• Title/Summary/Keyword: water control

Search Result 12,102, Processing Time 0.042 seconds

Fire Suppression Experiment for Road Tunnel Low Pressure Water Spray Systems (도로터널 저압 물분무설비 화재진압 실험)

  • Choi, Byung-Il;Han, Yong-Shik;Kim, Myung-Bae;So, Soo-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.218-221
    • /
    • 2008
  • The real scale fire suppression test inside a road tunnel were carried out for water spray systems. The dimension of the tunnel is 7.5m in height and 11.6m in width. 3 different water spray nozzle systems with low operating pressure less than 3.5 bar were used in the experiment. Two types of fires were tested. One is a $1.4m^2$ heptane pool fire and the other is a 2000CC passenger car fire. From the experiment, the spray densities of tested systems were about $6.0\;l/min/m^2$ which is currunt domestic guideline. Although all the systems cannot extinguish the tested fires, it was found that they can reduce the tunnel temperature and have a capability to control and suppress the tested fire.

  • PDF

Mechanism Investigation and Measures on Acoustic Vibration Phenomena of Water Supply Piping (급수 배관계의 음향진동 현상 고찰 및 대책)

  • Kim, Yeon-Whan;Bae, Yong-Chae;Lee, Doo-Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.470-475
    • /
    • 2012
  • The downstream piping system of the water supply system in a supercritical power plant is affected by the fluctuation pressure waves induced by accessing to the acoustic modes of the piping systems with the rotation and impeller passing pulsations of the feed water pump. There are the phenomena amplified at the same time in the range of 415 ~ 455Hz, 830 ~ 910Hz, 1245 ~ 1365Hz and 1660 ~ 1820Hz on the spectrums of the vibration, the sound pressure, and the pressure fluctuation waves.

  • PDF

Mechanical and Water Barrier Properties of Soy Protein and Clay Mineral Composite Films

  • Rhim, Jong-Whan;Lee, Jun-Ho;Kwak, Hyo-Sup
    • Food Science and Biotechnology
    • /
    • v.14 no.1
    • /
    • pp.112-116
    • /
    • 2005
  • Composite films were prepared with soy protein isolate (SPI) and various clay minerals by casting from polymer and clay water suspension. Effects of clay minerals on film thickness, moisture content (MC), tensile strength (TS), elongation at break (E), water vapor permeability (WVP), and water solubility (WS) were tested. Properties including thickness, surface smoothness, and homogeneity of films prepared with organically modified montmorillonite (O-MMT), Wamok clay (W-clay), bentonite, talc powder, and zeolite were comparable to those of control SPI films. TS increased significantly (p<0.05) in films prepared with O-MMT and bentonite, while WVP decreased significantly (p<0.05) in bentonite-added films. WS of most nanocomposite films decreased significantly (p<0.05).

An Experimental Study on the Physical Characteristics of Cement Mortar with Cellulose Fiber and Diatomite (목질섬유 및 규조토 혼입 시멘트 모르터의 물성에 관한 실험적 연구)

  • 김경민;박석근;이수용
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.103.2-108
    • /
    • 2003
  • The purpose of this study is to understand the Physical characteristics of cement mortar about humidity control on indoors and wall crack restraint. Experiments were conducted on the strength, water absorption coefficient, drying-shrinking crack, length change, cracks of mortar plaster bases according to mixture rate by mixing cellulose fiber and diatomite into cement mortar. The excellent tensile & bending reinforcement efficiency of cellulose fiber and void filling ability of diatomite proved to be suppressing cracks of cement. And diatomite seems to improve moisture-protection efficiency of cement mortar because of its high water absorption ratio and slow drying speed.

  • PDF

Development of an Automatic Fog Water Collector (자동 안개 채취기 개발)

  • Lee, Seung-Kew;Kim, Il-Hwan
    • Journal of Industrial Technology
    • /
    • v.20 no.B
    • /
    • pp.183-188
    • /
    • 2000
  • In this paper, we present a development of automatic fog water collector that operates during fog events. This collector consists of fraction collectors, a wind hall and a fog sensor. When a fog event is begin, then the fog sensor would judge whether it is a fog or not. If a fog is detected, the fog would be gathered by air suction fans, At the same time, the wind direction, the wind velocity, the atmospheric temperature and pressure would be measured and record simultaneously. We are also developing a wireless communication system for the remote control and data analysis to collect, store and process data collected in the automatic fog water collector.

  • PDF

Evaluation of Anticorrosive Performance of Organic Coatings Subjected to Cyclic Wet-dry Exposure (흡 .탈수 반복 환경하에서의 유기도막의 방식성 평가)

  • 박진환;이근대;전호환
    • Journal of Ocean Engineering and Technology
    • /
    • v.18 no.1
    • /
    • pp.75-79
    • /
    • 2004
  • Organic coatings are widely used to control of the corrosion of a steel structure. The water in coatings may cause the coatings to swell, leading to the degradation of the coatings. In addition, water affects the permeation of oxygen and other corrosive agents, and consequently, the presence of such substances at coating-metal interface promotes corrosion of the metal substrate. In this study, the anticorrosive properties of 4 types of coating, such as epoxy-epoxy, epoxy-urethane, urethane-epoxy, urethane-urethane, were evaluated. The evaluation tests were conducted under cyclic water-absorption/desorption conditions, consisting of alternative exposure to diluted 0.001M-LiCl(a$H_2O$≒1) and concentrated 10M-LiCl(a$H_2O$≒0.15). The anticorrosive performance of coatings was found to decrease in the order of urethane-urethane > urethane-epoxy > epoxy-epoxy coating.

Study on the Suitability Selection for Construction of Seaweed Bed in Sewage Water Ocean Outfall Area (해양방류수역에서 해조장 조성적지 선정 연구)

  • SHIN, Bong-Kyun;CHOI, Chang-Geun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.4
    • /
    • pp.1021-1030
    • /
    • 2015
  • For the water quality improvement in the ocean outfall area of sewage treatment plant, this study tried to control the water quality of outfall area using the biofilter method through seaweeds, a way of ecological engineering treatment that is applicable in the marine ecosystem. Therefore, this research made an attempt the main factors necessary for creating seaweed bed to improve water quality in the outfall area of sewage treatment plant, and the results are as follows. In the case of making the seaweed bed in the ocean outfall area of sewage treatment plant, Habitat Suitability Index of Ecklonia cava per all survey points, considered physical and physico-chemical factors in 5~10 meters below sea level, was 50~93% (average 80%), so this seaweed, Ecklonia cava, was suitable for making the seaweed bed.

Effects of pH, Alkalinity, Chloride Ion on the Copper Pipe Corrosion (동관에서 pH, 알칼리도, 염소이온이 부식에 미치는 영향)

  • Jo, Kwan-Hyung;Kim, Sun-Il;Woo, Dal-Sik
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.1 s.94
    • /
    • pp.43-48
    • /
    • 2007
  • This study investigated the effects of pH, alkalinity, and chlorine ion which are important water quality impact factors to the corrosion in the simulated distribution system where the copper pipe is affixed. The result shows that pitting index was increased as the alkalinity and chloride ion increase in the distilled water, but there was no relation to pH. Actually the uniform corrosion rate was decreased as the pH increase with the laboratory tap water. In conclusion, it is necessary to control the pH which stands above minimum 7.5 to prevent pitting corrosion in the copper pipe. Consequently, comprehensive research about the effect of lime soda($Ca(OH)_2$) which was used as a coagulation additive in the water treatment plant to pipe corrosion must be accomplished additionally.

흡.탈수 반복 환경에 있어서 유기도막의 방식성 평가

  • Park, Jin-Hwan;Lee, Geun-Dae;Jeon, Ho-Hwan
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.262-268
    • /
    • 2003
  • Organic coatings are widely used to control the corrosion of steel structure. The water in coatings may cause swelling or solvation of coatings, leading to the degradation of coatings. In addition, water affects the permeation of oxygen and other corrosive agents, and consequently the presence of such substances at coating-metal interface promotes corrosion of metal substrate. In this study, the anticorrosive properties of 4 types of coating, such as epoxy-epoxy, epoxy-urethane, urethane-epoxy, urethane-urethane, were evaluated. The evaluation tests were carried out under cyclic water-absorption/desorption conditions, consisting of alternative exposure to diluted 0.001M-LiCl($a_{1120}{\fallingdotseq}1$) and concentrated l0M-LiCl($a_{1120}{\fallingdotseq}0.05$). The anticorrosive performances of coatings were found to decrease in the order of urethane-urethane> urethane-epoxy> epoxy-epoxy coating.

  • PDF

A Study on the Realization of the High Efficiency LCD Photoresist Removal Technology (고효율 LCD 감광막 제거기술 구현 연구)

  • Son, Young-Su;Ham, Sang-Yong;Kim, Byoung-Inn;Lee, Sung-Hwee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.11
    • /
    • pp.977-982
    • /
    • 2007
  • The realization of the photoresist(PR) removal method with vaporized water and ozone gas mixture has been studied for the LCD TFT array manufacturing. The developed PR stripper uses the water boundary layer control method based on the high concentration ozone production technology. We develop the prototype of PR stripper and experiment to find the optimal process parameter condition like as the ozone gas flow/concentration, process reaction time and thin boundary layer formation. As a results, we realize the LCD PR strip rate over the 0.4 ${\mu}m/min$ and this PR removal rate is more than 5 times higher than the conventional immersion type ozonized water process.