• Title/Summary/Keyword: water control

Search Result 12,102, Processing Time 0.056 seconds

The Effect of Extracts of Berberis koreana Bark by Lactobacillus Fermentation on the Concentration of Serotonin and Melatonin in the Serum of Treated ICR Mice (유산균 발효된 매자나무 추출물이 마우스 혈청중의 Melatonin 및 Serotonin의 함량에 미치는 영향)

  • Ling, Jin;Kim, Ji-Seon;Seo, Yong-Chang;Choi, Woon-Yong;Ahn, Ju-Hee;Ma, Choong-Je;Yoon, Chang-Soon;Lee, Hyeon-Yong
    • Korean Journal of Medicinal Crop Science
    • /
    • v.19 no.2
    • /
    • pp.117-125
    • /
    • 2011
  • This study was to investigate the effect of fermentation extracts on the concentration of serotonin and melatonin in the serum of the ICR mice. The ICR mice were divided into water control group, lactobacillus fermentation solution including (Lactobacillus paracasei and Bifidobacterium longum B6) control group, positive control group (milk and doxylamine succinate), negative control group (caffein) and the groups treated with the extracts of Berberis koreana bark (WE: water extracts, FE-L.P: fermentation extracts of Lactobacillus paracasei, FE-B.L: fermentation extracts of Bifidobacterium longum B6). After ten-day feeding treatment, the mean concentration of serotonin for water control, WE, FE-L.P and FEB. L group was 134.72, 183.01, 232.09 and $223.78 ng/m{\ell}$, respectively. The mean concentration for FE-L.P and FE-B.L group were approximately 66% larger than that for water control group. The mean concentration of melatonin for water control, WE, FE-L.P and FE-B.L group was 76.92, 106.66, 157.56 and $141.81pg/m{\ell}$, respectively. The mean concentration of melatonin for FE-L.P and FE-B.L group were also larger than that for water control group. Our results indicated that the fermentation extracts of Berberis koreana bark have relatively greater potential to induce secretion of serotonin and melatonin. Therefore, the fermentation extracts have antidepressant effect.

A Effect on the Maintenance of Chicken Freshness through $\pi$-Water Treatment ($\pi$-Water 처리를 통한 닭고기의 신선도 유지 효과)

  • 김윤태
    • Culinary science and hospitality research
    • /
    • v.8 no.2
    • /
    • pp.197-206
    • /
    • 2002
  • The present study attempted to obtain a basic data concerning the effect of $\pi$-water, a sort of physiological water, on the maintenance of chicken freshness. The meats were divided into three groups: the control, 20% - dilution, and 5% - dilution groups. In the experiment, the changes of the TBA-values of the meats started to appear on the 3rd day in the control group, and from the 4th day in the 20% - and 5% - dilution groups. The changes of pH didn't appear in the meats as the storage time passed. The number of general bacteria increased rapidly on the 3th day in the control, and on the 5th day in the 20% -, and 5% - dilution groups. As for the color, the meats turned greenish on the 5th day in the control, 7th, in 20% - dilution, and, l0th in the 5%-dilution groups. As for the order, the meats emitted the unpleasant order, such as that of ammonia, on the 3rd day in the control, 5th, in the 20% - dilution, and, 7th, in the 5ft-dilution group.

  • PDF

Control of Surface Energy using Bilayer Metallic Film Heterostructures

  • Kim, Chang-Lae;Kim, Dae-Eun;Kim, Hae-Jin
    • Tribology and Lubricants
    • /
    • v.35 no.6
    • /
    • pp.350-355
    • /
    • 2019
  • Surface energy is an important factor in determining the performance of application components in terms of preventing adhesion failure between thin films. In this regard, numerous attempts have been made to acquire the desired surface energy through chemical treatment or by using micro/nanostructures. However, such approaches are expected to provide extreme values of surface energy, which may not be suitable in achieving the enhanced performance of applications. In this study, we propose a method to control surface energy by using bilayer metallic film heterostructures. We measure the water contact angle of incompatible (Ni/Ag) and compatible (Zn/Ag) metal pairs under several experimental factors, including thickness, time, and temperature. Furthermore, we conduct Auger electron spectroscopy measurements to investigate the atomic concentration with respect to depth after the change in the water contact angle. The experimental results reveal that three parameters, namely, compatibility, film thickness, and environmental temperature, are major factors in controlling the water contact angle. Thus, we experimentally demonstrate that controlling these three parameters can provide the approximate desired water contact angle. This result is expected to aid in the performance enhancement of a wide range of application components, where control of surface energy is required.

Flow Network Analysis for the Flow Control of a Main Cooling Water System in the HANARO Fuel Test Loop (하나로 핵연료 시험 루프 주냉각수 계통의 유량 제어에 대한 유동 해석)

  • Park, Young-Chul;Lee, Yong-Sub;Chi, Dae-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.5
    • /
    • pp.7-12
    • /
    • 2009
  • A nuclear fuel test loop(after below, FTL) is installed in the IRI of an irradiation hole in HANARO for testing the neutron irradiation characteristics and thermo hydraulic characteristics of a fuel loaded in a light water power reactor or a heavy water power reactor. There is an in-pile section(IPS) and an out-pile section(OPS) in this test loop. When HANARO is operated normally, the fuel loaded into the IPS has a nuclear reaction heat generated by a neutron irradiation. To remove the generated heat and to maintain the operation conditions of the test fuel, a main cooling water system(MCWS) is installed in the OPS of the FTL. The MCWS is composed of a main cooler, a pressurizer, two circulation pumps, a main heater, an interconnection pipe line and instruments. The interconnection pipeline is a closed loop which is connected to an inlet and an outlet of the IPS respectively. The MCWS is under a cold function test during a start-up period. This paper describes the system flow network analysis results of the flow control of a main cooling water system in the HANARO fuel test loop. It was confirmed through the results that the flow was met the system design requirements.

The Effects of Neuromuscular Re-education on Physical Composition, Body Water, and Functional Independence in Stroke Patients (신경근 중재 접근이 뇌졸중 환자의 신체조성, 체수분 및 기능적 독립성에 미치는 영향)

  • So, Kyoung-Suk;Shin, Hong-Cheul;Kang, Jeong-Il
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.1
    • /
    • pp.11-31
    • /
    • 2006
  • Purpose: The purpose of this study is to investigate the effect of neuromuscular re-eduction program and traditional intervention program. Methods: It is focused on difference between changes of experimental before and after on 30 stroke patient's physical composition, body water and functional independence. Results: The obtained results are as follows ; 1. In the comparison of change in physical composition between the experimental group and control group, the between-subjects factors were not a significant difference. 2. In the comparison of change in body water between the experimental group and control group, the between-subjects factors were not a significant difference. 3. In the comparison of change in functional independence between the experimental group and control group, the between-subjects factors were a significant difference in 8 items and total FIM (p<0.01; p<0.05) but, were not a significant difference in 11 items. Conclusion: the neuromuscular re-eduction program was more effect then traditional intervention program in functional independence but, was not a significant difference in body composition and body water.

  • PDF

Review on Nutrient and Blood (영(營)과 혈(血)에 대한 고찰)

  • Eom, Dong-Myung;Song, Ji-Chung;Jeong, Heon-Young
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.24 no.4
    • /
    • pp.553-558
    • /
    • 2010
  • Nutrient and Blood are really common conceptions in Traditional Korean Medicine(TKM). However, those are used in mixed. not only because of their common points but users who doesn't have clear classifications between them. Therefore, I will explain those owns by explaining origins, places of origons, pathway, circulations, organs related to them and color. In addition, I will try to explain thi things in common without conceptions of their own. As a result, the first, nutrient is what is originated from water and food at middle energizer and circulated in meridian vessel by control of spleen. The second, blood is what is originated from qi of water and food and circulated in blood vessel by control of heart and its color is red. The third, nutrient blood is what is originated from water and food or qi of water and food and circulated in meridian or blood vessel by control of spleen and heart. Also it is red and its function is nourishing human body. The name of Nutrient blood is a new term that I made and it is different from nutrient or blood. Also it is different from nutrient and blood. Nutrient blood is combination by conceptions, nutrient and blood is combination by word itself.

Development of Three-Way Proportional Control Valve and Performance Study (3방 비례제어 조절밸브 개발 및 성능 연구)

  • Lee, Jonghwa;Jung, Taeksu;Cho, Chongdu;Kim, Jooyong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.5
    • /
    • pp.218-223
    • /
    • 2014
  • Korea District heating corp. recently give an attention to combine the district heating and supply pipes as a two pipe system that are in the present system separated with room heating and warm water supply pipe, and the two pipe system is commonly applied for heating service in European countries. In the new two pipe system, only one heat source is supplied to a house and partitioned into room heating and warm water supply by household substation. So the effective distribution of supplied heat source in accordance to user intention is very important. This paper presents the development and performance test of three-way proportional control valve for a combined heat source system in district heating. The proposed valve is controlled to partition heat source into two different directions : hot water distributor for space heating and household substation for warm water supply in response to the pressure drops of tap water caused by the user. The performance investigation is shown within 3% of error compared to the theoretical model of the three-way proportional valve and its controllability is verified.

Selection of Chemicals for the Dissolved Phosphorus Control by Variations of Alkalinity and Hardness (용존인 제어를 위한 알칼리도와 경도 조절제의 선택)

  • Kim, Sungok;Kim, Hag Seong
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.2
    • /
    • pp.206-211
    • /
    • 2014
  • This study was done to find chemicals adequate to control alkalinity and hardness in order to reduce dissolved phosphorus in water bodies like rivers and lakes. Five chemicals were selected for the study: calcite, lime, dolomite, magnesite, and gypsum. Data were obtained from the calculations with MINTEQ model as a function of dosage variations of each chemical. Findings are as follows: Three out of the five chemicals are found to be effective in reducing the dissolved phosphorus, i.e., calcite, lime, and dolomite. Calcite and dolomite are able to lower the phosphorus concentration up to one thousandth fold whereas lime does one hundred thousandths fold. In viewpoint of pH variation, both calcite and dolomite seem to be safe since the pH does not increase over 8.3 even in case of overdose. In the same circumstance, with lime the pH increases beyond 9 which is considered to be the highest pH level for the protection of water ecosystem. Nevertheless it is recommendable to use lime in case where there are some difficulties in water quality control due to algae blooms.

Preliminary Release Scheme by Flood Forecasting (홍수예측에 의한 예비방유 방안)

  • Sim, Myeong-Pil;Lee, Jae-Hyeong;Gwon, O-Ik
    • Water for future
    • /
    • v.29 no.1
    • /
    • pp.235-248
    • /
    • 1996
  • Apreliminary release scheme (PRS) is suggested for the operating rules during flood period to deal with conflicts between flood control and water conservation purposes. PRS can be used to decide the optimum releases, based on the forecast of an oncoming flood and flow rate at the control point downstream when comparing the variable restricted water level (VRWL) for flood control with the minimum required water level (MRWL) for conservation use. The model is applied to Chungju and Daechung reservoirs through simulations of the technique. This study illustrates the procedure to decide the time and size for preliminary releases. Also, effects of duration and magnitude of preliminary release are reviewed based on historicqal flood records. The simulation results indicate that the proposed PRS is effective for the managers to find optimal operating policies during flood period. The proposed scheme can be used with main release scheme using real-time operation on hour-to-hour basis to decide the release for a flood.

  • PDF

A study on a precision temperature control unit using thermoelectirc module (열전소자를 이용한 정밀 항온 유지 장치에 관한 실험 및 시뮬레이션 연구)

  • Park, Kyung-Seo;Song, Young-Joog;Im, Hong-Jae;Jang, Si-Yeol;Lee, Kee-Sung;Jeong, Jay;Shin, Dong-Hoon
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.1937-1941
    • /
    • 2007
  • During a process of a nanoimprint for manufacturing LCD, a small temperature variation on the LCD glass can cause thermal stress and generate unexpected displacement. To avoid this trouble, a precision temperature control unit using thermoelectric modules is appropriate for nanoimprint processes. The unit consists of an air control system, a cooling water control system, and a power control system. The air control system includes a thermoelectric module, thermocouples measuring temperatures of air and a duct-stale fin, and two air fans. The heat generated by the thermoelectric module is absorbed by the cooling water control system. The power control system catches the temperature of the thermoelectric module, and a PID controller with SCR controls the input power of the thermoelectric module. Temperature control performance is evaluated by experiment and simulation. The temperature control unit is able to control the exit temperature about ${\pm}2^{\circ}C$ from the incoming fluid temperature, and the error range is ${\pm}0.1^{\circ}C$. However, the control time is approximately 30minute, which needs further study of active control

  • PDF