ingot with Von mises stress and V(pull speed of ingot)/G(temperature gradient to the crystallization) values. At this research we used $CG-Sim^{(R)}$ S/W package and finally we got improved water-cooling tube design than normally used process in present industry. The optimal water-cooling tube length should be 200mm. The result will be adopted at real industry.

원자력발전소 기기냉각수계통의 판형열교환기 적용성 (Applicability of Plate Heat Exchanger to Plant Cooling Water Systems in Pressure Water Reactor)

  • 임혁순
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.505-510
    • /
    • 2001
  • Advanced Pressurized Reactor 1400(APR1400), which is a standard evolutionary advanced light water reactor(ALWR), has been developed from 1992 as one of long-term Government Project(G-7). The APR-1400 is designed to operate at the rated output of 4000MWt to produce an electric power output of around 1450MWe. Due to the increased electric power, In Nuclear Power plant huge quantities of heat are generated in the thermo-dynamic process used for producing electrical energy. So, There is considerationly additional cooling, Heat transfer area and increased cooling water of Heat Exchanger which take care of the different smaller cooling duties within the nuclear power plant. We review applying to PRE instead of Shell-and-Tube Heat exchanger. In this paper, we describe the major design features of PRE, Comparison between a PHE and a Shell-and-Tube Heat Exchanger, and then Applicability of Plate Heat Exchanger in Nuclear Power Plant Component Cooling water systems.

  • PDF

Effects of Tube Materials and Cooling Media on the Energy Separation in Vortex Tubes

  • Riu, Kap-Jong;Kim, Hyun-Woo;Park, In-Su;Kim, Byung-Ha
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권3호
    • /
    • pp.138-146
    • /
    • 2002
  • The phenomena of energy separation in vortex tubes was investigated experimentally to see the subsidiary effect of the conductivity of tube material and cooling conditions around the outer surface of the tube. The experiment was carried out with pyrex, stainless steel and copper tubes, and the heat transfer conditions of the tubes were with insulation, without in-sulation and water cooling modes respectively The results were obtained that the hot exit fluid temperature was highly affected by a change of conductivity of a tube when the outer surface was cooled by the water, while the working fluid through the tubes was air. How-ever, the cold exit temperature was little affected by the heat transfer modes on the outer surface of the vortex tube.

밀폐형 냉각탑의 열성능 특성에 관한 실험적 연구 (Thermal Performance Characteristics of Closed-Wet Cooling Tower)

  • ;김은필;문춘근;윤정인
    • 동력기계공학회지
    • /
    • 제9권2호
    • /
    • pp.88-92
    • /
    • 2005
  • The experiment of thermal performance about closed-wet cooling tower was conducted in this study. A closed cooling tower is a device similar to a general cooling tower, but with cooling tower replaced by a heat exchanger. The test section for this experiment has the process that the cooling water flows from the top of the heat exchanger to the bottom side in the inner part of the tube, and spray water flows in the gravitational direction in the outer side. Air comes in direct contact with the spray water at the outer side of the tube while passing from the lower the upper part having a counterflow to the spray water. The heat transfer pipe used in this experiment is a bare-type tube having an outer diameter of 15.88mm. The heat exchanger is consisted of seven rows and fifteen columns. In this experiment, thermal performance of the cooling tower is derived from overall heat transfer coefficients between the process fluid and sprayed water and volumetric overall mass transfer coefficient between sprayed water and air.

  • PDF

멀티패스 밀폐식 냉각탑의 성능특성에 대한 수치적 연구 (A Numerical Study on Performance Characteristics of a Closed Circuit Cooling Tower with Multi Paths)

  • 김은필
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권4호
    • /
    • pp.528-533
    • /
    • 2008
  • A closed circuit cooling tower having high temperature of cooling water and small water flow rate is investigated. To study the characteristics of the heat transfer of heat exchanges in a cooling tower with multi paths a numerical method is used. The results show that the staggered tube arrangements in a bank show better performance than aligned ones for temperature variation with various outer diameters of tube bundles. In case of one pass, the 15.88 mm tube case shows about 9% better performance than the 25.4 mm tube case. In two paths, the tube outside diameter of 15.88 mm show about 14.4% better results than the 25.4 mm diameter case.

냉방용 팬코일 유닛 열교환기의 열전달 및 압력강하 특성 실험연구 (Experimental Study on Heat Transfer and Pressure Drop of Heat Exchangers for Cooling Fan Coil Unit)

  • 권영철;고국원;권정태
    • 한국산학기술학회논문지
    • /
    • 제9권3호
    • /
    • pp.599-604
    • /
    • 2008
  • 본 연구에서는 냉방운전 시에 팬코일 유닛에 사용되는 핀-관 열교환기의 공기측 열전달 능력과 압력강하를 실험을 통하여 조사하였다. 실험을 위하여 칼로리미터와 항온수조를 이용하였다. 사용된 핀은 슬릿핀이며 5종 열교환기에 대해 배관회로와 실험조건을 변화하면서 실험하였다. 공기-물 정격유량에서의 냉방능력은 열교환기 공급 물온도가 낮은 조건이 우수하였으며, 배관회로에 따른 냉방능력은 배관 내 물흐름이 U형보다 ㄹ형인 경우에 더 크게 나타났다. 물유량이 증가할수록 냉방능력은 일정비율로 증가하였으며, 열교환기 공급 물 온도가 낮을 때 우수하였다. 공급 물 온도가 낮은 조건에서 많은 응축수가 생성되어 공기측 압력강하는 크게 나타났다.