• Title/Summary/Keyword: two-dimensional radiotherapy

Search Result 70, Processing Time 0.021 seconds

Advances and Challenges in Intensity-Modulated Radiotherapy for Nasopharyngeal Carcinoma

  • Qu, Song;Liang, Zhong-Guo;Zhu, Xiao-Dong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.5
    • /
    • pp.1687-1692
    • /
    • 2015
  • Nasopharyngeal carcinoma is an endemic disease within specific regions in the world. Radiotherapy is the main treatment. In recent decades, intensity-modulated radiation therapy has undergone a rapid evolution. Compared with two-dimensional radiotherapy and/or three-dimensional conformal radiotherapy, evidence has shown it may improve quality of life and prognosis for patients with nasopharyngeal carcinoma. In addition, helical tomotherapy is an emerging technology of intensity-modulated radiation therapy. Its superiority in dosimetric and clinical outcomes has been demonstrated when compared to traditional intensity-modulated radiation therapy. However, many challenges need to be overcome for intensity-modulated radiation therapy of nasopharyngeal carcinoma in the future. Issues such as the status of concurrent chemotherapy, updating of target delineation, the role of replanning during IMRT, the causes of the main local failure pattern require settlement. The present study reviews traditional intensity-modulated radiation therapy, helical tomotherapy, and new challenges in the management of nasopharyngeal carcinoma.

Retrospective analysis of intensity-modulated radiotherapy and three-dimensional conformal radiotherapy of postoperative treatment for biliary tract cancer

  • Lee, Hyo Chun;Lee, Jong Hoon;Lee, Sea-Won;Lee, Joo Hwan;Yu, Mina;Jang, Hong Seok;Kim, Sung Hwan
    • Radiation Oncology Journal
    • /
    • v.37 no.4
    • /
    • pp.279-285
    • /
    • 2019
  • Purpose: This study was conducted to compare the outcome of three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) for the postoperative treatment of biliary tract cancer. Materials and Methods: From February 2008 to June 2016, 57 patients of biliary tract cancer treated with curative surgery followed by postoperative 3D-CRT (n = 27) or IMRT (n = 30) were retrospectively enrolled. Results: Median follow-up time was 23.6 months (range, 5.2 to 97.6 months) for all patients and 38.4 months (range, 27.0 to 89.2 months) for survivors. Two-year recurrence-free survival is higher in IMRT arm than 3D-CRT arm with a marginal significance (25.9% vs. 47.4%; p = 0.088). Locoregional recurrence-free survival (64.3% vs. 81.7%; p = 0.122) and distant metastasis-free survival (40.3% vs. 55.8%; p = 0.234) at two years did not show any statistical difference between two radiation modalities. In the multivariate analysis, extrahepatic cholangiocarcinoma, poorly-differentiated histologic grade, and higher stage were significant poor prognostic factors for survival. Severe treatment-related toxicity was not significantly different between two arms. Conclusions: IMRT showed comparable results with 3D-CRT in terms of recurrence, and survival, and radiotherapy toxicity for the postoperative treatment of biliary tract cancer.

Synthetic Computed Tomography Generation while Preserving Metallic Markers for Three-Dimensional Intracavitary Radiotherapy: Preliminary Study

  • Jin, Hyeongmin;Kang, Seonghee;Kang, Hyun-Cheol;Choi, Chang Heon
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.172-178
    • /
    • 2021
  • Purpose: This study aimed to develop a deep learning architecture combining two task models to generate synthetic computed tomography (sCT) images from low-tesla magnetic resonance (MR) images to improve metallic marker visibility. Methods: Twenty-three patients with cervical cancer treated with intracavitary radiotherapy (ICR) were retrospectively enrolled, and images were acquired using both a computed tomography (CT) scanner and a low-tesla MR machine. The CT images were aligned to the corresponding MR images using a deformable registration, and the metallic dummy source markers were delineated using threshold-based segmentation followed by manual modification. The deformed CT (dCT), MR, and segmentation mask pairs were used for training and testing. The sCT generation model has a cascaded three-dimensional (3D) U-Net-based architecture that converts MR images to CT images and segments the metallic marker. The performance of the model was evaluated with intensity-based comparison metrics. Results: The proposed model with segmentation loss outperformed the 3D U-Net in terms of errors between the sCT and dCT. The structural similarity score difference was not significant. Conclusions: Our study shows the two-task-based deep learning models for generating the sCT images using low-tesla MR images for 3D ICR. This approach will be useful to the MR-only workflow in high-dose-rate brachytherapy.

Chemotherapy and Late Course Three Dimensional Conformal Radiotherapy for Treatment of Patients with Stage III Non-small Cell Lung Cancer

  • Liu, Yang-Chen;Zhou, Shao-Bing;Gao, Fei;Ye, Hong-Xun;Zhao, Ying;Yi, Xiao-Xiang;Huang, Xin-En;Xiang, Jin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.4
    • /
    • pp.2663-2665
    • /
    • 2013
  • Objective: To compare the efficacy and complications of chemotherapy and late course three-dimensional conformal radiotherapy (3DCRT) in treating patients with stage III non-small cell lung cancer (NSCLC). Patients and Methods: All patients were divided into two groups: to receive chemotherapy and late course 3DCRT (3DCRT group), or chemotherapy and conventional fraction radiation (control group). In the 3DCRT-group, patients were given 6~15 MV X-rays with a total dose of 40 Gy, followed by 3DCRT, 2.5 Gy~3.0 Gy per fraction, 1 fraction/every day, total 68 Gy~70 Gy; in the control group, with conventional fraction radiation the total dose was 64~66 Gy. The chemotherapy regimen in both cases was EP (VP-16 and DDP). Results: Sixty four patients with stage III NSCLC were divided into two groups: 32 patients into 3DCRT, 32 into the control group. One and 2-year survival rates in 3DCRT and control group were 87.5%, 56.3%mad 65.6%, 34.4%, respectively (P<0.05); local control rates were 90.6%, 81.3% and 65.6%, 53.1%, respectively (P<0.05). Conclusion: Chemotherapy and late course 3DCRT is associated with improved survival rate in patients with stage III NSCLC with good tolerability.

Clinical Observation of Three Dimensional Conformal Radiotherapy with Tamoxifen in Treatment of Postoperative Malignant Glioma

  • Zhou, Shao-Bing;Liu, Yang-Chen;Yin, Xiao-Xiang;Ding, Wen-Xiu;Guo, Xin-Wei;Gu, Liang;Huang, Xin-En
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.5
    • /
    • pp.1743-1745
    • /
    • 2015
  • Objective: To evaluate the efficacy and adverse effects of three dimensional conformal radiotherapy (3D-CRT) with tamoxifen in treating patients with postoperative malignant glioma. Patients and Methods: 60 patients of postoperative malignant glioma were randomly assigned into two groups, 30 patients were treated with 3D-CRT plus tamoxifen (treatment group), and the other 30 patients with 3D-CRT plus temozolomide (control group). All patients were radiated by 6MV X-ray, 2.0Gy per fraction, once daily, with a total dose (DT) of 56~60Gy. Tamoxifen was delivered at $60mg/m^2/d$, temozolomide was given at $75mg/m^2/d$. All patients were treated with concurrent radiotherapy. Results: One, 2, 3 year survival rates of treatment and control group were 63.3%, 30.0%, 23.0% and 70.0%, 33.3%, 26.7%, respectively (${\chi}^2=0.01$, 0.23, 0.09, P>0.05). The rate of thromboembolism in treatment group was 6.7%. Conclusion: Therapeutic efficacy of two groups was similar, but it was more cost-effective in treatment group, and toxicity did not increase.

Dosimetric Comparison between Intensity Modulated Radiotherapy and 3 Dimensional Conformal Radiotherapy in the Treatment of Rectal Cancer

  • Simson, David K;Mitra, Swarupa;Ahlawat, Parveen;Sharma, Manoj Kumar;Yadav, Girigesh;Mishra, Manindra Bhushan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.11
    • /
    • pp.4935-4937
    • /
    • 2016
  • Objective: To compare dosimetric parameters of 3 dimensional conformal radiotherapy (3 DCRT) and intensity modulated radiotherapy (IMRT) in terms of target coverage and doses to organs at risk (OAR) in the management of rectal carcinoma. Methods: In this prospective study, conducted between August 2014 and March 2016, all patients underwent CT simulation along with a bladder protocol and target contouring according to the Radiation Therapy Oncology Group (RTOG) guidelines. Two plans were made for each patient (3 DCRT and IMRT) for comparison of target coverage and OAR. Result: A total of 43 patients were recruited into this study. While there were no significant differences in mean Planning Target Volume (PTV) D95% and mean PTV D98% between 3 DCRT and IMRT, mean PTV D2% and mean PTV D50% were significantly higher in 3 DCRT plans. Compared to IMRT, 3 DCRT resulted in significantly higher volumes of hot spots, lower volumes of cold spots, and higher doses to the entire OAR. Conclusion: This study demonstrated that IMRT achieves superior normal tissue avoidance (bladder and bowel) compared to 3 DCRT, with comparable target dose coverage.

Comparison of 2-Dimensional and 3-Dimensional Conformal Treatment Plans in Gastric Cancer Radiotherapy

  • Adas, Yasemin Guzle;Andrieu, Meltem Nalca;Hicsonmez, Ayse;Atakul, Tugba;Dirican, Bahar;Aktas, Caner;Yilmaz, Sercan;Akyurek, Serap;Gokce, Saban Cakir;Ergocen, Salih
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.17
    • /
    • pp.7401-7405
    • /
    • 2014
  • Background: Postoperative chemoradiotherapy is accepted as standard treatment for stage IB-IV, M0 gastric cancer. Radiotherapy (RT) planning of gastric cancer is important because of the low radiation tolerance of surrounding critical organs. The purpose of this study was to compare the dosimetric aspects of 2-dimensional (2D) and 3-dimensional (3D) treatment plans, with the twin aims of evaluating the adequacy of 2D planning fields on coverage of planning target volume (PTV) and 3D conformal plans for both covering PTV and reducing the normal tissue doses. Materials and Methods: Thirty-six patients with stage II-IV gastric adenocarcinoma were treated with adjuvant chemoradiotherapy using 3DRT. For each patient, a second 2D treatment plan was generated. The two techniques were compared for target volume coverage and dose to normal tissues using dose volume histogram (DVH) analysis. Results: 3DRT provides more adequate coverage of the target volume. Comparative DVHs for the left kidney and spinal cord demonstrate lower radiation doses with the 3D technique. Conclusions: 3DRT produced better dose distributions and reduced radiation doses to left kidney and spinal cord compared to the 2D technique. For this reason it can be predicted that 3DRT will result in better tumor control and less normal tissue complications.

Efficient approach for determining four-dimensional computed tomography-based internal target volume in stereotactic radiotherapy of lung cancer

  • Yeo, Seung-Gu;Kim, Eun Seog
    • Radiation Oncology Journal
    • /
    • v.31 no.4
    • /
    • pp.247-251
    • /
    • 2013
  • Purpose: This study aimed to investigate efficient approaches for determining internal target volume (ITV) from four-dimensional computed tomography (4D CT) images used in stereotactic body radiotherapy (SBRT) for patients with early-stage non-small cell lung cancer (NSCLC). Materials and Methods: 4D CT images were analyzed for 15 patients who received SBRT for stage I NSCLC. Three different ITVs were determined as follows: combining clinical target volume (CTV) from all 10 respiratory phases ($ITV_{10Phases}$); combining CTV from four respiratory phases, including two extreme phases (0% and 50%) plus two intermediate phases (20% and 70%) ($ITV_{4Phases}$); and combining CTV from two extreme phases ($ITV_{2Phases}$). The matching index (MI) of $ITV_{4Phases}$ and $ITV_{2Phases}$ was defined as the ratio of $ITV_{4Phases}$ and $ITV_{2Phases}$, respectively, to the $ITV_{10Phases}$. The tumor motion index (TMI) was defined as the ratio of $ITV_{10Phases}$ to $CTV_{mean}$, which was the mean of 10 CTVs delineated on 10 respiratory phases. Results: The ITVs were significantly different in the order of $ITV_{10Phases}$, $ITV_{4Phases}$, and $ITV_{2Phases}$ (all p < 0.05). The MI of $ITV_{4Phases}$ was significantly higher than that of $ITV_{2Phases}$ (p < 0.001). The MI of $ITV_{4Phases}$ was inversely related to TMI (r = -0.569, p = 0.034). In a subgroup with low TMI (n = 7), $ITV_{4Phases}$ was not statistically different from $ITV_{10Phases}$ (p = 0.192) and its MI was significantly higher than that of $ITV_{2Phases}$ (p = 0.016). Conclusion: The $ITV_{4Phases}$ may be an efficient approach alternative to optimal $ITV_{10Phases}$ in SBRT for early-stage NSCLC with less tumor motion.

Study of the Optimize Radiotherapy Treatment Planning (RTP) Techniques in Patients with Early Breast Cancer; Inter-comparison of 2D and 3D (3DCRT, IMRT) Delivery Techniques (유방암 방사선치료 시 최적의 방사선치료계획기법에 대한 고찰)

  • Kim, Young-Bum;Lee, Sang-Rok;Chung, Se-Young;Kwon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.35-41
    • /
    • 2006
  • Purpose: A various find of radiotherapy treatment plans have been made to determine appropriate doses for breasts, chest walls and loco-regional lymphatics in the radiotherapy of breast cancers. The aim of this study was to evaluate the optimum radiotherapy plan technique method by analyzing dose distributions qualitatively and quantitatively. Materials and Methods: To evaluate the optimum breast cancer radiotherapy plan technique, the traditional method(two dimensional method) and computed tomography image are adopted to get breast volume, and they are compared with the three-dimensional conformal radiography (3DCRT) and the intensity modulated radiotherapy (IMRT). For this, the regions of interest (ROI) such as breasts, chest walls, loco-regional lymphatics and lungs were marked on the humanoid phantom, and the computed tomography(Volume, Siemens, USA) was conducted. Using the computed tomography image obtained, radiotherapy treatment plans (XiO 5.2.1, FOCUS, USA) were made and compared with the traditional methods by applying 3DCRT and IMRT. The comparison and analysis were made by analyzing and conducting radiation dose distribution and dose-volume histogram (DVH) based upon radiotherapy techniques (2D, 3DCRT, IMRT) and point doses for the regions of interest. Again, treatment efficiency was evaluated based upon time-labor. Results: It was found that the case of using 3DCRT plan techniques by getting breast volume is more useful than the traditional methods in terms of tumor delineation, beam direction and confirmation of field boundary. Conclusion: It was possible to present the optimum radiotherapy plan techniques through qualitative and quantitative analyses based upon radiotherapy plan techniques in case of breast cancer radiotherapy. However, further studies are required for the problems with patient setup reproducibility arising from the difficulties of planning target volume (PVT) and breast immobilization in case of three-dimensional radiotherapy planning.

  • PDF

Moderate hypofractionated image-guided thoracic radiotherapy for locally advanced node-positive non-small cell lung cancer patients with very limited lung function: a case report

  • Manapov, Farkhad;Roengvoraphoj, Olarn;Li, Minglun;Eze, Chukwuka
    • Radiation Oncology Journal
    • /
    • v.35 no.2
    • /
    • pp.180-184
    • /
    • 2017
  • Patients with locally advanced lung cancer and very limited pulmonary function (forced expiratory volume in 1 second $[FEV1]{\leq}1L$) have dismal prognosis and undergo palliative treatment or best supportive care. We describe two cases of locally advanced node-positive non-small cell lung cancer (NSCLC) patients with very limited lung function treated with induction chemotherapy and moderate hypofractionated image-guided radiotherapy (Hypo-IGRT). Hypo-IGRT was delivered to a total dose of 45 Gy to the primary tumor and involved lymph nodes. Planning was based on positron emission tomography-computed tomography (PET/CT) and four-dimensional computed tomography (4D-CT). Internal target volume (ITV) was defined as the overlap of gross tumor volume delineated on 10 phases of 4D-CT. ITV to planning target volume margin was 5 mm in all directions. Both patients showed good clinical and radiological response. No relevant toxicity was documented. Hypo-IGRT is feasible treatment option in locally advanced node-positive NSCLC patients with very limited lung function ($FEV1{\leq}1L$).