• 제목/요약/키워드: wall pressure fluctuation

검색결과 51건 처리시간 0.02초

모따기된 전향계단에 부딪치는 와류에 의한 비정상 벽면압력 변동 (Unsteady Wall Pressure Fluctuation Generated from the Impinging Vortex on the Chamfered Forward Step)

  • 유기완;이준신
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.312-317
    • /
    • 2001
  • Modifying effects of the rectangular forward step for suppressing the unsteady pressure fluctuation during interaction between the upstream vortical flow with the edge are studied numerically. The vortical flow is modeled by a point vortex, and the unsteady pressure coefficient is obtained from the velocity and the potential field. To investigate the effects of the edge shape the rectangular forward step is chamfered with various angles. Calculation show that the pressure peaks become decreased by increasing the vortex height as well as the chamfering angle. The pressure amplitudes are very sensitive to the change of the initial vortex height. From this study we can find out that the chamfered edge has two effects; the one is that it suppresses the pressure amplitude generated from the edge, and the other is that it decreases the time variation of unsteady pressure fluctuation. These modifying concepts can be applied to attenuate the self-sustained oscillation mechanism at the open cavity flow.

  • PDF

평판 난류경계층에서의 벽 압력섭동에 대한 실험적 연구 (Experimental Study on Wall Pressure Fluctuations in the Turbulent Boundary Layer on a Flat-Plate)

  • 이승배;김휘중
    • 대한기계학회논문집B
    • /
    • 제23권6호
    • /
    • pp.722-733
    • /
    • 1999
  • The wall pressure fluctuations of a turbulent boundary layer over a flat plate have been investigated in an anechoic wind tunnel facility. The anechoic wind tunnel consists of acoustically-lined duct, muffler, and splitter-type silencer for noise suppression and vanes for reducing head losses involved. To improve spectra characteristics in high frequency range, a 1/8" pressure-type microphone sensor, which has a pin-holed cap of various diameters, was employed in this experiment. It was shown that the pin-holed microphone sensor with a dimensionless diameter $d^+$ of 7.1 resolved the high frequency pressure fluctuations most effectively among ones with various pin-hole diameters. The measured wall pressure spectra in terms of three types of scaling parameters were in good agreement with other experimental and numerical results. The pressure events of high amplitude were found to contribute to total fluctuating pressure energies in the turbulent boundary layer significantly and supposed to radiate to the far-field effectively.

Effects of Asymmetric Airway Inertance on Mean Lung Volume During High Frequency Ventilation(HFV)

  • Cha, Eun-Jong
    • 대한의용생체공학회:의공학회지
    • /
    • 제11권2호
    • /
    • pp.203-208
    • /
    • 1990
  • A possible asymmetry in airway inertance was modeled based on previously reported radiographic visualization data of the airway wall fluctuation in intact dogs. Effects of asymmetric Inertance on mean lung volume during high frequency ventilation (HFV) were evaluated in terms of mean inertive pressure drop across the airways. It was found that a negligible inertlve pressure drop was expected ($<1{\;}cmH_20$) in normal subjects, while a sig- nificant rise in mean alveolar pressure compared to mean mouth pressure by approximately $3{\;}cmH_20$ was resulted for about 40% airway fluctuation representing bronchoconstriction state by Histamine induction. These results demonstrate that asymmetric Inertance could lead patients with airway diseases to a significant lung hyperinflation (LHI), and bronchodilation treatment is recommended prior to applying HFV to prevent those patients from a possible barotrauma.

  • PDF

비균질 수정을 사용한 타원완화모형 개발 (Development of Elliptic Relaxation Model With The Inhomogeneous Correction)

  • 전건호;최영돈;신종근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.815-818
    • /
    • 2002
  • The elliptic relaxation model(ERM) with the inhomogeneous correction intermediate between near wall with and far from the wall. The source of the ERM usually was appled quasi-homogeneous pressure-strain correlation in homogeneous situations. This formulation was easily applied to the linear model or non-linear pressure-strain model. It is observed that the boundary conditions of the relaxation operator dominate the homogeneous pressure-strain model in the near wall region. While looking at high-Reynolds number flows, it was found necessary to modify the effect of the relaxation operator throughout the log region by accounting for gradients of the flatness variable and turbulent length scales. These effects are kinematic blocking of the wall normal velocity fluctuation and pressure reflections from the surface. This model is wall distances and unit vectors which make the model applicable to flows boundary by a complex geometry. Inhomogeneous correction model is computed inertial and non-inertial channel flow These are compared DNS(Kim et at., Kristofffrsen & Andersson) for channel flow. The present model could be predicted well for rotating flows.

  • PDF

천이 경계층 유동의 벽면 변동 압력에 관한 실험적 연구 (Experimental Study of Wall Pressure Fluctuations in the Regions of Flow Transition)

  • 홍진숙;전재진;김상윤;신구균
    • 한국소음진동공학회논문집
    • /
    • 제12권4호
    • /
    • pp.280-286
    • /
    • 2002
  • It has been long suspected that the transition region may give rise to local pressure fluctuations and radiated sound that are different from those created by the fully-developed turbulent boundary layer at equivalent Reynolds number. Experimental investigation described in this paper concerns the characteristics of pressure fluctuations at the transition. Flush-mounted microphones and hot wires are used to measure the pressure fluctuations and local flow velocities within the boundary layer in the low noise wind tunnel. From this experiment we could observe the spatial and temporal development process of T-S wave using Wigner-Ville method and find the relations between the characteristic frequency of T-S wave and free stream velocity and the boundary layer thickness based on nondimensional pressure spectra scaled on outer variables.

Unsteady Analysis of Impeller-Volute Interaction in Centrifugal Pump

  • Cheah, Kean Wee;Lee, Thong See;Winoto, Sonny H.
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권3호
    • /
    • pp.349-359
    • /
    • 2011
  • An unsteady numerical analysis has been carried out to study the strong impeller volute interaction of a centrifugal pump with six backward swept blades shrouded impeller. The numerical analysis is done by solving the three-dimensional Reynolds Averaged Navier-Stokes codes with standard k-${\varepsilon}$ two-equations turbulence model and wall regions are modeled with a scalable log-law wall function. The flow within the impeller passage is very smooth and following the curvature of the blade in stream-wise direction. However, the analysis shows that there is a recirculation zone near the leading edge even at design point. When the flow is discharged into volute casing circumferentially from the impeller outlet, the high velocity flow is severely distorted and formed a spiraling vortex flow within the volute casing. A spatial and temporal wake flow core development is captured dynamically and shows how the wake core diffuses. Near volute tongue region, the impeller/volute tongue strong interaction is observed based on the periodically fluctuating pressure at outlet. The results of existing analysis also proved that the pressure fluctuation periodically is due to the position of impeller blade relative to tongue.

철도터널 통풍공의 공기역학적 성능에 대한 연구 (The study for the aerodynamic effects of air-shafts in the railway tunnel)

  • 김동현;강부병;신민호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.341-348
    • /
    • 2001
  • The purpose of present study is to investigate for reducing pressure fluctuations in the case of installing the air-shafts on the side wall of the tunnel with small cross-sectional area on conventional line. Experiments were performed with a 1/61-scale moving model rig for the tunnel of 0.764 km length in the condition of tunnel cross-section area of $28 m^2$. According to the results, the maximum pressure fluctuation is reduced by 45 % for 19 air-shafts. This results have the speed-up effects of about 33.4 km/h for the train running in tunnel.

  • PDF

재생냉각 연소기 연소시험의 연소안정성 분석 (Combustion Stability Analysis on Hot-firing Test Results of Regenerative Cooling Combustion Chamber)

  • 안규복;임병직;이광진;한영민;최환석
    • 한국추진공학회지
    • /
    • 제13권5호
    • /
    • pp.15-20
    • /
    • 2009
  • 분사기 배열 및 벽면 냉각 방식이 다르게 설계된 30톤급 재생냉각 두 연소기에 대한 연소시험이 수행되었다. 본 논문에서는 연소시험 결과 중 연소안정성에 대한 내용을 분석, 제시하였다. 연소안정성 평가를 위해 압력 섭동의 크기 및 SRT 결과를 검토하였으며, 두 연소기 모두 연소안정성 측면에서 매우 만족스러운 결과를 얻을 수 있었다. 압력 섭동의 RMS 값은 연소실 압력 대비 3% 미만의 값을 나타내었으며, SRT 결과에서도 외부 가진에 의한 압력 peak의 감쇠시간은 기준 감쇠시간의 10% 정도로 짧게 나타났다. 막냉각이 적용된 연소기의 경우 벽면 냉각용 분사기가 최외곽 열에 배치된 연소기에 비해 압력 섭동의 RMS 값이 감소하는 결과를 보였다.

Digital Recording Device를 ol용한 회전중인 블레이드 표면의 압력섭동 측정 (Measurement of Surface Pressure Fluctuations on a Rotating Blade Using a Digital Recording Device)

  • 윤정식;강웅;성형진
    • 대한기계학회논문집B
    • /
    • 제29권10호
    • /
    • pp.1119-1129
    • /
    • 2005
  • A new measurement system of wall pressure fluctuations on a rotating machinery, composed of digital recording device, was developed and evaluated. The small-sized digital recording device was attached on the rotating machinery and then was detached for data reduction. In order to obtain the system transfer function of the digital recording system, a dynamic calibration was performed utilizing the signal from a 1/8 inch B&K microphone as input. The time history of the unsteady pressure was then reconstructed from the output of the sensor by using this transfer function. The reconstructed pressure signals showed good agreement with the reference signal in both temporal and spectral sense. This sensor was then used to measure the wall pressure fluctuations on a rotating blade. An array of microphones were installed on the blade in the circumferential and radial directions. Various statistical moments were obtained from the measurement data set. Comparison of these quantities with the existing studies demonstrated satisfactory agreement. These tests give credence to the relevance and reliability of this device for applications in more complicated turbulent rotating machineries.

곡면상에 설치된 열린 공동을 지나는 천음속/초음속 유동에 관한 연구 (II) - 비정상 유동의 특성 - (Investigation of Transonic and Supersonic Flows over an Open Cavity Mounted on Curved Wall (II) - Unsteady Flow Characteristics -)

  • 예아란;;김희동
    • 대한기계학회논문집B
    • /
    • 제39권6호
    • /
    • pp.477-483
    • /
    • 2015
  • 공동유동에 관한 연구는 공동시스템에서 발생하는 소음/진동 문제로 인하여 많은 연구가 이루어졌으며, 현제 항공우주 산업의 급속한 발전과 더불어 다양한 공학적 장치에 적용되고 있다. 하지만, 실제 공학적 응용에서 많이 적용되는 곡면 벽상에 설치한 공동유동에 관한 연구에 대해서는 거의 수행되지 않았다. 본 연구에서는 곡면벽상에 설치한 공동유동의 특성을 조사하기 위해 수치계산을 수행하였으며, 곡면의 곡률 반경의 비(L/R) 및 입구 유동의 마하수를 변화시켜, 천음속/초음속 공동유동에서 발생하는 압력진동을 조사하였다. 그 결과 곡면에 부착된 공동유동의 경우 와류의 상호작용으로 인한 압력 교란을 완화시켰으나, 압력 진동의 진폭을 증가시켰으며, 또한 마하수가 증가함에 따라 압력 진동의 진폭이 증가하였다. 주파수 분석 결과, 곡관의 무차원 진동수는 직관에 비해 낮은 값이 측정되었으며, 또한 Rossiter의 실험값에 비해 낮은 값을 가졌다.