DOI QR코드

DOI QR Code

Pattern Classification of Volatile Organic Compounds in Various Indoor Environment

다양한 실내환경 중 휘발성유기화합물 오염의 패턴 분류

  • Kim, Yoon-Shin (Institute of Environmental & Industrial Medicine(IEIM), Hanyang University) ;
  • Roh, Young-Man (Institute of Environmental & Industrial Medicine(IEIM), Hanyang University) ;
  • Lee, Cheol-Min (Institute of Environmental & Industrial Medicine(IEIM), Hanyang University) ;
  • Kim, Ki-Youn (Institute of Environmental & Industrial Medicine(IEIM), Hanyang University) ;
  • Kim, Jong-Cheol (Institute of Environmental & Industrial Medicine(IEIM), Hanyang University) ;
  • Jun, Hyung-Jin (Institute of Environmental & Industrial Medicine(IEIM), Hanyang University)
  • 김윤신 (한양대학교 환경 및 산업의학연구소) ;
  • 노영만 (한양대학교 환경 및 산업의학연구소) ;
  • 이철민 (한양대학교 환경 및 산업의학연구소) ;
  • 김기연 (한양대학교 환경 및 산업의학연구소) ;
  • 김종철 (한양대학교 환경 및 산업의학연구소) ;
  • 전형진 (한양대학교 환경 및 산업의학연구소)
  • Published : 2007.02.28

Abstract

The purpose of this study was to survey the distribution patterns of volatile organic compounds(VOCs) and formaldehyde in the various indoor environments using cluster analysis. We investigated VOCs and formaldehyde in subway stations, underground shopping areas, medical centers, maternity recuperation centers, public childcare centers, large stores, funeral houses, and indoor parking lots from June,2005 to May,2006. Concentration of TVOCs in maternity recuperations was 2,605.7 ${\mu}g/m^3$ that was higher than the guideline and other facilities. TVOCs in public childcare centers was 1,951.6 ${\mu}g/m^3$ also it exceeded the guideline. Moreover, concentration of TVOCs in every facility exceeded the guideline of Department of Environment, Korea. In case of formaldehyde, mean concentration, 336.5 ${\mu}g/m^3$, in only public childcare centers exceeded the 120 ${\mu}g/m^3$ of the guideline. Finally, by applying cluster analysis, three pattterns of the indoor air pollutions were distinguished. In the results of analysis, concentrations of TVOCs and formaldehyde of cluster 3 were higher than cluster 1 and 2 that were 2,561.4 ${\mu}g/m^3$ and 184.9 ${\mu}g/m^3$, respectively.

Keywords

References

  1. Stolwijk, J. A. : Risk assessment of acute health and comfort effects of indoor air pollution. Annals of the New York Academy of Sciences, 641, 56-62, 1992 https://doi.org/10.1111/j.1749-6632.1992.tb16532.x
  2. National Academy of Sciences(NAS) : Human exposure assessment for airborne pollutants, Washington DC, 1993
  3. 심상효, 김윤신 : 신축공동주택의 실내공기질 특성 및 평가 -휘발성유기화합물 및 포름알데히드 중심으로-. 한국환경보건학회지, 32(4), 275-281, 2006
  4. Lee, S. C. and Chang, M. : Indoor and outdoor air quality investigation at school in Hong Kong. Chemosphere, 40, 109-112, 2000 https://doi.org/10.1016/S0045-6535(99)00260-X
  5. James E. Woods : An engineering approach to controlling indoor air quality. Environmental Health Perspectives, 95, 15-21, 1991 https://doi.org/10.2307/3431100
  6. Tichenor, B. A., Sparks, L. A., White, J. B. and Jackson, M. D. : Evaluating sources of indoor air pollution, Journal Air & Waste Manage Association, 40, 487-492, 1990 https://doi.org/10.1080/10473289.1990.10466703
  7. Dimitoroulopoulou, C., Ashmore, M. R., Byrne, M. A. and Kinnersley, R. P. : Modeling of indoor exposure to nitrogen dioxide in the UK. Atmospheric Environment, 35, 269-279, 2005 https://doi.org/10.1016/S1352-2310(00)00176-X
  8. 남보현, 황인조, 김동술 : 분산주성분 분석을 이용한 실내환경 중 PM-10 오염의 패턴분류. 한국대기환경학회지, 18(1), 25-37, 2002
  9. 황인조, 김태오, 김동술 : PMF 방법론을 이용한 수원지역 PM-10의 오염원 확인. 한국대기환경학회지, 17(2), 133-145, 2001
  10. 유상준, 김동술 : 군집분석과 분산 주성분분석법을 이용한 대기분진시료의 분류. 한국대기보전학회지, 13(1), 51-63, 1997
  11. Hopke, P. K. : Receptor Modeling in Environmental Chemistry, Wiley Interscience, New York, 1985
  12. 김동술, 김형석 : Pattern Recognition을 이용한 지하상가에서의 대기오염물의 농도 분석에 관한 연구. 한국대기보전학회지, 6(1), 1-10, 1990
  13. Hopke, P. K. : Receptor Modeling for Air Quality Management, Elsevier Science Publishing Company Inc., New York, 1991
  14. Massart, D. L. and Kaufman, L. : The Interpretation of Analytical Chemical Data by the Use of Cluster Analysis, John Wiley & Sons, New York, 1983
  15. 문경환, 변상훈, 최달웅, 이은일, 오은하, 김영환 : 실내 공기 중 일부 알데하이드류에 대한 위해도 평가. 한국환경보건학회지, 32(1), 19-26, 2006
  16. 서병량, 정만호, 전준민 : 호남지역의 다중이용시설별 실내공기질 실태 조사. 한국환경보건학회지, 32(5), 387-397, 2006

Cited by

  1. Critical Evaluation of and Suggestions for the VOCs Measurement Method Established as the Korean Indoor Air Quality Standard Method vol.30, pp.6, 2014, https://doi.org/10.5572/KOSAE.2014.30.6.586