• 제목/요약/키워드: volume concentration

검색결과 2,454건 처리시간 0.024초

Aerodynamic Particle Sizer (APS)를 이용한 고농도 $PM_{10}$ 사례 중 황사 판별기법 개발 (Developing a Method for Detecting the Asian dust event Among High $PM_{10}$ events Using Aerodynamic Particle Sizer (APS))

  • 이영곤;조천호;김명수
    • 대기
    • /
    • 제18권1호
    • /
    • pp.25-32
    • /
    • 2008
  • Log normalized volume size distribution (dV/dlog$D_p$) with 52 size ranges from 0.5 to $20.0{\mu}m$ was measured for the cases of high $PM_{10}$ mass concentration (> $200{\mu}gm^{-3}$) using the Aerodynamic Particle Sizer (APS) at the Korea Global Atmosphere Watch Center (KGAWC) from 6 April, 2006 to 5 April, 2007. Black Carbon (BC), gaseous pollutants of $NO_X$ and $SO_2$ and ${\AA}ngstr\ddot{o}m$ exponent were also measured to examine the properties of the volume size distribution. From distinct difference of the high volume concentration (> $100{\mu}m^3cm^{-3}$), the volume size distribution for each event day was clasified into four types: (1) Type 1 had the high volume concentration for supermicron particles from 2.3 to $6.0{\mu}m$ and maximum average volume concentration was $160.7{\mu}m^3cm^{-3}$ at $3.5{\mu}m$. (2) Type 2 represented the high volume concentration in the both size range of submicron ($0.7-1.0{\mu}m$) and supermicron particles ($2.1-4.1{\mu}m^3cm^{-3}$ and $136.2{\mu}m^3cm^{-3}$ were found at 0.8 and $3.3{\mu}m$ respectively. (3) Type 3 showed the high volume concentration in the size range of $0.5-3.5{\mu}m$ and highest volume concentration of $201.1{\mu}m^3cm^{-3}$ at the particle size bin of $0.8{\mu}m$. (4) Type 4 was characterized by the high volume concentration for the fine particles less than $1.2{\mu}m$ and very high concentration of $446.8{\mu}m^3cm^{-3}$. ${\AA}ngstr\ddot{o}m$ exponent, concentration of gaseous ($NO_X$ and $SO_2$), and particle (BC) pollutants suggested that Type 1 was a typical volume size distribution for the Asian dust and Type 3 provided transportation of air pollutants. The distribution in Type 2 found to have both characteristics of the Asian dust and air pollutants, and Type 4 was took place during the foggy atmosphere containing high density of local pollutants. Based on the properties of volume size distribution, we can identify the three major events contributing the increase of $PM_{10}$ mass concentration, and hope to provide a guideline for discriminating the Asian dust from high $PM_{10}$ events. More case studies and longeto advance this determination method.

A Study on the Correlation Analysis between the Daily Earthwork Volume and Fine Dust Concentration

  • Dong-Myeong, CHO;Ju-Yeon, LEE;Tae-Hwan, JEONG;Woo-Taeg, KWON
    • 웰빙융합연구
    • /
    • 제6권1호
    • /
    • pp.1-7
    • /
    • 2023
  • Purpose: Fine dust is classified as a group 1 carcinogen and poses a significant environmental problem that urgently requires improvement to protect the environmental rights of citizens. Given the difficulty of implementing measures to reduce overseas sources of fine dust, it is essential to first devise specific measures to address domestic emission sources. As such, this study aims to analyze the correlation between earthwork volume control and fine dust concentration as preliminary management measures to reduce the impact of scattering dust at construction sites. Based on real-time air quality information, field management measures will be presented to mitigate the effects of dust emissions. Research design, data and methodology: As examples, we selected construction sites that had recently undergone small-scale environmental impact assessment consultations. The standard earthwork volume was classified into grades using 20% intervals, and we applied AERMOD to predict the weighted concentration of fine dust based on the earthwork volume class and analyzed its correlation. Results: The results of this study demonstrate a strong correlation between earthwork volume and fine dust concentration. By utilizing the correlation analysis between earthwork volume and fine dust concentration on-site, this finding can be utilized as an effective fine dust management plan. Conclusions: This involves determining the daily earthwork intensity based on real-time air quality information and implementing measures to reduce scattering dust.

실내 체적과 라돈 농도와의 상관관계 연구 (A Study on the Correlation between the Volume of Indoor Space and the Measured Concentration of Indoor Radon)

  • 강성아;한동현;김종일
    • Journal of Radiation Protection and Research
    • /
    • 제32권3호
    • /
    • pp.97-104
    • /
    • 2007
  • 전주시에 소재한 아파트의 큰 방과 작은 방을 대상으로 실내 체적과 측정되는 라돈 농도와의 상관 관계를 분석하였다. 또한 실내의 라돈 농도를 측정하여 실내의 시간별 라돈 농도의 변화를 파악하고 이를 토대로 실내 라돈의 년간 피폭선량을 계산하였다. 본 연구를 위하여 각각 8개의 아파트 큰 방과 작은 방을 대상으로 라돈 농도를 측정하였으며, 큰 방의 평균 체적은 $31.59\;m^3$ 그리고 작은 방의 평균 체적은 $16.82\;m^3$이었다. 큰 방의 평균 라돈 농도는 $71.73\;Bq/m^3$, 작은 방의 평균 라돈 농도는 $108.51\;Bq/m^3$로 측정되어 실내 체적과 실내 라돈 농도는 반비례 관계로 나타났다. 밀폐된 실내 라돈 농도의 주 발생원이 건축자재임을 감안하여 건물 벽의 표면적을 체적으로 나누어 계측해 본 결과 표면적/체적의 비가 클수록 측정되는 실내 라돈 농도가 크게 나타났다. 실내 라돈 농도의 하루 중 시간에 따른 변화를 조사한 결과 오전 $8{\sim}10$시에 일 최고 농도($114.5\;Bq/m^3$)를 보였고, 오후 $2{\sim}4$시에 일 최저농도($67.7\;Bq/m^3$)를 나타냈으며, 하루 중 라돈 농도의 변화는 약 $46.8\;Bq/m^3$이었다. 8개 지점의 실내 라돈의 연간 피폭선량을 계산해 본 결과 0.3에서 2.16 mSv/yr사이로 나타나, 일부 아파트의 피폭선량이 국제방사선영향과학위원회(UNSCEAR)가 제시한 수치인 1.3 mSv/yr를 초과했다.

실시간 교통량을 이용한 고속도로 요금소 대기요염도 예측 (Air Pollution prediction at Highway Tollgate by Using Real Time Traffic Volume)

  • 박성규;김신도;이정주
    • 한국환경보건학회지
    • /
    • 제26권4호
    • /
    • pp.134-140
    • /
    • 2000
  • The increase in traffic is a worldwide phenomenon. In Korea, it has been increased by 20% per annual in recent 1990’s and approximately 10 millions cars had been registered until 1997. This traffic could easily affect and contribute the local outdoor air quality(QAQ) concerned. The QAQ in highway in one of the examples and the subject in this study. The seoul tollgate located at the north-end of Keypngbu Highway was selected for the study. In case of highway tollgate, the local air pollution could be directly affected by the traffic to approach, wait and start the tollgate. Nitrogen dioxide (NO$_2$) concentration exceeded the EAQS(Environmental Air Quality Standards), but overall indoor air quality was a little better than the outdoor air quality. The measured TSP concentration was much higher than that of the EAQS. To apply a management to a air quality problem of Seoul tollgate, it was predicted air quality with traffic volume and weather condition. It was calculated NO$_2$ emission with traffic volume and predicted in and out of booth by CALINE3 at the Seoul tollgate. To make a comparison between measured and predicted concentration, the prediction was good. It was shown that NO$_2$ concentration was high in the morning at the from Seoul direction and in the evening at the to Seoul direction. it was thought that NO$_2$ concentration variation was reflected according to the traffic volume.

  • PDF

Review of outcomes of using lower ethanol concentration (83%) in percutaneous ultrasound-guided renal cyst sclerotherapy in dogs

  • Sanghyeon Yoon;Jungmin Kwak;Deokho Im;Hakyoung Yoon
    • Journal of Veterinary Science
    • /
    • 제24권5호
    • /
    • pp.61.1-61.12
    • /
    • 2023
  • Background: Percutaneous renal cyst sclerotherapy (PRCS) as a treatment for renal cysts is usually performed with a high concentration of ethanol (≥ 90%). This study reviewed cases in which a lower concentration of ethanol (83%) was used for the procedure in dogs. Methods: Records of cases of renal cysts treated by sclerotherapy using 83% ethanol in dogs were reviewed. Outcomes of the treatment were evaluated by comparing volumes of renal cysts before the procedure and the volumes after treatment, using ultrasound images with the volume reduction rates classified as follows: < 50% of initial volume (failed); ≥ 50% but < 80% of initial volume (partial success); ≥ 80% but < 95% of initial volume (great success); ≥ 95% of initial volume (complete success). Results: Out of nine dog kidneys, renal cysts sclerotherapy with 83% ethanol achieved partial success in one kidney, great success in four, and complete success in the other four. No side effect was observed. The mean of the volume-reduction rates was 90.00 ± 11.00 while the minimum and maximum reduction rates were 65% and 100%, respectively. Conclusions: The lower ethanol concentration (83%) is good for disinfecting kidneys in PRCS.

실내녹화 부피비율이 실공간의 미세분진농도, 온도 및 상대습도에 미치는 영향 (Change in the Concentration of Fine Particles, Temperature, and Relative Humidity as Affected by Different Volume Ratios of Interior Greening in Real Indoor Space)

  • 주진희
    • 한국환경복원기술학회지
    • /
    • 제13권2호
    • /
    • pp.1-7
    • /
    • 2010
  • The study objective was to compare the interior greening volume ratios for the change in concentration of fine particle, temperature and relative humidity, and to identify the level of interior landscape volume ratio as a suitable condition to achieve the desired indoor properties. Plants were moved into a room (88m3) randomly. After moving, the volume ratio of the interior greening level was set at 0%, 1%, 2% and 3%. The concentration of fine particles was measured with a mini-volume portable air sampler (Air Metrics, USA). The temperature and relative humidity were recorded with a digital sensor (Kiwi-LTH, USA) during the experiment under different volume ratios with three replications. 1. The results of the change in concentration of the fine particles revealed a trend towards an increased volume ratio of interior greening with decreasing concentration of fine particles, compared to non-plants (0%). The concentration of fine particles at volume ratios of 0%, 1%, 2% and 3% was 55ug/$m^3$, 233ug/$m^3$, 40ug/$m^3$ and 30ug/$m^3$, respectively. 2. The change in temperature, at volume ratios of 0%, 1%, 2% and 3% was $21.2^{\circ}C$, $17.4^{\circ}C$, $16.7^{\circ}C$ and $18.9^{\circ}C$, respectively, in near interior greening, and $22.1^{\circ}C$, $18.7^{\circ}C$, $18.4^{\circ}C$ and $20.5^{\circ}C$ respectively, at a distance of 3m from the interior greening. These study results suggested that temperature was affected by volume ratio and distance from the interior greening. 3. The relative humidity, at volume ratios of 0%, 1%, 2% and 3% was 34.2%, 32.5%, 36.7%, and 46.9%, respectively, in near interior greening, and 31.2%, 26.9%, 31.4% and 38.3%, respectively, at a distance of 3m from the interior greening. With increasing volume ratio of interior landscape, there were positive and significant results between the distance difference and the relative humidity more than temperature.

대학의 실내 라돈가스 농도의 변화 평가 (Assesment of Indoor Radon Gas Concentration Change of College)

  • 박훈희;정의환;김학재;이주영;유광열
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권1호
    • /
    • pp.127-134
    • /
    • 2017
  • 본 연구는 실내 라돈 가스의 농도를 낮추기 위한 방법을 찾기 위해 건물의 준공연도, 건물의 용적, 환기 세 가지 변수에 따른 실내 라돈 농도를 비교, 측정하여 그 영향을 알아보고자 한다. 측정은 1973년에 건축이 되었고, 2011년에 증축이 된 건물의 6층을 대상으로 용적이 서로 다르고 준공연도가 1973년과 2011년인 6개의 강의실을 측정하였다. 준공연도에 따른 라돈농도를 비교하기 위해 4개의 강의실을 선정하였고, 용적에 따른 라돈농도를 비교하기 위해 준공연도가 같고 용적이 다른 강의실을 선정하였고, 환기에 따른 라돈농도를 비교하기 위해 6개의 강의실의 폐쇄와 환기를 시행하였다. 결과적으로 준공연도에 따른 라돈농도는 최근에 지어진 건물에서 라돈농도가 최대 4배 높게 나타났으며, 용적에 따른 라돈농도는 용적이 작을수록 높게 나타났다. 환기에 따른 라돈농도의 변화는 폐쇄 시보다 환기를 할 경우 약 80%의 감소율을 보였다. 특히, 준공연도가 최근이면서 용적이 작을수록 라돈농도가 높게 검출되었고, 세 가지 변수 중 환기가 라돈농도 감소에 가장 큰 영향을 끼쳐 라돈에 의한 피폭감소 효과를 기대할 수 있을 것으로 사료된다.

동결보호제의 농도와 평형시간이 생쥐의 정상배 및 분할배의 용적 변화와 체외 발달에 미치는 영향 (Effect of Cryoprotectant Concentration and Equilibration Time on Volume Change and In Vitro Development of Intact and Bisected Mouse Embryos following Rapid Freezing)

  • 이은봉;공일근;강대진;박충생
    • 한국가축번식학회지
    • /
    • 제16권1호
    • /
    • pp.47-53
    • /
    • 1992
  • This study was carried out to investage the effect of cryoprotectant concentration and equilibration time on volume change and in vitro development of intact and bisected mouse embryos by rapid freezing. When compacted morulae were rapidly frozen in 3.0 to 4.0 glycerol or DMSO with 0.25M sucrose solution, the superior(P<0.05) post-thaw survival rate was obtained at the glycerol concentration of 4.0M(89.4%) than 3.0M(71.4%) or 5.0M(42.4%), but at the DMSO concentration of 3.0M(84.5%) than 4.0M(51.1%) or 5.0M(0.0%). The optimal equilibraton time for rapid freezing of ZP-free or bisected morulae in 4.0M glycerol with 0.25M sucrose was found tobe 3 minutes. The minimal volume of compacted morulaewhich corresponded with 61 to 62% of pre-equilibrated embryo volume was obtained from equilibration for 3 minutes in both 3.0 and 4.0M glycerol solutions with 0.25M sucrose.

  • PDF

교통환기력에 의한 터널내 환기량 추정에 관한 연구 (Estimation of Ventilation Volume by Traffic Ventilation Force in Tunnel)

  • 김종호;이상칠;도연지;김신도
    • 한국대기환경학회지
    • /
    • 제11권3호
    • /
    • pp.273-278
    • /
    • 1995
  • This study is to estimate the ventilation volume by the traffic that originated from driving automobiles for two tunnels (Kugi tunnel and Kumhwa tunnel) that adopted natural ventilation system among tunnels of Seoul, and on the basis of which, we estimated the ventilation velume at various conditions. With the result of the estimation, we will present the basic method that can be operated with the optimum condition for the ventilation system. Estimating the predicted ventilation volume in the tennel by the pollutant concentration, we used traffic volume and CO emission data by the automobile speed and CO concentration in the tunnel. And, when we estimated the traffic ventilation volume by natural and traffic ventilation force, we used traffic volume, automobile speed, tunnel area, automobile area data and so on. As the result of simple regression between predicted ventilation volume and traffic ventilation volume, we attained the regression coefficient 0.88, and achieved the relation form that predicted ventilation volume equal 0.12x traffic ventilation volume-92, 000. Using this equation, we estimated the ventilation volume to satisfy the enviromnental standards of several space, and calculated the required volume for mechanical ventilation. Incase of Kumhwa Tunnel, there is a need of mechanical ventilation all day long to satisfy air quality standard 9 ppm for 8 hours average and 10 ppm for the indoor air quality standard of public facilities.

  • PDF

A Rapid Preconcentration Method Using Modified GP-MSE for Sensitive Determination of Trace Semivolatile Organic Pollutants in the Gas Phase of Ambient Air

  • He, Miao;Xu, Qingjuan;Yang, Cui;Piao, Xiangfan;Kannan, Narayanan;Li, Donghao
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권10호
    • /
    • pp.2995-3000
    • /
    • 2014
  • A sensitive concentration method utilising modified gas-purge microsyringe extraction (GP-MSE) was developed. Concentration (reduction in volume) to a microlitre volume was achieved. PAHs were utilised as semivolatile analytes to optimise the various parameters that affect the concentration efficiency. The injection rate and temperature were the key factors that affected the concentration efficiency. An efficient concentration (75.0-96.1%) of PAHs was obtained under the optimised conditions. The method exhibited good reproducibility (RSD values that ranged from 1.5 to 9.0%). The GP-MSE concentration method enhances the volume reduction (concentration factor), leading to a low method detection limit ($0.5-15ngL^{-1}$). Furthermore, this method offers the advantage of small-volume sampling, enabling even the detection of diurnal hourly changes in the concentration of PAHs in ambient air. Utilising this method in combination with GC-MS, the diurnal hourly flux of PAHs from the gas phase of ambient air was measured. Indeed, the proposed technique is a simple, fast, low-cost and environmentally friendly.