Chair side measuring instrument for quantification of the extent of a transverse maxillary occlusal plane cant

  • Naini, Farhad B.;Messiha, Ashraf;Gill, Daljit S.
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.21.1-21.3
    • /
    • 2019
  • Background: Treatment planning the correction of a transverse maxillary occlusal plane cant often involves a degree of qualitative "eyeballing", with the attendant possibility of error in the estimated judgement. A simple chair side technique permits quantification of the extent of asymmetry and thereby quantitative measurements for the correction of the occlusal plane cant. Methods: A measuring instrument may be constructed by soldering the edge of a stainless steel dental ruler at 90° to the flat surface of a similar ruler. With the patient either standing in natural head position, or alternatively seated upright in the dental chair, and a dental photographic retractor in situ, the flat under-surface of the horizontal part of this measuring instrument is placed on a unilateral segment of a bilateral structure, e.g. the higher maxillary canine orthodontic bracket hook. The vertical ruler is held next to the contralateral canine tooth, and the vertical distance measured directly from the canine bracket to the flat under-surface of the horizontal part of the measuring instrument. Results: This vertical distance quantifies the overall extent of movement required to level the maxillary occlusal plane. Conclusions: This measuring instrument and simple chair side technique helps to quantify the overall extent of surgical levelling required and may be a useful additional technique in our clinical diagnostic armamentarium.

In-plane buckling strength of fixed arch ribs subjected vertical distributed loading (수직 등분포 하중을 받는 고정 지점 포물선 아치 리브의 면내 좌굴 강도)

  • Moon, Ji Ho;Yoon, Ki Yong;Kim, Sung Hoon;Lee, Hak Eun
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.4 s.77
    • /
    • pp.439-447
    • /
    • 2005
  • When arch ribs are subjected to vertical loading, they may buckle suddenly towards the in-plane direction. Therefore, the designer should consider their in-plane stability. In this paper, the in-plane elastic and inelastic buckling strength of parabolic, fixed arch ribs subjected to vertical distributed loading were investigated using the finite element method. A finite element model for the snap-through and inelastic behavior of arch ribs was verified using other researchers' test results. The ultimate strength of arch ribs was determined by taking into account their large deformation, material inelasticity, and residual stress. Finally, the finite element analysis results were compared with the EC3 design code.

An experimental study on the load transfer machanism of shallow 2-arch tunnel excavation sequence with vertical discontinuity planes in sandy ground (연직 불연속면이 존재하는 얕은 심도의 사질토 지반에서 2-arch 터널 단계별 굴착에 따른 하중전이에 관한 실험적연구)

  • Oh, Bum-Jin;Lee, Sang-Duk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.3
    • /
    • pp.215-231
    • /
    • 2011
  • In this study, the behavior of a shallow 2-arch tunnel during the excavation in the sandy ground containing vertical discontinuity plane was experimentally studied. Load transfer mechanism in the pillar caused by a 2-arch tunnel excavation was observed. The position of the vertical discontinuity plane was varied. Model tests were carried out in the normal construction sequence of 2-arch tunnel. Test results-showed that the load transfer caused by the 2-arch tunnel excavation was concentrated in the discontinuity plane, and was cut by the discontinuity plane, so no load transfer took place above the discontinuity plane. It was also shown that the effect of adjacent tunnel excavation on the pillar load and the ground deformation was greater when excavating the upper half-face of the main tunnel, more than when excavating the lower half-face.

Characteristic Analysis on Radio Propagation Path Loss Characteristics of Vertical Electric Dipole in Time Domain (시간영역에서 수직 다이폴의 전파경로손실 특성 해석)

  • Hong, Ic-Pyo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.7
    • /
    • pp.1558-1563
    • /
    • 2013
  • In this paper, we analyze the radio propagation path loss characteristics for the vertical electric dipole radiation over the perfect electric conductor(PEC) ground plane. Most research have been performed about the electromagnetic analysis of vertical electric dipole in free space for time domain or frequency domain. But this paper present the radio propagation path loss over PEC ground plane in time domain under the assumption of the vertical electric dipole as a base station. From the simulated results, the ground plane effect can change the location of near field from transmitting antenna and the transient responses at mobile are calculated. The results of this paper can be applied to surface radar or signal processing applications.

Analytical solutions for crack initiation on floor-strata interface during mining

  • Zhao, Chongbin
    • Geomechanics and Engineering
    • /
    • v.8 no.2
    • /
    • pp.237-255
    • /
    • 2015
  • From the related engineering principles, analytical solutions for horizontal crack initiation and propagation on a coal panel floor-underlying strata interface due to coal panel excavation are derived in this paper. Two important concepts, namely the critical panel width of horizontal crack initiation on the panel floor-underlying strata interface and the critical panel width of vertical fracture (crack) initiation in the panel floor, have been presented. The resulting analytical solution indicates that: (1) the first criterion can be used to express the condition under which horizontal plane cracks (on the panel floor-underlying strata interface or in the panel floor because of delamination) due to the mining induced vertical stress will initiate and propagate; (2) the second criterion can be used to express the condition under which vertical plane cracks (in the panel floor) due to the mining induced horizontal stress will initiate and propagate; (3) this orthogonal set of horizontal and vertical plane cracks, once formed, will provide the necessary weak network for the flow of gas to inrush into the panel. Two characteristic equations are given to quantitatively estimate both the critical panel width of vertical fracture initiation in the panel floor and the critical panel width of horizontal crack initiation on the interface between the panel floor and its underlying strata. The significance of this study is to provide not only some theoretical bases for understanding the fundamental mechanism of a longwall floor gas inrush problem but also a benchmark solution for verifying any numerical methods that are used to deal with this kind of gas inrush problem.

A STUDY ON THE CENTRAL PLANE OF IMAGE LAYER IN PANORAMIC RADIOGRAPH (파노라마방사선사진에 있어서 상층중심면에 관한 연구)

  • Lee Mun Bai;Park Chang Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.16 no.1
    • /
    • pp.59-68
    • /
    • 1986
  • The purpose of this investigation was to locate the central plane of the image layer on the panoramic machine relative to a specific point on the machine. In the study of the central plane of the image layer of panoramic radiograph, using the Morrita Company PANEX-EC a series of 33 exposures were taken with the 4-5 experimental pins placed in the holes of the plastic model plate, then evaluated by human eye. The author analyzed the central plane of the image layer by Mitutoyo-A-221 and calculated horizontal and vertical magnification ratio in the central plane of the image layer determined experimentally. The results were as follows: 1. The location of the central plane of the image layer determined experimentally was to lateral, compared with manufactural central plane. 2. Horizontal magnification ratio in the central plane of the image layer determined experimentally was 9.25%. 3. Vertical magnification ratio in the central plane of the image layer determined experimentally was 9.17%.

  • PDF

Pharyngeal airway analysis of different craniofacial morphology using cone-beam computed tomography (CBCT) (Cone beam CT를 이용한 안면골격형태에 따른 상기도 공간 분석)

  • Kim, Yong-Il;Kim, Seong-Sik;Son, Woo-Sung;Park, Soo-Byung
    • The korean journal of orthodontics
    • /
    • v.39 no.3
    • /
    • pp.136-145
    • /
    • 2009
  • Objective: CBCT has become popular for orthodontic diagnosis and treatment planning in recent times. The 3D pharyngeal airway space needs to be analysed using a 3D diagnostic tool. The aim of this study was to analyse the pharyngeal airway of different craniofacial morphology using CBCT. Methods: The sample compromised 102 subjects divided into 3 groups (Class I, II, III) and 6 subgroups according to normal or vertical craniofacial patterns. All samples had CBCT (VCT, Vatech, Seoul, Korea) taken for orthodontic treatment. The pharyngeal airway was assessed according to the reference planes: aa plane (the most anterior point on the anterior arch of atlas), $CV_2$ plane, and $CV_3$ plane (most infero-anterior point on the body of the second & third cervical vertebra). The intergroup comparison was performed with one-way ANOVA and duncan test as a second step. Results: The results showed the pharyngeal airway and anteroposterior width of group 2 (Class II) in aa plane, $CV_2$ plane, $CV_3$ plane were significant narrower than in group 3 (Class III). There was no significant difference between vertical and normal craniofacial patterns except for the anteroposterior pharyngeal width of Group 1 (Class I) in aa plane. Conclusions: Subjects with Class II patterns have a significantly narrower pharyngeal airway than those with Class III. However there was no difference in pharyngeal airway between vertical and normal craniofacial morphology.

EO Characteristics in the Vertical-Alignment (VA)-In Plane Swiching (IPS) Cell on a Homeotropic Photopolymer Surface (수직 광폴리머 표면을 이용한 VA-IPS 셀의 전기 광학 특성)

  • Pieh, Sung-Hoon;Hwang, Jeoung-Yeon;Kim, Jae-Hyung;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.945-948
    • /
    • 2002
  • We studied electro-optical (EO) performances of a vertical-alignment (VA)-in plane switching (IPS) cell on a photopolymer surfaces. The VA-IPS cell, dark in voltage-off state, reveals bright uniformity in all directions due to the dual domainlike dierector configuration in the voltage-on state. For voltage-transmittance (V-T) measurement, the transmittance characteristics of the VA-IPS cell on the photopolymer surface was better than that of the VA-IPS cell on a polyimide(PI) surface.

  • PDF

Influence of vertical load on in-plane behavior of masonry infilled steel frames

  • Emami, Sayed Mohammad Motovali;Mohammadi, Majid
    • Earthquakes and Structures
    • /
    • v.11 no.4
    • /
    • pp.609-627
    • /
    • 2016
  • Results of an experimental program are presented in this paper for the influence of vertical load on the in-plane behavior of masonry infilled steel frames. Five half-scaled single-story, single-bay steel frame specimens were tested under cyclic lateral loading. The specimens included four infilled frames and one bare frame. Two similar specimens as well as the bare frame had moment-resisting steel frames, while the remaining two specimens had pinned steel frames. For each frame type, one specimen was tested under simultaneous vertical and lateral loading, whereas the other was subjected only to lateral loading. The experimental results show that the vertical load changes the cracking patterns and failure modes of the infill panels. It improves dissipated hysteresis energy and equivalent viscous damping. Global responses of specimens, including stiffness and maximum strength, do no change by vertical loading considerably. Regarding the ductility, the presence of vertical load is ignorable in the specimen with moment-resisting frame. However, it increases the ductility of the infilled pinned frame specimen, leading to an enhancement in the m-factor by at least 2.5 times. In summary, it is concluded that the influence of the vertical load on the lateral response of infilled frames can be conservatively ignored.

Proposed parameters of optimal central incisor positioning in orthodontic treatment planning: A systematic review

  • Sangalli, Linda;Dalessandri, Domenico;Bonetti, Stefano;Mandelli, Gualtiero;Visconti, Luca;Savoldi, Fabio
    • The korean journal of orthodontics
    • /
    • v.52 no.1
    • /
    • pp.53-65
    • /
    • 2022
  • Objective: Planning of incisal position is crucial for optimal orthodontic treatment outcomes due to its consequences on facial esthetics and occlusion. A systematic summary of the proposed parameters is presented. Methods: Studies on Google Scholar©, PubMed©, and Cochrane Library, providing quantitative information on optimal central incisor position were included. Results: Upper incisors supero-inferior position (4-5 mm to upper lip, 67-73 mm to axial plane through pupils), antero-posterior position (3-4 mm to Nasion-A, 3-6 mm to A-Pogonion, 9-12 mm to true vertical line, 5 mm to A-projection, 9-10 mm to coronal plane through pupils), bucco-lingual angulation (4-7° to occlusal plane perpendicular on models, 20-22° to Nasion-A, 57-58° to upper occlusal plane, 16-20° to coronal plane through pupils, 108-110° to anterior-posterior nasal spine), mesio-distal angulation (5° to occlusal plane perpendicular on models). Lower incisors supero-inferior position (41-48 mm to soft-tissue mandibular plane), antero-posterior position (3-4 mm to Nasion-B, 1-3 mm to A-Pogonion, 12-15 mm to true vertical line, 6-8 mm to coronal plane through pupils), bucco-lingual angulation (1-4° to occlusal plane perpendicular on models, 87-94° to mandibular plane, 68° to Frankfurt plane, 22-25° to Nasion-B, 105° to occlusal plane, 64° to lower occlusal plane, 21° to A-Pogonion), mesio-distal angulation (2° to occlusal plane perpendicular on models). Conclusions: Although these findings can provide clinical guideline, they derive from heterogeneous studies in terms of subject characteristics and reference methods. Therefore, the optimal incisal position remains debatable.