• Title/Summary/Keyword: visualized image

Search Result 292, Processing Time 0.028 seconds

Wavelet Analysis of Visualized Image (가시화 영상의 웨이브렛 해석)

  • Park, Young-Sik;Kim, Okug-Gyu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.3
    • /
    • pp.143-148
    • /
    • 2007
  • The many studies have been proceeding to express accurately the feature of a sudden signal and a uncertain system in the image processing field. It is well know that Fourier Transform is widely used for frequency analysis of any signal. However, The frequency transform domain is not used for expressing the sudden signal change and non-stationary signal at the time-axis by this method. This paper describes of image analysis by discrete wavelet transform. Wavelet modulus maxima on transformed plane gives the Lipschitz exponent expression, which is useful to examine the characteristics of signal or the edge of an image. It is possible to reconstruct the original image only using the few maxima points. The fractal analysis is applied as an examples. The visualized image of oil flow on a ship model is analyzed. The fractal variable is obtained by the maxima analysis and the good results on the exprement is obtained by the visualized image analysis.

  • PDF

2-Dimensional Visualization of the Flame Propagation in a Four-Valve Spark-Ignition Engine (가솔린엔진에서의 2차원 화염 가시화)

  • Bae, Choong-Sik
    • Journal of the Korean Society of Combustion
    • /
    • v.1 no.1
    • /
    • pp.65-73
    • /
    • 1996
  • Flame propagation in a four-valve spark-ignition optical engine was visualized under lean-bum conditions with A/F=18 at 2000rpm. The early flame development in a four-valve pentroof-chamber single-cylinder engine was examined with imaging of the laser-induced Mie scattered light using an image-intensified CCD camera. Flame profiles along the line-of-sight were also visualized through a quartz piston window. Two-dimensional flame structures were visualized with a Proxitronic HF-1 fast motion camera system by Mie scattering from titanium dioxide particles along a planar laser sheet generated by a copper vapor laser. The flame propagation images were subsequently analysed with an image processing programme to obtain information about the flame structure under different tumble flow conditions generated by sleeved and non-sleeved intake ports. This allowed enhancement of the flame images and calculation of the enflamed area, and the displacement of its center, as a function of the tumble flow induced by the pentroof-chamber in the vicinity of spark plug. Image processing of the early flame development quantified the correlation between flame and flow characteristics near the spark plug at the time of ignition which has been known to be one of the most important factors in cyclic combustion variations in lean-burn engines. The results were also compared with direct flame images obtained from the natural flame luminosity of the lean mixture.

  • PDF

A pilot application study of densitometric image analysis as a potential comparative evaluation method for visualized fingerprints

  • Kim, Eun-Ji;Kim, Soo-Kyung;Seo, Kyung-Suk;Choi, Sung-Woon
    • Analytical Science and Technology
    • /
    • v.33 no.4
    • /
    • pp.197-207
    • /
    • 2020
  • The current comparison methods with scoring systems that are used to compare visualized latent fingerprints (LF) have disadvantages. Evaluators using these methods are prone to make errors and fail to discriminate LFs correctly to notice the differences among those LFs. Therefore, a comparative and quantitative evaluation method that is capable of obtaining more objective and quantitative results is needed. Densitometric image analysis (DIA) is used in other fields as a reliable semi-quantitative comparison method. To apply DIA to LFs, the potential variables that can occur during the DIA process were tested. The visualized ridges of LFs can be compared using the concentration of dots against the background to make it possible to analyze the ridges with DIA. The variables that can be present during the DIA process include the thickness of the analysis line, the number of ridges to be taken, the number of divided zones within each of the fingerprints, and the angles of the analysis line against the ridge lines that were selected. From the analysis of the inked fingerprints and circular lines that are similar to fingerprints, the angle of the analysis lines with the ridge line was the most significant variable. The preliminary test result was applied to the comparison of LFs that were developed with the powder method and then compared with the AFIS analysis. A similar trend was found, and a more detailed and semi-quantitative comparison of the visualized LFs was possible. In the future, it is necessary to check the evaluative ability of the DIA method by analyzing the visualized LFs with other various development methods. However, DIA is currently an option that can be used as an objective comparative evaluation method during fingerprint studies with supplementary role.

Maxima Analysis from Visualized Image based on Multi-Resolution Analysis (다중해상도 웨이브렛 해석을 기본으로 한 가시화 영상의 극대값 해석)

  • Park, Young-Sik;Kim, Og-Gyu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.2
    • /
    • pp.157-162
    • /
    • 2010
  • In this paper we propose a fractal analysis based on the discrete wavelet transform. It is well known that Fourier Transform is widely used for frequency analysis of random signal. However, the frequency domain is not used for expressing the sudden signal change and non-stationary signal at the time-axis by this method. Maximum value in the wavelet modules can be expressed by the Lipschitz exponent, which is useful to represent the characteristics of signal or the edge of an image. It is possible to reconstruct the original image only by using the few maximum points. The v possible image It iusing oil was acquired to interpret the maximum value. ufter that, it was applied to the v possible image of a ship model. In addition, the fractal dimens by by the conlapse process of the sediment particle was examined. In this paper, the fractal dimens by has been obtained by the maximum value and the experiment obtained from the visualized image also acquired the same result as existing methods.

Practical visualization of discontinuity distribution in subsurface using borehole image analysis (시추공영상분석을 이용한 지하 불연속면 분포의 가시화 실용연구)

  • 송무영;박찬석
    • The Journal of Engineering Geology
    • /
    • v.12 no.1
    • /
    • pp.23-34
    • /
    • 2002
  • Borehole image analysis has been carried out to obtain the detailed geological data by approach of direct observation. Direct application of borehole image analysis inevitably gives rise to a few of restriction of data acquisition due to the limited information within narrow borehole space. Considering the apparent dip of discontinuity surface depending upon the direction, the visualized program of two-dimensional subsurface discontinuities is coded. Borehole image analysis can compensate the distribution of subsurface discontinuity extending into the expected area of investigation. In order to draw subsurface profile in the proposed area of subsurface construction, visualized program is coded as a window GUI (Graphic User Interface) using Fortran and Visual Basic Programming languages. It is to open publicly for the usage of whoever is in want. Discontinuity distribution map is visualized along the Proposed line of tunnel in the Janggye-ri area, Jangsu-gun. Using the visualized program, the limited information from borehole spatially applies into analysis of overall subsurface structures, and the distributional characteristics of discontinuity anticipate at the proposed area. In addition, spacing and extension of joint and depth of discontinuity effecting tunnel safety can be visualized along the direction of the proposed tunnel. These lines of visualization apply design and construction of fundanmental structures.

A COMPARATIVE STUDY OF THREE-DIMENSIONAL RECONSTRUCTIVE IMAGES OF TEMPOROMANDIBULAR JOINT USING COMPUTED TOMOGRAM (전산화단층상을 이용한 측두하악관절의 삼차원 재구성상의 비교연구)

  • LIM SUK-YOUNG;KOH KWANG-JOON
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.23 no.2
    • /
    • pp.335-344
    • /
    • 1993
  • The purpose of this study was to clarify the spatial relationship of temporomandibular joint and to an aid in the diagnosis of temporomandibular disorder. For this study, three-dimensional images of normal temporomandibular joints were reconstructed by computer image analysis system and three-dimensional reconstructive program integrated in computed tomography. The obtained results were as follows: 1. Two-dimensional computed tomograms had the better resolution than three dimensional computed tomograms in the evaluation of bone structure and the disk of TMJ. 2. Direct sagittal computed tomograms and coronal computed tomograms had the better resolution in the evaluation of the disk of TMJ. 3. The positional relationship of the disk could be visualized, but the configuration of the disk could not be clearly visualized on three-dimensional reconstructive CT images. 4. Three-dimensional reconstructive CT images had the smoother margin than three-dimensional images reconstructed by computer image analysis system, but the images of the latter had the better perspective. 5. Three-dimensional reconstructive images had the better spatial relationship of the TMJ articulation, and the joint spaces were more clearly visualized on dissection images.

  • PDF

Prostate MR and Pathology Image Fusion through Image Correction and Multi-stage Registration (영상보정 및 다단계 정합을 통한 전립선 MR 영상과 병리 영상간 융합)

  • Jung, Ju-Lip;Jo, Hyun-Hee;Hong, Helen
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.9
    • /
    • pp.700-704
    • /
    • 2009
  • In this paper, we propose a method for combining MR image with histopathology image of the prostate using image correction and multi-stage registration. Our method consists of four steps. First, the intensity of prostate bleeding area on T2-weighted MR image is substituted for that on T1-weighted MR image. And two or four tissue sections of the prostate in histopathology image are combined to produce a single prostate image by manual stitching. Second, rigid registration is performed to find the affine transformations that to optimize mutual information between MR and histopathology images. Third, the result of affine registration is deformed by the TPS warping. Finally, aligned images are visualized by the intensity intermixing. Experimental results show that the prostate tumor lesion can be properly located and clearly visualized within MR images for tissue characterization comparison and that the registration error between T2-weighted MR and histopathology image was 0.0815mm.

PANORAMIC IMAGE OF MANDIBULAR CONDYLE ACCORDING TO HEAD POSITION (두부 위치에 따른 하악 과두의 파노라마상)

  • Kim Jeong Hwa;Choi Soon Chul
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.2
    • /
    • pp.219-225
    • /
    • 1990
  • Panoramic radiography is convenient in clinic and visualizes those areas which other technique do not give. But the technique has limitation of image distortion which results from the relationship of the ramus to the focal trough and from the direction of the central ray. This study is, using 7 dry skulls, to determine the effect of rotation of patient's head on reducing those distortion and determine the magnification ratio of images of mandibular condyle in rotated patient head position. The obtained results were as follows: 1. Generally, in panoramic radiography the anterolateral portion of the mandibular condyle was best to be visualized. 2. There are no significant difference between the image readability of anteromedial portion and that of anterocentral portion of the mandibular condyle. 3. Anterolateral portion of the mandibular condyle was better visualized in rotated head position by 20 degree or horizontal condylar inclination than in conventional position or in rotated head position by 10 degree. 4. The magnification ratio of the anteroposterior diameter in the image of mandibular condyle was least in the rotated head position by horizontal inclination of the mandibular condyle and was largest by 20 degree.

  • PDF

A Study on the Analysis of Temperature Field of Bubbly Flow Using Thermo-sensitive Liquid Crystals (감온액정을 이용한 기포유동의 온도장 해석에 관한 연구)

  • Bae, Dae-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.11
    • /
    • pp.1572-1578
    • /
    • 2003
  • Particle Image Thermometry(PIT) with liquid crystal tracers is used for visualizing and analysis of the bubbly flow in a vertical temperature gradient. Quantitative data of the temperature were obtained by applying the color-image processing to a visualized image, and neural-network was applied to the color-to-temperature calibration. This paper describes the method, and presents the transient mixing temperature patterns of the bubbly flow.

A Study on Bubbly Flow using PIV Measurement (PIV 법을 이용한 기포유동에 관한 연구)

  • 배대석;권오봉
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.4
    • /
    • pp.898-903
    • /
    • 2001
  • The particle image velocimetry with liquid crystal tracers is used for visualizing and analysis of the bubbly flow in a vertical temperature gradient. This method allows simultaneous measurement of velocity and temperature field at a given instant of time Quantitative data of velocity were obtained by applying the MQD technique to visualized image. The paper describes the method, and presents the transient velocity patterns of bubbly flow.

  • PDF