• Title/Summary/Keyword: ultrasonic surface wave

Search Result 190, Processing Time 0.027 seconds

Ultrasonic characterization of exhumed cast iron water pipes

  • Groves, Paul;Cascante, Giovanni;Knight, Mark
    • Smart Structures and Systems
    • /
    • v.7 no.4
    • /
    • pp.241-262
    • /
    • 2011
  • Cast iron pipe has been used as a water distribution technology in North America since the early nineteenth century. The first cast iron pipes were made of grey cast iron which was succeeded by ductile iron as a pipe material in the 1940s. These different iron alloys have significantly different microstructures which give rise to distinct mechanical properties. Insight into the non-destructive structural condition assessment of aging pipes can be advantageous in developing mitigation strategies for pipe failures. This paper examines the relationship between the small-strain and large-strain properties of exhumed cast iron water pipes. Nondestructive and destructive testing programs were performed on eight pipes varying in age from 40 to 130 years. The experimental program included microstructure evaluation and ultrasonic, tensile, and flexural testing. New applications of frequency domain analysis techniques including Fourier and wavelet transforms of ultrasonic pulse velocity measurements are presented. A low correlation between wave propagation and large-strain measurements was observed. However, the wave velocities were consistently different between ductile and grey cast iron pipes (14% to 18% difference); the ductile iron pipes showed the smaller variation in wave velocities. Thus, the variation of elastic properties for ductile iron was not enough to define a linear correlation because all the measurements were practically concentrated in single cluster of points. The cross-sectional areas of the specimens tested varied as a result of minor manufacturing defects and levels of corrosion. These variations affect the large strain testing results; but, surface defects have limited effect on wave velocities and may also contribute to the low correlations observed. Lamb waves are typically not considered in the evaluation of ultrasonic pulse velocity. However, Lamb waves were found to contribute significantly to the frequency content of the ultrasonic signals possibly resulting in the poor correlations observed. Therefore, correlations between wave velocities and large strain properties obtained using specimens manufactured in the laboratory must be used with caution in the condition assessment of aged water pipes especially for grey cast iron pipes.

Investigation of Transmission Process for Ultrasonic Wave in Wood (목재 내 초음파 전달 경로 구명)

  • Lee, Jun-Jae;Kim, Gwang-Mo;Bae, Mun-Sung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.31-37
    • /
    • 2003
  • Among the nondestructive evaluation (NDE) methods for wood defect detection, ultrasonic wave has been considered as competitive technique in terms of economics and workability. Until now, researches on application of NDE methods for wood have focused mainly on standing tree and logs. Recently, some attempts have been conducted with NDE technique, for evaluation of wooden structural members. However, wooden structural members are different from others (standing tree or log) in various aspects. Expecially when some parts or whole member are covered with other materials, they can't be evaluated appropriately on general NDE methods. For the purpose of development of proper NDE technique for the wooden structural members, the ultrasonic wave transmission process investigated on artificial defect in wood. First, various types of transmission process were assumed, and then the transmission times were predicted respectively. Predicted times were compared with the measured time of ultrasonic wave and then a suitable type of transmission process is determined. In case of the ultrasonic wave doesn't transmit directly due to defect, it is reflected once only at the opposite surface of member, and the path is accord with the line of shortest length.

Study on the ultrasonic attenuation and false indications of austenitic stainless sleet Steel weldment (스테인레스강(鋼) 용접부(熔接部)의 초음파감쇠(超音波減衰) 및 거짓신호(信號)에 관(關)한 연구(硏究))

  • Kang, Suk-Chull;Lee, Yun-Peel
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.3 no.1
    • /
    • pp.19-25
    • /
    • 1983
  • Some studies have been made on the effects of the attenuation on the result of ultrasonic examination of austenitic stainless steel weldment and also on the cause of false indications. The differences in the amplitudes and the metal paths of the ultrasonic examinations have been measured experimentally, for two kinds of waves, one passed through only the parent material and the other one through the weldment. The effect of probe angles and frequency on the examination data have been investigated using the shear wave. It has been found that the false indications were caused by back reflection from the weld metal surface due to the characteristics of ultrasonic wave propagation. It has been confirmed that the probe of $2.25\;MHz\;and\;60^{\circ}$ is the best choice in the ultrasonic examination and that the correction of amplitude for attenuations is necessary.

  • PDF

A Study on the Ultrasonic Technique for Measurement of Vibration in Journal Bearing (저어널 베어링의 진동 계측을 위한 초음파 응용 기술에 관한 연구)

  • 김노유
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.476-481
    • /
    • 1999
  • This paper describes a new technique for measurement of the displacement less than one-quarter of the wavelength of ultrasonic wave using ultrasonic pulse-echo method. The technique determines the displacement of a journal bearing from the amplitudes of the total reflected waves from the surface of journal inside the bearing. Vibration of journal bearing can be measured without using a very high frequency ultrasonic transduce over 100MHz which must be used in the conventional techniques for the precision measurement of a small displacement. The method also requires no inversion process to extract the thickness from the waveforms of the reflected waves, so that it makes possible on-line measurement of the vibration of journal bearing.

  • PDF

Experimental Study of the Ultrasonic Vibration Effects on CHF Occurring on Inclined Flat Surfaces (초음파 진동이 경사진 평판에서의 CHF에 미치는 영향에 대한 실험연구)

  • 정지환;김대훈;권영철
    • Journal of Energy Engineering
    • /
    • v.12 no.2
    • /
    • pp.139-144
    • /
    • 2003
  • Augmentation of CHF by ultrasonic vibration in water pool is experimentally investigated under pool boiling condition. The experiments are carried out using copper coated plates and distilled water. Measurements of CHF on flat plate heated surface were made with and without ultrasonic wave and with variations in inclined angle of the surface and water subcooling. Experimental apparatus consists of a bath, power supply, test section, ultrasonic generator, and data acquisition system. The measurements show that ultrasonic wave enhances CHF and its extent is dependent upon inclination angle as well as water subcooling. The rate of increase in CHF increases with an increase in water subcooling while it decreases with an increase in inclination angle. Visual observation shows that the cause of CHF augmentation is closely related with the dynamic behavior of bubble generation and departure in acoustic field.

Development of Inspection Technology for the Depth Sizing on Surface Flaw of Pump Diffuser Vane (펌프 Diffuser Vane 표면결함 깊이측정 기법 개발)

  • Park, Cher-Young;Kim, Jin-Hoi
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.4 no.2
    • /
    • pp.46-49
    • /
    • 2008
  • NDE(Nondestructive examination) detects a flaw or discontinuity in materials. Flaws detected by the pre-service or in-service examinations shall be sized for the purpose of analysis and repair. A flaw that is initiated from the surface is difficult to determine its depth by NDE. The depth of the surface flaw can be measured using an ultrasonic diffracted wave. To find the optimum standard for ultrasonic parameter(For example, frequency & size of transducer), a mock-up test and simulation were established and studied. This inspection technology may show the depth sizing possibility of the flaw down to nearly two(2) mm.

  • PDF

A Study on Screening of Surface Waves by Wave Barriers (방진구조물에 의한 표면파 산란해석)

  • Lee, Jong-Seh;Kim, Hee-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.578-581
    • /
    • 2004
  • In this paper numerical and experimental studies are conducted to examine the wave screening effectiveness of wave barriers. The numerical study is based on a finite element model of a 'sandbox' with Lysmer-Kuhlemeyer-type absorbing boundaries. Using the model, the screening effectiveness of wave barriers is studied for different barrier dimensions and distances between the source/receiver and the wave barrier. The results of the numerical modeling are compared with those of the ultrasonic experiment which is performed on an acrylic block with a drilled rectangular cut. Finally, the problem of ground transmitting vibration from a traveling train is numerically treated as a real-world application and the results are discussed in some detail.

  • PDF

The Third Critical Angle in Reflection of Elastic Waves in Fiber-reinforced Composites (섬유강화 복합재료 내 탄성파 반사현상의 제3임계각)

  • Yim, Hyun-June;Baek, Eun-Sol
    • Composites Research
    • /
    • v.20 no.1
    • /
    • pp.15-22
    • /
    • 2007
  • As a fundamental approach to studying elastic wave behaviors in fiber-reinforced composites, this paper introduces the analytical method to predict the modes, directions, and amplitudes of all reflected waves that are generated by free-surface reflection in fiber-reinforced composites. The paper also explores a new phenomenon where a reflected wave that is predicted to exist in accordance with the slowness surface may disappear. This may occur when the angle of incidence of a quasi-shear wave exceeds a newly defined critical angle, named the third critical angle. It is hoped that the analytical approach introduced in this paper will provide an easy-to-follow guideline for researchers in the relevant area such as ultrasonic nondestructive testing.

Visualization of Elastic Waves Propagating on a Solid Surface with Fatigue Cracks by Laser Ultrasonic Technology

  • Imade, Masaaki;Miyauchi, Hidekazu;Okada, Saburo;Yamamoto, Shigeyuki;Takatsubo, Jyunji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.109.4-109
    • /
    • 2001
  • We have developed a laser ultrasonic system for visualization of elastic waves propagating on a solid surface, in order to visualize ultrasonic waves propagating on opaque media. This system can produce a series of successive images as an animation of wave propagation, because of scanning an optical heterodyne probe to measure surface transient displacements. Using this visualization technique, we observed the scattering and diffraction of ultrasonic waves around various shapes of artificial defects, and examined its application to nondestructive inspection. This imaging system provides various kinds of visualization images such as propagation image, amplitude image, arrival time image and velocity image. We have been confident that this technique is available for nondestructive inspection and materials ...

  • PDF

A Study on Fluxless Solder Flip Chip Bonding Using Plasma & Ultrasonic Wave (플라즈마와 초음파를 이용한 무플럭스 솔데 플립칩 접합에 관한 연구)

  • 홍순민;강춘식;정재필
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2001.11a
    • /
    • pp.138-140
    • /
    • 2001
  • Fluxless flip chip bonding using plasma & ultrasonic wave was investigated in order to evaluate the effect of plasma & ultrasonic treatment on the bondability of the Sn-3.5wt%Ag solder bumped die to TSM-coated glass substrate. The $Ar+10%H_2plasma$ was effective in removing tin oxide on solder surface. The die shear strength of the plasma-treated Si-chip is higher than that of non-treated specimen but lower than that of specimen bonded with flux. The die shear strength with the bonding load at 25W ultrasonic power increased to 0.8N/bump for all bonding temperature but decreased above 1.0N/bump.

  • PDF