• Title/Summary/Keyword: wall design

Search Result 2,979, Processing Time 0.026 seconds

A Study on Practices and Troubles of Reinforced Soil Wall (국내 보강토 옹벽 적용 현황 및 문제점 조사 연구)

  • Park, Jong-Kwon;Lee, Kwang-Wu
    • Journal of the Korean Geosynthetics Society
    • /
    • v.11 no.1
    • /
    • pp.65-75
    • /
    • 2012
  • Since the modem reinforced soil wall technology was introduced in domestic civil engineering society in the year 1980, the reinforced soil walls have been extensively used because these technologies have advantages such as economical efficiency, graceful appearance, and easy construction. This paper describes the application of reinforced soil wall, design criteria, and construction problems. Many cases of troubles, which include a severe deformation of facing, cracks of facing block, overall sliding failure and so on, have been reported. Inappropriate design and construction management mainly induce these problems. The technological level of design and quantity control for reinforced soil wall is not sufficiently supported to cope with the growth quantity of reinforced soil wall construction market and the increasing number of construction companies. The unified standard design and construction criteria of reinforced soil wall should be established with the detail consideration of overall performance and stability. The quality control of design and construction, and cost of construction must be seriously executed to construct a high quality of reinforced soil wall.

Problem of Evaluation Methods on the Wall Facing-Geosynthetics Connection Strength and Its Improvement (전면 벽체-보강재 연결강도 평가방법의 문제점 및 개선 방향)

  • Hong, Ki-Kwon;Shin, Ju-Oek;Han, Jung-Geun;Cho, Sam-Deok;Lee, Kwang-Wu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.184-195
    • /
    • 2008
  • The use of geosynthetics for the reinforced earth wall system has been increasing rapidly for a number of years. The connection strength between wall facing and geosynthetics should be evaluated in the design of geosynthetics. However, the connection strength is not often evaluate, exactly, and it causes problems such as deformation of the wall facing, local failure of the reinforced earth wall system, conservative design and so on. Therefore, the connection strength in the design of geosynthetics should be applied evaluation result by reasonable method. This study is evaluated connection strength using the typical design method, NCMA(1997) and FHWA(1996), in the field case. Then the results compared with the evaluation results of connection strength, which is suggested by Soong & Koener(1997). The analysis results confirmed that the connection strength for the design of geosynthetics should be evaluate using reasonable method with considering various factor, such as safety factor, installation and importance of construction.

  • PDF

Test on the anchoring components of steel shear keys in precast shear walls

  • Shen, Shao-Dong;Pan, Peng;Li, Wen-Feng;Miao, Qi-Song;Gong, Run-Hua
    • Smart Structures and Systems
    • /
    • v.24 no.6
    • /
    • pp.783-791
    • /
    • 2019
  • Prefabricated reinforced-concrete shear walls are used extensively in building structures because they are convenient to construct and environmentally sustainable. To make large walls easier to transport, they are divided into smaller segments and then assembled at the construction site using a variety of connection methods. The present paper proposes a precast shear wall assembled using steel shear keys, wherein the shear keys are fixed on the embedded steel plates of adjacent wall segments by combined plug and fillet welding. The anchoring strength of shear keys is known to affect the mechanical properties of the wall segments. Loading tests were therefore performed to observe the behavior of precast shear wall specimens with different anchoring components for shear keys. The specimen with insufficient strength of anchoring components was found to have reduced stiffness and lateral resistance. Conversely, an extremely high anchoring strength led to a short-column effect at the base of the wall segments and low deformation ability. Finally, for practical engineering purposes, a design approach involving the safety coefficient of anchoring components for steel shear keys is suggested.

Design for High Gain Spiral Antenna by Added Conical Cavity Wall

  • Jeong, Jae-Hwan;Min, Kyeong-Sik;Kim, In-Hwan
    • Journal of electromagnetic engineering and science
    • /
    • v.13 no.3
    • /
    • pp.165-172
    • /
    • 2013
  • This paper describes a design for a spiral antenna with a conical wall to obtain the high gain. The gain and the axial ratio of the spiral antenna were improved by a new design that included a conical wall and an optimized Archimedean slit on the ground plane in a conventional antenna with a circular cavity wall and a 4.5-turn slit. A gain improvement of 9.5 dBi higher and a good axial ratio of 1.9 dB lower were measured by the added conical wall and the newly designed slit from the current distribution control on the ground plane, respectively. The measured return loss, gain and axial ratio of the proposed antenna showed a good agreement with the simulated results. The proposed antenna will be applied to a non-linear junction detector system.

Troubles and Countermeasures of Geogrid-Reinforced Earth Wall (지오그리드 보강토 옹벽의 설계/시공에 따른 문제점과 대책방안)

  • 조삼덕
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.10a
    • /
    • pp.315-321
    • /
    • 2001
  • Since 1984, block-type reinforced earth wall with geogrid reinforcement has been widely used for retaining wall applications till now in Korea. The use of geogrid as a reinforcement in the reinforced earth wall is steadily increased in an amount over 1,500,000㎡ in a year However, still need exists that some problems in design and construction practices should be made to review, Therefore, this paper reviewed reasonable criteria for selection of backfills, design details considering the effect of the upper soil slope on reinforced earth wall, horizontal displacement of facing block during compaction, and the damage of geogrid reinforcements on the edge part of facing block. Finally, alternative methods of measures on those problems are proposed.

  • PDF

Current State and Technical Development of Geosynthetics-Reinforced Earth Wall (토목섬유 보강토옹벽의 기술현황 및 개발동향)

  • Cho, Sam-Deok;Lee, Kwang-Wu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.141-157
    • /
    • 2008
  • Since 1984, block-type reinforced earth wall with geogrid reinforcement has been widely used for retaining wall applications till now in Korea. The use of geogrid as a reinforcement in the reinforced earth wall is steadily increased in an amount over $6,500,000m^2$ in a year. However, still need exists that some problems in design and construction practices should be made to review. Therefore, this paper reviewed current state and development items of geosynthetics-reinforced earth wall technology on design and construction point of view.

  • PDF

Stiffness and Strength Evaluation of the CFRP Display Wall mount Arm (CFRP 디스플레이 월마운트암의 강성과 구조강도의 평가)

  • Jang, Woongeun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.2
    • /
    • pp.147-154
    • /
    • 2019
  • Recently as flat display panels are getting narrower, TV wall mounts also become slimmer for interior design issue. In this study CFRP(Carbon Fiber Reinforced Plastic) was used for TV wall mount to satisfy slim arm design along with enough strength and low weight. The 16 staking sequences was made with orthogonal array to reduce experimental cases. Strength analysis of the TV wall mount arm made of CFRP laminate was studied on condition of staking sequences using FEA(Finite Element Analysis) and stiffness and strength of those cases were evaluated using deflection and Tsai-Wu's Failure criterion. The result showed that [$-45^{\circ}/90^{\circ}/45^{\circ}/0^{\circ}/-45^{\circ}$] lay up case was suitable for the wall mount arm staking design from the criteria of deflection and Tsai-Wu's Failure Index.

A Study on the Vertical Garden Design for Indoor Space - Focused on Green Wall in Lobby Space - (실내 벽면녹화의 공간 계획 경향에 관한 연구 - 로비공간의 적용 사례를 중심으로 -)

  • Yang, Sae-Yi;Cho, Sung-Ik
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.3
    • /
    • pp.33-42
    • /
    • 2013
  • The purpose of this study was to analyze the design trend of the vertical garden design in the indoor space through the examples of green wall in the lobby space. For the analysis, this study looks into the 'Guide for the Building Greening System' to understand the technical consideration for the green wall. After that, the key design elements was drawn from existing green walls through the literature review and field survey and field-survey. The study picked six green walls which was completed after 2000 in the lobby space in Seoul. The major findings of this study were as follows: First, the design factors mainly depend on the plant selection, which leads to the outlook and texture of the vertical walls. The texture is expressed by the two-dimensional or three-dimensional planting methods which is related to the selection of plant species. Second, the vertical walls in the lobby area should be planned for the function of space which could be transition, human traffic, mood and attraction. Third, the vertical wall should be integrated with the surroundings in order to reinforces the dynamic or static space experience.

A Study of the Wall Environmental Design at Subway Station -For the Focus on Pusan Subway Station- (지하철역의 벽면 환경디자인에 관한 연구 -부산 지하철역을 중심으로-)

  • 박시환;장경수
    • Korean Institute of Interior Design Journal
    • /
    • no.10
    • /
    • pp.28-33
    • /
    • 1997
  • The primary purpose of this thesis is to offer users for the better surroundings in planning subway wall design through analyzing the Wall Environmental Design at Subway Statiov. As the urban circumstances were developed by the economic growth, the new city plan, re-development evoked the radical changes in the urban circumstances. In processing the industrialization and urban surroundings. This range has enlargened and provided the localism, the function, the purpose with the visual informations. The method of this paper was the spot survey simultaneously the photographing of the mould's size. theme, colour, material, compossitiov. In conclusion, concerning about the artificial and subterranean space, the Wall Environmental Design at Subway Station needs more practial approach in the using the space.

  • PDF

Design Charts and Simplified Formulae for Anchored Sheet Pile Wall- Using Equivalent Beam Analysis for Fixed End Supported Wall - (앵커식 널말뚝벽의 설계용 도표와 간편식- 고정지지 널말뚝의 등가보 해석을 사용하여 -)

  • 김기웅;원진오;백영식
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.1
    • /
    • pp.19-30
    • /
    • 2000
  • The major design parameters of the anchored sheet-pile wall include the determination of required penetration depth, the force acting on the anchor, and the maximum bending moment in the piling. Blum solved the fixed earth supported wall using the equivalent beam method, assuming that the wall can be separated into upper and lower parts of the point of contraflexure. Design charts help designer by simplifying the design procedure. But they have some difficulties under some Geotechnical and geometrical conditions. For example, the conventional design charts can compute design parameters only when the ground water table exists above the dredge line. In this paper, the design charts which can be used for the ground water table existing under the dredge line are presented. And simplified formulae are developed by regression analysis. It is found that simplified formulae are not only very useful for the practice of design but also they can evaluate the result of numerical methods or design charts.

  • PDF