• 제목/요약/키워드: vertical displacement

검색결과 1,049건 처리시간 0.03초

Ground Reaction Force Characteristics During Forward and Backward Walking Over 20 Degree Ramp (20° 경사로 앞.뒤 보행 동작 시 지면반력의 형태 비교 분석)

  • Chae, Woen-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • 제18권3호
    • /
    • pp.71-82
    • /
    • 2008
  • W. S. CHAE, Ground Reaction Force Charateristics During Forward and Backward Walking Over 20 Degree Ramp. Korean Journal of Sport Biomechanics, Vol. 18, No. 3, pp. 71-82, 2008. The purpose of this study was to compare GRF characteristics during forward and backward walking over 20 degree ramp. Temporal parameters, GRFs, displacement of center of pressure (DCP), and loading and decay rates were determined for each trial. The results showed that the vertical GRF in BD during RTO was significantly greater than those found in FU. This reults indicated that GRF patterns may be changed by different walking conditions and altering position of ankle, knee, and center of mass throughout the walking cycle. The DCP during $RHC_2$-LHC in antero-posterior direction for downward was smaller than the corresponding value for upward condition. It' seems that the ankle and knee joints are locked in an awkward fashion at the toe contact to compensate for imbalance. Reducing the magnitude of loading rate can be achieved by walking in the backward direction. Accordingly, the results can be a benefit if one is suffering from an impact-type injury.

Design and Analysis of Section-divided Circular Composite Wing Spar (단면분할 원통형 복합재료 날개 보 설계 및 해석)

  • Kim, Ki-Hoon;Koo, Kyo-Nam
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • 제47권10호
    • /
    • pp.687-694
    • /
    • 2019
  • A circular composite spar in the wing of ultra-light aircraft is subjected to both bending moment and transverse shear loads. However, the beam being used in the aircraft may be inefficient because the design would not take into account the characteristics of the circular tube that supports the bending moment in top and bottom arc parts and the transverse load in left and right ones. Therefore, it is necessary to efficiently fabricate the circular tube beam by properly selecting the stacking sequences or the laminated composite structure. In order to increase both bending and transverse shear strengths of the beams, in this study, a cross-section of circular tube is divided into four arcs: top, bottom, left and right ones. The commercial program, MSC/NASTRAN is used to calculate vertical displacement and the normal and shear strains with variation of parameters such as division angle of arc and fiber orientation. Based on the results, the effective parameters for the new circular composite beam are presented to increase its bending and shear strengths.

Two-dimensional deformation measurement in the centrifuge model test using particle image velocimetry

  • Li, J.C.;Zhu, B.;Ye, X.W.;Liu, T.W.;Chen, Y.M.
    • Smart Structures and Systems
    • /
    • 제24권6호
    • /
    • pp.793-802
    • /
    • 2019
  • The centrifuge model test is usually used for two-dimensional deformation and instability study of the soil slopes. As a typical loose slope, the municipal solid waste (MSW) landfill is easy to slide with large deformation, under high water levels or large earthquakes. A series of centrifuge model tests of landfill slide induced by rising water level and earthquake were carried out. The particle image velocimetry (PIV), laser displacement transducer (LDT) and marker tracer (MT) methods were used to measure the deformation of the landfill under different centrifugal accelerations, water levels and earthquake magnitudes. The PIV method realized the observation of continuous deformation of the landfill model, and its results were consistent with those by LDT, which had higher precision than the MT method. The deformation of the landfill was mainly vertically downward and increased linearly with the rising centrifugal acceleration. When the water level rose, the horizontal deformation of the landfill developed gradually due to the seepage, and a global slide surface formed when the critical water level was reached. The seismic deformation of the landfill was mainly vertical at a low water level, but significant horizontal deformation occurred under a high water level. The results of the tests and analyses verified the applicability of PIV in the two-dimensional deformation measurement in the centrifuge model tests of the MSW landfill, and provide an important basis for revealing the instability mechanism of landfills under extreme hydraulic and seismic conditions.

Analysis of Influence on Derailment due to Primary Spring Aging (축상스프링 노화에 따른 탈선안전도 영향 분석)

  • Hur, Hyunmoo;Shin, Yujeong;You, Wonhee;Park, Joonhyuk
    • Journal of the Korean Society for Railway
    • /
    • 제20권3호
    • /
    • pp.320-328
    • /
    • 2017
  • In order to analyze the influence on derailment safety according to the aging of primary rubber springs widely applied to railway vehicles, characteristic tests were carried out on aged primary rubber spring samples. To analyze the effect of primary rubber spring aging on derailment safety, a vehicle dynamic analysis was carried out. The results of the vertical characteristics test for the rubber spring specimens with 17 years of service life revealed that the displacement restoration function was degraded due to rubber aging and the spring stiffness significantly increased. The results of the running dynamic analysis simulating the twist track running in accordance with the EN14363 standard, compared with the normal vehicle model (Case 1), showed that the derailment coefficient and the wheel unloading of the vehicle model (Case 2) using the aging primary spring characteristic increased, and the derailment safety was degraded. IN particular, it was found that the derailment safety due to the reduction of the wheel load is weak in the transient section where a steep slope change occurs.

MEASUREMENT OF NUCLEAR FUEL ROD DEFORMATION USING AN IMAGE PROCESSING TECHNIQUE

  • Cho, Jai-Wan;Choi, Young-Soo;Jeong, Kyung-Min;Shin, Jung-Cheol
    • Nuclear Engineering and Technology
    • /
    • 제43권2호
    • /
    • pp.133-140
    • /
    • 2011
  • In this paper, a deformation measurement technology for nuclear fuel rods is proposed. The deformation measurement system includes a high-definition CMOS image sensor, a lens, a semiconductor laser line beam marker, and optical and mechanical accessories. The basic idea of the proposed deformation measurement system is to illuminate the outer surface of a fuel rod with a collimated laser line beam at an angle of 45 degrees or higher. For this method, it is assumed that a nuclear fuel rod and the optical axis of the image sensor for observing the rod are vertically composed. The relative motion of the fuel rod in the horizontal direction causes the illuminated laser line beam to move vertically along the surface of the fuel rod. The resulting change of the laser line beam position on the surface of the fuel rod is imaged as a parabolic beam in the high-definition CMOS image sensor. An ellipse model is then extracted from the parabolic beam pattern. The center coordinates of the ellipse model are taken as the feature of the deformed fuel rod. The vertical offset of the feature point of the nuclear fuel rod is derived based on the displacement of the offset in the horizontal direction. Based on the experimental results for a nuclear fuel rod sample with a formation of surface crud, an inspection resolution of 50 ${\mu}m$ is achieved using the proposed method. In terms of the degree of precision, this inspection resolution is an improvement of more than 300% from a 150 ${\mu}m$ resolution, which is the conventional measurement criteria required for the deformation of neutron irradiated fuel rods.

Numerical Analysis of Behavior of Ground Near LNG Tank Foundation Under Scenario of LNG Leakage (LNG 탱크에서 천연가스 유출시 얕은 기초 주변 지반거동의 수치해석적 분석)

  • Kim, Jeongsoo;Kim, Youngseok;Lee, Kicheol;Kim, Dongwook
    • Journal of the Korean Geosynthetics Society
    • /
    • 제17권4호
    • /
    • pp.81-92
    • /
    • 2018
  • Recently, the use of natural gas has steadily increased due to its economical advantage and increased demand of clean energy uses. Accordingly, construction of LNG storage tanks is also increased. Secure of the stability of LNG tanks storage requires high technology as natural gas is stored in a liquid state for efficiency of storage. When a cryogenic LNG fluid leaks on ground due to a defect in LNG tank, damage is expected to be significant. Many researchers evaluated the critical and negative effects of LNG leakage, but there is limited research on the effect of cryogenic fluid leakage on the ground supporting LNG tanks. Therefore, in this study, the freezing expansion of the ground during cryogenic LNG fluid leakage was evaluated considering various outflow situations and ground conditions. The LNG leakage scenarios were simulated based on numerical analyses results varying the surcharge load, temperature boundary conditions, and soil types including freeze-sensitive soil. Consequently, short and long term ground temperature variations after LNG leakage were evaluated and the resulting ground behavior including vertical displacement behavior and porosity were analyzed.

Small- and large-scale analysis of bearing capacity and load-settlement behavior of rock-soil slopes reinforced with geogrid-box method

  • Moradi, Gholam;Abdolmaleki, Arvin;Soltani, Parham
    • Geomechanics and Engineering
    • /
    • 제18권3호
    • /
    • pp.315-328
    • /
    • 2019
  • This paper presents an investigation on bearing capacity, load-settlement behavior and safety factor of rock-soil slopes reinforced using geogrid-box method (GBM). To this end, small-scale laboratory studies were carried out to study the load-settlement response of a circular footing resting on unreinforced and reinforced rock-soil slopes. Several parameters including unit weight of rock-soil materials (loose- and dense-packing modes), slope height, location of footing relative to the slope crest, and geogrid tensile strength were studied. A series of finite element analysis were conducted using ABAQUS software to predict the bearing capacity behavior of slopes. Limit equilibrium and finite element analysis were also performed using commercially available software SLIDE and ABAQUS, respectively to calculate the safety factor. It was found that stabilization of rock-soil slopes using GBM significantly improves the bearing capacity and settlement behavior of slopes. It was established that, the displacement contours in the dense-packing mode distribute in a broader and deeper area as compared with the loose-packing mode, which results in higher ultimate bearing load. Moreover, it was found that in the loose-packing mode an increase in the vertical pressure load is accompanied with an increase in the soil settlement, while in the dense-packing mode the load-settlement curves show a pronounced peak. Comparison of bearing capacity ratios for the dense- and loose-packing modes demonstrated that the maximum benefit of GBM is achieved for rock-soil slopes in loose-packing mode. It was also found that by increasing the slope height, both the initial stiffness and the bearing load decreases. The results indicated a significant increase in the ultimate bearing load as the distance of the footing to the slope crest increases. For all the cases, a good agreement between the laboratory and numerical results was observed.

The Optimal Isolation Period of Vertically Story-added Remodeling Apartment Building with Seismic Isolation System (면진시스템을 적용한 수직증축 리모델링 공동주택의 최적 면진주기 산정)

  • Hur, Moo-Won;Lee, Yong-Hun;Lee, Sang-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • 제23권3호
    • /
    • pp.65-74
    • /
    • 2019
  • This study presents the optimal isolation period according to the number of vertically expended stories in order to provide the basic data for the application of the seismic isolation system in the vertically expended remodeling of the aged apartment. As a result of the structural analysis, the isolation period should be at least twice the primary structure in three-story vertical expansion, three times in two-story expansion, and four times in one-story expansion for the effective application of the isolation system. On the basis of the result, the efficacy of an isolation system for the actual apartment structure, which is three-story vertically expended, was analytically verified. The maximal acceleration response on the top floor reduced by 70% and 65% of the non-isolated structure in the X and Y directions respectively. Additionally, the base shear force decreased by 30% in the both directions, compared to the non-isolated structure.

Overtopping Model Experiments and 3-D Seepage Characteristics of the Embankment of Deteriorated Homogeneous Reservoirs (노후화된 균일형 저수지 제체의 월류모형실험과 3차원 침투특성)

  • Lee, Young Hak;Lee, Tae Ho;Lee, Dal Won
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • 제61권2호
    • /
    • pp.13-23
    • /
    • 2019
  • In this study, an overtopping model experiments and three dimensional seepage characteristics at the deteriorated homogeneous reservoirs were performed to investigate the behavior of failure for embankment and spillway transitional zone due to overtopping. The failure pattern, pore water pressure, earth pressure and settlement by overtopping were compared and analyzed. The pattern of the failure by overtopping was gradually enlarged towards reservoirs crest from the spillway transition zone at initial stage. In the rapid stage and peak stage, the width and depth of failure gradually increased, and the pattern of the failure appeared irregular and several direction of the erosion. In the early stage, the pore water pressure at spillway transitional zone was more affected as its variation and failure width increased. In the peak stage, the pore water pressure was significantly increased in all locations due to the influence of seepage. The earth pressure increased gradually according to overtopping stage. The pore pressure by the numerical analysis was larger than the experimental value, and the analysis was more likely to increase steadily without any apparent variation. The horizontal and vertical displacements were the largest at the toe of slope and at the top of the dam crest, respectively. The results of this displacement distribution can be applied as a basis for determining the position of reinforcement at the downstream slope and the crest. The collapse in the overtopping stage began with erosion of the most vulnerable parts of the dam crest, and the embankment was completely collapsed as the overtopping stage increased.

Hydraulic-Mechanical Modeling on Fracture Transmissivity Evolution Around a Borehole (시추공 주변 단열 투수도 진화에 대한 수리-역학 연동 모델링 평가)

  • Choi, Chae-Soon;Park, Kyung-Woo;Park, Byeong-Hak;Ko, Nak-Youl;Ji, Sung-Hoon
    • The Journal of Engineering Geology
    • /
    • 제31권1호
    • /
    • pp.55-66
    • /
    • 2021
  • Hydraulic-mechanical (H-M) coupled numerical modeling was used to evaluate the evolution of hydrogeological properties in response to the installation and expansion of a borehole. A domain with a discrete fracture network was adopted for discontinuum modeling to simulate changes in fracture apertures. Comparison with real hydraulic test data shows that the effects of principal stress direction and expansion of borehole diameter were reasonably simulated by H-M coupled numerical modeling. The modeling confirmed that aperture changes depended on the principal stress direction, with an increase in aperture size due to vertical displacement being the dominant effect. A concentration of shear dilation around the borehole had an additional, subsidiary, effect on the hydrogeological evolution. These results show that the permeability of fractured rock can be increased by changing the hydraulic properties of a fracture through stress redistribution caused by the installation and expansion of a borehole.