• Title/Summary/Keyword: tumor detection

Search Result 545, Processing Time 0.03 seconds

Detection of Multidrug Resistance Using Molecular Nuclear Technique (분자핵의학 기법을 이용한 다약제내성 진단)

  • Lee, Jae-Tae;Ahn, Byeong-Cheol
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.2
    • /
    • pp.180-189
    • /
    • 2004
  • Although the outcome of cancer patients after cytotoxic chemotherapy is related diverse mechanisms, multidrug resistance (MDR) for chemotherapeutic drugs due to cellular P-glycoprotein (Pgp) or multidrug-resistance associated protein (MRP) is most important factor in the chemotherapy failure to cancer. A large number of pharmacologic compounds, including verapamil, quinidine, tamoxifen, cyclosporin A and quinolone derivatives have been reported to overcome MDR. Single photon emission computed tomography (SPECT) and positron emission tomography (PET) are available for the detection of Pgp and MRP-mediated transporter. $^{99m}Tc$-MIBI and other $^{99m}Tc$-radiopharmaceuticals are substrates for Pgp and MRP, and have been used in clinical studies for tumor imaging, and to visualize blockade of PgP-mediated transport after modulation of Pgp pump. Colchicine, verapamil and daunorubicin labeled with $^{11}C$ have been evaluated for the quantification of Pgp-mediated transport with PET in vivo and reported to be feasible substrates with which to image Pgp function in tumors. Leukotrienes are specific substrates for MRP and $N-[^{11}C]acetyl-leukotriene$ E4 provides an opportunity to study MRP function non-invasively in vivo. SPECT and PET pharmaceuticals have successfully used to evaluate pharmacologic effects of MDR modulators. Imaging of MDR and reversal of MDR with bioluminescence in a living animal is also evaluated for future clinical trial. We have described recent advances in molecular imaging of MDR and reviewed recent publications regarding feasibility of SPECT and PET imaging to study the functionality of MDR transporters in vivo.

Accuracy of F-18 FDG PET/CT in Preoperative Assessment of Cervical Lymph Nodes in Head and Neck Squamous Cell Cancer: Comparison with CT/MRI (두경부 편평상피암 환자에서 수술 전 경부림프절 전이 평가에 대한 F-18 FDG PET/CT의 정확도: CT/MRI와의 비교)

  • Choi, Seung-Jin;Byun, Sung-Su;Park, Sun-Won;Kim, Young-Mo;Hyun, In-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.6
    • /
    • pp.309-315
    • /
    • 2006
  • Purpose: Accurate evaluation of cervical lymph node (LN) metastasis of head and neck squamous cell canter (SCC) is important to treatment planning. We evaluated the diagnostic accuracy of F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) for the detection of cervical LN metastasis of head and neck SCC and performed a retrospective comparison with CT/MRI findings. Materials & Methods: Seventeen patients with pathologically proven head and neck SCC underwent F-18 FDG PET/CT and CT/MRI within 4 week before surgery. We recorded lymph node metastases according to the neck level system of imaging-based nodal classification. F-18 FDG PET/CT images were analyzed visually for assessment of regional tracer uptake in LN. We analyzed the differences in sensitivity and specificity between F-18 FDG PET/CT and CT/MRI using the Chi-square test. Results: Among the 17 patients, a total of 123 LN levels were dissected, 29 of which showed metastatic involvement. The sensitivity and specificity of F-18 FDG PET/CT for detecting cervical LN metastasis on a level-by-level basis were 69% (20/29) and 99% (93/94). The sensitivity and specificity of CT/MRI were 62% (18/29) and 96% (90/94). There was no significant difference in diagnostic accuracy between F-18 FDG PET/CT and CT/MRI. Interestingly, F-18 FDG PET/CT detected double primary tumor (hepatocellular carcinoma) and rib metastasis, respectively. Conclusion: There was not statistically significant difference of diagnostic accuracy between F-18 FDG PET/CT and CT/MRI for the detection of cervical LN metastasis of head and neck SCC. The low sensitivity of F-18 FDG PET/CT was due to limited resolution for small metastatic deposits.

Progesterone assays as an aid for improving reproductive efficiency in dairy cattle V. Plasma progesterone determination as applied to the differential diagnosis of reproductive disorders and judgement of treatment responses to PGF2α or GnRH treatment (Progesterone 농도측정(濃度測定)에 의한 유우(乳牛)의 번식효율증진(繁殖效率增進)에 관한 연구(硏究) V. 혈장(血漿) progesterone 농도측정(濃度測定)에 의한 무발정(無發情)의 감별진단(鑑別診斷) 및 PGF2α 또는 GnRH 치료효과(治療效果)의 판정(判定))

  • Kang, Byong-kyu;Choi, Han-sun;Son, Chang-ho;Oh, Ki-seok;Kang, Hyun-ku;Kim, Sam-ju;Kim, Hyek-jin;Kim, Nam-ki
    • Korean Journal of Veterinary Research
    • /
    • v.35 no.3
    • /
    • pp.603-613
    • /
    • 1995
  • Plasma progesterone($P_4$) assay has been introduced to apply to the differential diagnosis of reproductive disorders and the monitoring of responses of ovarian dysfunction to $PGF_2{\alpha}$ or GnRH treatment in the 204 postpartum and postinsemination subestrus dairy cows. 1. The incidence rate of reproductive disorders in 204 subestrus cows, diagnosed by palpation per rectum and plasma $P_4$ determination using 'Two sample test'(Day 0+Day 10) were as follows; silent heat or error of estrus detection 110(53.9%), persistent corpus luteum 26(12.7%), follicular cyst 16(7.8%), inactive ovary 12(5.9%), luteal cyst 11(5.4%), granulosa cell tumor of ovary 1(0.5%), fetal mummification 1(0.5%), endometritis 15(7.4%) and pyometra 12(5.9%), respectively. 2. After the $PGF_2{\alpha}$ treatment to the 76 cows with silent heat or error of estrus detection, persistent corpus luteum, or luteal cyst, plasma $P_4$ concentrations at day 3 post treatment using 'Two sample test'(Day 0+Day 3) remained low(<1.0ng/ml) in all 76 cows. Therefore all 76 cows responded positively to $PGF_2{\alpha}$ treatment. Seventeen cows with follicular cyst or inactive ovary were treated with GnRH. All 7 cows with follicular cyst and 4 cows with inactive ovary remained high($${\geq_-}1.0ng/ml$$) a plasma $P_4$ concentrations at day 12 post treatment using 'Two sample test'(Day 0+Day 12), but 6 cows with inactive ovary remained low(<1.0ng/ml) a plasma $P_4$ concentrations. Therefore all 7 cows with follicular cyst and 4 cows with inactive ovary responded positively, but 6 cows with inactive ovary responded negatively to GnRH treatment. 3. The mean days from treatment to first service, number of cows conceived on first service(%), mean number of services per conception, mean days from initial treatment to conception, and mean number of cows conceived by 100 days post treatment(%) were 5.0 and 26.2 days, 45(59.2%) and 6(35.3%) cows, 1.5 and 1.7 services, 13.6 and 22.6 days, and 62(81.6%) and 9(52.9%) cows in group of $PGF_2{\alpha}$ and GnRH treatment, respectively. These results indicated that plasma $P_4$ assay was practical as an aid to diagnosing reproductive disorders and to monitoring responses of ovarian dysfunction to $PGF_2{\alpha}$ and GnRH treatment in subestrus cows.

  • PDF

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.

Immunohistochemical Detection of Lymph Nodes Micrometastases in Patients of Pathologic Stage I Non-small-cell Lung Cancer (병리적 병기 1기의 비소세포폐암 환자에서 면역조직화학염색에 의한 림프절 미세전이 관찰)

  • Ryu, Jeong-Seon;Han, Hye-Seung;Kim, Min-Ji;Kwak, Seung-Min;Cho, Jae-Hwa;Yoon, Yong-Han;Lee, Hong-Lyeol;Chu, Young-Chae;Kim, Kwang-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.4
    • /
    • pp.345-350
    • /
    • 2004
  • Background : To evaluate the frequency and clinical significance of lymph node micrometastasis in patients of non-small-cell lung cancer pathologically staged to be T1-2,N0. Method : From consecutive 29 patients of non-small-cell lung cancer who received curative operation and routine systemic nodal dissection, we immunohistochemically examined 806 lymph nodes from mediastinal, hilar and peribronchial lesion. All slides were stained with hematoxylin and eosin staining for one section and with cytokeratin AE1/AE3 antibody for another consecutive section of same lymph node to find out micrometastasis. Results : In 806 lymph nodes examined, no tumor cell was seen on hematoxylin and eosin staining and micrometastic foci were shown to be on 0.37%(3) of 806 lymph nodes, in which were upper paratracheal, interlobar and peribronchial lymph node. These three positive stains constitute 10.3%(3) of the 29 patients with non-small-cell lung cancer. Nine patients died from disease progression(4), postoperative complication(3) and concomitant diseases(2). The four patients with disease progression did not show evidence of micrometastasis on their lymph node examination. Conclusion : The frequency of lymph node micrometastasis was in 0.37% of 806 lymph nodes examined. The study results might suggested that routine analysis of micrometastasis on the lymph node didn't give any clinical implication on patients with non-small-cell lung cancer.

Monte Carlo Simulations of Detection Efficiency and Position Resolution of NaI(TI)-PMT Detector used in Small Gamma Camera (소형 감마카메라 제작에 사용되는 NaI(TI)- 광전자증배관 검출기의 민감도와 위치 분해능 특성 연구를 위한 몬테카를로 시뮬레이션)

  • Kim, Jong-Ho;Choi, Yong;Kim, Jun-Young;Im, Ki-Chun;Kim, Sang-Eun;Choi, Yeon-Sung;Joo, Kwan-Sik;Kim, Young-Jin;Kim, Byung-Tae
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.67-76
    • /
    • 1997
  • We studied optical behavior of scintillation light generated in NaI(TI) crystal using Monte Carlo simulation method. The simulation was performed for the model of NaI(TI) scintillator (size: 60 mm ${\times}$ 60 mm ${\times}$ 6 mm) using an optical tracking code. The sensitivity as a function of surface treatment (Ground, Polished, Metal-0.95RC, Polished-0.98RC, Painted- 0.98RC) of the incident surface of the scintillator was compared. The effects of NaI(TI) scintillator thickness and the refractive index of light guide optically coupling between the NaI(TI) scintillator and photomultiplier tube (PMT) were simulated. We also evaluated intrinsic position resolution of the system by calculating the spread of scintillation light generated. The sensitivities of the system having the surface treatment of Ground, Polished, Metal-0.95RC, Polished-0.98RC and Painted-0.98RC were 70.9%, 73.9%, 78.6%, 80.1% and 85.2%, respectively, and the surface treatment of Painted-0.98RC allowed the highest sensitivity. As increasing the thickness of scintillation crystal and light guide, the sensitivity of the system was decreased. As the refractive index of light guide increases, the sensitivity was increased. The intrinsic position resolution of the system was estimated to be 1.2 mm in horizontal and vertical directions. In this study, the performance of NaI(TI)-PMT detector system was evaluated using Monte Carlo simulation. Based on the results, we concluded that the NaI(TI)-PMT detector array is a favorable configuration for small gamma camera imaging breast tumor using Tc-99m labeled radiopharmaceuticals.

  • PDF

Hypothyroidism Following Surgery and Radiation Therapy for Head and Neck Cancer (두경부암 환자에서 수술 및 방사선치료 후 갑상선 기능 저하)

  • Park, In-Kyu;Kim, Jae-Cheol
    • Radiation Oncology Journal
    • /
    • v.15 no.3
    • /
    • pp.225-231
    • /
    • 1997
  • Purpose : Radiation therapy in combination with surgery has an important role in the therapy of the head and neck cancer We conducted a prospective study for patients with head and neck cancer treated with surgery and radiation to evaluate the effect of therapies on the thyroid gland, and to identify the factors that might influence the development of hypothyroidism. Materials and Methods : From September 1986 through December 1994, 71 patients with head and cancer treated with surgery and radiation were included in this prospective study. Patients' age ranged from 32 to 73 years with a median age of 58 years. There were 12 women and 59 men. The primary tumor sites were larynx in 34 patients, hypopharynx in 13 patients, oral cavity in 12 patients, unknown primary of the neck in 6 patients, salivary gland in 3 patients, maxillary sinus in 2 patients, and oropharynx in 1 patient. Total laryngectomy with neck dissection was carried out in 45 patients and neck dissection alone in 26 patients. All patients were serially monitored for thyroid function (T3, T4, free T4, TSH, antithyroglobulin antibody and antimicrosomal antibody) before and after radiation therapy. Radiation dose to the thyroid gland ranged from 40.6Gy to 60Gy with a median dose of 50Gy The follow-up duration was 3 to 80 months. Results :The overall incidence of hypothyroidism was 56.3\%$);7 out of 71 patients $(9.9\%)$ developed clinical hypothyroidism and 33 patients $(46.4\%)$ developed subclinical hypothyroidism. No thyroid nodules, thyroid cancers, or hyperthyroidism was detected. Hypothyroidism developed earlier in patients who underwent total laryngectomy with neck dissection than in patients with neck dissection alone (P<0.05). The risk factor that significantly influenced the incidence of hypothyroidism was a combination of surgery (total laryngectomy with neck dissection) and radiation therapy (P=0.0000), Four of 26 patients $(15.4\%)$ with neck dissection alone developed hypothyroidism while 36 of 45 patients $(80\%)$ with laryngectomy and neck dissection developed hypothyroidism. Conclusion : The hypothyroidism following surgery and radiation therapy was a relatively common complication. The factor that significantly influenced theincidence of hypothyroidism was combination of surgery and radiation therapy. Evaluation of thyroid function before and after radiation therapy with periodic thyroid function tests is recommended for an early detection of hypothyroidism and thyroid hormone replacement therapy is recommended whenever hypothyroidism develops.

  • PDF

Surgical Treatment of Primary Lung Cancer (원발성 폐암의 외과적 치료)

  • 김성완;구본원;이응배;전상훈;장봉현;이종태;김규태;강덕식
    • Journal of Chest Surgery
    • /
    • v.31 no.2
    • /
    • pp.134-141
    • /
    • 1998
  • Primary lung cancer has recently increased progressively in its incidence in Korea. It is clearly evident that surgical resection offers the best offortunity for cure of non-small cell carcinoma. This study was designed to analyse the clinical data of 100 primary non-small cell carcinoma patients who underwent lung resection surgery from January 1992 to July 1995 at the department of Thoracic and Cardiovascular Sugery, Kyungpook National University Hospital. There were 86 males and 14 females(6:1). In the age distribution, the peak incidence was recorded in the seventh decade(43%). The methods of tissue diagnosis were bronchoscopic biopsy in 53 patients(50.5%), percutaneous needle aspiration in 17 patients(16.2%), transbronchial lung biopsy in 11 patients(10.5%), mediastinoscopic biopsy in 2 patients (1.9%), sputum cytology in 2 patients(1.9%), and thoracotomy in 20 patients(19.0%). Fifty-five lobectomies, 22 pneumonectomies, 15 bilobectomies, 2 segmentectomies, 4 sleeve lobectomies, a sleeve pneumonectomy, and a wedge pneumonectomy were performed. Operative mortality occured in 4 cases(sepsis in 2 cases, respiratory failure in 1 case, and acute myocardiac infarction in 1 case). The histologic types of tumor were 67 squamous cell carcinomas, 26 adenocarcinomas, 6 large cell carcinomas, and an adenosquamous cell carcinoma. Eighteen patients with N2 mediastinal lymph node metastases had 8 squamous cell carcinomas(11.9%), 9 adenocarcinomas(34.6%), and a large cell carcinoma(16.7%). The primary tumors in these patients were in the right upper lobe in 4 patients, the right middle and lower lobe in 9 patients, the left upper lobe in 3 patients, and the left lower lobe in 2 patients. With regard to pathologic stages, 45 patients had stage I disease; 13 patients, stage II; 36 patients, stage IIIa; 5 patients, stage IIIb; and 1 patient, stage IV. The overall actuarial survival rate was 77.5% at 12 months, 56.1% at 24 months and 43.7% at 43 months. The actuarial survival rates at 43 months were 81.3% in Stage I, 20.8% in Stage II, 27.9% in Stage IIIa, 25.0% in Stage IIIb and 33.3% in Stage IV. These facts suggest that early detection and surgical resection are recommended for favorable postoperative survival in non-small cell lung cancer.

  • PDF

Clinical features of congenital muscular torticollis (선천성 근성 사경의 임상적 특징)

  • Jun, Ji Eun;Ryu, Hye Kyeong;Shim, Jae Won;Shim, Jung Yeon;Jung, Hye Lim;Park, Moon Soo;Kim, Deok-Soo
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.3
    • /
    • pp.241-247
    • /
    • 2007
  • Purpose : Congenital muscular torticollis (CMT) is a common and benign congenital disorder of the musculoskeletal system in neonates and infants. The pathophysiology is that the sternocleidomastoid muscle (SCM) is shortened on the involved side by fibrosis, leading to ipsilateral tilt and contralateral rotation of the face and chin. In this study, we investigated the clinical features of CMT, the role of ultrasonography (USG) in prediction of prognoses and the clinical significance of early detection and treatment. Methods : Forty seven patients (M:F=31:16) were diagnosed as a CMT between March 2003 and May 2006. We reviewed age at diagnosis, physical findings, USG findings, treatment and therapeutic outcome from their medical records. Results : The median age at diagnosis was 90 days (18 days-9 years, 7 months) and the right side of neck was affected in more patients (right : left=26:21). Of 24 patients with a palpable neck mass, 21 had USG; 19 cases showed sternocleidomastoid tumor (SMT). In cases with no neck mass, USG was performed in 11 patients; seven had postural torticollis (POST), three had SMT and one had muscular torticollis (MT). Among 40 patients with follow-up, 36 had total resolution. There was negative correlation between the age at diagnosis and the recovery time, whereas the final outcome was not correlated with USG findings. However, the patients without positive findings in USG had earlier resolution (1 month vs 2.6 months, P=0.0008). The patients with SMT had earlier diagnosis and excellent outcomes. The patients with MT were delayed to diagnosis and had the longest time to resolve. Lastly, the patients with POST had delayed diagnoses, but they had excellent outcomes. Conclusion : Since the patients with delayed diagnoses, in despite of benign courses, may take a long time to resolve and rarely need surgical treatment, it is important to diagnose and treat early. This study showed that USG findings of the SCM may be used as predictive factors.

The evaluation of dose of TSEI with TLD and diode dector of the uterine cervix cancer (열형광선량계와 반도체검출기를 이용한 전신피부전자선조사의 선량평가)

  • Je Young Wan;Na Keyung Su;Yoon IL Kyu;Park Heung Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.57-71
    • /
    • 2005
  • Purpose : To evaluate radiation dose and accuracy with TLD and diode detector when treat total skin with electron beam. Materials and Methods : Using Stanford Technique, we treated patient with Mycosis Fungoides. 6 MeV electron beam of LINAC was used and the SSD was 300 cm. Also, acrylic speller(0.8 cm) was used. The patient position was 6 types and the gantry angle was 64, 90 and $116^{\circ}$. The patient's skin dose and the output were detected 5 to 6 times with TLD and diode. Result : The deviations of dose detected with TLD from tumor dose were CA $+\;6\%$, thigh $+\;8\%$, umbilicus $+\;4\%$, calf $-\;8\%$, vertex $-\;74.4\%$, deep axillae $-\;10.2\%$, anus and testis $-\;87\%$, sole $-\;86\%$ and nails shielded with 4mm lead $+4\%$. The deviations of dose detected with diode were $-4.5\%{\sim}+5\%$ at the patient center and $-1.1\%{\sim}+1\%$ at the speller. Conclusion : The deviation of total skin dose was $+\;8\%{\sim}-\;8\%$ and that deviation was within the acceptable range(${\pm}\;10\%$). The boost dose was irradiated for the low dose areas(vertex, anus, sole). The electron beam output detected at the sootier was stable. It is thought that the deviation of dose at patient center detected with diode was induced by detection point and patient position.

  • PDF