• Title/Summary/Keyword: venturi system

Search Result 70, Processing Time 0.032 seconds

Development of a Low -Cost and Precise Liquid Metering Device for Automatic Nutrient-Solution Control (양액 자동조제용 액제 정밀계량 장치 개발)

  • 이정훈;류관희;이규철
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1997.12a
    • /
    • pp.255-262
    • /
    • 1997
  • A low-cost and precise metering device, which is suitable to automatic mixing of nutrient-solution for hydroponic culture, was developed for small-scale growers. The metering device was composed of three parts those were supply pumps, metering cylinders and venturi tube. Those parts were controlled by personal computer with time-based odoff control method. To verify the performance of the developed metering device, the relationship between operating time and discharge was examined and the accuracy of the developed metering device was compared with commercial metering pumps. The results of this study are as follows. 1. The correlation coefficient between the flow rate and operating time was 0.9999, and the linear regression equation computed was y=21.759x, where y is the discharge(g) and x is the operating time(s). 2. The developed device has greater accuracy than commercial metering pumps in terms of the full-scale error. Calculated errors for the developed metering device and two commercial pump were $\pm$0.3 %, $\pm$2.45 % and $\pm$1.38 % respectively. 3. Above results show developed metering device is a useful tool for nutrient-solution control system.

  • PDF

A Study on Proportion-Generating System Based on Dom Hans van der Laan′s Proportion Theory (돔 한스 반 데어 란의 비례론에 기초한 비례생성 시스템에 관한 연구)

  • Choo Seung Yeon
    • Journal of the Korean housing association
    • /
    • v.15 no.5
    • /
    • pp.69-76
    • /
    • 2004
  • 비트루비우스(Vitruvius)에서 벤츄리(Venturi)에 이르기까지 많은 건축사가(建榮史家) 또는 건축가(建築家)들이 건축원리에 대한 각자의 규범적 태도를 글로써 밝혀왔다. 이러한 규범적 내용 중 비례이론은 서양건축에 있어 건축미(建築美) 비밀로 간주되어, 조화로운 건축물이 꼭 갖추어야 할 덕목중의 하나로 인식되었다. 현대건축에서 비교적 근대 비례시스템이라 불릴 수 있는 것으로 르 꼬르뷔지에의 모될로르와 반 데어 란의 플라스틱 넘버를 들 수 있다. 모될로르는 현재까지 아주 제한된 성공밖에 거두지 못했는데, 이는 피보나치 수열에 기초한 수치들이 커졌을 때 단위의 배수관계가 거의 형성되지 않는다는 사실에 기인한다. 반면에 플라스틱 넘버는 모될로르의 결점들을 보완할 수 있는 매력적인 수열을 가지고 있다. 이에 본 연구는 반 데어 란의 비례시스템 분석을 통하여 유도된 수열규칙이 건축디자인과 관련되어 직접적으로 적용되어 질 수 있는 CAAD시스템을 제안한다. 본 시스템의 초점은 반 데어 란의 비례이론이 어떻게 컴퓨터 언어로 변환 및 CAAD시스템에 적용되어, 실질적인 건축 실무행위에 있어 컴퓨터가 디자인 도우미로서 역할을 수행할 수 있겠는가하는 것이다. 연구의 결과, 사용자는 이러한 시스템을 사용함으로써 반 데어 란의 비례시스템을 자신의 디자인에 손쉽게 적용할 수 있으며, 이는 복잡한 치수관계로 구성된 비례시스템의 건축실무 활용으로 발전되어질 수 있을 것으로 사료된다.

Flow instability of cryogenic fluid in the downstream of orifice (극저온 유체의 공동 발생에 의한 오리피스 후류의 유동 불안정)

  • Lee, Se-Young;Lee, Chang-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.7
    • /
    • pp.695-702
    • /
    • 2008
  • Flow instability in the rocket turbo pump systems can be caused by various elements such as valve, orifice and venturi and etc. The formation of cavitation specially in the propellant feeding system can trigger the mass flow and pressure oscillation due to cyclic formation and depletion of cavitations. If the cryogenic propellant are used, which is very sensitive to temperature variation, the change of propellant properties due to thermodynamic effect should be accounted for in the flow analysis. This study focuses on the formation of cryogenic cavitation adopting MUSHY IDM model suggested by Shyy and coworkers. Also, the flow instability is investigated with developed numerical code in the downstream of orifice flow. To this end, three different orifices are selected and investigated by the numerical calculation.

Analysis of Air Current Characteristics for Installing Wind Turbines Between Buildings (건물 사이에 풍력발전기를 설치하기 위한 기류특성분석)

  • Park, Min-Woo;You, Jang-Youl;Sohn, Young-Moo;You, Ki-Pyo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.1
    • /
    • pp.117-125
    • /
    • 2018
  • Recently, various building integrated wind power (BIWP) approaches have been used to produce energy by installing wind power generators in high-rise buildings constructed in urban areas. BIWP has advantages in that it does not require support to position the turbine up to the installation height, and the energy produced by the wind turbine can be applied directly to the building. The accurate evaluation of wind speed is important in urban wind power generation. In this study, a wind tunnel test and computational fluid dynamics (CFD) analysis were conducted to evaluate the wind speed for installing wind turbines between buildings. The analysis results showed that the longer the length of the buildings, which had the same height, the larger the wind speed between the two buildings. Furthermore, the narrower the building's width, the higher the wind velocity; these outcomes are due to the increase in the Venturi effect. In addition, the correlation coefficient between the results of the wind tunnel test and the CFD analysis was higher than 0.8, which is a very high value.

A Study on Foam Mixing Characteristics in Steady State to Enhance the Performance of Proportioner for Foam System (포 소화설비용 소화약제 혼합장치의 성능향상을 위한 정량 혼합특성에 관한 연구)

  • Ku, Jae-Hyun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.5
    • /
    • pp.63-68
    • /
    • 2009
  • This study describes to analyze foam mixing characteristics in steady state to enhance the performance of proportioner for foam system designed to accurately proportion a foam liquid concentrate into a water stream up to constant concentration. The proportioner developed is experimentally evaluated in performance evaluation system consisted of a pump, tanks, pressure gauges, flow meters, a nozzle. As a result, the foam mixing performance of the line proportioner is found to increase with increased the water flow rate due to the venturi effect and with increased the cross-sectional area of the orifice and is analysed with 3 % in the error rate of $\pm4%$. For the pressure proportioner, the foam mixing performance is analyzed to increase with increased the water flow rate and with increased the inlet pressure and is analysed with 3% in the error rate of $\pm2%$.

Development of Automatic Nutrient-Solution Mixing System Using a Low-Cost and Precise Liquid Metering Device (액제 정밀계량 장치를 이용한 양액 자동조제 시스템 개발)

  • 이규철;류관희;이정훈;김기영;황호준
    • Journal of Biosystems Engineering
    • /
    • v.22 no.4
    • /
    • pp.469-478
    • /
    • 1997
  • This study was conducted to develop an automatic nutrient-solution mixing system for small-scale sewers. The nutrient-solution mixing system consisted of a low-cost and precise metering device and data acquisition & control system with a personal computer. and, the metering device was composed of three parts those were supply pumps, metering cylinders and venturi tube. The system controlled electric conductivity(EC) and pH of nutrient-solution based on the time-based feedback control method with the information about temperature, EC, and pH of the nutrient-solution. The performance of the nutrient-solution mixing system was evaluated through the control of EC and pH while compared with those of commercial system. Also an experimental cultivation of tomato was conducted to verify and to improve the developed system. Results of this study were as follows. 1. The correlation coefficient of meteing device between the flow rate and operating time was 0.9999, and the linear reuession equation computed was y=21.759x, where y is the discharge($g$) and x is the operating time(s). 2. Calculated errors for the developed metering device and two commercial pump were $\pm$0.3% $\pm$2.45% and $\pm$1.38 % FS error respectively. 3. An automatic nutrient-solution mixing system based on a low-cost and precise metering device was developed. 4. The full scale errors of the developed system in controlling EC and pH at 23$\pm$1$^{\circ}C$ were $\pm$0.05mS/cm and $\pm$0.2, respectively 5. When using the commercial system, the controlled values of EC and pH of the 500 $\ell$ of water were 1.29 mS/cm and 6.1 pH for the setting points of 1.4 mS/cm and 6.0 pH respectively at 23$pm1^{\circ}C$. 6. The developed nutrient-solution control system showed $\pm$0.05 ms/cm of deviation from the setting EC value over the experimental cultivation period. 7. The deviation from the average values of Ca and Mg mass content in the several nutrient-solution were 0.5% and 1.8% respectively.

  • PDF

A Study on the Collision Nozzle for Generating Microbubble by Self-Suction Method (자흡방식에 의해 마이크로버블을 발생시키는 충돌 노즐에 대한 연구)

  • Woo-Jin Kang;Sang-Hee Park;Seong-Hun Yu
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_2
    • /
    • pp.1047-1053
    • /
    • 2023
  • An experimental study was performed on the collision nozzle system that generates microbubble by air self-suction using a venturi nozzle. This study experimentally investigates the pressure of a pump and a dissolution tank, water flow rate, air self-suction amount and microbubble generation amount. The experimental conditions were varied by changing the diameter of the collision nozzle (de=4,5,6,7,8mm), the pumping power(0.5hp, 1.0hp) and the capacity of the dissolution tank(4.4L, 8/8L). The pressure change of the pump according to the outlet diameter of the collision nozzle showed that the 1.0hp pump power operated more stably than the 0.5hp pump. The pressure change in the dissolution tank was shown to decrease rapidly as the outlet diameter of the nozzle increased. The flow rate of recirculating water was shown to increase as the nozzle diameter increased. Additionally, it was shown that the pump capacity of 1.0hp increased the flow rate more than that of 0.5hp. The self-suction air flow rate was shown to occur above de=6mm, and the air flow rate increased as the nozzle diameter increased. Also, as the pump capacity increased, the self-suction amount of air increased. It was shown that the amount of microbubble less than 50mm generated was maximum when the nozzle diameter was 6mm, the pump power was 1.0hp, and the dissolution tank capacity was 8.8L.

Experimental and CFD Study on the Exhaust Efficiency of a Smoke Control Fan in Blind Entry Development Sites (맹갱도 굴진 작업공간내 방재팬의 화재연 배기효율에 관한 현장실험 및 CFD 연구)

  • Nguyen, Vanduc;Kim, Dooyoung;Hur, Wonho;Lee, Changwoo
    • Tunnel and Underground Space
    • /
    • v.28 no.1
    • /
    • pp.38-58
    • /
    • 2018
  • The ventilation system plays a crucial role in underground mine safety. The main objective of the ventilation system is to supply sufficient air to dilute the contaminated air at working places and consequently provide tenable environment during the normal operation, while it also should be capable of controlling the fire propagation and facilitate rescue conditions in case of fire in mines. In this study, a smoke control fan was developed for the auxiliary ventilation as well as the fire smoke exhaust. It works as a free-standing auxiliary fan without tubing to dilute or exhaust the contaminated air from the working places. At the same time, it can be employed to extract the fire smoke. This paper aims to examine the smoke control efficiency of the fan when combined with the current ventilation system in mines. A series of the site experiments and numerical simulations were made to evaluate the fan performance in blind entry development sites. The tracer gas method with SF6 was applied to investigate the contaminant behavior at the study sites. The results of the site study at a large-opening limestone mine were compared with the CFD analysis results with respect to the airflow pattern and the gas concentration. This study shows that in blind development entry, the most polluted and risky place, the smoke fan can exhaust toxic gases or fire smoke effectively if it is properly combined with an additional common auxiliary fan. The venturi effect for smoke exhaust from the blind entry was also observed by the numerical analysis. The overall smoke control efficiency was found to be dependent on the fan location and operating method.

An Experimental Study on the Improvement of Foam Fire-Extinguishing System's Mixing Ratios by Expanding the Cross Sectional Area of the Stock Solution Inhaling Piping (원액흡입배관 단면적 확장에 의한 포 소화설비 혼합비 개선에 관한 실험적 연구)

  • Yun, Ki-Jo;Jang, Kyung-Nam;Baek, Eun-Sun;Park, Bong-Rae;Park, Hee-Joog
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.30-37
    • /
    • 2013
  • The ultimate purpose of the present study is to secure a effective method for foam liquid discharge when the mixing ratio deviates from the permissible range due to a decrease in the bypass flow rate resulting from a decrease in the cross sectional area of the foam liquid piping ranging from the branching header of one foam proportioner to the branching headers of multiple branching foam fire-extinguishing systems in the region for fire extinguishing and then to the standpipe at the lower part of the storage tank when a fire occurred in a combustible tank. To this end, the cause of mixing ratio variations following changes in the flow rates of existing foam fire extinguishing systems was analyzed, methods for compensation for constant mixing ratios were investigated, and it was proved that metering orifice replacements that could expand the cross sectional area of the stock solution inhaling piping was the most effective way for the improvement of form fire extinguishing systems' mixing ratios through foam proportioner venturi, foam chamber orifice, and metering orifice replacement experiments.

Effect of the Application of a Suspended and a Mixing-in-Pipe Type Aerator on the Liquid Fertilization of Pig Manure Slurry (현수, 배관 내 혼합 폭기방식 적용이 돼지분뇨 슬러리의 액상 비료화에 미치는 영향)

  • Jeong, Kwang Hwa;Kim, Jung-Kon;Khan, Modabber Ahmed;Kwag, Jung-Hoon;Han, Duk-Woo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.22 no.4
    • /
    • pp.62-71
    • /
    • 2014
  • Three types of diffuser systems were manufactured and applied to investigate the effect of liquid fertilization of pig manure slurry by application of aeration processes. In the first type reactor, commonly used diffuser system, which diffuse air upward by diffusing aerator fixed at the bottom of the reactor is installed. In case of the second type, air diffuser is installed 10 cm above of the bottom of a reactor. In the third type reactor, the venturi-type air diffuser is installed at circulation pipe, which return pig slurry in the reactor(mixing-in-pipe process). The pig manure slurry separated to solid/liquid was flowed into the experimental reactor, and left as it for one week to precipitate solids. The concentration of organic matter, T-N, T-P and BOD in the raw pig manure slurry flowed into the reactor of bottom-fixed type aeration process were 1.82%, 4,400 mg/L, 360 mg/L and 13,542 mg/L, respectively. After aeration the concentration of organic matters, T-N, T-P and BOD in the slurry were 2.01%, 4,400 mg/L, 420 mg/L and 16,824 mg/L, respectively. The concentration of organic matter, T-N, T-P and BOD in the mixing-in-pipe type changed from 1.58%, 3,700 mg/L, 260 mg/L and 15,735 mg/L to 1.96%, 4,000 mg/L, 340 mg/L, and 18,098 mg/L, respectively. Changes of the concentration of organic matter, T-N, T-P and BOD of the pig manure slurry collected from the middle layers of two aeration reactors; bottom aeration process and the mixing-in-pipe process, were 10.4%, 0%, 16.7% and 24.2% and 24.0%, 8.1%, 30.8% and 15.0%, respectively. The thickness of foam layer generated on the surface of pig manure slurry in aeration tank was thinner in mixing-in-pipe reactor than bottom-fixed type aeration reactor.