• Title/Summary/Keyword: unreacted model

Search Result 34, Processing Time 0.032 seconds

A Study on the Model of Sulfidation Kinetics Using Seashell Wastes (패각 폐기물을 이용한 황화반응 모델에 관한 연구)

  • Kim Young-Sik
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.5 s.81
    • /
    • pp.395-401
    • /
    • 2004
  • In this study, lots of methods have been studing to utilize energy and decrease contaminated effluents. There has been great progress on IGCC (Integrated gasification combined cycle) to reduce thermal energy losses. The following results have been conducted from desulfurization experiments using waste shell to remove $H_{2}S$. Unreacted core model ior desulfuriration rate prediction of sorbent was indicated. These were linear relationship between time and conversion. So co-current diffusion resistance was conducted reaction rate controlling step. The sulfidation rate is likely to be controlled primarily by countercurrent diffusion through the product layer of calcium sulfide(CaS) formed. Maximum desulfurization capacity was observed at 0.631 mm for lime, oyster and hard-shelled mussel. The kinetics of the sorption of $H_{2}S$ by CaO is sensitive to the reaction temperature and particle size at $800^{\circ}C$, and the reaction rate of oyster was faster than the calcined limestone at $700^{\circ}C$.

Numerical and experimental study for Datong coal gasification in entrained flow coal gasifier

  • Park, Y. C.;Park, T. J.;Kim, J. H.;Lee, J. G.
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2001.11a
    • /
    • pp.69-76
    • /
    • 2001
  • The coal gasification process of a slurry feed type, entrained-flow coal gasifier was numerically predicted in this paper. By divding the complicated coal gasification process into several simplified stages suh as slurry evaporation, coal devolitilisation and two-phase reactions coupled with turbulent flow and two-phase heat transfer, a comprehensive numerical model was constructed to simulate the coal gasification process. The k-$\varepsilon$turbulence model was used for the gas phase flow while the Random-trajectory model was applied to describe the behavior of the coal slurry particles. The unreacted-core shrinking model and modified Eddy Break-Up(EBU) model were used to simulate the heterogeneous and homogeneous reactions, respectively. The simulation results obtained the detailed informations about the flow field, temperature inside the gasifier. Meanwhile, the simulation results were compared with the experimental data as function of $O_2$/coal ratio. It illustrated that the calculated carbon conversions agreed with the measured ones and that the measurd quality of the atngas was better than the calculated one when the $O_2$/coal ratio increases. The result was related with the total heat loss through the gasifier and uncertain kinetics for the heterogeneous reactions.

  • PDF

Study on the Reduction Kinetics of In2O3 with Hydrogen (수소에 의한 In2O3의 환원반응속도론 연구)

  • Nahm, Kee-Suk;Kim, Youn-Sop;Lee, Wha-Young
    • Applied Chemistry for Engineering
    • /
    • v.3 no.2
    • /
    • pp.305-311
    • /
    • 1992
  • The experimental study on the reduction of $In_2O_3$ was performed by using thermogravimetric analyzer. The reduction of $In_2O_3$ was occurred at above $300^{\circ}C$. The reduction rates were rapidly increased with the reaction temperature, whilehardly affectedby the flow rate of hydrogen gas. It was found that the unreacted core model could be applied for the analysis of the reduction data and the rate control step was the chemical reaction of $In_2O_3$ with hydrogen on the surface of unreacted $In_2O_3$. The apparent activation energy for this reaction was 20kcal/g-mol $H_2$ and the rate equation of $In_2O_3$ reduction with hydrogen could be expressed in the following equation. ${\frac{dX}{dt}}=1.6{\times}10^5e^{-20000/RT}(1-X)^{2/3}$

  • PDF

Characterization and Formation of Chemical Bonds of Silica-Coupling Agent-Rubber (실리카-커플링제-고무의 화학 결합 형성과 특성 분석)

  • Ko, Eunah;Choi, Sung-Seen
    • Elastomers and Composites
    • /
    • v.49 no.3
    • /
    • pp.239-244
    • /
    • 2014
  • Reaction between silica and silane coupling agent without solvent was investigated using transmission mode Fourier transform infrared spectroscopy (FTIR) and thermogravimetric analysis (TGA). Bis[3-(triethoxysilylpropyl) tetrasulfide] (TESPT) was used as a silane coupling agent. After removing the unreacted TESPT, formation of chemical bonds was analyzed using FTIR and content of reacted TESPT was determined using TGA. Content of the coupling agent bonded to silica increased with increase in the coupling agent content, but the oligomers were formed by condensation reaction between coupling agents when the coupling agent was used to excess. In order to identify bonds formed among silica, coupling agent, and rubber, a silica-coupling agent-BR model composite was prepared by reaction of the modified silica with liquid BR of low molecular weight and chemical bond formation of silica-coupling agent-BR was investigated. Unreacted rubber was removed with solvent and analysis was performed using FTIR and TGA. BR was reacted with the coupling agent of the modified silica to form chemical bonds. Polarity of silica surface was strikingly reduced and particle size of silica was increased by chemical bond formation of silica-coupling agent-BR.

A Study for Rocket Exhaust Flow Cooling due to the Central Spray Type Water Injection (중앙 분사 방식 냉각수 투입에 의한 로켓 연소 후류 냉각에 관한 연구)

  • Kang, Sun-Il;Nam, Jung-Won;Huh, Hwan-Il
    • Aerospace Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.163-172
    • /
    • 2013
  • In this study, the cooling of rocket exhaust plume by sprayed water inside plume were investigated as varying of sprayed water mass, location, and method using computational fluid analysis. For Analyze rocket exhaust plume, a single species unreacted analysis model based on the chemically frozen analysis was used and the discrete particle model which was a kind of Euler-Lagrangian analysis model was used for simulate sprayed water inside plume. It was confirmed that the temperature of plume was reduced without cooling when water mass was two times of plume mass through analysis results.

Thermal cracking analysis of concrete with cement hydration model and equivalent age method

  • Tian, Ye;Jin, Xianyu;Jin, Nanguo
    • Computers and Concrete
    • /
    • v.11 no.4
    • /
    • pp.271-289
    • /
    • 2013
  • In this research, a developed microstructural model of cement particles was presented to describe the cement hydration procedure. To simplify the hydration process, the whole hydration was analyzed in a series of sub-steps. In each step, the hydration degree, as well as the microstructural size of the hydration cell, was calculated as a function of the radius of the unreacted cement particles. With the consideration of the water consumption and the reduction of the interfacial area between water and hydration products, the micro-level expressions of the cement hydration kinetics were established. Then the heat released and temperature history of the concrete was carried out with the hydration degree obtained from each sub-steps. The equivalent age method based on the Arrhenius law was introduced in this research. Based on the equivalent age method, a maturity model was applied to describe the evolution of the mechanical properties of the material during the hydration process. The finite element program ANSYS was used to analyze the temperature field in concrete structures. Then thermal stress field was calculated using the elasticity modulus obtained from code formulate. And the risk of thermal cracking was estimated by the comparison of thermal stress and concrete tensile strength.

Effects of Reactor Type on the Economy of the Ethanol Dehydration Process: Multitubular vs. Adiabatic Reactors

  • Yoo, Kee-Youn
    • Korean Chemical Engineering Research
    • /
    • v.59 no.3
    • /
    • pp.467-479
    • /
    • 2021
  • Abstract: A kinetic model was developed for the dehydration of ethanol to ethylene based on two parallel reaction pathways. Kinetic parameters were estimated by fitting experimental data of powder catalysts in a lab-scale test, and the effectiveness factor was determined using data from pellet-type catalysts in bench-scale experiments. The developed model was used to design a multitubular fixed-bed reactor (MTR) and an adiabatic reactor (AR) at a 10 ton per day scale. The two different reactor types resulted in different process configurations: the MTR consumed the ethanol completely and did not produce the reaction intermediate, diethyl ether (DEE), resulting in simple separation trains at the expense of high equipment cost for the reactor, whereas the AR required azeotropic distillation and cryogenic distillation to recycle the unreacted ethanol and to separate the undesired DEE, respectively. Quantitative analysis based on the equipment and annual energy costs showed that, despite high equipment cost of the reactor, the MTR process had the advantages of high productivity and simple separation trains, whereas the use of additional separation trains in the AR process increased both the total equipment cost and the annual energy cost per unit production rate.

Removal and Regeneration of $SO_2$ by Cupric Oxide Supported on Zeolite (CuO/Zeolite에 의한 $SO_2$의 제거 및 재생)

  • 이승재;신창섭;이태희
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.6 no.2
    • /
    • pp.161-167
    • /
    • 1990
  • The reaction of sulfur dioxide with cupric oxide supported on zeolite was investigated over a temperature range of $250{\sim}450^{{\circ}C$. After the completion of the $SO_2$ removal reaction, the cupric sulfate produced was regenerated to copper by hydrogen or LPG. The experimental results showed that the removal efficiency of $SO_2$ was improved with temperature increase and with $SO_2$ inlet concentration decrease. The reaction of $SO_2$ with CuO/Zeolite was well explained by the shrinking unreacted core model using first order chemical reaction control and diffusion control. THe reaction rate constant and the effective diffusivity were respectively as follows: 1k (cm/s) = 2.519 exp[-10991 (cal/mol)/RT] $De(cm^2/s) = 2.06 \times 10^{-5} exp[-8380 (cal/mol)/RT]$

  • PDF

Removal of Sulfur Dioxide by Cupric Oxide and Reduction of Cupric Sulfate by Hydrogen (산화구리에 의한 이산화황의 제거와 수소에 의한 황산구리의 환원)

  • 노용우;이명철;이재훈;이태희
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.2
    • /
    • pp.83-89
    • /
    • 1994
  • The reaction of sulfur dioxide with cupric oxide was investigated over a temperature range of 300-50$0^{\circ}C$, and the regenaration reaction was studied using cupric sulfate and hydrogen over a temperature range of 240-35$0^{\circ}C$ in a fixed bed reactor. The experimental results showed that the efficiencies for elimination and regenaration reactions were maximum at 45$0^{\circ}C$ and at 30$0^{\circ}C$ respectively. In both cases the experimental data could be interpreted properly by shrinking unreacted core model while the chemical reaction is rate controlling step. The reaction rate constants were determined to be 24.88 exp(-6724/RT) (cm/min) for elimination reaction, and 0.0165 exp(-2047/RT)(cm/min ) for regeneration reaction.

  • PDF

Evaluation of Self-Healing Performance Using Hydration Model of Portland Cement and Clinker (포틀랜드시멘트와 클링커의 수화모델을 이용한 자기치유 성능평가)

  • Choi, Sang-Hyeon;Park, Byoung-Sun;Cha, Soo-Won
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.1
    • /
    • pp.81-87
    • /
    • 2020
  • Crack control is essential to increase the durability of concrete significantly. Healing of crack can be controlled by rehydration of unreacted clinkers at the crack surface. In this paper, by comparing the results of isothermal calorimetry test and regression analysis, the Parrot & Killoh's cement hydration model was verified and clink er hydration model was proposed. The composition and quantification of hydration products were simulated by combining kinematic hydration model and thermodynamic model. Hydration simulation was conducted using the verified and proposed hydration model, and the simulation was performed by the substitution rate of clink er. The type and quantity of the final hydration product and healing product were predicted and, in addition, the optimal cementitious material of self-healing concrete was selected using the proposed hydration model.