• Title/Summary/Keyword: wall defect

Search Result 432, Processing Time 0.023 seconds

Thermal and Chemical Quenching Phenomena in a Microscale Combustor (II)- Effects of Physical and Chemical Properties of SiOx(x≤2) Plates on flame Quenching - (마이크로 연소기에서 발생하는 열 소염과 화학 소염 현상 (II)- SiOx(x≤2) 플레이트의 물리, 화학적 성질이 소염에 미치는 영향 -)

  • Kim Kyu-Tae;Lee Dae-Hoon;Kwon Se-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.5 s.248
    • /
    • pp.405-412
    • /
    • 2006
  • In order to realize a stably propagating flame in a narrow channel, flame instabilities resulting from flame-wall interaction should be avoided. In particular flame quenching is a significant issue in micro combustion devices; quenching is caused either by excessive heat loss or by active radical adsorptions at the wall. In this paper, the relative significance of thermal and chemical effects on flame quenching is examined by means of quenching distance measurement. Emphasis is placed on the effects of surface defect density on flame quenching. To investigate chemical quenching phenomenon, thermally grown silicon oxide plates with well-defined defect distribution were prepared. ion implantation technique was used to control defect density, i.e. the number of oxygen vacancies. It has been found that when the surface temperature is under $300^{\circ}C$, the quenching distance is decreased on account of reduced heat loss; as the surface temperature is increased over $300^{\circ}C$, however, quenching distance is increased despite reduced heat loss effect. Such abberant behavior is caused by heterogeneous surface reactions between active radicals and surface defects. The higher defect density, the larger quenching distance. This result means that chemical quenching is governed by radical adsorption that can be parameterized by oxygen vacancy density on the surface.

UNCERTAINTY ANALYSIS OF DATA-BASED MODELS FOR ESTIMATING COLLAPSE MOMENTS OF WALL-THINNED PIPE BENDS AND ELBOWS

  • Kim, Dong-Su;Kim, Ju-Hyun;Na, Man-Gyun;Kim, Jin-Weon
    • Nuclear Engineering and Technology
    • /
    • v.44 no.3
    • /
    • pp.323-330
    • /
    • 2012
  • The development of data-based models requires uncertainty analysis to explain the accuracy of their predictions. In this paper, an uncertainty analysis of the support vector regression (SVR) model, which is a data-based model, was performed because previous research showed that the SVR method accurately estimates the collapse moments of wall-thinned pipe bends and elbows. The uncertainty analysis method used in this study was an analytic uncertainty analysis method, and estimates with a 95% confidence interval were obtained for 370 test data points. From the results, the prediction interval (PI) was very narrow, which means that the predicted values are quite accurate. Therefore, the proposed SVR method can be used effectively to assess and validate the integrity of the wall-thinned pipe bends and elbows.

Use of the Sundt Clip Graft in a Previously Coiled Internal Carotid Artery Blister-Like Aneurysm

  • Cho, Jae Ik;Cho, Jae Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.6
    • /
    • pp.496-499
    • /
    • 2014
  • Owing to the focal wall defect covered with thin fibrous tissues, an aneurysm arising from the dorsal wall of the internal carotid artery (ICA) is difficult to manage either surgically or endovascularly and is often associated with high morbidity and mortality. Unfortunately, the definitive treatment modality of such highly risky aneurysm has not yet been demonstrated. Upon encountering the complex intracranial pathophysiology of such a highly precarious aneurysm, a neurosurgeon would be faced with a challenge to decide on an optimal approach. This is a case of multiple paraclinoid aneurysms including the ICA dorsal wall aneurysm, presented with spontaneous subarachnoid hemorrhage. With respect to treatment, direct clipping with a Sundt graft clip was performed after multiple endovascular interventions had failed. This surgical approach can be a treatment modality for a blood blister-like aneurysm after failed endovascular intervention(s).

Malignant lymphoma [non-Hodgkin`s lymphoma] at left posterior chest wall (흉벽에 발생한 악성 임파종 [Non-Hodgkin`s lymphoma] 수술 치험 1예)

  • 김송명
    • Journal of Chest Surgery
    • /
    • v.16 no.1
    • /
    • pp.176-182
    • /
    • 1983
  • Malignant lymphoma in chest wall is a rare form of extranodal variety as occasionally localized tumor. The primary site is suggested from rib or soft tissue, but the incidence in rib is higher than soft tissue. The patient, a male, aged 32, noted a swelling and pain over the left lower posterior chest from 3 months prior to admission. Roentgenograms revealed bony destruction in left 9, & 19th ribs posteriorly and associated chest wall mass which was ill defined uncleared margination. Under diagnosis of malignant tumor, the operation was performed and the tumor mass resected widely with en bloc technique than the fascia lata was grafted at chest wall defect. The histology of specimen was disclosed as malignant lymphoma, non-Hodgkin`s diffuse lymphocytic poorly differentiated form. The radio-and chemotherapy were combined post-operatively and the complete remission is acquired.

  • PDF

Surgical Resection of the Aneurysm of the Thoracic Aorta: Report of A Case (흉부대동맥의 동맥류 절제 치험례)

  • 김영태
    • Journal of Chest Surgery
    • /
    • v.6 no.1
    • /
    • pp.51-56
    • /
    • 1973
  • This is one case report of successful resection of the aneurysm of the thoracic aorta, which det-ected by thoractomy unexpectedly, in the Department of Thoracic Surgery, Hanyang University Hospital. The patient was a 34 years old woman and subjective complaints was not related with the aneurysm. Chest film showed a small round hazy shadow in the left margin of the upper posterior mediastinum. A saccular aneurysm located on the descending thoracic aorta, 7cm distal to the left subclavian artery and arouse from the antero-lateral wall of the aorta. Excision of the saccular aneurysm was performed by cross clamping the descending aorta above and below the aneurysm, and then the defect of the aortic wall was closed by aortorrhaphy with continuous suture. Crossclamping time was required 15 minute. Histopathologically, the wall of the aneurysm consisted of all layers of the arterial wall, that is, intima, media and adventitia. Postoperative course was uneventful and aortogram showed good continuity of the blood flow of the entire aorta.

  • PDF

Value of Porous Titanium Alloy Plates for Chest Wall Reconstruction after Resection of Chest Wall Tumors

  • Qi, Yu;Li, Xin;Zhao, Song;Han, Yong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.11
    • /
    • pp.4535-4538
    • /
    • 2014
  • Objective: To explore the value of porous titanium alloy plates for chest wall reconstruction after resection of chest wall tumors. Materials and Methods: A total of 8 patients with chest wall tumors admitted in our hospital from Jan. 2006 to Jan. 2009 were selected and underwent tumor resection, then chest wall repair and reconstruction with porous titanium alloy plates for massive chest wall defects. Results: All patients completed surgery successfully with tumor resection-induced chest wall defects being $6.5{\times}7cm{\sim}12{\times}15.5$ cm in size. Two weeks after chest wall reconstruction, only 1 patient had subcutaneous fluidify which healed itself after pressure bandaging following fluid drainage. Postoperative pathological reports showed 2 patients with costicartilage tumors, 1 with squamous cell carcinoma of lung, 1 with lung adeno-carcinoma, 1 with malignant lymphoma of chest wall, 2 with chest wall metastasis of breast cancers and 1 with chest wall neurofibrosarcoma. All patients had more than 2~5 years of follow-up, during which time 1 patient with breast cancer had surgical treatment due to local recurrence after 7 months and none had chest wall reconstruction associated complications. The mean survival time of patients with malignant tumors was ($37.3{\pm}5.67$) months. Conclusions: Porous titanium alloy plates are safe and effective in the chest wall reconstruction after resection of chest tumors.

Two Portal Approach(Endoscopic Transnasal and Subciliary) in Medial Orbital Wall Fracture (내시경을 이용한 비강내 접근법과 속눈썹밑 절개를 동시에 이용한 안와내벽 재건술)

  • Chang, Hyun;Dhong, Eun-Sang;Won, Chang-Hoon;Yoon, Eul-Sik
    • Archives of Plastic Surgery
    • /
    • v.33 no.5
    • /
    • pp.552-556
    • /
    • 2006
  • Purpose: As the use of computed tomographic scanning spread, the diagnosis of blow-out fractures of the medial orbital wall increased. Conventionally, the surgery of blow-out fractures in medial orbital wall was performed by various approaches with external incision or endoscopic approach. Although the field of orbital surgery has progressed significantly during the last decade, accurate realignment and replacement of component is difficult due to lack of visualization of the fracture site, blind dissection of the orbital wall, and difficulty in insertion of implant. In order to overcome these shortcomings, we explored the use of endoscopic transnasal approach together with subciliary approach. Methods: The entrapped periorbital tissues in the ethmoid sinus were completely reduced endoscopically, and the bone defect of medial orbital wall was reconstructed with $Medpor^{(R)}$ insertion via subciliary approach. This technique was applied to 13 patients who had medial orbital wall fracture. Results: The patients were followed-up for 3 to 24 months with an average of 9 months. The postoperative courses were satisfactory in all cases. Conclusion: The conjunction of endoscopic transnasal and subciliary approach technique seems to produce good results in medial orbital wall fracture.

ASSESSMENT OF WALL-THINNING IN CARBON STEEL PIPE BY USING LASER-GENERATED GUIDED WAVE

  • Kim, Do-Youn;Cho, Youn-Ho;Lee, Joon-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.42 no.5
    • /
    • pp.546-551
    • /
    • 2010
  • The objective of this research is to estimate the crack location and size of a carbon steel pipe by using a laser ultrasound guided wave for the wall thinning evaluation of an elbow. The wall thinning of the carbon steel pipe is one of the most serious problems in nuclear power plants, especially the wall thinning of the carbon steel elbow caused by Flow-Accelerated Corrosion (FAC). Therefore, a non-destructive inspection method of elbow is essential for the nuclear power plants to operate safely. The specimens used in this study were carbon steel elbows, which represented the main elements of real nuclear power plants. The shape of the wall thinning was an oval with a width of 120mm, a length of 80mm, and a depth of 5mm. The L(0,1) and L(0,2) modes variation of the ultrasound guided wave signal is obtained from the response of the laser generation/air-coupled detection ultrasonic hybrid system represent the characteristics of the defect. The trends of these characteristics and signal processing were used to estimate the size and location of wall thinning.

A RADIOGRAPHIC STUDY OF EXPERIMENTALLY PRODUCED BONE DEFECTS IN THE POSTERIOR WALL OF THE MAXILLARY SINUS (상악동 후벽의 실험적 골결손부에 관한 방사선학적 연구)

  • Choi Eui-Hwan;Park Won-Kyl
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.26 no.2
    • /
    • pp.153-163
    • /
    • 1996
  • The purpose of this study was to evaluate the ability of radiographs in detecting experimental bony defect in the posterior wall of the maxillary sinus. For this study, experimentally five skulls were used, the bony defects with a diameter of 5mm were created at different locations in the posterior wall of the right maxillary sinus and the bony defects of 10mm were created at different locations in the posterior wall of th maxillary sinus. Panoramic view, panoramic sinus view, water's view, and computed tomogram were taken and the results analyzed. The obtanined results were as follows: 1. The panoramic view was superior to the panoramic sinus view in detecting the bony defects in the posterior wall of the maxillary sinus. 2. Panoramic view, panoramic sinus view, and waters's view were limitation to the detection of the bony defects in the posterior wall of the maillary sinus. 3. All the bony defects in the posterior wall of the maxillary sinus were excellently visualized on the computed tomogram.

  • PDF

The Effects of Enamel Matrix Derivative and Calcium Sulfate Paste on the Healing of 1-Wall Intrabony Defects in Beagle Dogs (성견 1면 치조골 결손부에서 $Emdogain^{(R)}$$Emdogain^{(R)}$ 및 특수 제조된 Calcium Sulfate Paste 혼합물이 치주조직 치유에 미치는 영향)

  • Choi, Seong-Ho;Kim, Chang-Sung;Suh, Jong-Jin;Kim, Hyun-Young;Kim, Jeong-Hye;Cho, Kyoo-Sung;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.3
    • /
    • pp.539-555
    • /
    • 2000
  • Recently, it was reported that enamel matrix derivative may be beneficial in periodontal regeneration procedures in expectation of promoting new bone and cementum formation. The aim of present study was to evaluate the effect of enamel matrix derivative($Emdogain^?$)and Caso4 sulfate paste in 1-wall intrabony defects in beagle dogs. Surgically created 1-wall intrabony defects were randomly assigned to receive root debridement alone or $Emdogain^{(R)}$ or $Emdogain^{(R)}$ and Caso4. Clinical defect size was 4 X 4mm. The control group was treated with root debridement alone,and Experimental group I was treated with enamel matrix derivative application, and Experimental group II was treated with enamel matrix derivative and Caso4 sulfate paste application,. The healing processes were histologically and histometrically observed after 8 weeks and the results were as follows: 1. The length of junctional epithelium was $0.41{\pm}0.01mm$ in the control group, $0.42{\pm}0.08mm$in the experimental group I and $0.50{\pm}0.13mm$in the experimental group II. 2. The connective tissue adhesion was $0.28{\pm}0.02mm$ in the control group, $0.13{\pm}0.08mm$ in the experimental group I and $0.19{\pm}0.02mm$ in the experimental group II. 3. The new cementum formation was $3.80{\pm}0.06mm$ in the control group, $4.12{\pm}0.43mm$ in the experimental group I and $4.34{\pm}0.71mm$ in the experimental group II. 4. The new bone formation was $1.43{\pm}0.03mm$ in the control group, $1.53{\pm}0.47mm$ in the experimental group I and $2.25{\pm}1.35mm$ in the experimental group II. Although there was limitation to present study, the use of enamel matrix derivative in the treatment of periodontal 1-wall intrabony defect enhanced new cementum and bone formation. Caso4 sulfate paste will be the candidate for carriers to deliver enamel matrix derivative, and so enhance the regenerative potency of enamel matrix derivative.

  • PDF