• Title/Summary/Keyword: void fraction

Search Result 300, Processing Time 0.023 seconds

Research on void drift between rod bundle subchannels

  • Shasha Liu;Zaiyong Ma;Bo Pang;Rui Zhang;Luteng Zhang;Quanyao Ren;Liangming Pan
    • Nuclear Engineering and Technology
    • /
    • v.56 no.8
    • /
    • pp.3330-3334
    • /
    • 2024
  • Void drift between subchannels in a rod bundle is a crucial phenomenon affecting the calculation accuracy of thermal-hydraulic parameters in SMRs. It holds significant importance in enhancing the precision of safety analysis for SMRs. Existing research on experiment and model of void drift between rod bundle subchannels is relatively rare, and the accuracy of model calculations requires improvement. In this study, experiments on gas-liquid two-phase non-equilibrium flow were conducted to measure the redistribution of two-phase flow induced by void drift in a 1 × 2 rod bundle. The experiment results indicated that in bubby flow regime with void fraction less than 0.3, the void diffusion coefficient showed little variation with changes in void fraction. However, in slug flow and annular flow regimes with void fraction exceeding 0.3, the void diffusion coefficient significantly increased with an increase in void fraction. Furthermore, a new void drift model was developed and validated based on a subchannel code. The overall predicted uncertainty for the outlet void fraction in the rod bundle benchmark was less than 13%.

Void Fraction Measurements Using the Impedance Method (임피던스 방법을 이용한 기공율 측정에 대한 연구)

  • Kim, M.H.;Yang, H.C.;Song, C.H.;Jung, M.K.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.721-727
    • /
    • 2000
  • Impedance method was carried out to design the electrode that can measure the void fraction of the bubbly flow in pool reservoir. To find out the optimum electrode shape, Styrofoam-tests were performed in a specially designed acrylic reservoir. Three kinds of electrodes were designed to compare the characteristics of water-air flow. The resistance was increased as the void fraction increased and the capacitance was decreased as the void fraction increased. The resistance is a main parameter to express the nature of the water-air flow in impedance method. Almost all the values of impedance were involved in resistance. The degree of deviation from the mean-resistance values showed reasonable results. Electrode type-I expressed excellent results among the three electrode shapes. The impedance values in void fraction 0-10% were similar to those of Maxwell's equation. But the impedance values in void fraction 10-20% were not similar to those of Maxwell' equation because of the edge effect near electrode.

  • PDF

Precise Void Fraction Measurement in Two-phase Flows Independent of the Flow Regime Using Gamma-ray Attenuation

  • Nazemi, E.;Feghhi, S.A.H.;Roshani, G.H.;Gholipour Peyvandi, R.;Setayeshi, S.
    • Nuclear Engineering and Technology
    • /
    • v.48 no.1
    • /
    • pp.64-71
    • /
    • 2016
  • Void fraction is an important parameter in the oil industry. This quantity is necessary for volume rate measurement in multiphase flows. In this study, the void fraction percentage was estimated precisely, independent of the flow regime in gas-liquid two-phase flows by using ${\gamma}-ray$ attenuation and a multilayer perceptron neural network. In all previous studies that implemented a multibeam ${\gamma}-ray$ attenuation technique to determine void fraction independent of the flow regime in two-phase flows, three or more detectors were used while in this study just two NaI detectors were used. Using fewer detectors is of advantage in industrial nuclear gauges because of reduced expense and improved simplicity. In this work, an artificial neural network is also implemented to predict the void fraction percentage independent of the flow regime. To do this, a multilayer perceptron neural network is used for developing the artificial neural network model in MATLAB. The required data for training and testing the network in three different regimes (annular, stratified, and bubbly) were obtained using an experimental setup. Using the technique developed in this work, void fraction percentages were predicted with mean relative error of <1.4%.

A Study on Strain-Void Growth Mechanism of Dual Phase Steel by Statistical Method (통계적 방법을 이용한 복합조직강의 변형률과 보이드 성장거동에 관한 연구)

  • 오경훈;유용석;오택열
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.533-538
    • /
    • 2000
  • Ductile fracture of dual phase steel begins with void nucleation, at martensite-ferrite interface of deformed martensite particle. In this study, void nucleation, growth, and coalescence under various strain were studied in dual phase steel. Therefore, by means of the heat treatment of low carbon steel, the study deals with void nucleation and growth for ferrite grain size and martensite volume fraction of dual phase steel using statistical method. Void nucleation and growth with increasing strain are shown depend upon the ferrite grain size. Voids volume fraction generally increase as ferrite grain size decease.

  • PDF

Design and Performance Evaluation of Visualization System for Measuring the Void Fraction of Two-phase Flow (다상 유동 Void Fraction 가시화 장치 설계 및 성능 평가)

  • Choi, Chang-Hyun;Choi, Seong-Won;Song, Simon
    • Journal of the Korean Society of Visualization
    • /
    • v.15 no.1
    • /
    • pp.11-18
    • /
    • 2017
  • A two-phase flow observed in a heat exchanger or nuclear power generation often has a profound effect on undesirable noise or flow characteristics. Void fraction, which refers to the ratio of gas (or liquid) to the total fluid, affects heat transfer coefficient, vibration and so forth. In other words, void fraction is one of most important parameters in two-phase flow since it contributes to comprehend the characteristics of two-phase flow. We developed a two-phase flow visualization system to measure cross-sectional and volumetric void fractions by using quick closing valves and image processing software. With this system, we could observe the plug, slug, and stratified flow patterns of two-phase flow and measure a myriad of void fractions. As a consequence of the experiment, we found that the estimated void fractions were largely coincident with the predictive values by Chisholm model.

Power Reactor Simulation, considering the Void Fraction and the Water Flow in the Reactor Core (노심의 상속도 및 Void Fraction 을 고려한 동력로의 Simulation)

  • Yang Soo Lee
    • 전기의세계
    • /
    • v.13 no.4
    • /
    • pp.16-24
    • /
    • 1964
  • The dynamic equations of the void fraction and the water velocity in boiling region of the BWR reactor core are derived. And these equations are approximated to be able to set on an PACE analog computor. The transient analysis and the frequency response obtained by analog computer are compared with other by digital computor.

  • PDF

Relationship between void fraction and mixing in bubble column flow (기포탑 유동에서의 기포분율과 혼합정도의 상관관계)

  • Zahidul, Islam MD;Lee, Jubeom;Park, Hyungmin
    • Journal of the Korean Society of Visualization
    • /
    • v.15 no.1
    • /
    • pp.41-46
    • /
    • 2017
  • Control of mixing and transport processes are the key areas that can be benefited by understanding the hydrodynamics in gas-liquid two-phase flows. In particular, the enhanced bubble-induced liquid-phase mixing is known to be a function of void fraction distribution, gas phase velocity and so on. To further our insight on the characteristics of the liquid-phase mixing induced by the bubbles, in the present study, we experimentally investigate the mixing performance of a rectangular bubble column while changing the void fraction from 0.006 to 0.075%. A shadowgraphy technique is used to measure the gas-phase properties such as void fraction and size/velocity of bubbles. On the other hand, we use dye visualization with low diffusive buoyant dye to directly measure the level of mixing. Finally, we confirm that the time taken for full mixing scales with the inverse of volume void fraction.

AN IMPROVED ELECTRICAL-CONDUCTANCE SENSOR FOR VOID-FRACTION MEASUREMENT IN A HORIZONTAL PIPE

  • KO, MIN SEOK;LEE, BO AN;WON, WOO YOUN;LEE, YEON GUN;JERNG, DONG WOOK;KIM, SIN
    • Nuclear Engineering and Technology
    • /
    • v.47 no.7
    • /
    • pp.804-813
    • /
    • 2015
  • The electrical-impedance method has been widely used for void-fraction measurement in two-phase flow due to its many favorable features. In the impedance method, the response characteristics of the electrical signal heavily depend upon flow pattern, as well as phasic volume. Thus, information on the flow pattern should be given for reliable void-fraction measurement. This study proposes an improved electrical-conductance sensor composed of a three-electrode set of adjacent and opposite electrodes. In the proposed sensor, conductance readings are directly converted into the flow pattern through a specified criterion and are consecutively used to estimate the corresponding void fraction. Since the flow pattern and the void fraction are evaluated by reading conductance measurements, complexity of data processing can be significantly reduced and real-time information provided. Before actual applications, several numerical calculations are performed to optimize electrode and insulator sizes, and optimal design is verified by static experiments. Finally, the proposed sensor is applied for air-water two-phase flow in a horizontal loop with a 40-mm inner diameter and a 5-m length, and its measurement results are compared with those of a wire-mesh sensor.

DESIGN AND APPLICATION OF A SINGLE-BEAM GAMMA DENSITOMETER FOR VOID FRACTION MEASUREMENT IN A SMALL DIAMETER STAINLESS STEEL PIPE IN A CRITICAL FLOW CONDITION

  • Park, Hyun-Sik;Chung, Chang-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.349-358
    • /
    • 2007
  • A single-beam gamma densitometer is utilized to measure the average void fraction in a small diameter stainless steel pipe under critical flow conditions. A typical design of a single-beam gamma densitometer is composed of a sealed gammaray source, a collimator, a scintillation detector, and a data acquisition system that includes an amplifier and a single channel analyzer. It is operated in the count mode and can be calibrated with a test pipe and various types of phantoms made of polyethylene. A good average void fraction is obtained for a small diameter pipe with various flow regimes of the core, annular, stratified, and bubbly flows. Several factors influencing the performance of the gamma densitometer are examined, including the distance between the source and the detector, the measuring time, and the ambient temperature. The void fraction is measured during an adiabatic downward two-phase critical flow in a vertical pipe. The test pipe has an inner diameter of 10.9 mm and a thickness of 3.2 mm. The average void fraction was reasonably measured for a two-phase critical flow in the presence of nitrogen gas.

Void Fraction Measurement by the Improved Multi-Channel Impedance Void Meter (개량된 다채널 임피던스형 측정기에 의한 기포율의 측정)

  • Song, Cheol-Hwa;Jeong, Mun-Gi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.1
    • /
    • pp.384-398
    • /
    • 1996
  • An improved multi-channel Impedance Void Meter (IVM) is developed to measure an area-averaged void fraction. It consists of a main sensor, a reference sensor and a signal processor. The sensor was designed to be flush-mounted to the inner wall of the test section to avoid the flow disturbances. Guard electrodes are used to obtain evenly distributed electrical field in a measuring volume. A reference sensor is also installed to eliminate the drift in void signal caused by the changes in electrical properties of working fluid. The signal processor with three channels is specially designed so as to minimize the inherent error due to the phase difference between channels. As an example of applications, the mean and fluctuating components of void fraction are measured for bubbly and slug flow regime, and it is shown that IVM has good dynamic resolution which is required to investigate the structural developments of bubbly flow and the propagation of void waves in a flow channel.