• Title/Summary/Keyword: water control

Search Result 12,102, Processing Time 0.051 seconds

A Numerical Study on the Flow Characteristics of Temperature Control Valve by Pressure Compensation (압력 평형식 온도조절 밸브 내부 유동 특성에 대한 수치적 연구)

  • Hwang, J.H.;Kim, T.A.;Kim, Youn-J.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.448-453
    • /
    • 2005
  • Temperature Control Valve (TCV) is one of the useful temperature control devices, which is used to control constant temperature of working fluid in power and chemical plants and domestic water supply systems. TCV is composed of body, cylinder and piston, and the body shape has a symmetrical H-type. In general, it has several inlet and outlet holes, and its shape is like as tubular sleeve. The piston has three rings two rings of the end of piston have the function of controlling inlet flow rate with hot and cold working fluids, the center ring has the function of preventing hot and cold water from intermixing. Consequently, the shapes of piston and cylinder are the main design parameters in the performance of TCV. In this study, numerical analyses were carried out with two different piston and cylinder shapes to investigate the functions as a temperature control valve and the flow characteristics according to piston opening grade in TCV. Using a commercial code, FLUENT, velocity and pressure fields in TCV are obtained under steady, standard $k -{\epsilon}$ turbulence model and no-slip condition.

  • PDF

Predictive aeration control based on the respirometric method in a sequencing batch reactor (연속회분식반응조에서 호흡률에 기반한 포기공정의 예측제어)

  • Kim, Donghan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.6
    • /
    • pp.481-489
    • /
    • 2019
  • As aeration is an energy-intensive process, its control has become more important to save energy and to meet strict effluent limits. In this study, predictive aeration control based on the respirometric method has been applied to the sequencing batch reactor (SBR) process. The variation of the respiration rate by nitrification was great and obvious, so it could be a very useful parameter for the predictive aeration control. The maximum respiration rate due to nitrification was about 60 mg O2/L·h and the maximum specific nitrification rate was about 7.5 mg N/g MLVSS·h. The aeration time of the following cycle of the SBR was daily adjusted in proportion to that which was previously determined based on the sudden decrease of respiration rate at the end of nitrification in the respirometer. The aeration time required for nitrification could be effectively predicted and it was closely related to influent nitrogen loadings. By the predictive aeration control the aerobic period of the SBR has been optimized, and energy saving and enhanced nitrogen removal could be obtained.

Effect of Cnidi rhizoma Water-Extracted Solution on Fat Contents in Plasma, Liver and Adipose, and Fecal Steroids of Fatted Rats (천궁의 열수 추출액이 고지방식이에 의한 흰쥐의 혈장, 간 및 지방조직의 지질함량과 분변 Steroids에 미치는 영향)

  • Seong, Tae-Su;Son, Gyu-Mok;Bae, Man-Jong
    • The Korean Journal of Food And Nutrition
    • /
    • v.7 no.2
    • /
    • pp.100-107
    • /
    • 1994
  • This study was carried out to evaluate the effect of Cnidi rhizoma (CR) water extract on fat accumulation in fatted rats induced by the oral high fat administration for six weeks. Total cholesterol, neutral lipid and epididymal fat pad of CR groups were lower than the control group. On the other hand, high density lipoprotein(HDL) -cholesterol was somewhat higher In CR than In the control group. In addition, the same result as the above case was obtained when examining adipose for liver and epididymal fat components. During the feeding experiment, level of low density Lipoprotein(LDL) and very low density Lipoprotein (VLDL) increased while HDL was decreased. The degree of LDL and VLDL was decreased however, and HDL was, increased In CH groups as compared with the control group. Insulin and cortisol were higher than the control group, due to the fat accumulation. Experiment group showed the increased excretion as compared with the control group, in the excretion of bile acid and neutral sterol. The liver of the control group observed by the light microscope appeared to the fatty liver, but CR groups showed some improvement of the fatty liver. Based on the above results, it was shown that It Is possible to improve fat accumulation induced, by high fat dietary through using the oral administration of Cnidi rhizoma boiling extract solutions.

  • PDF

Distributed control system architecture for deep submergence rescue vehicles

  • Sun, Yushan;Ran, Xiangrui;Zhang, Guocheng;Wu, Fanyu;Du, Chengrong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.1
    • /
    • pp.274-284
    • /
    • 2019
  • The control architectures of Chuan Suo (CS) deep submergence rescue vehicle are introduced. The hardware and software architectures are also discussed. The hardware part adopts a distributed control system composed of surface and underwater nodes. A computer is used as a surface control machine. Underwater equipment is based on a multi-board-embedded industrial computer with PC104 BUS, which contains IO, A/D, D/A, eight-channel serial, and power boards. The hardware and software parts complete data transmission through optical fibers. The software part involves an IPC of embedded Vxworks real-time operating system, upon which the operation of I/O, A/D, and D/A boards and serial ports is based on; this setup improves the real-time manipulation. The information flow is controlled by the software part, and the thrust distribution is introduced. A submergence vehicle heeling control method based on ballast water tank regulation is introduced to meet the special heeling requirements of the submergence rescue vehicle during docking. Finally, the feasibility and reliability of the entire system are verified by a pool test.

Growth and Development of Platycodon grandiflorus under Sensor-based Soil Moisture Control on Open Farmland and Pot Conditions

  • Lee, Ye-Jin;Kim, Kyeong-Soo;Lim, So-Hee;Yu, Young-Beob;Bae, Chang-Hyu
    • Korean Journal of Plant Resources
    • /
    • v.34 no.6
    • /
    • pp.608-615
    • /
    • 2021
  • Soil moisture control system including soil sensing and automatic water supply chain was constructed on open farmland and pot conditions. Soil moisture was controlled by the system showing over the soil moisture contents except 40% treatment. EC was gradually decreased by increasing cultivation days. On applying this system to control soil moisture, the growth and development characters of the bellflower were improved compared with control, cultivation without the automatic irrigation. Of the growth and development characters, plant height with water treatments was higher than that of control in 1st-year plants. Moreover, numbers of branch were increased by the increased soil moisture on farmland and pot condition. Capsule numbers for seed were best at 20%, 30% soil moisture treatment in 1st-year plants, and 20% to 50% treatment in 2nd-year plants. The construction of automatic soil moisture control system provide fundamental data for plant growth and development on open farmland soil condition.

Cooling Performance Analysis of Ground-Source Heat Pump System with Capacity Control with Outdoor Air Temperature (외기 온도 제어 방식을 적용한 지열 히트펌프 시스템의 냉방 성능 분석)

  • Sohn, Byonghu
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.4
    • /
    • pp.68-78
    • /
    • 2021
  • In order to solve the increasing deterioration of the energy shortage problem, ground-source heat pump (GSHP) systems have been widely installed. The control method is a significant component for maintaining the long-term performance and for reducing operation cost of GSHP systems. This paper presents the measurement and analysis results of the cooling performance of a GSHP system using capacity control with outdoor air temperature. For this, we installed monitoring equipments including sensors for measuring temperature, flow rate and power consumption, and then monitored operation parameters from July 9, 2021 to October 2, 2021. From measurement results, we analyze the effect of capacity control with outdoor air temperature on the cooling performance of the system. The average performace factor (PF) of the heat pump was 6.95, while the whole system was 5.54 over the measurement period. Because there was no performance data of the existing GSHP system, it was not possible to directly compare the existing control method and the outdoor air temperature method. However, it is expected that the performance of the entire system will be improved by adjusting the temperature of cold water produced by the heat pump, that is, the temperature of cold water on the load side according to the outside air temperature.

A study on the measures to use Gunnam flood control reservoir through a reservoir simulation model (저수지 모의 모형을 통한 군남홍수조절지의 활용방안에 관한 연구)

  • Yang, Wonseok;Ahn, Jaehwang;Yi, Jaeeung
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.6
    • /
    • pp.407-418
    • /
    • 2017
  • Due to geographical features of being close to DPRK (Democratic People's Republic of Korea), the Imjin River basin has difficulties in hydrological observation, and is vulnerable to unexpected flood occurrence. As a countermeasure, Gunnam Flood Control Reservoir construction was planned in 2005. Despite such a structural measure, damages by DPRK's illegal release continues to occur. Futhermore the Imjin River's flow has been decreased due to the effect of continuous drought in the Korean Peninsula since 2012 and DPRK's unilateral storage of water. A new operation method is derived for the Gunnam Flood Control Reservoir in order to cope with drought damages on the Imjin River basin and to ensure efficient response time upon flooding. The operation method maintaining Gunnam Flood Control Reservoir's water level by raising from EL.23.0 m to EL.31.0 m during the flood season for securing reservoir capacity enables to secure additional $14,000,000m^3$ water compared to the existing operation methods. The operation method to store inflow by controlling release to $250m^3/s$ in the early stage of flood has increased 2.66% on average in terms of detention effect of reservoir compared to the existing operation methods. The method enables to secure 19 hours to prepare flood compared to the existing methods.

Effects on the Quality Characteristics of Mul-kimchi with Omija (Schizandra chinensis Baillon) Water Extract (오미자 물 추출물을 이용한 물김치의 품질특성)

  • Jeong, Tae-Seong;Jeong, Eun-Ju;Lee, Shin-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.10
    • /
    • pp.1301-1306
    • /
    • 2008
  • The physiological and microbiological characteristics of various mul-kimchis prepared with omija (Schiznadra chinensis) water extract (1, 2, 3 v/w%) (omija mul-kimchi ) or water (control) were investigated during fermentation for 21 days at $10^{\circ}C$. The pH of omija mul-kimchi was lower than that of control and lowered with increasing the concentration of omija between 1% and 3%. The pH did not change significantly during fermentation in omija mul-kimchi compared with control. The changes in titratable acidity were similar in pH. The change of total microbs and lactic bacteria during fermentation was similar in various mul-kimchis and the viable cell numbers in omija mul-kimchi were lower than in control. The viable cell of mul-kimchi decreased with increasing the concentration of omija water extract. The texture of various mul-kimchi such as hardness, cohesiveness, chewiness and springiness, was decreased but the texture of 1% omija mul-kimchi was maintained significantly higher than that of control during fermentation. The DPPH radical and nitrite scavenging activity of omija mul-kimchi were higher than those of control and the activities increased with increasing concentrations of omija water extract. The sensory quality of 1% omija mul-kimchi showed the highest value in taste and overall acceptability among the tested mul-kimchis.

Application of Inference Models for Estimating Parameters of a Catchment Modelling System (추론모델을 통한 강우-유출모형 매개변수의 간접추정법 적용)

  • Choi, Kyung-Sook
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.4
    • /
    • pp.587-596
    • /
    • 2003
  • Application of a catchment modelling system requires recorded information to ascertain the reliability and robustness of the predicted flow conditions. Where this recorded information is not available, the necessary information for reliable and robust predictions must be obtained from other available information sources. The alternative approach presented in this paper used inference models for getting this necessary information that is required to calibrate and validate the catchment modelling system for both an ungauged and a gauged catchments. In this study, inference models were developed for determination of control parameters of the Storm Water Management Model (SWMM), mainly based on landuse component of the catchment, which is a major factor to impact on quantity and quality of catchment runoff. Results from the study show that the new approach for determination of the spatially variable control parameters produced more accurate estimates than a traditional approach. Also, the number of control parameters estimated can be reduced significantly as the proposed method only requires determination of control parameters associated with each land use of the catchment while a traditional approach needs to assign a number of control parameters for a number of subcatchment.

Effect of Irrigation of River Water and Swine Slurry Liquid Fertilizer on Kenaf (Hibiscus cannabinus L.) Growth Cultivated Using Soil Moisture Control System in Reclaimed Land (자동 수분 제어시스템을 이용한 간척지 케나프 재배시 하천수 및 액비 관개 효과)

  • Kang, Chan-Ho;Lee, In-Sok;Lee, Jin-Jae;Kim, Hee-Jun
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.66 no.1
    • /
    • pp.87-96
    • /
    • 2021
  • Information and Communication Technology (ICT) remote soil moisture control system including soil sensing, automatic water supply chain, and remote alarming system was established on reclaimed land and operated stably. The system was operated using river water around the reclaimed land without fertilizer. On applying this system to control soil moisture, the kenaf germination rate was improved up to two times. Kenaf biomass was 4,748 kg/10a and was higher than that of untreated soil moisture management. When the nutritious liquid fertilizer was used, kenaf yield reached 8,390 kg/10a, which was lower than 10,848 kg/10a of the non-reclaimed land treated with standard chemical fertilizers. As the soil moisture was managed stably through the ICT remote soil moisture control system, the quality of the kenaf crop was improved, resulting in a 7% increase in dry weight, and a 11.5% increase in plant hardness. The estimated kenaf yield was 5,039 kg/10a when 800 tonnes of water were supplied by the ICT remote soil moisture control system with the stream water around Saemangeum reclaimed land without chemical fertilizers and organic matter.