• Title/Summary/Keyword: unified design

Search Result 829, Processing Time 0.027 seconds

New Unified PID Position Control Algorithm for High Performance Position Control Loop Using Linear Machine Drive (선형 전동기의 고성능 위치 제어를 위한 새로운 통합 PID 제어기에 관한 연구)

  • Lee, You-In;Kim, Joohn-Sheok;Kim, Yong-Yil
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.389-391
    • /
    • 1999
  • Recently, the application of the linear machine for industrial field is remarkable increased, especially for the gantry machine. machine tool system and CNC. In these application fields. high precise position control performance is essentially required in both the steady and transient state. And linear machine is necessary for high-precision processing and manipulation when relatively high forces are involved. This paper presents the new unified PID position control algorithm which have rare sensitivity to disturbance, which the gain adjusting process is simple. Also this paper investigates the use of the New Unified PID control to design for high stiffness. Through the experimental results, it is shown that the proposed algorithm has high dynamic characteristic for the linear machine application field nevertheless of its simple structure.

  • PDF

Unified Power Quality Conditioner for Compensating Voltage Interruption

  • Han, Byung-Moon;Cho, Bo-Hyung;Sul, Seung-Ki;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.4
    • /
    • pp.503-512
    • /
    • 2006
  • This paper proposes a new configuration for the Unified Power Quality Conditioner, which has a DC/DC converter with super-capacitors for energy storage. The proposed UPQC can compensate the reactive power, harmonic current, voltage sag and swell, voltage imbalance, and voltage interruption. The performance of the proposed system was analyzed through simulations with PSCAD/EMTDC software. The feasibility of system implementation is confirmed through experimental works with a prototype. The proposed UPQC has ultimate capability to improve the power quality at the point of installation on power distribution systems and industrial power systems.

Design of Unified HEVC 4×4 IDCT/IDST Block (HEVC 4×4 IDCT/IDST 통합 블록 설계)

  • Jung, Seulkee;Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.19 no.2
    • /
    • pp.271-275
    • /
    • 2015
  • This paper proposes a unified HEVC $4{\times}4$ IDCT/IDST architecture for area reduction. In general, $4{\times}4$ IDCT and $4{\times}4$ IDST blocks are implemented separately, and they are connected with multiplexers. In the proposed arechitecture, these two blocks are unified, and internal hardware resources such as multipliers are shared. This reduces the chip area. The synthesized block in 0.18 um technology is 2,795 gates, and the gate count is reduced by 9.44% in comparison with conventional designs.

Experimental Operation Analysis of Unified Power Flow Controller with Cascaded H-Bridge Modules (다계 H-브리지 모듈로 구성된 UPFC(Unified Power flow Compensator)의 실험적 동작분석)

  • Baek Seung-Tak;Han Byung-Moon;Choo Jin-Boo;Chang Byung-Hoon;Yoon Jong-Su
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.9
    • /
    • pp.422-430
    • /
    • 2005
  • This paper describes experimental analysis of UPFC, which is composed of cascaded H-bridge modules and single-phase multi-winding transformers for isolation. The operational characteristic was analyzed through experimental works with a scaled model, and simulation results with PSCAD/EMTDC. The UPFC proposed in this paper can be directly connected to the transmission line without series injection transformers. It has flexibility to expand the operation voltage by increasing the number of H-bridge modules. The analysis results can be utilized to design the actual WFC system applicable for the transmission system.

Performance Analysis of UPFC by Simulation & Scaled Hardware Model (시뮬레이션과 축소모형에 의한 UPFC의 성능해석)

  • Park, Ji-Yong;Baek, Seung-Taek;Kim, Hui-Jong;Han, Byeong-Mun;Han, Hak-Geun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.10
    • /
    • pp.579-586
    • /
    • 1999
  • This paper describes a simulation model and a scaled hardware model to analyze the dynamic performance of Unified Power Flow Controller, which can flexibly adjust the active power flow through the ac transmission line. The design of control system for UPFC was developed using vector control method. The results of simulation and scaled hardware test show that the developed control system works accurately. Both models would be very effective for analyzing the dynamic performance of the Unified Power Flow Controller.

  • PDF

Dynamic Performance Analysis of Unified Power Quality Conditioner with Cascaded H-Bridges (다중브리지로 구성된 UPQC(Unified Power Quality Conditioner)의 동적 성능분석)

  • Han, Byung-Moon;Soh, Yong-Cheol;Kim, Hyun-Woo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.2
    • /
    • pp.94-102
    • /
    • 2006
  • This paper describes experimental analysis of UPQC, which is composed of cascaded H-bridges and single-phase multi-winding transformers. The operational characteristic was analyzed through experimental works with a scaled model, and simulations with PSCAD/EMTDC. The UPQC proposed in this paper can be directly connected to the distribution line without series injection transformers. It has flexibility to expand the operation voltage by increasing the number of H-bridge modules. The analysis results can be utilized to design the actual UPQC system applicable for the actual distribution system.

Design and Implementation of Unified Network Security System support for Traffic Management (종단간 트래픽 관리를 지원하는 통합 네트워크 보안시스템 설계 및 구현)

  • Hwang, Ho-Young;Kim, Seung-Cheon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.6
    • /
    • pp.267-273
    • /
    • 2011
  • The importance of networking capability is gaining more weight for enterprise business and high-speed Internet access with guaranteed security management is essential to companies. This paper presents a unified network security management solution to support high-speed Internet access, active security management, traffic classification and control. The presented system provides firewall, VPN, intrusion detection, contents filtering, traffic management, QoS management, and history log functions in unified manner implemented in a single appliance device located at the edge of enterprise networks. This will enable cost effective unified network security solution to companies.

An implementation of a unified ALU in multi-core GPGPU based on SIMT architecture (SIMT 구조 기반 멀티코어 GPGPU의 통합 ALU 설계)

  • Kyung, Gyu-taek;Kwak, Jae-Chang;Lee, Kwang-yeob
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.540-543
    • /
    • 2013
  • This paper describes an implementation of a unified ALU on multi-core GPGPU based on SIMT architecture. Our unified ALU can operate conditional branch instructions, data movement instructions, integer arithmetic instructions and floating-point arithmetic instructions. Since multi-core GPGPU contains a lot of ALU for parallel processing of various types, the main point of this paper is to design the minimum size ALU by unifying similar processing of each operations on circit level. All instrunctions were tested by making a test program. And we compare this results with results of CPU operations to verify our ALU. Our unified ALU's gate size is approximately 20,000 and the maximum operation frequency is 430MHz.

  • PDF

Design and Implementation of an Unified Cursor Considering Synchronization on the Android Mobile Platform (안드로이드 플랫폼 상에서 동기화가 고려된 통합 커서의 설계 및 구현)

  • Kim, Kyung-Hwan;Ha, Jo-Ho;Won, Jong-Pil;Lee, Uee-Song;Kim, Joo-Min;Son, Jin-Ho
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.6 no.3
    • /
    • pp.190-200
    • /
    • 2011
  • Android platform provides a content provider and a cursor mechanism to access the internal SQLite engine. Content providers not only store and retrieve data but also make it accessible to applications. Applications can only share data through content provider, since there's no common storage area that Android packages can access. Cursor is an interface that provides random read-write access to the result set returned by a database query. However, this cursor possesses two major limitations. First, a cursor does not support a join clause among cursors, since the cursor can only access a single table in the content provider. Second, the cursor is not capable of creating user-customized field in the predefined content providers. In this paper, we propose the unified cursor architecture that merges several cursors into a single virtual cursor. Cursor translation look-aside buffer (TLB), column windowing mechanism and virtual data management are the three major techniques we have adopted to implement our structure. And we also propose a delayed synchronization method between an application and a proposed unified cursor. An application can create a user-customized field and sort multiple tables using a unified cursor on Android platform.

A Unified Model Combining Technology Readiness Acceptance Model and Technology Paradox Theory (기술준비도 및 수용모델과 기술패러독스 이론에 기한 소비자 만족 모델의 통합모델에 대한 연구)

  • Kim, Choon-San;Park, Sang-Bum
    • The Journal of Industrial Distribution & Business
    • /
    • v.8 no.7
    • /
    • pp.39-49
    • /
    • 2017
  • Purpose - There are common factors both in Technology Readiness and Acceptance Model and Technology Paradox Theory which can be put together and made in one unified model. The unified model can provide the following merits. First, the unified model is simple but contains factors of the models. Second, the unified model can clarify the process of technology acceptance of common consumers. Third, the unified model can provide the opportunities to analyze the negative sides of new technology, thus find ways to improve the level of acceptance by general consumers. Research design, data, and methodology - The 450 questionnaires were handed out to people around Seoul and 421 were collected. Except insincere and wrong-marked ones, 402 were used to analyze. SPSS program was used to analyze. Factor analysis, regression analysis was conducted to test the hypotheses. Results - By analyzing sub-factors of both models and binding the common factors in one category, we accomplish one model. And we tested the model by empirical method. The results show that the results from the unified model are almost same as the results from the two models. In other words, the unified model works. Conclusions - Explaining one state of affair by two different method is in some sense distracting attention. By devising a new model including factors of both models, we can explain the affair more straightforward and efficiently. At first the technology acceptance model was devised to explain the technology users in an organization and the following tests and revised models were for the similar purposes. However, as on-lone activities including contracts have been expanded and become important, consumers as the technology uses have emerged as first factor to consider. In accordance models to explain this situation has been suggested. The model suggested in this research is one of the models but it has the following merits. That is, it is simple but has strong explanation power, it can clarify the process of technology acceptance of common consumers by containing negative sides of consumer conception, and thus, it can provide the opportunities to analyze the negative sides of new technology, also find ways to improve the level of acceptance by general consumers.