• Title/Summary/Keyword: ultrasonic attenuation

검색결과 224건 처리시간 0.025초

Al/Epoxy 이종재 접합 계면의 초음파 감쇠계수에 의한 균열길이의 측정 (Measurement of Crack Length by Ultrasonic Attenuation Coefficients on Interfaces of Al/Epoxy Bonded Dissimilar Materials)

  • 박성일;정남용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1109-1114
    • /
    • 2003
  • The initial crack often occurs on the bonded interface and it is the general cause of the interface fracture. It is very significant to establish the measurement method of interfacial crack by applying the ultrasonic technology into the interface of bonded dissimilar materials. In this paper, the interfacial crack length was measured by ultrasonic attenuation coefficient in the Al/Epoxy bonded dissimilar materials of double-cantilever beam(DCB). The energy release rate, G, was obtained by the experimental and Ripling's equation measurement of compliance. The experimental results represent that the relation between interfacial crack length for the ultrasonic attenuation coefficient and energy release rate is increased proportionally. From the experimental results, a measurement method of the interfacial crack length by the ultrasonic attenuation coefficient was proposed and discussed.

  • PDF

초음파 광역 감쇠의 온도 특성에 관한 연구 (A Study on Temperature Features of Broadband Ultrasonic Attenuation)

  • 신정식;안중환;한승무;김형준
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.245-248
    • /
    • 1997
  • The distilled water is used for the ultrasonic wave propagating material in the measurements of broadband ultrasonic attenuation (BUA) that is applied in industrial and medical applications, The acoustic impedance of water is significantly changed with its temperature. Therefore, the quantitative evaluation of BUA with temperature and the ultrasonic wave propagating distance is highly needed. In this study, we evaluated the variation of attenuation with change in temperature. To measure the variation of BUA in the low frequency region at the temperatures, 27$^{\circ}C$, 29$^{\circ}C$, and 31$^{\circ}C$, we tested the Plyethylene, Teflon, MC-Nylon, Urethane specimens and analyzed the center frequency, frequency bandwidth, spectral peak amplitude. The results showed that BUA value appeared to be lower with increasing temperature. This may be due to the fact that the frequency feature of ultrasonic wave is affected by not only the specific gravity, acoustic impedence, but material crystalline, porosity, the distance of ultrasonic wave propagation in water.

  • PDF

SCM440 강의 결정입도와 조직의 변화에 따른 초음파 감쇄 (Ultrasonic Attenuation due to the Changes of Grain Size and microstructure of SCM440 Steel)

  • 박은수;강계명;김선진;장순식
    • 한국재료학회지
    • /
    • 제3권6호
    • /
    • pp.585-592
    • /
    • 1993
  • 여러 온도에서 급냉 및 템퍼링시킨 SCM440강을 이용하여 결정입도와 조직의 변화가 초음파감쇄에 미치는 영향에 관하여 연구하였다. 초음파감쇄는 주로 결정립에 의한 산란에 기인하였으며 감쇄계수는 결정립의 크기가 클수록 증가하였으나 템퍼링 시킨 조직의 경우 템퍼링온도가 높아질수록 감쇄계수는 감소하는 것을 알 수 있었다. 주파수의 의존성은 직선적인 log-log 관계를 가지며 Roney의 식과 비례하는 것으로 조사되었다.

  • PDF

초음파의 감쇠를 이용한 복합재료의 기공함량 평가 (Void Contents Evaluation of Composite Laminates by Ultrasonic Attenuation Measurements)

  • 정현조
    • 대한기계학회논문집
    • /
    • 제18권6호
    • /
    • pp.1535-1541
    • /
    • 1994
  • The void content of carbon fiber reinforced composite laminates was determined by the ultrasonic nondestructive technique. The ultrasonic immersion, through-transmission method developed stresses the utilization of spectral analysis and frequency dependence of the attenuation due to porosity. The measured attenuation shows approximately linear behavior over the frequency range investigated. The linear relationship between the void content and the attenuation slop (d $\alpha$/df) is found to hold, but the constant of proportionality is quite different for samples with different pore morphology. The void volume fraction determined by the attenuation slope agreed very well with that obtained by the acid digestion analysis.

초음파 Spectrum 해석에 의한 Creep 손상재의 비파괴평가 (Nondestructive Evaluation of Creep Damage Materials by using Ultrasonic Spectrum Analysis)

  • 김창일;이원;임영호
    • 비파괴검사학회지
    • /
    • 제11권2호
    • /
    • pp.42-47
    • /
    • 1991
  • Nondestructive evaluation study was made on creep damage materials by ultrasonic spectrum analysis. The evaluation methods was developed in order to predict the change of ultrasonic attenuation with increasing creep damage. A new algorithm for the improvement of measuring accuracy of ultrasonic attenuation using a spectrum analysis has been developed. Normally, the ultrasonic attenuation is evaluated from 1st and 2nd peak values of the pulse-echo ultrasonic wave. The algorithm developed is incorporated in a measuring system which consists of a personal computer with ultrasonic apparatus and a digital storage oscilloscope. By the spectrum analysis method, it become popssible to describe approximately the attenuation change with increassing creep damage in Cr-Mo-V forging.

  • PDF

DETECTION OF INTERFACIAL CRACK LENGTH BY USING ULTRASONIC ATTENUATION COEFFICIENTS ON ADHESIVELY BONDED JOINTS

  • Chung, N.Y.;Park, S.I.
    • International Journal of Automotive Technology
    • /
    • 제5권4호
    • /
    • pp.303-309
    • /
    • 2004
  • In this paper, an interfacial crack length has been detected by using the ultrasonic attenuation coefficient on the adhesively bonded double-cantilever beam (DCB) joints. The correlations between energy release rates which were investigated by experimental measurement, the boundary element method (BEM) and Ripling's equation are compared with each other. The experimental results show that the interfacial crack length for the ultrasonic attenuation coefficient and energy release rate increases proportionally. From the experimental results, we propose a method to detect the interfacial crack length by using the ultrasonic attenuation coefficient and discuss it.

초음파 감쇠계수에 의한 균열길이의 측정 (Measurement of Crack Length by Ultrasonic Attenuation Coefficient)

  • 정남용;박성일
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.340-345
    • /
    • 2003
  • In this paper, the ultrasonic attenuation coefficient was measured by variation of crack length for double-cantilever beam(DCB) specimen. The energy release rate, G, was obtained by the experimental measurement of compliance. The experimental results represents that the relation between crack length for the ultrasonic attenuation coefficient and energy release rate is increased proportionally. From the results of experiments, the measurement method of crack length by the ultrasonic attenuation coefficient was proposed and discussed.

  • PDF

접착부재의 초음파 감쇠계수에 의한 계면균열 길이의 측정 (Measurement of Interfacial Crack Length by Ultrasonic Attenuation Coefficients on Adhesively Bonded Components)

  • 정남용;박성일
    • 한국자동차공학회논문집
    • /
    • 제12권1호
    • /
    • pp.130-137
    • /
    • 2004
  • The ultrasonic attenuation coefficients were measured by interfacial crack length in the adhesive components of double-cantilever beam(DCB). The energy release rate, G, was obtained by the experimental measurement of compliance. The numerical analysis by the boundary element method(BEM) and Ripling's equation was investigated. The experimental results represent that the relation between interfacial crack length for the ultrasonic attenuation coefficient and energy release rate is increased proportionally. A measurement method of the interfacial crack length by the ultrasonic attenuation coefficient was proposed and discussed.

초음파 감쇠계수에 의한 균열길이의 측정 (Measurement of Crack Length by Ultrasonic Attenuation Coefficient)

  • 정남용;박성일
    • 대한기계학회논문집A
    • /
    • 제28권4호
    • /
    • pp.386-393
    • /
    • 2004
  • In this paper, the ultrasonic attenuation coefficient was measured by variation of crack length for double-cantilever beam(DCB) specimen. The energy release rate, G, was obtained by the experimental measurement of compliance. The experimental results represents that the crack length for the ultrasonic attenuation coefficient and energy release rate is increases proportionally From the experimental results, we proposed a detecting method of the crack length by the ultrasonic attenuation coefficient and discussed it.

간 병변의 정량화를 위한 초음파 영상 신호의 감쇄상수 추정 (Estimation of Attenuation Coefficient based on Ultrasonic Image for quantification of the Liver Diseases)

  • 우광방;신동호;이성모;신영민;이노성;오성권
    • 대한전자공학회논문지
    • /
    • 제25권1호
    • /
    • pp.49-55
    • /
    • 1988
  • To provide a quantitative parameter of evaluating diagnosis of the liver diseases accurately, the ultrasonic attenuation coefficient was estimated from liver phantoms, 15 normal human livers and 30 liver disease patients. Two kind of phantoms(No.1: 1552m/s, No.2: 1562m/s) which have velocity (1560m/s) similar to that in human liver were constructed and their ultrasonic attenuation coefficients were determined. In this paper the spectral-shift approach and spectral-difference approach were used for estimating ultrasonic attenuation coefficient, \ulcornerdB/Cm.MHz). These two approaches were utilized to esitmate for 15 normal humans without any liver disease and 30 liver disease patients. The results indicate that the two types of phantoms produce the value of near the suggested value of 0.5 and the attenuation coefficients of hepatoma, normal liver, corrhosis, fatty liver and hepatitis show decreasing value in order named, suggesting that the present study can be of clinical value incorrelating the estimated attenuation coefficidents with the liver diseases.

  • PDF