• Title/Summary/Keyword: water control

Search Result 12,102, Processing Time 0.041 seconds

A Cellular Physiological Study on the Effects of Korean Ginseng -Part I. Effects on the Division of Saccharomyces- (인삼의 효과에 관한 세포생리학적 연구 -제 I 편 Saccharomyces의 분열에 미치는 영향-)

  • Jung, Noh-Pal
    • The Korean Journal of Physiology
    • /
    • v.3 no.1
    • /
    • pp.45-49
    • /
    • 1969
  • The effects of water extracts and powder of Korean ginseng on the division of Saccharomyces cerevisiae were studied. 1. The addition of several doses of water extracts and powder of ginseng to the yeast medium of Moyer and Coghill showed various promoted division of Saccharomyces. 2. The optimal dose of ginseng on tile division of Saccharomyces (0.08% dry ginseng medium solution per $10\;cells/mm^3$) could be recognized. 3. On the culture for 24 hours at $18^{\circ}C$, the cell number of control group was $13.25{\times}10^3\;cells/mm^3$ and that of the optimal dose group of water extracts of ginseng was $23.20{\times}10^3\;cells/mm^3$. On the culture, for 24 hours at $25^{\circ}C$, the cell number of control group was $16.85{\times}10^3\;cells/mm^3$ and that of the optimal dose group was $30.20{\times}10^3\;cells/mm^3$. The increasing rate of cell divison by the ginseng was about twice than that of control group. The optimal dose treatment of ginseng at $18^{\circ}C$ was more effective than control group at $25^{\circ}C$. 4. On the culture for 24 hours at $18^{\circ}C$, the increasing rate of water extracts of ginseng was 75.1%, and the rate of ginseng powder was 7.6%. On the culture for 24 hours at $25^{\circ}C$, the rate of water extracts of ginseng was 79.8%, and the rate of ginseng powder was 57.2%. Therefore water extracts of ginseng was more effective than ginseng powder of same dry weight, and the promoted effect of ginseng powder at $25^{\circ}C$ was more effective than at $18^{\circ}C$.

  • PDF

Effects of Controlled Drainage Systems on Soybean (Glycine max L.) Growth and Soil Characteristics in Paddy Fields

  • Lee, Sanghun;Jung, Ki-Yuol;Chun, Hyen Chung;Choi, Young Dae
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.62 no.2
    • /
    • pp.134-142
    • /
    • 2017
  • Crop production in rice paddy fields is of great importance because of declining rice consumption and the low self-sufficiency ratio for field crops in Korea. A controlled drainage system (CDS) is recognized as an effective means to adjust water table (WT) levels as needed and control soil water content to improve the soil environment for optimum crop growth. The present study evaluated the effects of a CDS on soil characteristics, including soil water distribution and soybean development in paddy fields. The CDS was installed with two drain spacing (3 m and 6 m) at the experimental paddy field at the National Institute of Crop Science, Miryang, Korea. It was managed with two WT levels (0.3 m and 0.6 m) during the growing season. Soil water content, electrical conductivity and plant available nitrogen content in the soil were significantly greater in the 0.3 m WT management plots than in the 0.6 m plot and the control. At the vegetative stage, chlorophyll content was significantly lower with higher WT control because of excess soil moisture, but it recovered after the flowering stage. Soybean yield increased with WT management and the 0.6 m WT treatment produced the greatest grain yield, $3.38ton\;ha^{-1}$, which was 50% greater than that of the control. The CDS directly influenced outflow through the drains, which significantly delayed nutrient loss. The results of this study indicated that WT management by CDS can influence soil characteristics and it is an important practice for high yielding soybean production in paddy fields, which should be considered the crop growth stages for stable crop production.

The development of industrial secure L2 switch and introduction example for management and security improvement of supervisory control network in purification plant (정수장 감시제어망의 관리와 보안개선을 위한 산업용 보안 L2스위치 개발 및 적용사례)

  • Kim, Yunha;Yu, Chool;Oh, Eun;Kim, Chanmoon;Park, Ikdong;Kim, Yongseong;Choi, Hyunju
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.5
    • /
    • pp.329-339
    • /
    • 2019
  • Recently, the advancement of information and communication technology(ICT) is expanding the connectivity through Internet of Things(IoT), and the media of connection is also expanding from wire/cable transmission to broadband wireless communication, which has significantly improved mobility. This hyperconnectivity has become a key element of the fourth industrial revolution, whereas the supervisory control network of purification plants in korea is operated as a communication network separated from the outside, thereby lagging in terms of connectivity. This is considered the best way to ensure security, and thus there is hardly any consideration of establishing alternatives to operate an efficient and stable communication network. Moreover, security for management of a commercialized communication network and network management solution may be accompanied by immense costs, making it more difficult to make new attempts. Therefore, to improve the conditions for the current supervisory control network of purification plants, this study developed a industrial security L2 switch that supports modbus TCP(Transmission Control Protocol) communication and encryption function of the transmission section. As a result, the communication security performance improved significantly, and the cost for implementing the network management system using Historical Trend and information of HMI(Human Machine Interface) could be reduced by approximately KRW 200 million. The results of this study may be applied to systems for gas, electricity and social safety nets that are infrastructure communication networks that are similar to purification plants.

The Effect of CaO2 Application on the Change of Sedimentary Phosphorus Fraction and Water Quality (CaO2 적용에 따른 퇴적물의 P fraction 변화와 수질에 미치는 영향)

  • Kim, Beom-geun;Khirul, Md Akhte;Kwon, Sung-Hyun
    • Journal of Environmental Science International
    • /
    • v.28 no.5
    • /
    • pp.511-520
    • /
    • 2019
  • This study was investigated to improve the phosphorus release and water quality by transformation of sedimentary P fraction for application of $CaO_2$. For the experiment, 0.5% (w/w) of $CaO_2$ was homogenized in the sediment and incubated with the control for 20 days. The analytical results showed that pH increased with $CaO_2$ and redox potential (ORP) was improved in the sediment of the reactor. The growth rate of chlorophyll-a was lower in the $CaO_2$ reactor and Dissolved Oxygen (DO) of overlying water maintained higher than that of the control. Total phosphorus (T-P) concentration in the overlying water increased from the initial concentration to 0.304mg/L in the control at 20 days. The reactor of $CaO_2$ was lowered by 29.3%. Ex-P, Fe-P and Ca-P in sediment P fraction were increased with the $CaO_2$. The formation of bound Fe-P and Ca-P in the sediments seemed to control the release of P by removing the Soluble Reactive Phosphorus (SRP) presented in the pore water. From the result, this indicated that the reduction of P release from the sediments seems to be effective in suppressing the eutrophication of P and improving the oxygen condition in the water quality with the application of $CaO_2$.

A review on the risk, prevention and control of cooling water intake blockage in coastal nuclear power plants

  • Heshan Lin;Shuyi Zhang;Ranran Cao;Shihao Yu;Wei Bai;Rongyong Zhang;Jia Yang;Li Dai;Jianxin Chen;Yu Zhang;Hongni Xu;Kun Liu;Xinke Zhang
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.389-401
    • /
    • 2024
  • In recent decades, numerous instances of blockages have been reported in coastal nuclear power plants globally, leading to serious safety accidents such as power reduction, manual or automatic power loss, or shutdown of nuclear power units. Loss or shortage of cooling water may compromise the reliability of the cooling water system, thus threatening the operational safety of power plants and resulting in revenue reduction. This study provides a comprehensive review of the current state of cooling water system safety in coastal nuclear power plants worldwide and the common challenges they face, as well as the relevant research on cooling water system safety issues. The research overview and progress in investigation methods, outbreak mechanisms, prevention and control measures, and practical cases of blockages were summarized. Despite existing research, there are still many shortcomings regarding the pertinence, comprehensiveness and prospects of related research, and many problems urgently need to be solved. The most fundamental concern involves understanding the list of potential risks of blockages and their spatially distributed effects in surrounding waters. Furthermore, knowledge of the biological cycles and ecological habits of key organisms is essential for implementing risk prevention and control and for building a scientific and effective monitoring system.

Development of the Dynamometer Control System for Medium Speed Diesel Engines

  • Choi, Sang-Gu;Ryu, Sang-Hun;Kim, Jeom-Goo;Park, Ho-Chol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.243-247
    • /
    • 2004
  • The dynamometers which had made in a long time ago could not control the input/output quantity of water minutely and was sensitive to a noise since it was controlled by an analog control method. Therefore, a fully digital controlled system was urgently required to be robust against various noises. In this paper, the new system which can control the amount of circulated water in dynamometer was developed. This system is consisted of an industrial digital type controller and a servo motor. The industrial PLC was used as a main controller for the developed system, and the actuator and servo motor were used to control the inlet and outlet valve independently. The torque signal of load cell was fed back to the main controller to regulate the diesel engines load. Generally, an input/output valve position of the old dynamometer was fixed with a proper situation for an engine output test and the torque was changed according to the time interval. However, the torque value for the dynamometer could not be constantly kept because of the variation of the input water flow and fluid characteristic. Therefore, the automatic control of an inlet and outlet valve should be performed to keep the constant torque. So, the PID control method was applied to solve this problem. Also, the development of a web-based remote control system was described in this paper. This software will give us the convenience of operation, the more efficient operations, and the reduced operator workload for operation of the dynamometer. The application results of the system have been verified at actual diesel engine field.

  • PDF

Effect of Tea Fungus/Kombucha Beverage on Serum and Liver Lipids Metabolism in Rats (발효홍차 음료가 흰쥐가 혈청과 간의 지질대사에 미치는 영향)

  • 고진복
    • Journal of Nutrition and Health
    • /
    • v.33 no.5
    • /
    • pp.497-501
    • /
    • 2000
  • We investigated the effect of tea fungus/kombucha(TF) beverage on serum and liver lipid metabolism in growing male rats. The rats(Sprague-Dawley) were divided into five groups; control(TF free water), 20 or 40% TF groups(20 or 40% TF in water) and 20 or 40% TFS groups(20 or 40% TF autoclaved in water) according to the level of TF supplementation. The rats were fed ad libitum each of the experimental beverage for 7 weeks. The body weight gain of all the TF and TFS groups were similar to that of the control group. The total lipid and triglyceride concentrations of serum in the 40% TF group were increased more than those in the control group, but those in the 20% TF and 20% TFS groups were similar to that of the control group. The total cholesterol, HDL-cholesterol concentrations, HDL-cholesterol / total cholesterol ratio and atherogenic index of serum in all the TF and TFS groups were similar to those of the control group. The LDL-cholesterol concentration of serum was significantly lower in the 20% TF group than that in the control group. The LDL-cholesterol concentration of serum was significantly lower in the 20% TF group than that in the control group, but those of the 40% TF, 20% TFS and 40% TFS groups were similar to that of the control group. The liver weights of all the TF and TFS groups were heavier than that of the control group. The concentrations of hepatic triglyceride in the 20% TF and 20% TFS groups were significantly decreased, compared with that in the control group. The concentrations of hepatic total cholesterol in all the TF and TFS groups were significantly more decreased than that in the control group. These results indicated that the liver weights of tea fungus/kombucha beverage feeding rats were increased, also the serum triglyceride and total cholesterol concentrations of 40% TF feeding rats were increased. but the serum LDL-cholesterol, hepatic triglyceride and cholesterol levels of 20% TF feeding rats were decreased.

  • PDF

Search Method for Optimal Valve Setting and Location to Reduce Leakage in Water Distribution Networks (배수관망시스템 누수저감을 위한 최적 밸브제어 및 위치탐색 모델 개발)

  • Choi, Jong Sub;Kala, Vairavamoorthy;Ahn, Hyo Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.149-157
    • /
    • 2008
  • The reduction of leakage is a major issue of the South Korea water industry. The inclusion of pressure dependent leakage terms in network analysis allows the application of optimization techniques to identify the most effective means of reducing water leakage in distribution networks. This paper proposes a method to find optimal setting and location of control valve for reducing leakage efficiently. The proposed search method differs from previous methods for addressing optimal valve location problem and improves the GA simulation time with guaranteeing for getting the global optimal solution. The strength of this method has been demonstrated by means of case studies. This allows the procedure of optimization to be more robust and computational efficient.

Water quality monitoring at irrigation districts polluted with wastewater for the wastewater reuse for agriculture (생활하수의 농업용수재이용을 위한 생활하수 오염지구 수질 모니터링)

  • Kim, Sang-Min;Park, Seung-Woo;Kang, Moon-Sung
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.401-404
    • /
    • 2002
  • Two irrigation districts, Maekok and Byungjum 1 which are irrigated with polluted stream flow, and one control district Kichun, that is supplied from a reservoir complying with the water quality standard are selected for water quality monitoring to identify the effects of polluted irrigation on crop yields, environments, and health hazards for farmers. The water quality at Maekok and Byungjum 1 districts are worse than the control district, and continuous water quality monitoring are needed for the wastewater reuse for agriculture.

  • PDF

An Evaluation study on Total Nitrogen(T-P) Item of Agricultural Water Standards (농업용수 수질기준 T-P 항목에 대한 검증실험(I))

  • Choi, Sun-Hwa;Kim, Ho-Il;Yoon, Kyung-Seup;Lee, Bong-Hun
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.603-606
    • /
    • 2003
  • This study was carried out to investigate the effects of T-P concentrations in irrigation water on the growth, yield, and grain quality of rice. It acquire fundamental knowledges to set up irrigation water quality standards. The pot experiment was conducted with 5 treatments using irrigation waters. It consisted of various total phosphorus concentrations(control, 1, 2, 5, 10mg/L) and replicated four times with randomized block design. The results of this study showed that as T-P concentrations in irrigation water increases, plant height tended to increase. Dry weight of rice plant at T-P 10mg/L was significantly higher than the control. However, T-P in irrigation water did not affect plant height, tiller number, plant dry weight, yield, and quality of rice.

  • PDF