• 제목/요약/키워드: ultrasonic radiation

검색결과 136건 처리시간 0.024초

파형 변환된 레이리파를 이용한 초음파영상복원 (Ultrasonic Image Reconstruction using Mode-Converted Rayleigh Wave)

  • Suh Dong-Man
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1999년도 학술발표대회 논문집 제18권 1호
    • /
    • pp.403-408
    • /
    • 1999
  • In this paper, ultrasonic tomography by the Mode-Converted Rayleigh wave (MCRW) in the back-scattered direction is presented. When a beam with a short pulse and narrow beam width enters a reflector with smooth surface, in general, two major arrivals can be observed in the output waveform: the specular reflection and the radiation of the MCRW from the reflector surface. The time-delay between the two waves is relatively large and thus can be measured easily. This large time-delay is due to the fact that the MCRW is slower than incident wave. In our method, this large time- delay is used for ultrasonic image reconstruction. To effectively detect the MCRW, the arrayed-receiving transducers are circularly arranged around the transmitter. In addition, a deconvolution method is employed to remove specular echo signals for reconstructing the MCRW image.

  • PDF

악안면 초음파의 치주학적 활용 (Ultrasonography in periodontal diagnosis)

  • 김대엽;이종빈;방은경
    • 대한치과의사협회지
    • /
    • 제55권11호
    • /
    • pp.800-807
    • /
    • 2017
  • Ultrasonography is one of the most common diagnostic tools in medical imaging with non-invasive and non-radiation loaded characteristics. In the field of dentistry, especially for periodontology, high frequency ultrasonic device can be used for several purposes such as evaluating gingival thickness, identifying the level of alveolar bone, measuring the volume of mucosa of donor site for soft tissue graft and so on. According to recent studies, it was demonstrated that ultrasonic diagnosis had both accuracy and repeatability comparable to conventional diagnostic tools. However, improvement and development of intra-oral probe suitable for adpatation to gingiva and palatal mucosa, are considered as prerequisites for diffusion of ultrasonic diagnosis in periodontology.

  • PDF

악기 향판재의 최적공진비에 미치는 접착제의 영향 (Effect of Adhesives on the Best Acoustic Radiation Ratio of Sound board for Musical Instrument)

  • 이화형
    • 한국가구학회지
    • /
    • 제11권1호
    • /
    • pp.25-29
    • /
    • 2000
  • This study was carried out to analyze the ultrasonic properties of sound board which was glued with various adhesives and to evaluate which adhesive is the best for the acoustic radiation of the musical instrument. The results are as follows: 1. Animal glue is the best adhesive for the sound board with respect to the acoustic radiation ratio of the musical instruments. Epoxy resin and polyvinyl acetate resin are the next group, urea formaldehyde resin and Hot melt are the third group, polychloroprene(CR) resin is the lowest. 2. Epoxy resin, animal glue and Titebond(PVA) give the highest shear strength and the highest wood failure relatively Hot melt and polychloroprene(CR) resin do not meet the standard because of low wood failure.

  • PDF

전기-음향 방사컨덕턴스를 이용한 치료용 초음파 자극기의 음향출력 예측 (The Acoustic Output Estimation for Therapeutic Ultrasound Equipment using Electro-Acoustic Radiation Conductance)

  • 윤용현;조문재;김용태;이명호
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권3호
    • /
    • pp.264-269
    • /
    • 2011
  • To increase therapeutic efficiency and biological safety, it is important to precision control of acoustic output for therapeutic ultrasound equipment. In this paper, the electro-acoustic radiation conductance, one of electroacoustic characteristics of therapeutic ultrasound equipment, was measured by the radiation force balance method according to IEC 61161 standards and the acoustic output was estimated using the electro-acoustic radiation conductance. The estimation of acoustic output was conducted to continuous wave mode and pulse wave mode of duty cycle between 20% and 80%. The differences between prediction values and measurement results are within 5% of measurement uncertainty, which is a reasonably good agreement. The results show that acoustic output controlled by electro-acoustic radiation conductance was found to be an effective method.

경계요소법을 이용한 결함의 초음파 산란장 해석 (Application of a Boundary element Method to the Analysis of ultrasonic Scattering by Flaws)

  • 정현조;김진호;박문철
    • 대한기계학회논문집A
    • /
    • 제26권11호
    • /
    • pp.2457-2465
    • /
    • 2002
  • Numerical modeling of a nondestructive testing system plays an important role in many aspects of quantitative nondestructive evaluation (QNDE). The ultimate goal of a model is to predict test results for a specific flaw in a material. Thus, in ultrasonic testing, a system model should include the transducer, its radiation pattern, the beam reflection and propagation, and scattering from defects. In this paper attention is focused on the scattering model and the scattered fields by defects are observed by an elastodynamic boundary element method. Flaw types addressed are void-like and crack-like flaws. When transverse ultrasonic waves are obliquely incident on the flaw, the angular distribution of far-field scattered displacements are calculated and presented in the form of A-scan mode. The component signals obtained from each scattering problem are identified and their differences are addressed. The numerical results are also compared with those obtained by high frequency approximate solutions.

수막뇌류(髓膜腦瘤)를 수반(隨伴)한 선천성뇌수종(先天性腦水腫) 1례(例)의 초음파소견(超音波所見)에 관한 보험의학적(保險醫學的) 연구(硏究) (A Study of Ultrasonography in One Congenital Hydrocephalus Case Accompanied with Meningoencephalocele)

  • 한혜진;김강석
    • 보험의학회지
    • /
    • 제2권1호
    • /
    • pp.245-252
    • /
    • 1985
  • Ultrasonographic examination in the obstetrics not only makes easy of the diagnosis of Hydrocephalus, placenta previa, anencephalus and ectopic pregnancy, etc, but also guaranteed its excellence in the diagnosis of women gynecology disease. Especially in case that it doesn't affect radiation hazard on the embryo, its efficiency keeps increasing and it is spotlighted to many clinic doctors. Even though in general hospital we often observe congenital hydrocephalus in Med. Dept. which entirly undergoes the medical examination to the insured, we don't observe even the women delivered with child and it is very difficult to find a rare congenital hydrocephlus throughout other present insurance companies. We inspected a congenital hydrocephalus, which other medical equipments of present insurance companies have many difficulties in the medical examination, accompanied by meningoencephalocele by ultrasonic diagnosis. We analyzed and compared the data by ultrasonic diagnosis with that of surgical diagnosis and the results are follows; 1) We could correctly describe meningoencephalocele by ultrasonic diagnosis. 2) It was able to be diagnosed in LMP 22 weeks. 3) BPD has about 10 mm higher than normal value in LMP 22 weeks. 4) Dilatation of lateral ventricle was observed in LMP 22 weeks. 5) As paralled with ultrasonic diagnosis in pregnancy medical examination, accepting declines including the risk rate can be restrained.

  • PDF

초음파센서를 이용한 냉중성자원 수직공 형상측정 (Measurement of the Shape of the Cold Neutron Source Vertical Hole by Ultrasonic Wave Sensor)

  • 박국남;최창웅;심철무
    • 대한기계학회논문집A
    • /
    • 제24권9호
    • /
    • pp.2167-2173
    • /
    • 2000
  • The HANARO (High-flux Advanced Neutron Application Reactor) has operated since 1995. The Cold Neutron(CN) hole was implanted in the reflector tank from the design stage. Before a vacuum chamber and a moderator cell for the cold neutron source are installed into the CN hole, it is necessary to measure the exact size of the inside diameter and thickness of the CN hole to prevent the interference problem. Due to inaccessibility and high radiation field in the CN hole, a mechanical measurement method is not permitted. The immersion ultrasonic technique is considered as the best method to measure the thickness and the diameter. The 4 axis manipulator of the 2 channel of a sensor module was fabricated. The transducer of 10 MHz results in 0.03 nun of resolution. The inside diameter and thickness for 550 points of the CN hole were measured using 2 channel ultrasonic sensors. The results showed that the thickness is in the range of 13-6.7 mm and inside diameter is in the range of o 156-165. These data will be a good reference in the design of a cold neutron source facility.

액체금속로 소듐내부 가시화를 위한 초음파 웨이브가이드 센서 개발 (Development of Ultrasonic Waveguide Sensor for Under=Sodium Viewing in Liquid Metal Reactor)

  • 주영상;이재한
    • 비파괴검사학회지
    • /
    • 제26권1호
    • /
    • pp.18-24
    • /
    • 2006
  • 액체금속로 원자로 노심과 내부구조물 들은 불투명한 소듐 내에 잠겨 있어 육안검사를 수행할 수 없다. 액체금속로 내부구조물의 육안검사를 수행하기 위해서는 초음파를 이용한 소듐내부 가시화가 적용되어야 한다. 본 연구에서는 소듐내부 가시화에 적용하기 위한 판형 초음파 웨이브가이드 센서를 개발하였다. 웨이브가이드 센서에서의 판파 전파특성을 분석하고 판파 적용모드로 제0차 반대칭 $A_0$ 모드를 선정하였다 웨이브가이드 센서에 액체 웨지를 적용하여 $A_0$ 모드의 저주파수 분산 영역에서 판파가 발진되도록 하였으며 입사펄스의 주파수 변조에 의하여 초음파 빔 방사각을 변환시킬 수 있는 새로운 방법을 제안하였다 본 방법은 웨이브가이드 센서를 기계적으로 구동하지 않고 빔 방사각을 조정할 수 있어 기존 웨이브가이드 센서의 구동 제한성을 극복할 수 있게 해 준다. 웨이브가이드 센서의 빔 방사각 변환 특성을 실험적으로 검증하였으며, 수중 C-스캔 시험을 수행하여 웨이브가이드 센서의 소듐내부 가시화 적용 가능성을 확인하였다.

후방 복사된 초음파를 이용한 표면 지역의 평가 기술 (The Evaluation Technique of Surface Region using Backward-Radiated Ultrasound)

  • 권성덕
    • 비파괴검사학회지
    • /
    • 제16권4호
    • /
    • pp.241-250
    • /
    • 1997
  • 액체/고체 경계면에서 후방 복사된 초음파의 주파수 분석에 의해 Si layer/mesh Au/Si substrate 시편에 존재하는 표면 탄성파의 주파수 의존성이 측정되었다. 사용된 광역 탐촉자(2, 5, 10MHz)의 주파수에 따라 다르게 나타난 후방 복사의 입사각 의존성은 이 현상이 표면 지역에 발생된 표면파로부터의 에너지 복사에 의한 것임을 보여주었다. 후방 산란된 초음파의 입사각 의존성을 연속적으로 측정하기 위한 초음파 각도계가 제작되었고 다른 비율의 구리 분말이 섞인 에폭시에 의해 접착된 Ni layer/Al substrate 시편에 대해 후방복사 세기의 입사각 의존성이 측정되었다. (5MHz) 후방 복사의 폭과 패턴은 표면파 속도의 주파수 의존성, layer 접합의 질 그리고 표면 지역의 구조 등 여러 정보를 가지고 있음이 밝혀졌다.

  • PDF