• 제목/요약/키워드: volume measurement

검색결과 1,621건 처리시간 0.03초

민물말류 군집 생태 연구시 생체량 계산의 의미와 예 (Short Note on Freshwater Algal Biomass Measurements and Significance in Ecological Community Studies)

  • 정상옥
    • ALGAE
    • /
    • 제19권2호
    • /
    • pp.149-151
    • /
    • 2004
  • Freshwater algae make up a very important portion of the autotrophic component of the aquatic food web. Therefore, the study of freshwater algal structure and biomass is central to aquatic ecosystem studies. Due to variations in cell shape and size for each species (or taxon) and survey site, cell abundance (or cell numbers per chosen volume) often leads to misrepresentation of the true importance of some species because of the great differences in size of various algae. Thus, it is necessary to investigate the freshwater algal species of a site in order to calculate the cell volume. Although direct cell counting, species volume measurement, as well as biomass calculation are time-consuming and requiring specialists in taxonomy.

지그비 통신 기반의 근거리 무선 호흡모니터 시스템 (Zigbee Based Wireless Respiration Monitor System)

  • 이인광;김성식;장종찬;김군진;김경아;이태수;차은종
    • 전기학회논문지
    • /
    • 제57권1호
    • /
    • pp.142-147
    • /
    • 2008
  • Abdominal circumference changes due to breathing by the respiratory muscle activity such as diaphragm, which would partially represent the lung volume variation. The present study introduced conductive rubber molded in a cord shape incorporated with a patient's pants. The conductive rubber cord operated as a displacement transducer to measure the lung or abdominal volume changes. Signal extraction circuitry was developed to obtain the volume and its derivative(or the flow) signals followed by wireless transmission based on the Zigbee communication protocol in a size of $65mm{\times}105mm$ easily put in pocket. Breathing frequency was accurately evaluated and breath pattern analysis seemed feasible, since respiratory behaviours such as maximal inspiration and cough were well identified. Remote wireless receiver module also enabled to monitor both volume and flow signals during resting breathing on a PC terminal.

Reach volume의 측정과 로보트 기구학을 이용한 해석적 생성의 비교

  • 기도형;신용탁;강동석;정의승
    • 대한인간공학회:학술대회논문집
    • /
    • 대한인간공학회 1996년도 추계학술대회논문집
    • /
    • pp.232-237
    • /
    • 1996
  • When designing workplaces or arranging controls on panel, devices and controls should be placed within the reach of operator's arm or foot to guarantee effective performances. Most of the existing research on the reach volume were based on measurements of a few subject's arm reach, and limited to Caucasian and Chineses populations, and foot reach and trunk motion have been excluded. Range of human joint motion and that of two degrees of freedom motion are needed to generate reach volume analytically using the sweeping algorithm. Therefore, in this research, range of two degrees of reedom motion was measured, in which 47 college students were participated volumtarily as subjects. Second, new approximate algorithms generating reach volumes were suggested based on the robot kinematics, in which range of two degrees of freedom motion was considered. Our analytically generated reach volume showed statistically reasonable results when compared with that obtained from direct measurement.

  • PDF

대형 크루저 선실의 동절기 온열환경 측정평가 (A Measurement and Evaluation on the Cabins' Thermal Conditions of Large Cruiser in the Winter)

  • 황광일;문태일;박민강;심재건
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.231-232
    • /
    • 2006
  • The purpose of this study is to measure and evaluate the thermal conditions of large cruiser's cabin. As the result of this study, followings are cleared. The air volume supplied to the 2 types of cabins is quite diffenrent. Temperature differences in the Room A which is located A deck and supplied enough air volume is stable all around the cabin. But Room B which is located B deck and supplied comparatively small air volume has temperature distribution problems, like time-dependent differences, vertical differences. To serve more comfort and productivity of Room B, it is strongly recommended to do a T.A.B.(Testing, Adjusting and Balancing) for more air volume and/or to design new air flow path to make air stay longer.

  • PDF

생체조직내에서 반사광을 이용한 확산 상수의 측정에 관한 연구 (A Study on Diffusion Constant Measurement Using Light Reflectance within Biological Tissue)

  • 임현수
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권2호
    • /
    • pp.227-234
    • /
    • 1996
  • This paper is the study of the diffusion constant in order to calculate the percent oxygenation and percent blood volume using reflectance light within biological tissue. The diffusion constant play major role in percent oxygenation and percent blood volume and varies with the biological material such as hemolyzed blood, whole blood, dermis and epidermis in vivo tissue. The diffusion constant can be modeled to consist of a contribution from bloodless tissue and blood present in tissue. The reflectance light for experimental are red light of 660nm, infrared light of 880nm, green light of 569nm. The correlation between the diffusion constant and biological tissue was analyzed by the intensity of reflectance light at different depth within human limb. The reflectance light was changed in response to physiological changes within biological tissue. The data for diffusion constant were obtained at different depth beneath the surface of the skin and will be utilized to amen the percent oxygenation and percent blood volume.

  • PDF

Allometry, Basal Area Growth, and Volume Equations for Quercus mongolica and Quercus variabilis in Gangwon Province of Korea

  • Choi, Jung-Kee;You, Byung-Oh;Burkhart, Harold E.
    • 한국산림과학회지
    • /
    • 제96권2호
    • /
    • pp.189-196
    • /
    • 2007
  • Allometry, basal area equations, and volume equations were developed with various tree measurement variables for the major species, Quercus mongolica and Quercus variabilis, in Korean natural hardwood forests. For allometry models, the relationships between total height-DBH, crown width-DBH, height to the widest portion of the crown-total height, and height to base of crown-total height were investigated. Multiple regression methods were used to relate annual basal area growth to tree variables of initial size (DBH, total height, crown width) and relative size (relative diameter, relative height) as well as competition measures (competition index, crown class, exposed crown area, percent exposed crown area, live crown ratio). For tree volume equations, the combined-variable and Schumacher models were fitted with DBH, total height and crown width for both species.

BTA 교반온도에 따른 변압기유의 체적고유저항 특성 (Volume Resistivity Characteristies of Transformer Oils due to the Stirring Temperalure of BTA)

  • 이용우;김석환;박문규;소병문;김왕곤;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.290-293
    • /
    • 1997
  • In this paper, volume resistivity is studied so that the electrical properties for transformer oil due to the stirring temperature of BTA is investigated. A measurement of volume resistivity using the VMG-1000 highmegohm meter is recorded after 10 minutes when the each voltage, and DC 100[V], 250[V], 500[V] and 1000[V] is applied, according to the step voltage appliaction method. A coaxial cylindrical liquid electrode to measure volume resistivity of specimen is used, and its geometric capacitance is 16[pF].

  • PDF

우리나라와 일본의 초등학교 수학과 교육과정 측정 영역 비교·분석: 외연량을 중심으로 (A comparative analysis of measurement domain of elementary school mathematics curriculum in Korea and Japan: centered on extensive quantity)

  • 이승은;이정은;박교식
    • 한국학교수학회논문집
    • /
    • 제21권1호
    • /
    • pp.19-37
    • /
    • 2018
  • 본 연구에서는 우리나라의 2015 개정 초등학교 수학과 교육과정과 일본의 2017 개정 초등학교 수학과 교육과정 <측정 영역>의 7개 외연량 시간, 길이, 들이, 무게, 넓이, 각도, 부피의 지도 실정을 비교, 측정, 어림재기의 세 관점에서 비교 분석하고 있다. 이러한 비교 분석의 결과로부터 우리나라의 차기 초등학교 수학 교과서 및 차기 초등학교 수학과 교육과정 개발과 관련하여 다음과 같은 논의가 필요하다는 것을 제안할 수 있다. 첫째, 시간, 길이, 들이, 무게, 넓이, 각도, 부피 각각에 대해 비교(직관적 비교, 직접 비교. 간접 비교), 직접 측정(임의 단위에 의한 측정, 표준 단위에 의한 측정), 간접 측정, 어림재기의 취급 범위를 명확히 하는 것에 대한 논의가 필요하다. 둘째, 직관적 비교가 곤란한 경우에 직접 비교를 하게 하는 것에 대한 논의가 필요하다. 셋째, 무게의 간접 비교를 재고하는 것에 대한 논의가 필요하다. 넷째, 임의 단위에 의한 각도의 측정을 재고하는 것에 대한 논의가 필요하다. 다섯째, 넓이 $1cm^2$$1m^2$ 및 부피 $1cm^3$$1m^3$가 각각 어느 정도의 크기인지를 짐작할 수 있게 하는 B류 어림재기를 취급하는 것에 대한 논의가 필요하다.

의복착용형 무선 호흡모니터 시스템 (Wearable wireless respiratory monitoring system)

  • 이인광;김성식;장종찬;김군진;김경아;이태수;차은종
    • 센서학회지
    • /
    • 제17권2호
    • /
    • pp.133-142
    • /
    • 2008
  • Respiration is induced by muscular contraction of the chest and abdomen, resulting in the abdominal volume change. Thus, continuous measurement of the abdominal dimension enables to monitor breathing activity. Conductive rubber cord has been previously introduced and tested to develop wearable application for respiratory measurements. The present study implemented wireless wearable respiratory monitoring system with the conductive rubber cord in the patient's pants. Signal extraction circuitry was developed to obtain the abdominal circumference changes reflecting the lung volume variation caused by respiratory activity. Wireless transmission was followed based on the zigbee communication protocol in a size of 65mm${\times}$105mm easily put in pocket. Successful wireless monitoring of respiration was performed in that breathing frequency was accurately estimated as well as different breathing patterns were easily recognized from the abdominal signal. $CO_2$ inhalation experiment was additionally performed in purpose of quantitative estimation of tidal volume. Air mixed with $0{\sim}5%\;CO_2$was inhaled by 4 normal males and the respiratory air flow rate, abdominal dimension change, and end tidal $CO_2$ concentration were simultaneously measured in steady state. $CO_2$ inhalation increased the tidal volume in normal physiological state with a correlation coefficient of 0.90 between the tidal volume and the end tidal $CO_2$ concentration. The tidal volume estimated from the abdominal signal linearly correlated with the accurate tidal volume measured by pneumotachometer with a correlation coefficient of 0.88 with mean relative error of approximately 8%. Therefore, the tidal volume was accurately estimated by measuring the abdominal dimension change.