• Title/Summary/Keyword: underground development

Search Result 1,089, Processing Time 0.036 seconds

A Study on the development of optical fiber incorporated high-voltage underground power cable (광복합 고압지중전력케이블의 개발에 관한 연구)

  • Ryu, Jae-Kyu;Yoo, Sung-Jong;Jeon, Seung-Ik;Choi, Bong-Nam;Lee, Young-Ik
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1828-1830
    • /
    • 1996
  • In this study, We developed the optical fiber incorporated high-voltage underground power cable which is combined optical fibers with conventional high-voltage underground power cable. Optical-Unit that optical fiber is inserted in stainless tube is tested, and we got good results enough to safe optical fibers. Also we put the optical fiber incorporated high-voltage underground power cable to the test of electrical characteristics and optical characteristics, we knew that the electrical characteristics were the same characteristics as conventional high-voltage underground power cable and the transmission loss change was almost zero.

  • PDF

Development of a Robot System for Monitoring and Repairing a Underground Pipe (지하매설 배관의 탐사 및 도장을 위한 로봇시스템 개발)

  • Yeo, Hee-Joo;Sung, Mun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.346-348
    • /
    • 2007
  • Underground pipe is an instrument to transport rapidly and safely a lot of fluid like gas, oil, water supply and drain system. It acts like blood vessels of human body in a modern industry. As in this country, the pipe facilities have been constructing since 1970's. The pipes constructed for a long time ago are already starting to reveal the problem like corrosion and most of them are built underground. So for companies, the managing of the underground pipes is very hard because it needs high technology and a lot of money. So we made a new robot system to repair and maintain the pipes at a low price. This new robot is devised using pressing wall type to work inside 700${\sim}$900(mm) size pipe. And it has good carrying and working power.

  • PDF

Development of Waterproofing Method to Improve the Leakage Resistance and Maintenance of Underground Structures (구조물 누수 저항 및 유지관리 향상을 위한 방수공법 개발)

  • Kim, Eun-seok;Park, Hyun-Jung;Lee, Dong-Oun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.50-51
    • /
    • 2020
  • Recently, various maintenance materials and construction methods have been developed to secure the sustainable performance of structures. However, waterproofing of underground structures where groundwater infiltration is present is very difficult. In particular, the location of underground structures such as subways is very deep, and it is difficult to apply waterproof materials and construction methods in the case of structures accompanied by vibration. Therefore, we intend to study materials and methods for waterproofing leakage resistance in special environments such as underground structures.

  • PDF

Development of finite element analysis model for multi-step excavation problem (시공단계를 고려할 수 있는 유한요소 해석 모델 개발)

  • Lee, Youn-Kyou
    • Tunnel and Underground Space
    • /
    • v.6 no.4
    • /
    • pp.326-334
    • /
    • 1996
  • In underground construction the multi-step excavation sequence is commonly adopted for the convenience of the underground work. A numerical simulation method which is capable of analyzing the effects of excavation sequence on the stability of the opening is greatly needed. In this study a two dimensional finite element code was developed based on the effective numerical algorithm for the multistep excavation. The practical applicability of the model was verified for the simplified excavation sequences.

  • PDF

The fire Prevention measures of the underground transmission line (지중송전케이블의 방화대책)

  • Kwak, Bang-Myung;Tack, Eui-Gyun;Kim, Jae-Seung
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.501-503
    • /
    • 2001
  • Electric power consumption is highly increasing as the social trend requiring comfortable life, the population in a big city and the industrial development. Therefore it has become to be very important to supply the stable high-quality power. As these trend, the underground power transmission facility is highly increasing in the center of a city. As the proportion to increase facility in tunnel, the fire prevention measures of the underground transmission line become very important.

  • PDF

A Study on Development of 3D Data Model for Underground Facilities Using CityGML ADE (CityGML ADE를 이용한 3차원 지하시설물 데이터 모델 개발에 관한 연구)

  • Jeong, Da Woon;Shin, Dong Bin
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.4
    • /
    • pp.245-252
    • /
    • 2021
  • Underground facilities were constructed as needed by various management organizations, the result of which was the disordered and scattered underground spaces. This phenomenon can be viewed as the main cause of safety accidents in the underground space. To solve this problem, research on systematic construction and management of underground facilities should be conducted. Therefore, to improve the accuracy and the quality of information and to facilitate the systematic construction and management of underground facility information, this study aims to establish a 3D data model that conforms to international spatial information standards for pipeline underground facilities and to implement the data model to enable visualization. The result of this study can be used to improve the consistency of information not only between underground facilities, but also the correspondence between above ground and underground facilities. As such, this study has academic significance in that it presents an integrated data model that includes various objects in the ground and underground spaces and enables interoperability between diverse domain data.

A Study on Quality Level of Underground Spacial Information for Accuracy Improvement (지하공간정보 정확도 향상을 위한 품질등급제 연구)

  • Kim, Wondae;Lee, Kang Won;Kim, Tae Hoon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.3
    • /
    • pp.167-177
    • /
    • 2021
  • Facilities located in the underground space are closely related to the sanitation and safety of the city, and the underground spatial information is precisely constructed and used as important information for facility maintenance, safety, and underground space development. In this study, a method was studied to increase the field usability by increasing the reliability of underground spatial information constructed in Korea and used in the field. For this study, the current status of the construction of underground spatial information in Korea was summarized, and cases of the underground spatial information quality grading system applied in the US, UK, Canada, France, and Australia, which are advanced geospatial information countries, were investigated. In terms of field usability, a questionnaire was conducted on the systems, standards, and management methods related to underground spatial information of field experts and consumers working in related fields in Korea, and statistical analysis was conducted to analyze the relevance of the introduction. Through this study, it was concluded that it is necessary to introduce a quality grading system according to the construction method of underground spatial information, accuracy and reliability, and to improve related systems and regulations.

A Study on the Spatial Planning of Community in Urban Underground Space for Sustainable Urban Regeneration (지속가능한 도시재생을 위한 도심 지하공간의 커뮤니티 공간 계획에 관한 연구)

  • Ha, Mi-Kyoung;Kim, A-Hyun;Lee, Hyo-Chang
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.3
    • /
    • pp.205-216
    • /
    • 2013
  • Korean cities need sustainable urban regeneration based on the effective application of space and resource. Especially a sustainable urban regeneration needs the activation of community in the urban underground space as urban development center. The purpose of this study is to propose elements and factors of spatial planning of community in urban underground space for sustainable urban regeneration and to propose the characteristics of spatial planning of community in urban underground space according to strategies of sustainable urban regeneration. The research methods of this study used to conduct research include precedent study reviews and survey. The conclusions of this study are as following; The application of various factors related to spatial planning aspect of communication, supportive cultural facilities, accessibility and nature is needed for creating a sustainable urban regeneration. Especially, in urban underground space, the application of spatial planning for community activation considered strategies of sustainable urban regeneration should be necessary. And introduction of cultural facilities, multi-dimensional pedestrian network for accessibility and natural elements for activating community in urban underground space are needed for making sustainable urban regeneration.

Development of Standard Guideline for Water-leakage and Maintenance by parts of the Underground Structures in Multi-Family Housing - A Case Analysis of Water Leak Diagnosis - (공동주택 지하구조물의 부위별 표준 누수 진단 유지관리 지침 개발 - 누수 진단 사례 분석 -)

  • Kim, Soo Yeon;Lee, Jung Hun;Song, Je Young;Jang, Duk Bae;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.142-143
    • /
    • 2017
  • An analysis of the current water leak status of understand structure (underground parking lots, staircases, plumbing systems, water reservoirs, etc.) of multi-family housing in South Korea shows that water leaks are found from cracks in all areas of the underground structure caused by the degradation environment (water pressure by underground water, humidity, temperature, earth pressure, soil behaviour and vibration, etc.), which result in various problems, including mold, malodour, debonding of finishing materials, exfoliation, breakout, water leaks in electrical boxes, efflorescence, sedimentation of calcium hydroxide, decoloration, rusting, damages and pollution among others. Therefore, this study aims to analyse the current status of water leaks in underground structure and use the results as the basic data for developing a standard guideline for water leaks and maintenance by parts of the underground structure of multi-family housing.

  • PDF

A Study on the Component and Interior Design of the Underground Space - Focused on the Banwoldang Hetero Center of the 2 Subway Line in Daegu - (지하공간의 구성요소 및 실내디자인에 관한 연구 - 대구지하철2호선 반월당 메트로센타를 중심으로 -)

  • Kim Wan-Jun;Lee Sang-Ho
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.3 s.56
    • /
    • pp.163-172
    • /
    • 2006
  • The underground space of the Banwoldang in Daegu is the private enterprise historical development project that Daegu City & The forth construction company of the Samsung, Kolon, Daewoo, Hwasung promote, and take a role as the underground bridgehead that links east and west of the Daegu as the lunction of the 2 subway line. Accordingly, the underground space of the Banwoldang in Daegu have a import significance in that not only the alternative of the solution about the simple commercial formation or the limited ground but also compose the important axis of the city develoment. But, When I see the variety of problems, especially see the negative import in Daegu, the solution of the problems is the large underlying cause that revitalize the city. Consequently, in the study I would like to analyze the characteristics of the large underground space and the directivity of the interior design, to assistant for the develement plan of the more safe, comfort underground space.