• Title/Summary/Keyword: wastewater management

Search Result 564, Processing Time 0.021 seconds

Synthesis of Nanoscale Zerovalent Iron Particle and Its Application to Cr(VI) Removal from Aqueous Solutions

  • Awad, Yasser M.;Abdelhafez, Ahmed A.;Ahmad, Mahtab;Lee, Sang-Soo;Kim, Rog-Young;Sung, Jwa-Kyung;Ok, Yong-Sik
    • Korean Journal of Environmental Agriculture
    • /
    • v.29 no.4
    • /
    • pp.402-407
    • /
    • 2010
  • Zerovalent iron (ZVI) is one of the most commonly used metallic reducing agents for the treatment of toxic contaminants in wastewater. Traditional ZVIs are less effective than nanoscale ZVI (nZVI) due to prolonged reaction time. However, the reactivity can be significantly increased by reducing the size of ZVI particles to nanoscale. In this study, nZVI particles were synthesized under laboratory condition and their efficiency in removing hexavalent chromium (Cr(VI)) from aqueous solutions were compared with commercially available ZVI particles. The results showed that the synthesized nZVI particles (SnZVI) reduced >99% of Cr(VI) at the application rate of 0.2% (w/v), while commercial nZVI (CnZVI) particles resulted in 59.6% removal of Cr(VI) at the same application rate. Scanning electron micrographs (SEM) and energy dispersive spectra (EDS) of the nZVI particles revealed the formation of Fe-Cr hydroxide complex after reaction. Overall, the SnZVI particles can be used in treating chromium contaminated wastewater.

Selection Criteria of Optimal Total Phosphorus Models for Lake Eutrophication Predictions(II) (호수(湖水)의 부영양화(富營養化) 예측(豫測)을 위(爲)한 적정(適正) 총린(總燐) 모형(模型)의 선정(選定) 기준(基準)에 관(關)한 연구(硏究)(II))

  • Seo, Dong-il
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.8 no.1
    • /
    • pp.9-17
    • /
    • 1994
  • The study of lake pollution problems is often related to the dynamic behavior of phosphorus. Several phosphorus models are available that may be suitable to study these problems. Depending on the the management objectives and data availability, some models may be more appropriate than others. Criteria are defined to help modelers choose the most appropriate total phosphorus models for different lakes. These criteria consider in-lake processes such as sediment feedback, stratification, and algal uptake and recycle.

  • PDF

Study on the characteristics of night flow components for leakage management in district metered area (배수구역별 누수관리를 위한 야간유량성분 특성연구)

  • Koo, Ja-Yong;Jang, Kwang-Ho;Kim, Min-Cheol
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.6
    • /
    • pp.871-879
    • /
    • 2009
  • The Korea has high population density, so the precipitation per capita is only one tenth to world average. The water resource in Korea is insufficient. But the leakage in the water distribution system is about 25%, and it is lower than other countries where water utilities are managed well. The pipelines' management also is getting worse because the leakage in the pipelines lower the ground density surrounding pipes. So, managing the leakage in the water distribution system is very important in the view of increasing the water resources and doing the efficient management of the pipeline system. Accordingly this study aimed to conduct a cause-analysis with scientific approaches considering key local factor related to water loss of distribution system and derive better performance indicators which are able to evaluate the real state of water loss management reasonably. Also this research aimed to develop a methodology capable of judging condition of infrastructure of water distribution system.

Adaptive Management of Water Supply Systems to Deal with Climate Changes: A Gwangdong Dam Case Study (기후 변화 대응을 위한 상수도 시설 적응형 관리의 필요성: 2008-2009 광동댐 취수 제한 사례 연구)

  • Lee, Sangeun;Choi, Dongjin;Park, Heekyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.583-598
    • /
    • 2009
  • From the engineering standpoint, this study puts a special emphasis on application of adaptive management. To do this, we analyze the recent issue about water scarcity of the Gwangdong dam. Using the system dynamics model, we defined the system including water balance in the dam, dam manager's operation rules, regional water supply and local water distribution, and customer damage. It was expected that the model is useful to explain the real case, and also water scarcity of Gwangdong led to total damage of about 2.56 billion won, mainly to customers in the Taebaeck city. Two adaptive management options (i.e., optimal allocation of limited water resources, and early control of dam storage) were applied to the model in order to examine whether adaptive management is effective to mitigate the damage, it is concluded that the case study could largely reduce or entirely avoid the damage with adaptive engineering options.

Development of Benchmark Index of LoS for Asset Management of Water Treatment Facilities (정수시설 자산관리 LoS분석 벤치마크지수 개발)

  • Nam, Youngwook;Hyun, Inhwan;Lee, Chulsung;Chun, Mingyu;Kim, Mincheol;Kim, Dooil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.6
    • /
    • pp.667-683
    • /
    • 2015
  • Since aged water treatment facilities could threaten the sustainable water supply, asset management system has been adopted for their systematic management. Level of Service(LoS) is one of critical components of asset management and could be quantified through benchmark index(BMI). Water supplier could estimate consumer's satisfaction and their performance through BMI to improve the LoS. We developed BMI for water treatment facilities from customer's satisfaction survey. BMI, represented with the Total Service Score(TSS), was assessed with water quality, water pressure, taste and odor, water rate, and service quality with weighing factors. BMI could, further, be used to assist the analysis of the life cycle cost to increase the unit of LoS.

Cost benefit analysis of introducing domestic food waste disposers on waste and sewage management systems (가정 내 주방용 디스포저 도입에 따른 사회적 비용편익 분석)

  • Ahn, Jong-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.4
    • /
    • pp.513-520
    • /
    • 2012
  • The use of food waste disposers (FWDs) can be an emerging option to manage organic food wastes in municipal sewage system. The cost-benefit analysis (CBA) of introducing domestic FDWs is conducted to access the allowable disposer market price and the economic impact on food waste management from conventional solid waste management system. If the convenience value of 10,000 won/month is taken into consideration based on survey results, the introduction of FDWs can lead to net economic benefits, allowing the capital cost of disposer up to 1,000,000 won/unit. Without the consideration of convenience value, the introduction of FWDs becomes profitable if the capital cost of disposer is less than 50,000 won/unit. In case that the value of convenience is more than 7,000 won/month, the reduction of food waste management cost is not valid for the introduction of FWDs to be non-profitable. However, if environmental externalities are considered, the proposed system could become breakeven with the cost of food waste management decreases by 54 % (60,000 won per ton).

The improvement of sewerage fee imposition system for efficient rainwater management (효율적 빗물관리를 위한 하수도 요금체계 개편 방안)

  • Park, Kyoo-Hong;Kang, Byong-Jun;Park, Joo-Yang;Park, Wan-Kyu;Kim, Sung-Tae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.5
    • /
    • pp.517-527
    • /
    • 2014
  • As sewer flooding frequents due to localized and concentrated stormwater and increased non-permeable surface area after urbanization, building cities with sound water recycle and accordingly efficient management of rainwater is demanded. To do this, the existing sewage (including rainwater) fee imposition system should be philosophically evaluated. This study presents problematic issues of the existing domestic sewage fee imposition system considering the principle of sharing costs on the service of sewage and rainwater collection and treatment. Four methods to improve the existing sewage fee imposition system are suggested: 1) imposing stormwater fee according to Polluter Pays Principle, 2) clarification of the share of public sector, 3) reducing or exempting the sewerage fee for inhabitants reducing urban runoff by constructing their own rainwater management facilities, 4) imposing charge for discharging rainwater to sewers due to new development action. Short, mid, or long term planning for rainwater management is recommended considering the situation of each municipality.

Study on occurrence and management of organic micropollutants in sewer systems (국내·외 하수도시설 미량유기물질의 발생 특성 및 관리체계에 대한 이해)

  • Jeong, Dong-Hwan;Ham, Sang-Yee;Lee, Wonseok;Chung, Hyenmi;Kim, Hyunook
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.551-566
    • /
    • 2017
  • As the modern society is rapidly developing and people become affluent in materials, many new chemical compounds in different forms of products (e.g., antibiotics, pesticides, detergents, personal care products and plastic goods) are produced, used, and disposed of to the environments. Some of them are persistently having a harmful impact on the environment and mimicking endocrine properties; in general they are present in the environment at low concentrations, so they are called organic pollutants. These organic micropollutants flow to sewage treatment plants via different routes. In this study, the generation characteristics, exposure pathways, detection levels, and environmental impacts of organic micropollutants were critically reviewed. In addition, currently available risk assessment methods and management systems for the compounds were reviewed. The United States Environmental Protection Agency (US EPA), for example, has monitored organic micropollutants and set the monitoring and management of some of the compounds as a priority. To effectively manage organic micropollutants in sewer systems, therefore, we should first monitor organic micropollutants of potential concern and then make a watch list of specific substances systematically, as described in guidelines on listing water pollutants in industrial wastewater.

Development of GIS Information System for Agricultural Reuse of Effluent (하수처리수의 농업용수 재이용 정보 관리시스템 개발)

  • Kim, Hae-Do;Lee, Kwang-Ya;Chung, Kwang-Kun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.535-539
    • /
    • 2006
  • GIS-based integrated management system was developed for the treated wastewater to be reused as agricultural water. The major scopes of this research includes developing different types of system such as connecting data of wastewater treatment plants to data of hydraulic structures and paddy field ; separating spatial data into the watershed boundary and the agricultural water boundary ; and estimating applicable site for reuse. This system can enable to provide more scientific support to manage information of effluent and agricultural data utilizing GIS techniques.

  • PDF

Abundances of triclosan-degrading microorganisms in activated sludge systems

  • Lee, Do Gyun;Chu, Kung-Hui
    • Environmental Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.105-109
    • /
    • 2015
  • Triclosan is a synthetic antimicrobial agent used in numerous industrial and personal care products. Triclosan collected in wastewater treatment plants can be biodegraded up to 80%. However, little is studied about the abundances of known triclosan-degrading bacteria in activated sludge systems. A previous study reported that Sphingopyxis strain KCY1 isolated from activate sludge can cometabolically degrade triclosan. Recently, a quantitative PCR (qPCR) assay specific to strain KCY1 has been developed. Thus, this study investigated the abundance of strain KCY1 in three different activated sludge wastewater treatments using a qPCR assay. Additionally, ammonia-oxidizing bacteria (AOB), known as triclosan-degraders, and amoA gene were quantified. Strain KCY1 were detected in activated sludge samples from three different wastewater treatment plants. The concentrations of strain KCY1 and AOB were on the order of $10^5-10^6$ gene copies/mL, while amoA gene concentration was on the order of $10^4$ gene copies/mL.