• 제목/요약/키워드: voltage control loop gain

검색결과 66건 처리시간 0.022초

가변 이득을 가지는 단상 PFC 디지털 제어기 (The Digital Controller of the Single-Phas Power Factor Correction(PFC) having the Variable Gain)

  • 정창용
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.163-167
    • /
    • 2000
  • This paper presents the digital control of single-phase power factor correction(PFC) converter which has the variable gain according to the condition of inner control loop error. Generally the gain of inner current control loop in single-stage PFC converter has a constant magnitude. This has a bad influence on the power factor because current loop doesn't operate smoothly in the condition that input voltage is low In particular a digital controller has more time delay than an analog controller and degrades This drops the phase margin of the total digital PFC system,. It causes the problem that the gain of current control loop isn't increased enough. In addition the oscillation happens in the peak value of the input voltage open loop PFC system gain changes according to ac input voltage. These aspects make the design of the digital PFC controller difficult The digital PFC controller presented in this paper has a variable gain of current control loop according to input voltage. The 1kW converter was used to verify the efficiency of the digital PFC controller.

  • PDF

가변이득을 가지는 디지털제어 단상 역률보상회로 (Single-Phase Power Factor Correction(PFC) Converter Using the Variable gain)

  • 백주원;신병철;정창용;이영운;유동욱;김홍근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.240-243
    • /
    • 2001
  • This paper presents the digital controller using variable gain for single-phase power factor correction (PFC) converter. Generally, the gain of inner current control loop in single-stage PFC converter has a constant magnitude. This is why input current is distorted under low input voltage. In particular, a digital controller has more time delay than an analog controller which degrades characteristics of control loop. So, it causes the problem that the gain of current control loop isn't increased enough. In addition, the oscillation happens in the peak value of the input voltage open loop PFC system gain changes according to ac input voltage. These aspects make the design of the digital PFC controller difficult. In this paper, the improved digital control method for single-phase power factor converter is presented. The variable gain according to input voltage and input current help to improve current shape. The 800W converter is manufactured to verify the proposed control method.

  • PDF

3상 PWM 인버터의 단일루프 전압제어기 설계 (Design of Single Loop Output Voltage Controller for 3 Phase PWM Inverterl)

  • 곽철훈;최규하
    • 전력전자학회논문지
    • /
    • 제8권6호
    • /
    • pp.561-568
    • /
    • 2003
  • PWM 인버터의 출력전압을 제어하는 방식에는 2가지 제어기법이 있다. 첫 번째 방법은 전류제어기를 사용하여 출력전압을 제어하는 이중 제어루프를 갖는 제어방식이며, 두 번째 방법은 단일루프만으로서 출력전압을 제어하는 제어방식이다. 일반적으로 3상 PWM 인버터의 제어기는 각상 제어 PI제어기, 2상 정지좌표계 PI제어기, 동기 좌표계 PI제어기로 구성되며, 각상제어 PI제어기를 이용하여 3상의 독립된 출력측 전압 및 전류를 제어하도록 구성된다. 단일루프 전압제어기는 높은 출력 임피던스의 경우 이중제어루프 도다 더 낮은 성능을 나타내기만, 낮은 출력임피던스의 경우에는 또는 부하범위에서 좋은 제어성능을 나타낸다. 또한 시뮬레이션과 실험을 통하여 이를 검증하였다.

3상 PWM 인버터의 단일제어루프 전압제어기의 설계 및 제어 (Design and control of Single Loop Output Voltage Controller for 3 Phase PWM Inverter)

  • 강병희;고재석;조준석;최규하;곽철훈;김진홍
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.496-500
    • /
    • 2001
  • There are two ways in the output voltage control method in PWM inverter. One is the double loop voltage control composed of inner current control loop and outer voltage control loop. Because it shows fast response and low steady state error, utilized in many application. The Other is single loop voltage control method composed of voltage control loop only. It's characteristics shows lower performance in case of high output impedance than double loop voltage control. But in low output impedance, it shows good control performance in all load range than double loop control. In this paper, single loop voltage control rule and gain was developed analytically, and these were verified through computer simulation and experiment.

  • PDF

PLL Equivalent Augmented System Incorporated with State Feedback Designed by LQR

  • Wanchana, Somsak;Benjanarasuth, Taworn;Komine, Noriyuki;Ngamwiwit, Jongkol
    • International Journal of Control, Automation, and Systems
    • /
    • 제5권2호
    • /
    • pp.161-169
    • /
    • 2007
  • The PLL equivalent augmented system incorporated with state feedback is proposed in this paper. The optimal value of filter time constant of loop filter in the phase-locked loop control system and the optimal state feedback gain designed by using linear quadratic regulator approach are derived. This approach allows the PLL control system to employ the large value of the phase-frequency gain $K_d$ and voltage control oscillator gain $K_o$. In designing, the structure of phase-locked loop control system will be rearranged to be a phase-locked loop equivalent augmented system by including the structure of loop filter into the process and by considering the voltage control oscillator as an additional integrator. The designed controller consisting of state feedback gain matrix K and integral gain $k_1$ is an optimal controller. The integral gain $k_1$ related to weighting matrices q and R will be an optimal value for assigning the filter time constant of loop filter. The experimental results in controlling the second-order lag pressure process using two types of loop filters show that the system response is fast without steady-state error, the output disturbance effect rejection is fast and the tracking to step changes is good.

Internal Model Control of UPS Inverter using Resonance Model

  • Park J. H.;Kim D. W.;Kim J. K.;Lee H. W.;Noh T. K.;Woo J. I.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.184-188
    • /
    • 2001
  • In this paper, a new fully digital control method for single-phase UPS inverter, which is based on the double control loop such as the outer voltage control loop and inner current control loop, is proposed. The inner current control loop is designed and implemented in the form of internal model control and takes the presence of computational time-delay into account. Therefore, this method provides an overshoot-free reference-to-output response. In the proposed scheme, the outer voltage control loop employing P controller with resonance model implemented by a DSP is introduced. The proposed resonance model has an infinite gain at resonant frequency, and it exhibits a function similar to an integrator for AC component. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been demonstrated by the simulation and experimental results respectively.

  • PDF

An Interleaved Five-level Boost Converter with Voltage-Balance Control

  • Chen, Jianfei;Hou, Shiying;Deng, Fujin;Chen, Zhe;Li, Jian
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1735-1742
    • /
    • 2016
  • This paper proposes an interleaved five-level boost converter based on a switched-capacitor network. The operating principle of the converter under the CCM mode is analyzed. A high voltage gain, low component stress, small input current ripple, and self-balancing function for the capacitor voltages in the switched-capacitor networks are achieved. In addition, a three-loop control strategy including an outer voltage loop, an inner current loop and a voltage-balance loop has been researched to achieve good performances and voltage-balance effect. An experimental study has been done to verify the correctness and feasibility of the proposed converter and control strategy.

정지좌표계를 이용한 3상 UPS용 PWM-VSI 제어 (PWM-VSI controller of Three-phase UPS Using Stationary Reference Frame)

  • 김민규;김재식;방상석;최재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.965-968
    • /
    • 2003
  • This paper describes the PWM-VSI controller of three-phase UPS system using stationary reference frame. This controller meets the specification the UPS inverter output voltage even under the unbalanced or nonlinear load. This controller is also constructed with duble control loop of the outer voltage control loop and the inner current control loop. For the fast response of the output voltage control, yhr inner current control loop of the capacitor current os used. To get the good property against overshoot, the If controller us used. The outer voltage controller is designed with P controller and the high gain transfer function is used for the zero steady state error. All control gains of both controller is designed base on the CDM method.

  • PDF

저압 직류 배전용 양극성 DC-DC 컨버터에 관한 연구 (A Study on Bipolar DC-DC Converter for Low Voltage Direct Current Distribution)

  • 이정용;김호성;조진태;김주용;조영훈
    • 전력전자학회논문지
    • /
    • 제24권4호
    • /
    • pp.229-236
    • /
    • 2019
  • This study proposes a DC-DC converter topology of solid-state transformer for low-voltage DC distribution. The proposed topology consists of a voltage balancer and bipolar DC-DC converter. The voltage and current equations are obtained on the basis of switching states to design the controller. The open-loop gain of the controller is achieved using the derived voltage and current equations. The controller gain is selected through the frequency analysis of the loop gain. The inductance and capacitance are calculated considering the voltage and current ripples. The prototype is fabricated in accordance with the designed system parameters. The proposed topology and designed controller are verified through simulation and experiment.

임의 파형 발생기를 위한 단일 루프 전압 제어기 설계 (Design of the Single-loop Voltage Controller for Arbitrary Waveform Generator)

  • 김현식;지승준;설승기
    • 전력전자학회논문지
    • /
    • 제21권1호
    • /
    • pp.58-64
    • /
    • 2016
  • This study presents a design method for a single-loop voltage controller that is suitable for an arbitrary waveform generator (AWG). The voltage control algorithm of AWG should ensure high dynamic performance and should attain sufficient robustness to disturbances such as inverter nonlinearity, sensor noise, and load current. By analyzing the power circuit of AWG, control limitation and control target are presented to improve the dynamic performance of AWG. The proposed voltage control algorithm is composed of a single-loop output voltage control, an inverter current feedback term to improve transient response, and a load current feedforward term to prevent voltage distortion. The guideline for setting control gain is presented based on output filter parameters and digital time delay. The performance of the proposed algorithm is proven by experimental results through comparison with the conventional algorithm.