일부 탈지세척 및 도금공정 국소배기장치의 성능점검과 개선방안 (Performance of Local Exhaust Ventilation Systems of Degreasing and Plating Workplaces)

  • 한돈희
    • 한국산업보건학회지
    • /
    • 제8권2호
    • /
    • pp.178-185
    • /
    • 1998
  • In order to evaluate and improve the performance of local exhaust ventilation systems for two TCE degreasing (A, B) and two electroplating (C, E) and one acid dipping & plating (D) operations located in Kimhae, the performance test was conducted with trace gases and a thermal anemometer (Kanomax 24-6111, Japan). For the inadequately designed systems, the improvement and redesigns in compliance with recommendation by ACGIH was suggested. The results of performance test for each system are as follows; 1. System of Workplace A was generally well-designed. Actual exhaust air flow rate was in excess of 68% above the recommended standard exhaust air flow rate. 2. System of Workplace B was very well-designed and completely enclosed. 3. All systems of Workplace C including hoods were poorly-designed and actual exhaust air flow rates were insufficient for open tanks. All systems should be upgraded according to ACGIH recommendations. 4. Supply and exhaust air flow rate of push-pull exhaust systems in Workplace D should be greatly increased. The width of flange of dipping tank hood should be increased with the value suggested. 5. System of Workplace E was well-designed. Actual exhaust air flow rate was in excess of 54% above the required.

  • PDF

한지(韓紙)의 환기성능에 관한 실험적 연구 (The Experimental Study on the Efficiency of Ventilation of Korean Paper (Hanji))

  • 이종원;임정명
    • 설비공학논문집
    • /
    • 제16권5호
    • /
    • pp.482-489
    • /
    • 2004
  • The purpose of this study is to reevaluate the performance of Hanji as a architectural material. Recent studies report that one of the causes of the Sick-HouseㆍSick-Building Syndrome is due to the contaminants from interior materials and the lack of ventilation. In this study, the properties of Hanji are investigated. The major focuses of this research are (1) how efficient the Hanji is for ventilation of the house and (2) whether the usage of Hanji brings required ventilation volume to the house. According to the test results, differential pressure in the air and the amount of ventilation showed linear relationship. Test results differ from various kinds of Hanji. Since houses usually have double window system, Hanji can be used to the windows system, especially for inner part of double window system. It is suggested that the combination of Hanji windows for the inner part and glass windows for outer part is very effective, and offers a solution to improvement of indoor air quality and the lack of ventilation with passive ventilation that has less energy consumption.

터널 내 화재발생시 구난역 내의 연기 거동에 미치는 설계된 환기 영향에 대한 실험적 연구 (Experimental Study on the Designed Ventilation Effect on the Smoke Movement at Rescue Station fire in Railway Tunnel)

  • 김동운;이성혁;유홍선;윤성욱
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.163-167
    • /
    • 2008
  • In this study, the 1/35 reduced-scale model experiment were conducted to investigate designed ventilation effect on the smoke movement at rescue station fire in railway tunnel. A model tunnel with 2 mm thick, 10 m long, 0.19 m high and 0.26 m was made by using Froude number scaling law. The cross-passages installing escape door at the center were connected between incident tunnel and rescue tunnel. The n-heptane pool fires with heat release rate 698.97W were used as fire source. The fire source was located at the center and portal of incident tunnel as worst case. A operating ventilation system extracted smoke amount of 0.015 cms(cubic meters per second). The smoke temperature and CO gas concentration in cross-passage were measured to verify designed ventilation system. The result showed that, at center fire case without ventilation, smoke did not propagate to rescues station. In portal fire case, smoke spreaded to rescues station without ventilation. But smoke did not propagated to rescues station with designed ventilation.

  • PDF

소형 공동주택의 하이브리드 환기시스템 성능실험 연구 (A Study on the Performance Evaluation of the Hybrid Ventilation System for Small Apartment Houses)

  • 전주영;김길태;이종성;김상희
    • 설비공학논문집
    • /
    • 제20권10호
    • /
    • pp.696-701
    • /
    • 2008
  • From Feb. 2006, the ventilating systems with air exchange rate of over 0.7times/hour are installed at the apartment houses (over 100 units). Installation cost and maintenance cost are very important factors for ventilating system because consumers have to pay the expenses of that system. Especially small apartment needs more considerations because small apartment is comparatively the economically weak part. The purpose of this study is to the performance evaluation of the hybrid ventilation system for small apartment houses. Hybrid system 1 consists of natural ventilation system and duct type exhaust diffusers. Hybrid system 2 has natural ventilation system and toilet exhaust system with static pressure fan. Infiltration of test apartment houses with ventilation system is under 0.1 times/hour. Mean air age of hybrid system 1 is 1.52 hours and hybrid system 2 is 1.42 hours. Mean ventilation effectiveness of hybrid system 2(93%) is higher than that of hybrid system 1(81%).

학교 교실의 창호 배치 및 개방면적비에 따른 중간기 자연환기량 및 쾌적성 평가에 관한 연구 (A Study on Evaluation of Natural Ventilation Rate and Thermal Comfort during the Intermediate Season considering by Window Layout and Open Window Ratio)

  • 김여진;최정민
    • 대한건축학회논문집:구조계
    • /
    • 제35권9호
    • /
    • pp.207-214
    • /
    • 2019
  • Natural ventilation through openings such as windows in school buildings is an efficient resource for natural cooling during the intermediate season of the year. Because the natural ventilation uses the wind outside the building, the amount of ventilation will depend not only on the wind speed and wind direction but also on the window layout and open window ratio. Therefore, in this study, the natural ventilation plans of school classroom windows are divided into 4 types and 8 cases as shown in Table 1. The characteristics of cooling effect by natural ventilation are simulated by applying Energyplus's Airflow Network Model and the comfort of the occupants is evaluated by the number of hours included in the 80% acceptability range of the ASHRAE Standard 55-2010 adaptive comfort model for the weekdays (Monday-Friday) and the class hours (08: 00-19: 00). Based on the analysis results of the above, this study presents basic data related to classroom cooling plan using intermediate season natural ventilation.

주택의 실내공기질 개선 평가 방법 (Evaluation Method for Improvement Efficiency of Indoor Air Quality in Residence)

  • 양원호;손부순;임성국
    • 한국환경보건학회지
    • /
    • 제33권4호
    • /
    • pp.255-263
    • /
    • 2007
  • Indoor air quality is the dominant contributor to total personal exposure because most people spend a majority of their time indoors. The purposes of this study were to evaluate the alternative method for improvement of indoor air quality in house after coating titanium dioxide ($TiO_2$) photocatalyst for interior part of the house using nitrogen dioxide ($NO_2$) multiple measurements. To evaluate the alternative method in indoor environment, daily indoor and outdoor $NO_2$ concentrations of an apartment and a detached house were daily measured for consecutive 21 days in winter and summer, respectively, Another daily 21 measurements were carried out after $TiO_2$ coating on wall paper of interior part in houses. All $NO_2$ concentrations were measured by passive filter badges. Indoor air quality models using mass balance are useful tool to quantify the relationship between indoor air pollution levels, ambient concentrations, and explanatory variables. Using a mass balance model and linear regression analysis, penetration factor (ventilation rate divided by sum of ventilation rate and decay rate) and source strength factor (emission rate divided by sum of ventilation rate and decay rate) were calculated. Subsequently, the decay constants were estimated. In this study. magnitude of improvement of indoor air quality could be evaluated by decay constant.

양파 수확 후 예건 방법이 저장 중 부패에 미치는 영향 (Effects of Pre-drying Methods on Onion Bulb Rot During Storage)

  • 서전규
    • 한국식품저장유통학회지
    • /
    • 제9권3호
    • /
    • pp.277-281
    • /
    • 2002
  • 양파의 예건 방법 및 기간이 저장 중 부패에 미치는 영향을 구명하기 위하여 만생종인 창녕대고 품종을 이용하여 1997년~1998년의 2개년 동안 양파를 수확 후 노지 포장과조립식 간이하우스(통풍) 및 조립식 간이하우스(무통풍)에서 1~3일간 예건 후 저장하여 실험하였다. 예건 기간중의 최고기온은 무 통풍 하우스에서 가장 높았고 노지 포장에서 가장 낮았으며 특히 무통풍 하우스에서 1997년 처리 2일째 및 3일째와 1998년 처리 2일째는 41.6$^{\circ}C$이상의 고온을 경과하였다. 수확 후의 양파 수분함량은 90.3~89.5%이었으며, 예건 후에는 1997년에는 0.3~l.8%가 감소되었고, 1998년에는 0.2~2.6%가 감소되었으며, 감량정도는 노지에서 가장 많았고, 통풍하우스에서 가장 적었다. 저장기간 중 최고기온은 1997년이 평균 39.2$^{\circ}C$로서 1998년의 37.1$^{\circ}C$에 비해 높게 경과하였으며, 상대습도는 7월은 1997년에 79.3%로서 1998년의 72.7%에 비해 높았으며, 8월은 1998년이 79.1%로서 1997년의 78.2% 보다 오히려 높게 경과하였다. 처리간 부패 발생은 1997년은 저장초기에 부패가 많이 발생하였으나, 1998년은 저장 중기 이후에 부패가 많이 발생하였으며 1997년에 비해 1998년에 부패가 많이 발생하였다. 총 부패율은 통풍하우스에서 가장 낮았고 무통풍 하우스에서 가장 높았으며, 예건 기간은 길수록 부패경감 효과가 높았다. 이상의 결과를 볼 때 수확 후 저장 중 부패를 경감시키기 위해서는 통풍이 되는 하우스에서 1~2일 예건하거나 노지에서 2~3일 예건하는 것이 효과적인 것으로 판단된다.

무창자돈사의 환경요인 개선을 위한 변형환기시스템의 현장 평가 연구 (A Farm Scale Study on the Modified Ventilation System for Improving Environmental Factors in a Confined Nursery Pig Building)

  • 김헌태;고한종;김기연;서진귀구;최홍림
    • Journal of Biosystems Engineering
    • /
    • 제31권3호
    • /
    • pp.175-181
    • /
    • 2006
  • Nursery pig building is imperative to provide environmental conditions favorable to maintenance of piglet health and the efficiency of growth rate. To meet the ultimate goal, it is necessary to apply proper ventilation design and construction to a confinement livestock building. This study was conducted to investigate the performance of a modified ventilation system in terms of devised slot-inlet (modification I) and exhaust fan (modification II) to improve air change rate in a confined nursery pig building, with dimension of 5.9 m(W) ${\times}$ 12.6 m(L) ${\times}$ 2.2 m(H) in an Darby Genetic Station. The experiment was carried out in August, especially when the outdoor peak temperature were above $30^{\circ}C$ and the measured indoor environmental factors were temperature, air velocity, humidity and ammonia concentration which have been known to affect the piglet health and growth. There was no difference in indoor temperature between the original and modified ventilation systems, however the air velocity and ammonia concentration in confined nursery pig building with modified ventilation system were, in most cases, better performance than original ventilation system. Therefore, it was concluded that the slot-inlet system that kept indoor environmental factors pertinent and had an economic advantage, should be considered as a ventilation system for decreasing sensible heat from piglet in confined nursery pig building during extreme summer season.

구획모델을 이용한 주택에서 이산화질소의 발생강도 및 감소상수 동시 추정 (Estimation of Source Strength and Deposition Constant of Nitrogen Dioxide Using Compartment Model)

  • 양원호;손부순;손종렬
    • 한국환경보건학회지
    • /
    • 제31권4호
    • /
    • pp.260-265
    • /
    • 2005
  • Indoor air quality might be affected by source strength of indoor pollutants, ventilation rate, decay rate, outdoor level, and so on. Although technologies measuring these factors exist directly, direct measurements of all factors are not always practical in most field studies. The purpose of this study was to develop an alternative method to estimate the source strength and deposition constant by application of multiple measurements. For the total duration of 60 days, indoor and outdoor $NO_2$ concentrations every 3 days were measured in 30 houses in Seoul, Asan and Daegu. Using a compartment model by mass balance and linear regression analysis, penetration factor (ventilation divided by sum of air exchange rate and deposition constant) and source strength factor (emission rate divided by sum of air exchange rate and deposition constant) were calculated. Subsequently, the source strength and deposition constant were estimated. Natural ventilation was $1.80{\pm}0.42\;ACH,\;1.11{\pm}0.50\;ACH,\;0.92{\pm}0.26\;ACH$ in Seoul, Asan and Daegu, respectively. Calculated deposition constant(K) and source strength of $NO_2,$ in this study were $0.98{\pm}0.28\;hr^{1}\;and\;16.28{\pm}7.47\;ppb/h,$ respectively.

기계 환기시스템의 실내 환기성능 특성 해석에 관한 연구 (A Study on Characteristic Analysis for Indoor Ventilation Performance of Mechanical Ventilation System)

  • 구재현
    • 한국가스학회지
    • /
    • 제16권2호
    • /
    • pp.31-37
    • /
    • 2012
  • 본 연구는 실내 쾌적성 제어를 위하여 룸 에어컨의 환기성능을 분석한다. 실험장치는 환경공조챔버, 룸 에어컨, 추적가스 측정시스템, 급기팬과 제어기로 구성된다. 환기성능은 ASTM Standard E741-83 기준에 근거하여 환경공조챔버 내 CO2 추적가스기법을 사용한 체강법에 의해 재실자와 급기 환기량에 따라 평가된다. 급기 환기량 증가에 따라 환기성능이 증가함을 파악하였으며 재실자가 없는 경우 CO2 가스는 빠르게 감소하며 이때의 환기성능은 55%까지 증가한다. 그리고 1명의 재실자가 있는 경우 1시간 경과후 급기량 570 lpm에서 환기성능은 자연감쇠와 비교하여 25%까지 증가한다. 실험 데이터를 사용하여 환경공조챔버 내 룸 에어컨의 환기성능 모델링을 도출하였다.