• Title/Summary/Keyword: underground air

Search Result 550, Processing Time 0.025 seconds

Combined TPH and BTEX Analytic Method to Identify Domestic Petroleum Products in Contaminated Soil (오염토양 내 석유제품 판별을 위한 TPH 및 BTEX 분석)

  • Lim, Young-Kwan;Na, Yong-Gyu;Kim, Jeong-Min;Kim, Jong-Ryeol;Ha, Jong-Han
    • Tribology and Lubricants
    • /
    • v.33 no.6
    • /
    • pp.263-268
    • /
    • 2017
  • The significance of maintaining the soil environment is gradually increasing owing to soil and underground water contamination by petroleum leak accidents. However, the purification of soil is an expensive and more time-consuming process than the purification of contaminated water and air. Moreover, determining the source and people responsible for soil pollution gets often embroiled in legal conflicts, further delaying the cleanup process of the contaminate site. Generally, TPH (total petroleum hydrocarbon) pattern analysis is used to determine the petroleum species and polluter responsible for soil contamination. However, this process has limited application for petroleum products with a similar TPH pattern. In this study, we analyze the TPH pattern and specific sectional ratio (${\sim}C_{10}$, $C_{10}-C_{12}$, $C_{12}-C_{36}$, and $C_{36}{\sim}$) of various domestic petroleum products to identify the petroleum product responsible for soil contamination. Also, we perform BTEX (benzene, toluene, ethyl benzene, xylene) quantitative analysis and determine B:T:E:X ratio using GC-MS. The results show that gasoline grade 1 and 2 have a similar TPH pattern but different BTEX values and ratios. This means that BTEX analysis can be used as a new method to purify soil pollution. This complementary TPH and BTEX method proposed in this study can be used to identify the petroleum species and polluters present in the contaminated soil.

A Case Study of Combining NDC Blasting Method and Wide Space Blasting Method to Increase Blast Efficiency (NDC 및 Wide Space 혼합공법을 통한 발파효율 개선 사례연구)

  • No, Sang-Lim;Noh, Seung-Hwan;Lee, Sang-Pil;Lee, Hoon-Yeon;Lee, Tai-Ro
    • Tunnel and Underground Space
    • /
    • v.16 no.5 s.64
    • /
    • pp.387-393
    • /
    • 2006
  • This paper introduces the combination of two blasting methods applied to reduce blast-vibration and increase blast efficiency. NDC (New Deck Charge) blasting method using air deck effect with separation tube made of paper was effective to reduce blast-vibration, while blast efficiency was decreased a little in the bottom of a blasthole. Wide Space blasting method has an advantage to control the fragmentation and to increase blast efficiency over conventional blasting methods. In this study new blasting method combining NDC blasting method and Wide Space blasting method was applied to the field, it was confirmed to reduce blast-vibration and increase blast efficiency. It is expected to make useful blasting method to cover the public complaints and to shorten construction time by accumulating blasting data using new method with various conditions.

A New Method for Elasto-Plastic Analysis of Concrete Lining Installed in a Deep Circular Tunnel (심부 원형터널에 시공된 콘크리트 라이닝의 새로운 탄소성해석법)

  • Lee, Youn-Kyou;Park, Kyung-Soon;Song, Won-Kyong;Park, Chul-Whan;Choi, Byung-Hee
    • Tunnel and Underground Space
    • /
    • v.19 no.4
    • /
    • pp.355-365
    • /
    • 2009
  • This paper proposes an elasto-plastic finite difference method which is useful for the stability evaluation of concrete lining installed in a deep circular tunnel. Mohr-Coulomb criterion is assumed for the condition of yielding in both the rock mass and concrete lining. In order to take into account the installation delay of lining after the excavation, the outer boundary pressure acting on the lining was calculated with the consideration of the convergence occurred before the lining installation. The distributions of stress and displacement in the rock mass and lining were calculated based on the method proposed Lee & Pietruszczak (2008). The applicability of the proposed method was demonstrated by conducting the elasto-plastic analysis of concrete lining supporting an imaginary compressed air storage tunnel. The analysis result revealed that the exact determination of the boundary pressures acting on the concrete lining is of importance in the stability analysis of concrete lining.

System Networking for the Monitoring and Analysis of Local Climatic Information in Alpine Area (강원고랭지 농업기상 감시 및 분석시스템 구축)

  • 안재훈;윤진일;김기영
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.3 no.3
    • /
    • pp.156-162
    • /
    • 2001
  • In order to monitor local climatic information, twelve automated weather stations (AWS) were installed in alpine area by the Alpine Agricultural Experiment Station, Rural Development Administration (RDA), at the field of major crop located in around highland area, and collected data from 1993 to 2000. Hourly measurements of air and soil temperature (underground 10 cm,20 cm), relative humidity, wind speed and direction, precipitation, solar radiation and leaf wetness were automatically performed and the data could be collected through a public phone line. Datalogger was selected as CR10X (Campbell scientific, LTD, USA) out of consideration for sensers' compatibility, economics, endurance and conveniences. All AWS in alpine area were combined for net work and daily climatic data were analyzed in text and graphic file by program (Chumsungdae, LTD) on 1 km $\times$ 1 km grid tell basis. In this analysis system, important multi-functionalities, monitoring and analysis of local climatic information in alpine area was emphasized. The first objective was to obtain the output of a real time data from AWS. Secondly, daily climatic normals for each grid tell were calculated from geo-statistical relationships based on the climatic records of existing weather stations as well as their topographical informations. On 1 km $\times$ 1 km grid cell basis, real time climatic data from the automated weather stations and daily climatic normals were analyzed and graphed. In the future, if several simulation models were developed and connected with this system it would be possible to precisely forecast crop growth and yield or plant disease and pest by using climatic information in alpine area.

  • PDF

An Experimental Study on Factors Affecting the Leachability of Cs-137 in Cement Matrix and Leaching Model with Backfill (시멘트 고화체내 Cs-137의 침출능에 영향을 미치는 인자에 대한 실험적 연구와 뒷채움재를 고려한 침출 모델)

  • Park, Jong-Kil;Lee, Kun-Jai
    • Nuclear Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.374-386
    • /
    • 1991
  • Various factors affecting the teachability of Cs-137 in cement matrix have been investigated. Factors investigated include such as pressure curing, vibration curing, pressure leaching, the effect of the clay addition, ion-exchange resin(IRN-77) addition, and $CO_2$or air injection. Leaching experiments were conducted by the method recommended by IAEA. To analyze the experimental results, pore structure analysis of cement matrices was carried out by BET method. Cement matrices may not contact directly with underground water in real repository, since the surroundings of disposed drums are filled with backfill. Thus, the effect of backfill to the teachability has been investigated. The well-known diffusion theory was utilized to predict long term leach rate and cumulative fraction leached of Cs-137 or non-radioactive species.

  • PDF

Tectonic Link Between NE China, Yellow Sea and Korean Peninsula, Revealed by Interpreting CHAMP-GRACE Satellite Gravity Data and Sea-surface Measured Gravity Data (CHAMP-GRACE 인공위성 데이터와 해상 측정 중력 데이터에 나타난 황해안 지역의 남중국과 북중국판의 대륙 충돌대 위치)

  • Choi, Sung-Chan
    • Journal of the Korean Geophysical Society
    • /
    • v.8 no.2
    • /
    • pp.89-92
    • /
    • 2005
  • For the understanding the locus of the Quinling-Dabie-Sulu continental collision’s boundary and the underground structure of the sedimentray basin in the Yellow Sea, three dimensional density modelling is carrid out by using gravity dataset (Free Air Anomaly), which is measured by Tamhae 2, GIGAM in a period 2000-2002. The measured gravity anomaly in the investigations area is mainly responsed by depth distribution of the sedimentary basin. After comparing the sea-measured gravity data to CHAMP-GRACE satellite gravity data, I suggested that the high density model bodies extend mainly from the southern part of China to the middle-western part of the Korean Peninsula, which might be emplaced along the continental collision’s boundary. The total volume of very low density bodies modified by modelling might be about 20 000 km3.

  • PDF

A User's Location Localization Method using Smartphone Sensor on a Subway (지하철에서 스마트폰 센서를 이용한 사용자 위치 추적 방법)

  • Cho, Jung-Gil
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.3
    • /
    • pp.37-43
    • /
    • 2020
  • Smartphone-based localization has been widely studied in many different scenarios. But as far as we know, few work has addressed the problem of localization in underground public transportation systems, where GPS signal and wireless infrastructure are not always available. Knowing the location of a train is necessary to develop a useful service for subway passengers. And so, estimation of motion state and stop station by using sensors on a smartphone is being studied for subway passengers. This paper proposes a localization method that uses a barometer and a magnetic sensor on a smartphone. The method proposed in this paper first estimates whether the train runs or stops according to the change in air pressure and the strength of the magnetic field. The altitude value and the magnetic field value are then used to estimate the exact stop station of the train. We evaluated the proposed method using data from the Seoul's subway line 5. Compared with previous methods, the proposed method achieves higher accuracy.

Pattern Classification of Volatile Organic Compounds in Various Indoor Environment (다양한 실내환경 중 휘발성유기화합물 오염의 패턴 분류)

  • Kim, Yoon-Shin;Roh, Young-Man;Lee, Cheol-Min;Kim, Ki-Youn;Kim, Jong-Cheol;Jun, Hyung-Jin
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.1 s.94
    • /
    • pp.49-56
    • /
    • 2007
  • The purpose of this study was to survey the distribution patterns of volatile organic compounds(VOCs) and formaldehyde in the various indoor environments using cluster analysis. We investigated VOCs and formaldehyde in subway stations, underground shopping areas, medical centers, maternity recuperation centers, public childcare centers, large stores, funeral houses, and indoor parking lots from June,2005 to May,2006. Concentration of TVOCs in maternity recuperations was 2,605.7 ${\mu}g/m^3$ that was higher than the guideline and other facilities. TVOCs in public childcare centers was 1,951.6 ${\mu}g/m^3$ also it exceeded the guideline. Moreover, concentration of TVOCs in every facility exceeded the guideline of Department of Environment, Korea. In case of formaldehyde, mean concentration, 336.5 ${\mu}g/m^3$, in only public childcare centers exceeded the 120 ${\mu}g/m^3$ of the guideline. Finally, by applying cluster analysis, three pattterns of the indoor air pollutions were distinguished. In the results of analysis, concentrations of TVOCs and formaldehyde of cluster 3 were higher than cluster 1 and 2 that were 2,561.4 ${\mu}g/m^3$ and 184.9 ${\mu}g/m^3$, respectively.

A Study on the Actual Conditionis and Improvement Plan of Interior Landscape in the Subway Stations (지하철역내의 실내조경현황과 개선방안에 관한 연구)

  • 방광자;주진희;박혜경;박성은
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.26 no.3
    • /
    • pp.258-266
    • /
    • 1998
  • The purpose of this study is to investigate the actual conditions, to find problems, and to present an improvement plan of interior landscape in the subway stationis. Moreoiver, it will presume the possibilties to develop the subway and ways to utilie underground space effectively. The results are summarized as follows A light intensity was recorded 0-100 Lux as the lowest light and 500 Lux below as the highest in 61 subway stations. An average temperature of 12 $^{\circ}C$and an air humidity of 38% were recorded over a 4 month period from January to April, but includes a drastic variaton between -8.5$^{\circ}C$ and 21.5$^{\circ}C$. Soil acidity of pH 7 below and soil moisture of 1-2 wet degree were apeared in subway stations mostly. Plant forms consisted of artificial flower & flower. Plant species were recorded at a total of 54 species and appeared in the order of Araucaria heteropylla, Ophiophogon jaburan, Aspidistra elatior cv. 'Asahi' and Hedera helix. Plant height was, for the most part, below 0.5m. Plant species that was fined of conditions were Palm, Camellia japonica, Araucaria heterophylla as a high plant, dracaena fragrans, dracaena deremensis cv. Wakneckii as a middle plant, and Ophiopogon jaburan, Hedra helix, ytomium falcatum, Aspidistra elatior cv. Asahi as a low plant. It used to water materials such as small pool, small cascade, water cycles and natural materials such as natural rock, small rock, sand, bark and animal materials such as squirrels, birds, goldfish as an object for plants in the subway stations. From these actual conditions, First of all, It must make up physical environments such as light, temperature humidity, soil for plant growth, and is important to chooce suitable indoor plants and draw up systematic management in the subway environments. Also, it change plants frequently and uses variable objects for subway stationi individuatism, Moreover, indoor plants with strong environmental adaptation abities such as shade tolerance, drought tolerance and cold tolerance need to develope variable species possibly. If these improvements occur, utilization and amenity of subway stationis will increase, according to the use of interior landscape.

  • PDF

Hydraulic Analysis of Air-core Patterns with Various Discharge and Improving Inlet Part of the Underground Bypass Model (유량변화와 지하방수로 유입구모형의 개선에 따른 공기공동양상의 수리학적 분석)

  • Park, Sung Won;Kim, Hyung-Jun;Rhee, Dong Sop
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.369-369
    • /
    • 2016
  • 홍수피해 저감을 위한 지하방수로나 지하저류지 등은 홍수 방어를 위한 도심 내의 토지 확보 부담을 줄이며, 집중 호우 발생 시 내수를 초기에 신속하게 배제하여 제내지 침수 피해를 줄이는데 효율적으로 활용된다. 미국 및 일본, 홍콩과 같은 외국에서는 이미 지하방수로 및 지하저류지를 활용한 홍수피해 저감방안을 수립하여 활용하고 있으며, 최근 국내에서도 치수 계획 수립 시 지하방수로 혹은 지하저류지 시설 도입이 활발히 검토되고 있으나 적용사례가 전무하여 제반기술이 부족하고 많은 시행착오가 예상된다. 제반설계기술의 경우는 구조적인 방안이 모색되어야 하며 대표적으로, 지하방수로 유입구 형상이, 동일한 흐름조건에 대한 유량배제효율에 가장 지배적인 영향인자로 알려진 바 있으며 다양한 유입구 형상설계방안이 기존 실험적 연구 및 외국 설계지침에 제안된 바 있다. 지하방수로는 접근 수로를 통해 유입된 유량이 유입구를 지나며 가속되어 와류 흐름을 형성하며 수직 갱도로 유입되는 구조를 갖기 때문에 지하방수로의 방류 효율을 높이기 위해서는 유입구에서 흐름 특성을 파악하는 것이 중요하다. 이때 유입흐름특성이 사류일 경우 혹은 급격하게 유입 유량이 많아지는 경우 수직 갱도 내에 공기 공동이 형성되어 구조물 파손, 와류의 발생으로 인한 배제효율 감소 등의 피해를 야기할 수 있으므로 수리학적으로 규명할 필요가 있다. 따라서 본 연구에서는 지하방수로의 기존 유입구형상에 대한 장단점을 비교하고, 개선점을 적용하여 수리모형을 제작하여 개수로 실험장치에 설치하고 다양한 유입흐름조건에 따라 수리실험을 수행하였다. 그 결과 유입흐름조건에 따라 발생하는 유입구의 공기 공동의 발달 및 소멸 그리고 규모변화를 정량적으로 분석하여, 유입부의 가능 단면적이 큰 수직갱도인 경우, 유량배제 효율이 감소되는 분석결과에 적절하게 일치하였으며, 본 연구결과는 향후 지하방수로 설계의 제반기술의 수립 시 효율적인 활용이 가능하다.

  • PDF