• Title/Summary/Keyword: u-CRM

Search Result 28, Processing Time 0.022 seconds

Rapid Screening of Naturally Occurring Radioactive Nuclides (238U, 232Th) in Raw Materials and By-Products Samples Using XRF

  • Park, Ji-Young;Lim, Jong-Myoung;Ji, Young-Yong;Lim, Chung-Sup;Jang, Byung-Uck;Chung, Kun Ho;Lee, Wanno;Kang, Mun-Ja
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.359-367
    • /
    • 2016
  • Background: As new legislation has come into force implementing radiation safety management for the use of naturally occurring radioactive materials (NORM), it is necessary to establish a rapid and accurate measurement technique. Measurement of $^{238}U$ and $^{232}Th$ using conventional methods encounter the most significant difficulties for pretreatment (e.g., purification, speciation, and dilution/enrichment) or require time-consuming processes. Therefore, in this study, the applicability of ED-XRF as a non-destructive and rapid screening method was validated for raw materials and by-product samples. Materials and Methods: A series of experiments was conducted to test the applicability for rapid screening of XRF measurement to determine activity of $^{238}U$ and $^{232}Th$ based on certified reference materials (e.g., soil, rock, phosphorus rock, bauxite, zircon, and coal ash) and NORM samples commercially used in Korea. Statistical methods were used to compare the analytical results of ED-XRF to those of certified values of certified reference materials (CRM) and inductively coupled plasma mass spectrometry (ICP-MS). Results and Discussion: Results of the XRF measurement for $^{238}U$ and $^{232}Th$ showed under 20% relative error and standard deviation. The results of the U-test were statistically significant except for the case of U in coal fly ash samples. In addition, analytical results of $^{238}U$ and $^{232}Th$ in the raw material and by-product samples using XRF and the analytical results of those using ICP-MS ($R^2{\geq}0.95$) were consistent with each other. Thus, the analytical results rapidly derived using ED-XRF were fairly reliable. Conclusion: Based on the validation results, it can be concluded that the ED-XRF analysis may be applied to rapid screening of radioactivities ($^{238}U$ and $^{232}Th$) in NORM samples.

Effect of abutment superimposition process of dental model scanner on final virtual model (치과용 모형 스캐너의 지대치 중첩 과정이 최종 가상 모형에 미치는 영향)

  • Yu, Beom-Young;Son, Keunbada;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.203-210
    • /
    • 2019
  • Purpose: The purpose of this study was to verify the effect of the abutment superimposition process on the final virtual model in the scanning process of single and 3-units bridge model using a dental model scanner. Materials and methods: A gypsum model for single and 3-unit bridges was manufactured for evaluating. And working casts with removable dies were made using Pindex system. A dental model scanner (3Shape E1 scanner) was used to obtain CAD reference model (CRM) and CAD test model (CTM). The CRM was scanned without removing after dividing the abutments in the working cast. Then, CTM was scanned with separated from the divided abutments and superimposed on the CRM (n=20). Finally, three-dimensional analysis software (Geomagic control X) was used to analyze the root mean square (RMS) and Mann-Whitney U test was used for statistical analysis (${\alpha}=.05$). Results: The RMS mean abutment for single full crown preparation was $10.93{\mu}m$ and the RMS average abutment for 3 unit bridge preparation was $6.9{\mu}m$. The RMS mean of the two groups showed statistically significant differences (P<.001). In addition, errors of positive and negative of two groups averaged $9.83{\mu}m$, $-6.79{\mu}m$ and 3-units bridge abutment $6.22{\mu}m$, $-3.3{\mu}m$, respectively. The mean values of the errors of positive and negative of two groups were all statistically significantly lower in 3-unit bridge abutments (P<.001). Conclusion: Although the number of abutments increased during the scan process of the working cast with removable dies, the error due to the superimposition of abutments did not increase. There was also a significantly higher error in single abutments, but within the range of clinically acceptable scan accuracy.

Web Enabled Expert Systems using Hyperlink-based Inference

  • Yong U. Song;Kim, Wooju;June S. Hong
    • Proceedings of the Korea Inteligent Information System Society Conference
    • /
    • 2003.05a
    • /
    • pp.319-328
    • /
    • 2003
  • With the proliferation of WWW, providing more intelligence to Web sites has become a major concern in e-business industry. In recent days, this trend is more accelerated by prosperity of CRM (Customer Relationship Management) in terms of various aspects such as product recommendation, self after service, etc. To accomplish this goal, many e-companies are eager to embed web enabled rule-based system, that is, expert systems into their Web sites and several well-known commercial tools are already available in the market. Most of those tools are developed based on CGI so far but CGI based systems inherently suffer over-burden problem when there are too many service demands at the same time due to the nature of CGI. To overcome this limitation of the existing CGI based expert systems, we propose a new form of Web-enabled expert system using hyperlink-based inference mechanism. In terms of burden to Web server, our approach is proven to outperform CGI based approach theoretically and also empirically. For practical purpose, our this approach is implemented in a software system, WeBIS and a graphic rule editing methodology, Expert Diagram is incorporated into the system to facilitates rule generation and maintenance. WeBIS is now successfully operated for financial consulting in the web site of a leading financial consulting company in Korea.

  • PDF

A Study on Ubiquitous Convention using RFID (RFID를 활용한 유비쿼터스 컨벤션에 관한 연구)

  • Noh, Young;Byun, Jeung Woo
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.5 no.3
    • /
    • pp.175-184
    • /
    • 2009
  • We are entering into a era of enterprise computing that is characterized by an emphasis on broadband convergence, knowledge s haring, and calm services. Some people refer to this as the "ubiquitous" computing because its focus is on a high degree of connectivity between a company and its customers, suppliers, and channel partners. Ubiquitous computing technology, "RF" stands for "radio frequency"; the "ID" means "identifer". The tag itself of a computer chip and an antenna. The shortest metaphor is that RFID is like a bar-code but is read with an electromagnetic field rather than by a laser beam. Much has already been written about the use of RFID. But there is no has written about the use of RFID in the convention industry. Therefore this study have specific objectives as follows. 1. To give details on the use of RFID in convention. 2. To introduces the key concepts behind RFID technology. 3. To identify advantage & disadvantage of RFID technology using a BEXCO CASE study. 4. To study on ubiquitous convention using RFID and effective operation methods such as entrance identification system, session management, machine management, CRM management, visitor management, and contents management. This results provide into the current status of ubiquitous computing technology in convention industries. Specific advantages by using ubiquitous computing technology(RFID) are one-stop differentiate service, wireless internet service, use of visitor management system, entrance by tag, and U-logistics. On other side, disadvantages are security, stabilization of RFID system, higher price of RFID tag, and commercial scale. Convention by using of RFID technology is currently at an early stage. Convention company as BEXCO need to have the capabilities to adapt, to customize, to commercialize, and to modify technology to suit our circumstances.

Isotope Measurement of Uranium at Ultratrace Levels Using Multicollector Inductively Coupled Plasma Mass Spectrometry

  • Oh, Seong-Y.;Lee, Seon-A.;Park, Jong-Ho;Lee, Myung-Ho;Song, Kyu-Seok
    • Mass Spectrometry Letters
    • /
    • v.3 no.2
    • /
    • pp.54-57
    • /
    • 2012
  • Mass spectrometric analysis was carried out using multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) for the precise and accurate determination of the isotope ratios of ultratrace levels of uranium dissolved in 3% $HNO_3$. We used the certified reference material (CRM) 112-A at a trace level of 100 pg/mL for the uranium isotopic measurement. Multiple collectors were utilized for the simultaneous measurement of uranium isotopes to reduce the signal uncertainty due to variations in the ion beam intensity over time. Mass bias correction was applied to the measured U isotopes to improve the precision and accuracy. Furthermore, elemental standard solution with certified values of platinum, iridium, gold, and thallium dissolved in 3% $HNO_3$ were analyzed to investigate the formation rates of the polyatomic ions of $Ir^{40}$ $Ar^+$, $Pt^{40}$ $Ar^+$, $Tl^{40}$ $Ar^+$, $Au^{40}$ $Ar^+$ for the concentration range of 50-400 pg/mL. Those polyatomic ions have mass-to-charge ratios in the 230-245 m/z region that it would contribute to the increase of background intensity of uranium, thorium, plutonium, and americium isotopes. The effect of the polyatomic ion interference on uranium isotope measurement has been estimated.

Radon Exhalation from Five Wood Species

  • Lee, Ju Yong;Choi, Gyu Woong;Kang, Seog Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.46 no.6
    • /
    • pp.735-747
    • /
    • 2018
  • Radon radiation exposures in home have been posed as a potential cancer hazard. This research aims to present the basic data of the indoor radon concentration level by examining the radon exhalation rates of wood species. Radon exhalation rates from five commonly used wood species in Korean wood building construction were measured with Continuous Radon Monitor (CRM), Model 1028 (Sun Nuclear Co., USA) using the Closed Chamber Method (CCM). The mass exhalation rate was observed to vary from $0.00089Bq{\cdot}kg^{-1}{\cdot}h^{-1}$ to $0.00181Bq{\cdot}kg^{-1}{\cdot}h^{-1}$, whereas the surface exhalation rate was observed to be $0.00677-0.01517Bq{\cdot}m^{-2}{\cdot}h^{-1}$. The radon exhalation rate of Quercus accutissima Carruth (white oak) which has the highest density showed the highest figure among the five wood species, on the other hand, the rest of four species showed similar results which were similar to the radon exhalation rates of wood in the U.S.A. and Canada. The average of the concentration measured by the CCM represented well up to the second half-life period (7.7 days). Because result of these small quantities seems to indicate that radon exhalation from the tested wood species has almost negligible impact, the main culprit of the high indoor radon concentration is clearly derived from the background of surrounding wood house. Therefore, as a safety precaution, infrastructures made of wood materials should be designed with the consideration of influx of radon and built accordingly. Furthermore, it is highly desirable that wood will be needed to use for furniture and interior finishing material in indoor environment.

The Monitoring of Heavy Metals in Human Bloods of Middle School Students (중학생의 혈액 중 중금속 모니터링)

  • Park Hee Ra;Kim Meehye;Kwun Ki-Sung;Kim Soon Ki;Heo Su-Jeong;Kim Kwang_Jin;Yum Tae-Kyung;Choi Kwang Sik;Kim Soo Yeon
    • Journal of Food Hygiene and Safety
    • /
    • v.20 no.2
    • /
    • pp.83-88
    • /
    • 2005
  • This study was conducted to estimate the contents of heavy metals including lead, cadmium, zinc, copper as well as iron status(serum iron, total iron binding capacity, feritin etc)in blood samples of middle school students(n=300). The contents of heavy metals were determined using the GF-AAS (Graphite furnace Atomic Absorption Spectrophotometer). The microwave digestion method and dilution method were compared. The dilution method showed the better recovery and detection limit than microwave digestion method. The values of toxic metals in whloe blood of boys & girls were 3.46 & 3.05 for Pb,0.063 & 0.065 for Cd respectively (ug/dL). Also the values of trace metals in serum of boys & girls were 105.9 & 92.6 for Zn, 98.3 & 99.0 for Cu respectively (ug/dL). The prevalence of iron deficiency was $7.5\%$ in 146 boys and $14.3\%$ in 156 girls. The mean values of lead in girls were higher in iron deficiency, iron deficiency anemia and anemia groups than normal group. The mean values of lead and zinc were higher in boys compared to those in girls(P<0.05), the mean values of cadmium and copper in boys were similar to those in girls. Our results of toxic metals such as Pb & Cd showed lower to CDC's(Centers for Disease Control) blood lead levels of concern for children, 10 ug/dL.

A Study on the Factors Causing Analytical Errors through the Estimation of Uncertainty for Cadmium and Lead Analysis in Tomato Paste (불확도 추정을 통한 토마토 페이스트에서 카드뮴 및 납 분석의 오차 발생 요인 규명)

  • Kim, Ji-Young;Kim, Young-Jun;Yoo, Ji-Hyock;Lee, Ji-Ho;Kim, Min-Ji;Kang, Dae-Won;Im, Geon-Jae;Hong, Moo-Ki;Shin, Young-Jae;Kim, Won-Il
    • Korean Journal of Environmental Agriculture
    • /
    • v.30 no.2
    • /
    • pp.169-178
    • /
    • 2011
  • BACKGROUND: This study aimed to estimate the measurement uncertainty associated with determination of cadmium and lead from tomato paste by ICP/MS. The sources of measurement uncertainty (i.e. sample weight, final volume, standard weight, purity, molecular weight, working standard solution, calibration curve, recovery and repeatability) in associated with the analysis of cadmium and lead were evaluated. METHODS AND RESULTS: The guide to the expression of uncertainty was used for the GUM (Guide to the expression of Uncertainty in Measurement) and Draft EURACHEM/CITAC (EURACHEM: A network of organization for analytical chemistry in Europe/Co-Operation on International Traceability in Analytical Chemistry) Guide with mathematical calculation and statistical analysis. The uncertainty components were evaluated by either Type A or Type B methods and the combined standard uncertainty were calculated by statistical analysis using several factors. Expected uncertainty of cadmium and lead was $0.106{\pm}0.015$ mg/kg (k=2.09) and $0.302{\pm}0.029$ mg/kg (k=2.16), on basis of 95% confidence of Certified Reference Material (CRM) which was within certification range of $0.112{\pm}0.007$ mg/kg for cadmium (k=2.03) and $0.316{\pm}0.021$ mg/kg for lead (k=2.01), respectively. CONCLUSION(s): The most influential components in the uncertainty of heavy metals analysis were confirmed as recovery, standard calibration curve and standard solution were identified as the most influential components causing uncertainty of heavy metal analysis. Therefore, more careful consideration is required in these steps to reduce uncertainty of heavy metals analysis in tomato paste.