• Title/Summary/Keyword: type 347

Search Result 261, Processing Time 0.025 seconds

Study on the Charging Characteristics of a Sealed Type Ni-Cd Cell (밀폐식 Ni-Cd 전지의 충전특성에 관한 연구)

  • Yung Woo Park;Chai Won Kim;Mu Shik Jhon
    • Journal of the Korean Chemical Society
    • /
    • v.15 no.6
    • /
    • pp.347-352
    • /
    • 1971
  • The variations of the positive and negative electrode potentials, and of internal pressure were measured during the charge of the sealed type Ni-Cd cell. Both polarization characteristics of a paste type Cd-electrode as a gas diffusion electrode in 30% KOH solution and the effects of active carbon electrode as an oxygen consuming auxiliary electrode of the Ni-Cd cell on the charging characteristics of the cell were studied. Peak voltage at the end of charge of the cell is ascribed to the peak at the negative electrode potential, which is due to the concentration polarization by the lack of $Cd^{++}$ ion and oxygen concentration. And the recovery of the negative electrode potential is resulted from depolarization by the increasing diffusion limiting current density with the increasing oxygen pressure. The active carbon electrode was effective as an oxygen consuming auxiliary electrode. The internal pressure of the cell could be maintained below 200mmHg even at one hour rate charge and overcharge by the use of active carbon electrode as an auxiliary electrode.

  • PDF

Upregulation of Renin-angiotensin, Endothelin and C-type Natriuretic Peptide in Rat Glomerulus with Bilateral Ureteral Obstruction

  • Bae, Eun-Hui;Kim, Soo-Wan
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.10 no.6
    • /
    • pp.343-347
    • /
    • 2006
  • The present study was designed to investigate the effects renin-angiotensin-aldosterone system (RAAS), endothelin (ET) and local natriuretic peptide (NP) system for glomerulopathy induced in the experimental bilateral ureteral obstructive rats. Sprague-Dawley male rats ($200{\sim}220g$ body weight) were bilaterally obstructed by ligation of the proximal ureters for 24 hours. Control rats were treated in the same ways, except that no ligature was made. The glomeruli were isolated from cortex by graded sieve methods, and the mRNA expressions of local renin-angiotensin system (RAS), aldosterone synthase (CYP11B2), endothelin-1 (ET-1) and NP system were determined by real-time polymerase chain reaction. Following the bilateral ureteral obstruction, the mRNA expressions of renin, angiotensin converting enzyme 1 as well as ET-1 were increased, while that of angiotensin converting enzyme 2 was not changed. The expressions of CYP11B2 and angiotensin II receptors were not changed. C-type natriuretic peptide (CNP) expression was increased, while its receptors (natriuretic peptide receptor-B) were not changed. We suggest that the upregulation of local RAS and ET playa role in the progressive glomerular injury, and that the enhanced CNP activity also plays a compensatory role in obstructive uropathy in the glomerulus.

Structural Performance of H-shaped Column-Rafter Connection in the P.E.B Systematic Steel Frames (P.E.B 시스템 강골조에서 H형강 기둥 - Rafter 접합부의 구조성능)

  • Kim, Jong Sung
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.3 s.76
    • /
    • pp.347-356
    • /
    • 2005
  • Recently, pre-engineering building (P.E.B.) systematic frames are increasingly being used in steel factory buildings, but almost of the related techniques are dependent on the engineering program (e.g, MBS, LTI), which is usually imported from other countries. These are designed under the AISC-ASD because at present there is no Korean design code for P.E.B. frames. Also, there are few studies onbehaviour and we need to develop the element techniques by using H-shaped components.In particular, there is a tendency towards overestimated design because column-rafter connections have been designed with extended end plate type joint, which is treated asrigid joint,so structural examinations are needed. Therefore, this study represents a basic step in ascertaining the application of P.E.B. systematic frames by using H-shaped column-rafter connectionwith flush type end plate. Its structural performance is compared with that of existing extended type joint using a structural performance test. The structural behaviour of specimen was understood qualitatively and the possibility of application (e.g, design aid charts) of semi-connection (flush type) with H-shaped column-rafter was determined.

Wave and Wave Board Motion of Hybrid Wave Maker (다기능 조파기의 조파 운동과 발생 파형)

  • Kim, Hyochul;Oh, Jungkeun;Lew, Jae-Moon;Rhee, Shin Hyung;kim, Jae Heon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.58 no.6
    • /
    • pp.339-347
    • /
    • 2021
  • Piston type wave makers or flap type wave makers are usually adopted as a wave maker which disturbing the fluid domain with sinusoidal motion. Recently hybrid wave maker which could be operated as not only piston type and/or flap type but also swing type wave maker have been devised by utilizing the link mechanism. The wave board of hybrid wave maker has been devised to be independently controlled by the horizontal actuators on upper and lower end of the wave board. The wave board could operate as a flap type wave board when the lower hinge is in a stationary condition and the upper hinge is operated with sinusoidal motion. On the contrary, the swing type wave board could be obtained by the lower hinge is activated and the upper hinge is in a stationary condition. When both end of the wave board is activated in a synchronized condition, the wave board motion become piston motion. In addition the hybrid wave maker could enhance the piston motion with flap motion or swing motion by selecting control parameters. Various wave board motion of hybrid wave maker and relevant wave form have measured on the wave board and departed location. It is appeared that the novel hybrid wave maker could be utilized for the improvement of wave qualities in experiments.

Bronchoscopic Electrocautery for Airway Obstruction in The Tumorous Type of Endobronchial Tuberculosis (종양형 기관지결핵에서 기도협착에 대한 기관지경적 전기소작요법)

  • Chung, Hee-Soon;Hyun, In-Gyu;Han, Sung-Koo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.38 no.4
    • /
    • pp.347-356
    • /
    • 1991
  • Endobronchial tuberculosis is a serious disase because it frequently leaves airway obstruction as the complication, and the treatment of airway obstruction is generally troublesome. In the tumorous type of endobonchial tuberculosis, the bronchial patency is partially or completely compromised with lymph node contents when the necrotic focus of the lymph node ruptures into the bronchial lumen to form a bronchoglandular fistula. To investigate the transition of endobronchial lesion and to evaluate the therapeutic role of bronchoscopic electrocautery in the tumorous type of endobronchial tuberculosis, we performed electrocautery in addition to the combination chemotherapy with steroid and anti-tuberculous drugs in two cases which had airway obstruction proximal to lobar bronchus with the impairment of pulmonary function. We also treated another two cases only with chemotherapy and we have followed up four cases over a 36-month period. In cases that bronchoscopic electrocautery was done, the bronchial patency was completely restored and the impairment of pulmonary function disappeared just after cautery and these effects have remained for 12 months or more. But in cases of medical treatment only, bronchial stenosis was inevitable as the tumorous type of endobronchial tuberculosis changed to the stenotic type with fibrosis. It can be concluded that bronchoscopic electrocautery can nip the occurence of bronchial stenosis in the bud when it is applied in addition to combination chemotherapy with steroid and antituberculous drugs in the tumorous type of endobronchial tuberculosis.

  • PDF

The characteristics of $p^+$-InGaAs layer implanted with oxygen (Oxygen이 주입된 $p^+$-InGaAs층에서의 compensation 특성)

  • 시상기;김성준
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.4
    • /
    • pp.343-347
    • /
    • 1997
  • The dependence of compensation mechanism in $P^+$-InGaAs layer implanted with oxygen on the annealing temperatures was investigated. The oxygen implantation was performed for electrical isolation. The conductivity was controlled by damage related traps below $500^{\circ}C$. For the temperature of 500 to $600^{\circ}C$, oxygen began to show the chemical effect of compensating the acceptors due to activation and type conversion (plongrightarrown-type) occurred at $600^{\circ}C$. This indicates that the defects generated by the chemical activity of oxygen increased with increasing annealing temperature, where activation energy of 24.2 meV was obtained. It is attributed to the formation of native defects, such as In interstitials, acting as shallow donor in InGaAs. Above $600^{\circ}C$, the interstitial Be atoms become reactivated and the n-type conductivity decreases.

  • PDF

Development of hybrid artificial reef and basic structural performance tests (복합형 인공어초의 개발 및 구조 성능 평가)

  • Ko, Hune-Bum;Kim, Hee-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.341-347
    • /
    • 2018
  • The purpose of this study is to develop a new type of hybrid artificial reef that can solve the problems of construction, installation and operation of existing concrete type and steel type artificial reef, and to evaluate basic structural performance through static loading test. For this purpose, we evaluated the strengths and weaknesses of concrete type and steel type artificial reef in literature, and developed a new type of hybrid artificial reef which can effectively overcome the problems of each artificial reefs while maintaining the advantages of two artificial reefs as an alternative respectively. In order to evaluate the merits of the proposed hybrid artificial reef, it was confirmed that the possibility of securing the convenience of the proposed hybrid artificial reef in the field and the possibility of securing the desired advantages were confirmed. Also, the static loading test was performed to evaluate the basic structural performance of the artificial reef. Through the above study, it was confirmed that the developed hybrid artificial reef exhibited proper structural performance while securing easiness of making and assemble.mm) can be predicted to have a low value up to 60% of the strength of cylinders without reinforcement.

Distribution Characteristics of Geologic Age and Rock Type of Bedrocks at the National Wood Culture Heritage Site by GIS (GIS에 의한 국가지정 목조문화재 기반암류의 지질시대별 및 암층별 분포특성)

  • Yun, Hyun-Soo;Lee, Jin-Young;Kim, Yong-Won;Hong, Sei-Sun;Kim, Eun-Kyung
    • The Journal of the Petrological Society of Korea
    • /
    • v.24 no.4
    • /
    • pp.347-364
    • /
    • 2015
  • The purpose of the work was carried out to contribute the factors related to geologic realm in the disaster stability evaluation items of the national wood culture heritages. Among the total heritages, the study targets mainly include 304 cases interpreted as a rock type in the geologic map of the bedrocks with GIS interpretation. The cases show the geologic ages, geologic provinces and rock types as the following distribution characteristics. In geologic ages, they are decreasing in the orders of Jurassic, Cretaceous, Quaternary, Precambrian, Age-unknown Cambro-Ordovician Carboniferous and Tertiary. Among the ages, the former fours occupy 285 cases (93.8%) of the targets, which show most of the wood culture heritages. In geologic provinces classified into 15, they are decreasing in the orders of Daebo intrusives, alluvium, Gyeongsang supergroup, Bulgugsa intrusives, Yeongnam massif, and Gyeonggi massif which occupy of predominant distribution 271 cases (89.1%) of them. In rock types of 52, those of 6, which are Jgr, Qa, Kp, Krt+Kav+Kav1+Kav2, Kbgr and GC2, occupy total 182 cases (59.9%) showing distinctly dominant trends from the rest of 46.

Botulinum Toxin type A injection Versus Lidocaine Injection for Myofascial Pain Involving upper Trapezius (승모근 근막동통에 대한 보툴리눔 독소와 리도카인 주사의 치료효과 비교)

  • Ahn, Sung-Woo;Park, Eun-Hee;Kim, Mee-Eun
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.3
    • /
    • pp.345-351
    • /
    • 2005
  • The purpose of this double-blind study was to evaluate clinical effects of botulinum toxin type A (BTX-A) injection on myofascial pain syndrome (MPS) involving upper trapezius and compare with those of lidocaine injection. 21 patients presenting with active TrP1 and/or TrP2 in the upper trapezius over 6 months were selected for this study. The subjects were randomly divided into two groups; one group injected with BTX-A (15 unit of $Botox^{(R)}$ / 0.3 ml per trigger point (TrP)) and the other group injected with 0.5% lidocaine (0.3 ml /TrP). The clinical effects were evaluated by VAS and PPT at baseline, 2, 4, 6 and 8 weeks after treatment. BTX-A group showed persistent decrease of VAS values and increase of PPT values following treatment. While there was no significant difference in VAS values between BTX-A and lidocaine groups (p=0.347), there was significant difference in PPT values after treatment between two groups (p=0.000). The subjects received BTX-A showed noticeable improvement in PPT values after treatment, suggesting more reliable effect of BTX-A injection compared with lidocaine injection. The results of this study support that the direct injection of BTX-A to a TrP is an effective and safe treatment for MPS involving upper trapezius.

Design and operational characteristics of cw and KLM Ti : sapphire lasers with a symmetric Z-type cavity configuration (Z-형태의 대칭형 레이저 공진기 구조를 갖는 연속 발진 및 Kerr-렌즈 모드-록킹되는 티타늄 사파이어 레이저의 설계와 동작 특성)

  • Choo, Han-Tae;Ahn, Bum-Soo;Kim, Gyu-Ug;Lee, Tae-Dong;Yoon, Byoung-Won
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.4
    • /
    • pp.347-355
    • /
    • 2002
  • We have constructed a high efficiency and broad tunable cw Ti:sapphire laser with a four-mirror symmetric Z-type laser cavity to increase the laser usability. From theoretical analyses and experimental data for a symmetric Z-type laser cavity containing a Kerr medium, the cavity mode size and the Kerr-lens mode-locking (KLM) strength for KLM lasers can be confirmed as function of the position in the cavity, the intracavity laser power, and the stability parameter. As a result, the slope efficiency and the maximum average output power of cw Ti:sapphire laser at 5 W pumping power of Ar-ion laser were 31.3% and 1420 ㎽ respectively. The tunablility was ranged from 730 ㎚ to 908 ㎚ with average output power above 700 ㎽. We obtained the KLM operation easily by self-aperturing effect in the Kerr medium and the slope efficiency and the maximum average output power of KLM Ti:sapphire laser was 16% and 550 ㎽ respectively. The spectral bandwidth was 33 ㎚ at the center wavelength of 807 ㎚ and the pulse width was 27 fs with a repetition rate of 82 ㎒.