• 제목/요약/키워드: value position

검색결과 2,217건 처리시간 0.029초

무지외반증 치료에서 근위 중족골 절골술과 원위 연부조직 교정술 후 종자골의 교정정도 (Correction of Sesamoid after Proximal Metatarsal Osteotomy and Distal Soft Tissue Procedure in Hallux Valgus)

  • 정화재;신헌규;장일성;이종근
    • 대한족부족관절학회지
    • /
    • 제9권1호
    • /
    • pp.74-80
    • /
    • 2005
  • Purpose: A retrospective review of the radiographs of the proximal metatarsal osteotomy and distal soft tissue procedure for hallux valgus, evaluating the correction of the tibial sesamoid, was undertaken. We evaluated the correlation between the reduction of the tibial sesamoid and the clinical outcomes. Materials and Methods: 17 patients (23 cases) with moderate to severe hallux valgus deformity underwent the proximal metatarsal osteotomy and distal soft tissue procedure. The preoperative and last follow-up radiographs were reviewed according to the tibial sesamoid grade classification recommended by the Research Committee of the American Orthopedic Foot and Ankle Society (AOFAS). We divided them into two groups according to the reduction of the tibial sesamoid. We anaylyzed the clinical outcomes in each group according to Mayo Clinic Forefoot Scoring System (FFSS). Results: In all of the patients, the preoperative tibial sesamoid position were grade 2 or greater. At the last follow-up, 52% (n=12) were grade 1 or less (Group I) and 48% (n=11) were grade 2 or greater (Group II). In group I, the forefoot score was improved from preoperative mean value of 32.0 points to final follow-up value of 66.3 points. In group II, the forefoot score was improved from preoperative mean value of 31.7 points to final follow-up value of 65.9 points. There was no statistical significance between postoperative, average scores in group I and II (p>0.05). Conclusion: The position of the tibial sesamoid was corrected insufficiently in almost half of all cases. In view of clinical outcomes, there was no significant difference between the corrected group and the other group.

  • PDF

SSU 부위의 유전자 염기서열 분석에 의한 한국연안에서 분리한 Cochiodinium polykrikoides Margalef와 Gyrodinium aurelum Hulburt 적조생물의 분자생물학적 연구 (Genetic Study of the Class Dinophyceae Including Red Tide Microalgae Based on a Partial Sequence of SSU Region : Molecular Position of Korean Isolates of Cochlodinium polykrikoides Margalef and Gyrodinium aureolum Hulburt)

  • Cho, Eun-Seob
    • 생명과학회지
    • /
    • 제14권4호
    • /
    • pp.593-607
    • /
    • 2004
  • 유해성 적조생물 Cochlodinium polykrikoides/Gyrodinium aurelum을 포함한 43 종류의 와편조류를 대상으로 SSU 부위 유전자를 분석했다. 유전자 염기서열에 의거한 상호 계통수는 parisomny, distance, maxium 방법으로 실행했다. Noctilura scintillans, Gonyaulax spinifera와 Crythecodinium cohnii 종들은 와편모조류 중 가장 유전적으로 먼 것으로 보였다. Alexandrium과 Symbiodinium 종간의 bootstrap는 70% 이상의 상호 단일 계통도를 보인 반면에, Gymnodinium과 Gyrodinium은 근립절약계수와 최대 유사도 방법에서 다형 계통도를 나타내었다. Gyroddinium aurelum과 G. dorsum/G. galathenum의 유전적 분화율은 7.4% (45 bp) 였고, G. aurelum과 G. mikimotoi 상호간에는 0.9% (5bp) 밖에 나타나지 않았다. 또한 C. polykrikoides와 G. aurelum도 5.2% (31bp)로 낮은 유전적 분화율을 보였다. 계통도를 분석한 결과 G. aureolum과 C. polykrikoides는 Gyrodinium 보다 Gymnodinim 속에 훨씬 더 근접하게 나타났다.

시각적 정보와 내측 쐐기 인솔의 높이 차이가 정상 성인의 슬관절 고유수용성 감각에 미치는 영향 (The Influences of Visual Information and Different Elevations of Medially Wedged Insoles on Knee Joint Proprioception in Healthy Persons)

  • 김도균;고은혜;이강성;신헌석
    • 한국전문물리치료학회지
    • /
    • 제12권1호
    • /
    • pp.22-27
    • /
    • 2005
  • The purpose of this study was to investigate the effects of visual information and different elevations of medially wedged insoles on the proprioceptive sense of the knee joint. The subjects of this study were 16 able-bodied men who were not athletic. An electrogoniometer was used to determine the error value between calculated 50% of full flexion (target position) and performed 50% of full flexion in a standing position with the upper extremities crossed. Tests were randomly performed in $2{\times}4$ conditions. Visual variations included open eyes vs. closed eyes, while the elevation was adjusted through the use (or lack thereof) of medially wedged insoles of 10 mm, 14 mm, and 18 mm. The average error value in each condition was statistically analyzed. The findings of this study revealed as follows: 1) The average error value was significantly higher with the subjects' eyes open than with their eyes closed (p<.05). 2) The averaged error value was also significantly higher when the subjects were elevated 18 mm than with no elevation at all (p<.05). The findings of this study should be considered in lower extremity rehabilitation programs when medially wedged insoles used.

  • PDF

Using Evolutionnary algorithms to Design Mobile Manipulators

  • Keigo, Watanabe;Lee, Min-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.44.4-44
    • /
    • 2001
  • A new approach to design and control mobile manipulators is presented in this paper, associating genetic algorithm to multicriteria optimization to generate and value the robots according to the constraints and aims of the task. Then the first step of this approach is detailed, as topologies and configurations of manipulators that can assume position, trajectory, speed or force task are studied.

  • PDF

ON SPATIAL DISTRIBUTION OF SHORT GAMMA-RAY BURSTS FROM EXTRAGALACTIC MAGNETAR FLARES

  • Chang, Heon-Young;Kim, Hee-Il
    • Journal of Astronomy and Space Sciences
    • /
    • 제19권1호
    • /
    • pp.1-6
    • /
    • 2002
  • Recently, one interesting possibility is proposed that a magnetar can be a progenitor of short and hard gamma-ray bursts (GRBs). If this is true, one may expect that the short and hard GRBs, at least some of GRBs in this class, are distributed in the Euclidean space and that the angular position of these GRBs is correlated with galaxy clusters. Even though it is reported that the correlation is statistically marginal, the observed value of < $V/V_{max}$ > deviates from the Euclidean value. The latter fact is often used as evidence against a local extragalactic origin for short GRB class. We demonstrate that GRB sample of which the value of < $V/V_{max}$ > deviates from the Euclidean value can be spatially confined within the low value of z. We select very short bursts (TgO < 0.3 sec) from the BATSE 4B catalog. The value of < $V/V_{max}$ > of the short bursts is 0.4459. Considering a conic-beam and a cylindrical beam for the luminosity function, we deduce the corresponding spatial distribution of the GRB sources. We also calculate the fraction of bursts whose redshifts are larger than a certain redshift z', i.e. f>z'. We find that GRBs may be distributed near to us, despite the non-Euclidean value of < $V/V_{max}$ >. A broad and uniform beam pattern seems compatible with the magnetar model in that the magnetar model requires a small $z_{max}$.

정보통신산업(ICT)의 글로벌 가치사슬구조분석 (Global Value Chain Structure Analysis for ICT Industry)

  • 조상섭;채동우;이중만
    • Journal of Information Technology Applications and Management
    • /
    • 제26권6호
    • /
    • pp.65-78
    • /
    • 2019
  • This study describes the accounting approach of separating the value chain components that occur between the origin and destination of a country's total exports, and applied this analysis to the nation's information and communication industry. As a result of this study, the analysis results of ICT's global value chain for the United States and China, focusing on Korea, are as follows: First of all, the value added standard was relatively lower than the export amount standard for the information and communication industry. In particular, the gap was starkly visible in the information and communication manufacturing sector, where global vertical specialization was developed relatively. As a representative sector, the computer-related equipment sector exported to China became more specialized vertically than other information and communication industries. Next, the method of participating in vertical specialization of Korea's information and communication sector and its relative position in the global value chain came from domestic products (0.25/35.16) whose total exports, which were double calculated in the case of the U.S. market, returned home. On the other hand, about 32.68 percent returned to the Chinese market. Finally, in the global value chain level, the SW sector occupied a medium vertical culture location for the information and communication equipment sector and the information and communication service sector.

도시 저임금 취업주부의 가정관리에 대한 가치의식과 가정관리 행동에 관한 연구 (A Study on the relation of Urban Low-Paid housewives Value Consciousness and Activities of Home Management.)

  • 박미금;장명욱
    • 가정과삶의질연구
    • /
    • 제3권1호
    • /
    • pp.1-13
    • /
    • 1985
  • The Purpose of this study is to investigate both the value consciousness of home management and home management activities which urban low-paid housewives have and to find out the value consciousness of home management has an influence upon the home management activities. The results obtained area as follows; 1) Most of urban low-paid housewives are place in a traditional position of home management as a housekeeper or as a family leader. 2)But partially they gave more or less modern standpoints in consuming, planning and family relationship. 3) The value consciousness of home management of urban low-paid housewives is variable according to housewives' age (P<.05), education (P<.001), numbers of children(P<0.5) and wording experiences before marriage (P<0.1). The younger respondonts showed rather modernistic value consciousness of home management. The respondonts who have high educational level showed the same result. It is also strong points form them to habe few children and to have working experiences before marriage. 4) while the home management activities of urban low-paid housewives are positive as for connecting with human relationship, consuming and evaluating they are negative as for connecting with planning, creativity and housekeeping. 5)On the whole, the home management activities are variable by housewives' age (P<.05). The younger showed more effective home management abilities. 6) the home management activities of urban low-paid housewives are influenced by the value consciousness of home management. The more modernistic value consciousness of home management is connected directed directly with excellent home management activities.

  • PDF

흉부 촬영시 심음영 확대에 따른 유용성에 관한 연구 (The Usefulness of Magnification of the Heart Shadow in Chest Radiography)

  • 박은경;이건영;정용태;동경래;지연상
    • 대한디지털의료영상학회논문지
    • /
    • 제12권2호
    • /
    • pp.119-125
    • /
    • 2010
  • In order to demonstrate the value of long-distance radiography, we have studied how distance affects images in chest frontal radiography and compared short-distance and long-distance images in chest lateral radiography. Cardiothoracic ratio(CTR %) of 50 patients with no disease in the chest(10 each at the age of 20~60) were evaluated in Supine AP(100 cm), Sitting AP(100 cm), Sitting AP(180 cm), and Erect PA(180 cm). In lateral radiography, we evaluated and compared left lateral radiography(100 cm and 180 cm) of the patients based on the horizontal maximum of the heart. The average value of CTR(%) were 0.48 in Erect PA(180 cm), 0.52 in Supine AP(100 cm), 0.50 in Sitting AP(100 cm), 0.49 in Sitting AP(180 cm), which were Supine AP(100 cm) > Sitting AP(100 cm) > Sitting AP(180 cm) > Erect PA(180 cm). The average value of Maximum transverse diameter of left of the cardiac(MLD), which showed how much axis of spine was slanted to the left, was 90.67 mm in Erect PA(180 cm), 103.92 mm in Supine AP(100 cm), 93.54 mm in Sitting(100 cm), 89.84 mm in Sitting AP(180 cm), 58.11 mm in the minimum value and 118.79 mm in the maximum value. The average value of Maximum transverse diameter of right side of the cardiac(MRD), which suggested how much axis of spine was slanted to the right, was 47.18 mm in Erect PA(180 cm), 48.12 mm in Supine AP(100 cm), 44.98 mm in Sitting AP(180 cm), and the minimum value 26.84 mm and the maximum value 65.30 mm. There was no standard method to calculate; therefore, the horizontal maximum of the heart was used for lateral radiography. The average value was 121.07 mm in 100 cm and 109.76 mm in 180 cm. Sitting AP(180 cm) among the types was closest to C-PA(180 cm). As a result, during C-AP radiography, long-distance radiography lessened shadow of the heart more than that of short distance, Sitting position more than Supine position.

  • PDF

온톨로지 기반의 실내 LBS를 위한 위치 추적 시스템 (Ontology-based Positioning Systems for Indoor LBS)

  • 황치곤;윤창표
    • 한국정보통신학회논문지
    • /
    • 제20권6호
    • /
    • pp.1123-1128
    • /
    • 2016
  • 최근 IoT 기술에서 BLE Beacon은 실내 측위를 위한 방법으로 많이 이용되고 있다. 그러나 정확한 측위를 위하여 필터링 기술은 필요하다. 그것은 대부분 고정형 비콘을 이용되었다. 정확한 위치 산출은 비콘을 통해 발생된 정보를 수신하여 측정하는 것은 정확성이 떨어지기 때문에 필터링이 중요하다. 그래서 위치를 산출하고, 불필요한 값을 필터링하는데 많은 시간이 소요된다. 이에 본 논문은 실내에 고정된 비콘이 아니라 이동하는 비콘의 정확한 위치 측정하고, 이를 재사용하는 방안으로 온톨로지를 이용하는 방법을 제안한다. 수신세기(RSSI)는 비콘과의 거리를 나타내는 대표적인 값이다. 이 값은 값들 간의 연관관계 분석을 통한 정규화로써 위치 온톨로지를 구성한다. 이 온톨로지는 이동하는 비콘의 위치 정보를 산출하는 방법이 된다. 사용자를 식별하기 위한 식별 온톨로지와 식별된 사용자를 위한 서비스를 제공하기 위한 서비스 온톨로지를 제공한다. 이는 실내에서 빠르고 정확한 위치 정보 및 서비스를 제공할 수 있다.

Effects of Position of Auxiliary Probe on Ground Resistance Measurement Using Fall-of-Potential Method

  • Gil, Hyoung-Jun;Kim, Dong-Woo;Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon
    • International Journal of Safety
    • /
    • 제7권2호
    • /
    • pp.1-6
    • /
    • 2008
  • In this paper, the effects of the position and the angle of the potential probes on the measurements of the ground resistance using the fall-of-potential method are described and the testing techniques for minimizing the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position and angle of auxiliary probes. In order to analyze the relative error in the measured value of the ground resistance due to the position of the potential probe, the ground resistance was measured for the case in which the distance of the current probe was fixed at 50[m] and the distance of the potential probe was located from 10[m] to 50[m]. Also, the potential probe was located in turn at $30[^{\circ}]$, $45[^{\circ}]$, $60[^{\circ}]$, $90[^{\circ}]$, and $180[^{\circ}]$. As a consequence, relative error decreased with increasing distance of the potential probe and decreasing angle between the current probe and potential probe. The results could help to determine the position of the potential probe during the ground resistance measurement.