• Title/Summary/Keyword: two-phase system

Search Result 2,661, Processing Time 0.034 seconds

Scott Transformer Modeling using Simulink on the AC Substation (Simulink를 이용한 교류 급전변전소의 스코트변압기 모델링)

  • Kim, Tae-Geun;Park, Young;Lee, Jong-Woo
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2317-2322
    • /
    • 2011
  • In three-phase power, when the power is supplied to the single phase load, there is the unbalance of load in the three-phase power. So the scott transformer is used in the power system to supply a single phase load in three-phase power without the unbalance of loads. Especially, the scott transformer is used in the AC substation of electric railroad. Two single phase transformers are combined by T-wiring in the scott transformer. So, two single phase voltage is provided by differing $90^{\circ}$ phase in three-phase power. The selection of related equipment and correction of protective relay are not easy from characteristic of the scott transformer when shunt and ground faults occur. In this paper, electric model of the scott transformer is suggested and the current of the scott transformer in shunt and ground faults is analyzed. Also, the scott transformer model is demonstrated by using Sinulink.

  • PDF

Scott Transformer Modeling using PSIM on the AC Substation in the Elect ric Railroad (전기철도의 교류 급전변전소에서 PSIM을 이용한 스코트변압기 모델링)

  • Kim, Sung-Dae;Choi, Kyu-Hyoung
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1892-1897
    • /
    • 2010
  • In three-phase power, when the power is supplied to the single phase load, there is the unbalance of load in the three-phase power. So the scott transformer is used in the power system to supply a single phase load in three-phase power without the unbalance of loads. Especially, the scott transformer is used in the AC substation of electric railroad. Two single phase transformers are combined by T-wiring in the scott transformer. So, two single phase voltage is provided by differing $90^{\circ}$ phase in three-phase power. The selection of related equipment and correction of protective relay are not easy from characteristic of the scott transformer when shunt and ground faults occur. PSIM(Power Electronics Simulator) is optimal simulation software in field of the power electronics and provide the simple and convenient user interface. In this paper, electric model of the scott transformer is suggested and the current of the scott transformer in shunt and ground faults is analyzed. Also, the scott transformer model is demonstrated by using PSIM.

  • PDF

Recovery of High-Purity Methane from Piggery Wastewater in the Phase-Separated Anaerobic Process (상분리 혐기성공정에 의한 양돈폐수로부터 고순도 메탄회수)

  • Jung, Jin-Young;Chung, Yun-Chul;Yoo, Chang-Bong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.210-213
    • /
    • 2008
  • The purpose of this study is to investigate the performances of organic removal and methane recovery in the full scale two-phase anaerobic system. The full scale two-phase anaerobic system was consists of an acidogenic ABR (Anaerobic Baffled Reactor) and a methanognic UASB (Upflow Anaerobic Sludge Blanket) reactor. The volume of acidogenic and methanogenic reactors is designed to 28.3 $m^3$ and 75.3 $m^3$. The two-phase anaerobic system represented 60-82% of COD removal efficiency when the influent COD concentration was in the range of 7,150 to 16,270 mg/L after screening (average concentration is 10,280 mg/L). After steady-state, the effluent COD concentration in the methanogenic reactor showed 2,740 $\pm$ 330 mg/L by representing average COD removal efficiency was 71.4 $\pm$ 8.1% when the operating temperature was in the range of 19-32$^{\circ}C$. The effluent SCOD concentration was in the range of 2,000-3,000 mg/L at the steady state while the volatile fatty concentration was not detected in the effluent. Meanwhile, the COD removal efficiency in the acidogenic reactor showed less than 5%. The acidogenic reactor played key roles to reduce a shock-loading when periodic shock loading was applied and to acidify influent organics. Due to the high concentration of alkalinity and high pH in the effluent of the methanogenic reactor, over 80% of methane in the biogas was produced consistently. More than 70 % of methane was recovered from theoretical methane production of TCOD removed in this research. The produced gas can be directly used as a heat source to increase the reactor temperature.

  • PDF

Removal of bias and conjugate image using the modified conoscopic holography (변형된 코노스코픽 홀로그래피를 이용한 바이어스와 공액영상의 제거)

  • Kim, Soo-Gil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.22-27
    • /
    • 2015
  • Conoscopic holography, which consists of two linear polarizers and two wave plates, and an uniaxial crystal, is incoherent holographic technology for three-dimensional display. In the uniaxial crystal, the wave from object divides into extraordinary and ordinary waves and phase difference between two waves is caused by the different refractive index of two waves. Four intensity patterns, which are made by phase difference, are obtained using LCLV(liquid crystal light valve) and conoscopic holography system. By combining four intensity patterns, the complex hologram without bias and conjugate image. In this paper, we propose the optimized system, which consists of a wave plate and a linear polarizer, and uniaxial crystal. In the proposed system, it doesn't need LCLV. By adjusting the azimuth angle of a linear polarizer and a wave plate, we derive four intensity patterns in recording plane. We demonstrate theoretically that the complex hologram with bias and a conjugate image is obtained using the proposed system.

Single-phase Active Power Filter Based on Rotating Reference Frame Method for Harmonics Compensation

  • Kim, Jin-Sun;Kim, Young-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.94-100
    • /
    • 2008
  • This paper presents a new control method of single-phase active power filter (APF) for the compensation of harmonic current components in nonlinear loads. To facilitate the possibility of complex calculation for harmonic current detection of the single phase, a single-phase system that has two phases was constructed by including an imaginary second-phase giving time delay to the load current. The imaginary phase, which lagged the load current T/4 (Here T is the fundamental cycle) is used in the conventional method. But in this proposed method, the new signal as the second phase is delayed by the filter. Because this control method is applied to a single-phase system, an instantaneous calculation was developed by using the rotating reference frames synchronized to source-frequency rather than by applying instantaneous reactive power theory that uses the conventional fixed reference frames. The control scheme of single-phase APF for the current source with R-L loads is applied to a laboratory prototype to verify the proposed control method.

Performance Evaluation of the Complex-Coefficient Adaptive Equalizer Using the Hilbert Transform

  • Park, Kyu-Chil;Yoon, Jong Rak
    • Journal of information and communication convergence engineering
    • /
    • v.14 no.2
    • /
    • pp.78-83
    • /
    • 2016
  • In underwater acoustic communication, the transmitted signals are severely influenced by the reflections from both the sea surface and the sea bottom. As very large reflection signals from these boundaries cause an inter-symbol interference (ISI) effect, the communication quality worsens. A channel estimation-based equalizer is usually adopted to compensate for the reflected signals under the acoustic communication channel. In this study, a feed-forward equalizer (FFE) with the least mean squares (LMS) algorithm was applied to a quadrature phase-shift keying (QPSK) transmission system. Two different types of equalizers were adopted in the QPSK system, namely a real-coefficient equalizer and a complex-coefficient equalizer. The performance of the complex-coefficient equalizer was better than that of two real-coefficient equalizers. Therefore, a Hilbert transform was applied to the real-coefficient binary phase-shift keying (BPSK) system to obtain a complex-coefficient BPSK system. Consequently, we obtained better results than those of a real-coefficient equalizer.

Synchronization of Chaos in the Lorenz System by Variable Feedback (Lorenz계에서 변수의 되먹임에 의한 혼돈의 동기화)

  • Kim, Chil-Min
    • The Journal of Natural Sciences
    • /
    • v.9 no.1
    • /
    • pp.75-81
    • /
    • 1997
  • The method of synchronization by feedbacking a signal of master system to a corresponding variable of slave system is applied to the Lorenz which is autonomous system. The two Lorenz systems are synchronized and the synchronization occurs when the consisting of the variable differences of the two systems generates infinite period of laminar phase. The characteristics of synchronization is analyzed in time series and phase spaces.

  • PDF

Assessment of Fuzzy Measure Possibility for the Electromagnetic Field of unbalanced two coupled Three-phase Transmission line Considering toad-Voltage Characteristics (부하의 전압특성을 고려한 3상 2회선 불평형 송전선로에서의 전자계에 대한 퍼지척도 가능성평가)

  • 송현선;김상철
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.3
    • /
    • pp.45-52
    • /
    • 2001
  • This paper presents a study on the assessment of fuzzy measure possibility for the electromagnetic field of unbalanced system. It takes into account m untransposed transmission line and unbalanced load. A three phase load flow program was developed which employs a Newton-Raphson method as a tool to analyze system unbalanced. This research presents a method of handling two coupled three phase transmission system unbalance analysis and unbalanced power demand as a function of voltages. In assessment of fuzzy measure possibility for the electromagnetic field, this paper use probability of fuzzy and measure of fuzziness technique.

  • PDF

Applying Aqueous Two Phase Systems to Multi-layer Cosmetics (다중 층 화장료에서 수성 이상계의 응용)

  • Hong, Junki;You, Jaewon;Yoo, Jangyung;Nam, Seungok;Lee, Sanggil;Pyo, Hyeongbae
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.39 no.2
    • /
    • pp.83-88
    • /
    • 2013
  • The aqueous two phase system has biocompatibility, because it is physically separated into an immiscible liquid multi-layer induced by incompatibility among hydrophilic components dissolved in the water phase. we have applied this principle to aqueous multi-layer liquid cosmetics and select two representative systems. What it was experimentally obtained was the phase diagrams including a binodal curve, a critical point, tie lines of concentration and tie curves of phase separating volume ratio and phase separating time. From the phase diagrams, we were able to observe existence of the optimum condition to prepare the aqueous multi-layer cosmetics for the systems.

A Faulted Phase Discrimination Algorithm in Ungrounded Distribution System (비접지 배전선로의 고장상 판별 알고리즘 개발)

  • 이덕수;임성일;최면송;이승재
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.2
    • /
    • pp.114-120
    • /
    • 2003
  • According to the use of distribution automation systems, the function to find or to search a fault phase is necessary for automatic switches in a distribution substation. In this paper, two algorithms are developed to fine the fault circuit and the fault phase for the automatic switches in substation with ungrounded power system. One is the fault circuit searching method using the zero sequence voltage at the bus and zero sequence current of circuit current and the other is to find the fault phase using the line voltage and zero sequence current. The developed algorithms are tested in the case study simulations. An ungrounded power system is modeled by EMTP as a case study system. The developed algorithms are tested in the case study simulations and each shows correct results.